AXIMA Resonance MALDI Mass Spectrometer from Shimadzu

AXIMA Resonance MALDI Mass Spectrometer from Shimadzu

AXIMA Resonance MALDI Mass Spectrometer from Shimadzu

Description

Combining the simplicity of MALDI, the power of MSn, and the accuracy and resolution of TOF, the AXIMA Resonance provides researchers a unique solution to the next generation of structural and sequencing challenges. Designed without compromise, the AXIMA Resonance features high mass resolution and mass accuracy across MS and MSn analyses, excellent precursor ion selection, variable energy CID control on the fly, and outstanding sensitivity to ensure confident, high-quality results across a range of applications.

Features

Advanced MSn Performance
The unique combination of MALDI and QIT allows generation of ions using a number of different matrices; switching between positive and negative ionization modes in seconds; simple high resolution precursor ion selection for MSn experiments, and controllable MSn fragmentation.

Incorporating a TOF analyzer promotes high resolution and high mass accuracy for all ions generated regardless of their origin.

Excellent Precursor Ion Selection
Allows ions from complex mixtures or closely associated neighboring isotopic envelopes to be easily isolated and subsequently fragmented; trapping resolution greater than 1000 FWHM permits the analysis of samples with similar nominal mass.

High Sensitivity/Resolution
Near axis laser irradiation provides enhanced ion transmission and sensitivity in all modes of operation, while an uncompromised design ensures highly efficient trapping functionality.

Low Sample Consumption
Allows many more MSMS experiments to be performed on the same sample spot.

Manual or Fully Automated Operation
Allows the seamless analysis of as few or many samples as required

Unparalleled Flexibility
Not just another proteomics workhorse, polymers, oligonucleotides, SNPs, metabolites, carbohydrates and small molecules, among others, may all be analyzed and processed. It is suitable with most common MALDI matrices, and a variety of sample target formats, including standard microtiter plate format and microscope slide design targets, can be used.

Seamless Integration with Other Instruments
Like all AXIMA MALDI-TOF systems, the AXIMA Resonance can be fully integrated with robotic sample preparation devices, including the AccuSpot MALDI plate spotter and CHIP chemical printer, to create application-specific platforms. Integration with the CHIP creates a powerful platform for tissue imaging, while using an AXIMA instrument with a Prominence GPC system and AccuSpot results in a fully automated platform for polymer analysis that delivers quick, detailed analysis of ultra-trace substances.

The AXIMA Resonance can also be combined with various fractionation/enrichment chemistries and Nonlinear Dynamic’s Progenesis biomarker software for a complete, integrated biomarker discovery solution.

  • Detailed Specifications
  • ItemAXIMA Resonance MALDI Mass Spectrometer
  • CompanyShimadzu
  • PriceGet Quote
  • Catalog NumberAXIMA Resonance
  • QuantityEA
  • Resolutionup to 1000 FWHM
  • Ionization Method(s)MALDI
  • Mass AnalyzerQIT TOF
  • Scanning SpeedInquire
  • Mass Range100 to 12000 Da