CyAn ADP High-Performance Flow Cytometer from Beckman Coulter Inc

Description

CyAn ADP uses multiple laser excitation sources to analyze biological cells, beads or other microscopic particles.

With two models to accommodate a diverse range of applications, with up to 11 standard parameters and 9 colors, the CyAn ADP analyzer is the next step in Advanced Digital Processing with true high speed analysis capability.

CyAn ADP integrated to the HyperCyt plate loader enables high throughput screening of 384-well plates in less than 10 minutes. With front end automation of the HyperCyt and the sensitive optics and analysis speed of the CyAn ADP, compound screening and HTS assays are performed quickly and accurately.

CyAn ADP uses multiple laser excitation sources to analyze biological cells, beads or other microscopic particles. The CyAn ADP has state-of-the-art optics, utilizes high performance digitization with pulse processing speed up to 70,000 events per second complementing a high acquisition and analysis capability of up to 100,000,000 event data files.

Features
  • Enhanced detection for flow cytometry
  • State-of-the-art optics and electronics
  • Automated compensation
  • Easy to walk-up operation
We offer two models to accommodate a diverse range of applications, with up to 11 standard parameters and 9 colors.

CyAn ADP 7 Color has 9 parameters (FSC, SCC, FL1-FL7) and is equipped with 488 nm and 642 nm solid-state lasers. Some key research applications include CD34 enumeration, signal transduction, antigen-specific T-cell detection and multicolor immunophenotyping.

CyAn ADP 9 Color adds the 405 nm solid state laser and two fluorescent channels. Up to 9x9 parameter compensation can be performed manually, using bi-exponential transformation (VisiComp) or automatically. Additional research applications include stemcell/SPanalysis, DAPI Cell Cycle analysis and CFP-YFP FRET analysis.
  • Detailed Specifications
  • ItemCyAn ADP High-Performance Flow Cytometer
  • CompanyBeckman Coulter Inc
  • PriceInquire
  • Catalog NumberCY20030 / CY20031 / CY20033 / CY20130 / CY20131 / CY20133
  • QuantityEA
  • Sample VolumeInquire
  • Throughputup to 150 uL/min (384-well plates in less than 10 min with HyperCyt plate loader)
  • Sample FormatInquire
  • Cells per AssayInquire
  • Excitation WavelengthInquire
  • Emission Wavelength405, 488 or 638 nm
  • ScatterInquire
Beckman Coulter Inc
Beckman Coulter Inc
11800 SW 47th Ave
Miami, FL 33196
United States
Phone: (800) 526-3821