Biological safety cabinets (biosafety cabinets) come in several classes (I, II, and III) that offer varying levels of protection from hazardous or contagious materials. For all classes of biological safety cabinet, the air is HEPA (high efficiency particulate air)-filtered before being released as exhaust. A Class I biosafety cabinet is designed to protect the user and the environment, not the sample as negative pressure is used to pull outside air in across the workspace.
Class II biological safety cabinets are divided into four subtypes (A1, A2, B1, and B2) and have the additional feature of protecting the sample as the air supply is HEPA-filtered before passing over the workspace. The Class II subtypes differ in the amount of recirculated air within the cabinet.
Class III biosafety cabinets (also known as gloveboxes) provide maximum protection for work in biosafety level 4 containment labs. A class III biosafety cabinet is a hermetically-sealed glovebox with access through a dunk tank or double-door box that allows for decontamination.
| | |
Company | NuAire | NuAire |
Item | LabGard ES (Energy Saver) NU-540 Class II, Type A2 Bioafety Cabinet | LabGard NU-813 Class I Containment Ventilated Enclosure (CVE) |
Citations | | |
Catalog Number | NU-540 | NU-813 |
Price | | |
Class/Type | Class II, Type A2 | Class I |
Air Inflow Rate | 105 fpm (0.53 m/s) | 80 fpm |
Size(s) | 3, 4, 5, 6-foot (0.9, 1.2, 1.5, 1.8-meter) | 3, 4, 6-foot (0.9, 1.2, 1.8-meter) |
Recirculated/Exhausted Air | 70% / 30% | 0% / 100% |
Exterior Dimensions | varies with model | varies with model |
Interior Dimensions | varies with model | varies with model |
Description | The LabGard® ES NU-540 Class II, Type A2 Laminar Flow Biological Safety Cabinet (LFBSC) is an effective primary engineering control in obtaining the optimum product quality while reducing the potential for exposure of both product and personnel to airborne biological or particulate chemical agents The LabGard® ES NU-540 Class II, Type A2 Laminar Flow Biological Safety Cabinet (LFBSC) is an effective primary engineering control in obtaining the optimum product quality while reducing the potential for exposure of both product and personnel to airborne biological or particulate chemical agents in low to moderate risk-hazard research and drug preparation.The NU-540 offers economical operation through the use of an ultra high efficiency motor to maximize filter life and monolithic silicone-free construction for long product life.... Read More | The LabGard Containment Cabinet NU-813 is offered as a Class I Containment Cabinet equipped with a HEPA filter. In the Class I configuration, the NU-813 provides personnel protection for handling low risk aerosols and particulate matter. Room air enters the Cabinet, flowing past the operator into The LabGard Containment Cabinet NU-813 is offered as a Class I Containment Cabinet equipped with a HEPA filter. In the Class I configuration, the NU-813 provides personnel protection for handling low risk aerosols and particulate matter. Room air enters the Cabinet, flowing past the operator into the work access opening providing an air barrier which minimizes contaminants generated within the cabinet work zone from migrating into the room. The air flows through the cabinet carrying contaminants with it, exiting through a HEPA filter as a Class I Cabinet.... Read More |