Gravimetric sorption is a popular analytical method utilized for the determination of the rate of interaction between a gas and an either solid or liquid material. The gravimetric sorption technique works with a sample’s weight being continuously measured on a microbalance as gas pressure is modulated under a constant temperature. Sorption update is established based on the measured changes of weight.
Get Quote for All
Select up to 5 products from below to compare or request more information.
Hiden Isochema
- 77 K to 1000 °C
- 10 bar (standard), or 20 bar (optional)
- Energy storage, Gas solubility, Gas adsorption capacity determination, Thermodynamic and kinetic studies, Specific surface area (BET) determination
Hiden Isochema
- 77 K to 1000 °C
- 10 bar (standard), or 20 bar (optional)
- Moisture and organic vapor sorption, Diffusion coefficient determination, Thermodynamic and kinetic studies, Gas sorption capacity determination
Hiden Isochema
- 77 K to 1000 °C
- 10 bar (standard), or 20 bar (optional)
- Energy storage, Temperature Programmed Desorption/Oxidation/Reduction (TPD/TPO/TPR), Gas adsorption capacity determination, Thermodynamic and kinetic studies, Evolved Gas Analysis (EGA) and Thermogravimetric Analysis (TGA)
Hiden Isochema
- 77 K to 1000 °C
- 10 bar (standard), or 20 bar (optional)
- Gas adsorption capacity determination, Moisture and organic vapor sorption, Catalyst characterization, Moisture and organic vapor sorption with diffusion coefficient determination, Thermogravimetric Analysis (TGA) and Evolved Gas Analysis (EGA), Temperature Programmed Desorption/Oxidation/Reduction (TPD, TPO, TPR)
Hiden Isochema
- 77 K to 773 K
- up to 200 bar
- Gas storage, Gas separation and purification, Thermodynamic and kinetic studies, Nanoporous materials (carbons, zeolites, MOFs and polymers)
Hiden Isochema
- 77 K to 500 °C
- up to 200 bar
- Hydrogen storage capacity determination, Pressure-Composition-Temperature (PCT) measurements, Thermodynamic and kinetic studies, Metal hydrides and nanoporous materials (carbons, zeolites, MOFs and polymers)
Hiden Isochema
- 77 K to 773 K
- up to 200 bar
- Gas adsorption isotherm determination, Specific surface area (BET) determination, Energy gas (H2, CH4) storage and separation, Thermodynamics of high pressure gas adsorption, Nanoporous materials (carbons, zeolites, MOFs, polymers and shales)
Hiden Isochema
- 77 K to 500 °C
- Inquire
- Carbon capture and storage, Hydrogen and natural gas storage, Gas solubility in ionic liquids, Nanoporous material characterization, Gas sorption on geological materials
Hiden Isochema
- 77 K to 500 °C
- Inquire
- VOC filtration, Thermochemical energy storage, Toxic gas storage and separation
Hiden Isochema
- 77 K to 500 °C
- Inquire
- High pressure catalysis, Flue gas desulfurization, Gas-solid reaction kinetics
Hiden Isochema
- 77 K to 500 °C
- Inquire
- Energy gas storage, High pressure TGA, Polymer membrane characterization
Select up to 5 products from above to compare or request more information.
Tags:
Please Login or Register to Create Tags
- Ultimate Isothermal Analysis
Hiden Isochema
We have been using the IGA-001 Gas Sorption analyzer for analyzing single component gas-liquid interactions and are quite impressed by its performance so far. It is an efficient gravimetric analysis ... Read Review