Differential scanning calorimetry analysis provides insight into critical physical properties of materials by testing their response to heat. The heating of both a sample and reference material provides a validated relative temperature response and heat capacity. These furnace-based systems are perfect for studying unique phase-change properties, such as with liquid crystals, determining quantitative enthalpy of materials, or testing the elasticity of products exposed to extreme temperatures and/or pressures. Differential scanning calorimeters offer temperature ranges as low as -180C and as high as 2400C, with the highest available heating rate at 300 K/min for DSC analysis. The principle models utilize heat flux systems, corrosion-free silver furnaces, or cylindrical high-conductivity silver block units, among others. The customer should keep an eye out for a differential scanning calorimeter that suppresses or prevents overlapping vaporization and/or simulates realistic temperature and pressure conditions.

Showing 16 of 16 products
  • <<
  • >>
Get Quote for All
Select up to 5 products from below to compare or request more information.
DSC PT1000 Differential Scanning Calorimeter
  • Temperature Range: -150 to 725°C (DSC PT1000) or -180 to 750°C (DSC PT1000 HiRes)
  • Heating Rate: 0.01 to 100 K/min (DSC PT1000) or 0.001 to 300 K/min (DSC PT1000 HiRes)
Compare or Get Quote for selected.
DSC PT1600 Differential Scanning Calorimeter
  • Temperature Range: -150°C to 1750°C
  • Heating Rate: 0.001 to 50 K/min
Compare or Get Quote for selected.
  • Temperature Range: -150C to 700C
  • Measuring Range: +/- 140 mW to +/- 350 mW (depending on temperature and sensor type)
  • Heating Rate: 0.02 to 300 K/min
Compare or Get Quote for selected.
HP DSC 1 High Pressure Differential Scanning Calorimeter
  • Temperature Range: 22C to 700C
  • Measuring Range: +/- 350 mW or +/- 160 mW (at 100C)
  • Heating Rate: 0.1 to 50 K/min
Compare or Get Quote for selected.
DSC 204 F1 Phoenix - Differential Scanning Calorimeter
  • Temperature Range: -180C to 700C
  • Measuring Range: Inquire
  • Heating Rate: 0.001 to 200 K/min
Compare or Get Quote for selected.
DSC 204 HP Phoenix - High-Pressure DSC Instrument
  • Temperature Range: -150 to 600C
  • Measuring Range: Inquire
  • Heating Rate: 0.01 to 100 K/min
Compare or Get Quote for selected.
  • Temperature Range: -170°C to 600°C
  • Measuring Range: Inquire
  • Heating Rate: 0.001 K/min to 500 K/min
Compare or Get Quote for selected.
DSC 3500 Sirius Differential Scanning Calorimeter
  • Temperature Range: -170C to 600C
  • Measuring Range: 0 to +/- 650 mW
  • Heating Rate: 0.001 to 100 K/min
Compare or Get Quote for selected.
DSC 404 F1 Pegasus - High-Temperature DSC Instrument
  • Temperature Range: Wide Range within -150 to 2000C
  • Measuring Range: Cp measuring range: 0 to 5 J/(g*K)
  • Heating Rate: 0.001 to 50 K/min
Compare or Get Quote for selected.
DSC 404 F3 Pegasus - High-Temperature DSC / DTA Analyzer
  • Temperature Range: -150 to 2000C
  • Measuring Range: Cp measuring range: 0 to 5 J/(g*K)
  • Heating Rate: 0.001 to 50 K/min
Compare or Get Quote for selected.
  • Temperature Range: -140 to 600C
  • Measuring Range: ±150 mW
  • Heating Rate: 20 C/min