Particle analyzers are used to determine the size and distribution of particles making up a material. Particle size analyzers are used in numerous fields for research and development, manufacturing and for quality control and product testing. Different technologies enable analysis across a wide range of sizes, of particles in powder, liquid, aerosol or other forms, and of materials ranging in diversity from soil, paint and cosmetics to nasal spray and proteins.
Laser diffraction particle size analyzers calculate particle size from the angle of light scattered by a stream of particles passing through a laser beam. This technique allows for continuous measurement of bulk material across a wide size range (10 nm to 3 mm). The size limits and sensitivity of a laser diffraction particle analyzer depend on the number and placement of detectors in the instrument. Dynamic light scattering particle analyzers are mainly used for analyzing particles in solution (size range: 1 nm to 6 um). Dynamic light scattering determines size from the fluctuations in scattered laser light intensity created by the particles’ Brownian motion. Induced grating particle size analyzers identify the size of even smaller particles (0.5 nm to 200 nm) in solutions by electrically aligning the particles and then measuring their diffusion.
Find, compare, and request a quote for particle size analyzers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
Your search for AF4 returned 0 results.
Get Quote for All
Select up to 5 products from below to compare or request more information.
Other Particle Size Analyzer (Particle Analyzers / Particle Sizer) Products
Bettersize Instruments Ltd.
- 0.3nm - 15µm
- Avalanche photodiode (APD)
- Inquire
- Abrasives, Academia, Foods and Beverages, Household Chemicals, Life Sciences Nanomaterials, Pharmaceuticals, Paints, Inks & Coatings
Proteins & Polypeptides
Bettersize Instruments Ltd.
- 0.02 - 2600µm (Wet)
0.1 - 2600µm (Dry) - 92 detectors (forward, lateral and backward arrangements)
- Typical measurement time: Less than 10 seconds
- 3D Printing Materials, Abrasives, Batteries, Building Materials, Ceramics, Cosmetics, Food & Beverage, Mining & Materials, Paints, Inks & Coatings, Pharmaceuticals
Entegris
- Inquire
- Extinction, Scattering, Collimated, and/or Focused (sensor dependent)
- Inquire
- Materials Testing, Pharmaceutical Lab
Entegris
- Inquire
- 15 – 100 mW red laser diodes, 20 – 100 mW green laser diodes
- Inquire
- Materials Testing, Pharmaceutical Lab
HORIBA Scientific
- Inquire
- Approx. 10 minutes
- Inquire
Malvern Panalytical
- 0.01 to 3500 µm (Wet analysis), 0.1 to 3500 µm (Dry analysis)
- Log Spaced State-of-the-Art Detector array
- < 10 s
- Inquire
Malvern Panalytical
- (Lab and Pro) 0.1 - 1000 µm / (Ultra) 0.01 - 3500 µm
- Log-spaced array
- < 10 sec
- Inquire
Malvern Panalytical
- 10 to 1000 nm
- Inquire
- Inquire
- Extracellular Vesicles (EV), Virus and Vaccines, Drug Delivery & Gene Therapy, Biotherapeutics, Nanomaterials/colloids/toxicology, Ultrafine bubbles
Malvern Panalytical
- 0.3 nm to 10 µm (diameter)2
- Inquire
- Inquire
- Inquire
Bettersize Instruments Ltd.
- Less than 10 seconds
- 3D Printing Materials, Abrasives, Battery and Energy, Building Materials, Ceramics, Food and Beverages, Paints, Inks, and Coatings, Pharmaceuticals, Powder Metallurgy, Soils and Sediments
Bettersize Instruments Ltd.
- Inquire
- Less than 10 seconds
- Abrasives, Agrochemical, Batteries, Building Materials, Ceramics, Chemicals, Metals, Mining and Minerals, Paints and Pigments, Plastics
Bettersize Instruments Ltd.
- 30 to 10,000 µm
- Inquire
- Inquire
- Abrasives, Additive Manufacturing (3D Printing), Agriculture,Food and Beverages, Mining and Minerals,Paints, Inks & Coatings,Pharmaceuticals,Plastic and Resins
Bettersize Instruments Ltd.
- 1 to 10,000 µm
- Inquire
- Inquire
- Abrasives, Agriculture, Automotive, Ceramics, Metal Powders, Mining & Materials, Paints, Inks & Coatings, Surface Cleanliness
Bettersize Instruments Ltd.
- Inquire
- Inquire
- 3 to 5 min
- Abrasives, Agriculture, Biology and Microorganisms, Ceramics, Metal Powders, Mining & Materials, Paints, Inks & Coatings, Pharmaceuticals
Entegris
- Inquire
- Extinction, Scattering, Collimated, and/or Focused (sensor dependent)
- Inquire
- Materials Testing, Pharmaceutical Lab
Entegris
- Inquire
- Extinction, Scattering, Collimated, and/or Focused (sensor dependent)
- Inquire
- Materials Testing, Pharmaceutical Lab
Entegris
- Inquire
- Focused beam, scatter 0.15-10+ µm at high concentration
- Inquire
- Materials Testing, Pharmaceutical Lab
Entegris
- Inquire
- Extinction, Scattering, Collimated, and/or Focused (sensor dependent)
- Inquire
- Materials Testing, Pharmaceutical Lab
Entegris
- Inquire
- Extinction, Scattering, Collimated, and/or Focused (sensor dependent)
- Inquire
- Materials Testing, Pharmaceutical Lab
Entegris
- Inquire
- Inquire
- Inquire
- CMP slurries, other suspensions
Entegris
- 0.15 to 400 µm
- Extinction and Scattering
- < 10s
- Inquire
Entegris
- Inquire
- Inquire
- Inquire
- Submicron suspensions and emulsions
Entegris
- Inquire
- PMT standard, optional 7X gain APD
- Inquire
- Materials Testing, Pharmaceutical Lab
Entegris
- Inquire
- 15 – 100 mW red laser diodes, 20 – 100 mW green laser diodes
- Inquire
- Materials Testing, Pharmaceutical Lab
FRITSCH GmbH
- Inquire
- Specially designed semi-conductor detector
- 5 – 10 s (measurement value recording of an individual measurement), 1 min (entire measurement cycle)
- Inquire
FRITSCH GmbH
- Inquire
- Specially designed semi-conductor detector
- 5 – 10 s (measurement value recording of an individual measurement), 1 min (entire measurement cycle)
- Inquire
FRITSCH GmbH
- 20 µm to 20 mm
- Inquire
- < 5 min.
- Inquire
Genizer LLC
- Inquire
- Photomultiplier tube (PMT)
- Inquire
HORIBA Scientific
- Minimum volume of 12 µL*3 to 1000 µL (differs depending on cell material)
- Inquire
- Approx. 2 min. under ordinary conditions
(from the start of measurement to the display of results for particle size measurement)
- Zeta Potential of Proteins, Polyelectrolytes, and Clay for Wastewater Treatment, DLS vs. Diffraction of Flavor Emulsions, Wastewater Treatment Optimization with Zeta Potential, Sizing Silica Particles by DLS, Nanoparticle Analysis, Metal Nanoparticle Size and Surface Charge (Zeta Potential), Protein Aggregation and Size Analysis, Titanium Dioxide Particle Size, Viruses and Virus-Like Particles, Particle Analysis for Cosmetics
HORIBA Scientific
- Inquire
- Inquire
- Inquire
- Analysis of the Dispersed State of Graphene Oxide (Mixed and Isolated), Analysis of Particle Size Distribution of Rod-Shaped Gold Nanoparticle, Particle Size Analysis of a Mixed Sample of Five Sizes of Polystyrene Latex Standards, Carbon Nanotube with Porosity Correction, Analysis of Multimodal Particle Size Distribution of a Mixture of Four Different Sized Silica Standards, Particle Size Analysis of a Mixed Sample of Three Sizes with Equal Log Spacing, Acid Hydrolyzed Cellulose Nanocrystal, TEMPO-Oxidized Cellulose Nanocrystal, and Fumed Silica, Particle Sizing of Cellulose Nanofiber, Analysis of the Mixed State of Slurry Battery Materials, High Repeatability Particle Size Distribution Measurement of Colloidal Silica for CMP slurries,
Evaluation of Diameter (Thickness) and Aggregation/Dissociation State of Carbon Nanotube Dispersions,
Measurement of Particle Size Distribution of Nanocellulose using Centrifugal Sedimentation Method,
Analysis of Separate Mixed Samples of the Same Size but Different Materials
HORIBA Scientific
- Inquire
- 60 seconds from liquid filling, sampling and measurement to rinsing
- Inquire
HORIBA Scientific
- Approximately 10 mg to 5 g (Depending on the particle size, distribution, and density)
- Inquire
- Data can be obtained in as little as ten seconds.
- Maximizing Soy Milk Quality Attributes, Milk Homogenization Evaluation, Particle Analysis of Chocolate, Particle Characterization of Powdered Sugar, Particle Size of Paper Chemicals, Particle Analysis for Power Plant Emission Control, Particle Analysis of Road Materials, Particle Size Analysis of Cement
Malvern Panalytical
- 0.1 to 1000 µm
- Log Spaced State-of-the-Art Detector array
- < 10 s
- Inquire
Malvern Panalytical
- 0.1 to 2000 um
- 36 element log-spaced silicon diode detector array
- 30 s (Rapid mode), 60 min (Continuous mode)
- Inquire
Malvern Panalytical
- 0.3 nm to 15 µm
- Avalanche Photodiode
- Inquire
- Inquire
Malvern Panalytical
- 0.3 nm to 10 µm (diameter)2
- Inquire
- Inquire
- Inquire
Shimadzu
- 17 nm to 2,500 µm
- Inquire
- 1 sec
- Inquire
Shimadzu
- 7 nm to 800 µm
- Wing sensor ll
- 1 sec
- Inquire
Waters | Wyatt Technology
- Inquire
- High-gain, high-dynamic-range photodiodes at 18 angles for MALS; optional avalanche photodiode that may be placed at any of four angles for DLS.
Fluorescence-blocking filters available for use with analytes that fluoresce when illuminated at the MALS wavelength. - Depedent on LC separation
- With standard SEC/GPC or EclipseTM (FFF system): determination of distributions of molar mass, size, conformation, conjugation ratio and particle concentration.
With Calypso composition-gradient system: label-free characterization of biomolecular interactions including self- and hetero-association as well as non-specific interactions.
Select up to 5 products from above to compare or request more information.
Tags:
Please Login or Register to Create Tags