Dilatometer / Dilatometry (DIL)

Dilatometry (DIL) measures volume changes caused by physical and chemical processes. They are used in manufacturing, engineering, materials science, and chemistry labs. When working with a dilatometer, the first step is to load the sample into the machine. The sample is subjected to physical or chemical processes, most often in the form of heating from a furnace, and a sensor picks up on the volume changes.

Dilatometers can be used to calculate a material's coefficient of thermal expansion, softening point, glass transition temperature, Curie point, crystalline transformation, phase transition, and amount of shrinkage. When purchasing dilatometry equipment, it is important to consider the type of material that will be tested, the method of capture for measurements, and the software used.

Showing 17 of 17 products
  • <<
  • >>
Get Quote for All
Select up to 5 products from below to compare or request more information.
DIL 402 <i>Expedis Classic</i> Horizontal Dilatometer
NETZSCH-Gerätebau GmbH
  • Temperature Range:
    Inquire
  • Heating / Cooling Rates:
    0.001 to 50 K/min
  • Measuring Range:
    ± 5000 µm
  • Sample Length:
    Inquire
DIL 402 <i>Expedis Select</i> & <i>Supreme</i> Horizontal Dilatometer
NETZSCH-Gerätebau GmbH
  • Temperature Range:
    Inquire
  • Heating / Cooling Rates:
    0.001 to 100 K/min
  • Measuring Range:
    ± 10000 µm to ± 25000 µm
  • Sample Length:
    Inquire
TMA 402 <i>F1/F3 Hyperion</i>&#174; - Thermomechanical Analyzer - Vertical Dilatometer
NETZSCH-Gerätebau GmbH
  • Temperature Range:
    -150 °C to 1550 °C
  • Heating / Cooling Rates:
    Inquire
  • Measuring Range:
    +/- 2.5 mm
  • Sample Length:
    Up to 30 mm
Citations:
(1)
DIL 801 Single Sample Dilatomer
TA Instruments
  • Temperature Range:
    -160°C to 1650°C according to furnace type
  • Heating / Cooling Rates:
    Inquire
  • Measuring Range:
    Inquire
  • Sample Length:
    0 to 50 mm
DIL 802 Differential Dilatomer
TA Instruments
  • Temperature Range:
    -160°C to 1650°C according to furnace type
  • Heating / Cooling Rates:
    Inquire
  • Measuring Range:
    Inquire
  • Sample Length:
    0 to 50 mm
Citations:
(8)
DIL 803 Dual Sample Dilatometer
TA Instruments
  • Temperature Range:
    -160°C to 1650°C according to furnace type
  • Heating / Cooling Rates:
    Inquire
  • Measuring Range:
    Inquire
  • Sample Length:
    0 to 50 mm
DIL 805 Series Quenching Dilatometers
TA Instruments
  • Temperature Range:
    -150°C to 1300°C / 50°C to 1500°C
  • Heating / Cooling Rates:
    Inquire
  • Measuring Range:
    Inquire
  • Sample Length:
    Inquire
Citations:
(53)
DIL 806 Optical Dilatometer
TA Instruments
  • Temperature Range:
    -150°C to -600°C
  • Heating / Cooling Rates:
    Inquire
  • Measuring Range:
    Inquire
  • Sample Length:
    0.3 – 30 mm
Citations:
(6)
DIL 820 HT HiTemp Vertical Dilatometer
TA Instruments
  • Temperature Range:
    RT – 2000°C / 300°C – 2300°C
  • Heating / Cooling Rates:
    Inquire
  • Measuring Range:
    Inquire
  • Sample Length:
    0 to 25 mm
DIL 820 Series Vertical Dilatometer
TA Instruments
  • Temperature Range:
    RT – 1100°C / RT – 1500°C / 100 – 1700°C
  • Heating / Cooling Rates:
    Inquire
  • Measuring Range:
    Inquire
  • Sample Length:
    0 to 25 mm
Dilatometer Horizontal 831
TA Instruments
  • Temperature Range:
    Inquire
  • Heating / Cooling Rates:
    Inquire
  • Measuring Range:
    Inquire
  • Sample Length:
    0 to 25 mm
Heating Microscope Misura® 3 HSM/ HSML
TA Instruments
  • Temperature Range:
    RT – 1650 °C / RT – 1600 °C
  • Heating / Cooling Rates:
    Max Heating Rate - 0,1- 80 °C/min / 0,1- 30 °C/min
  • Measuring Range:
    Inquire
  • Sample Length:
    Inquire
High Resolution True Differential™ Horizontal Push Rod Dilatometer DIL 832
TA Instruments
  • Temperature Range:
    Inquire
  • Heating / Cooling Rates:
    Inquire
  • Measuring Range:
    Inquire
  • Sample Length:
    0 to 25 mm
HM 867 Heating Microscope
TA Instruments
  • Temperature Range:
    RT – 1600 °C
  • Heating / Cooling Rates:
    Heating Rate - 0,1 – 80 °C/min
  • Measuring Range:
    Inquire
  • Sample Length:
    Inquire
Misura 3 ODHT Optical Dilatometer
TA Instruments
  • Temperature Range:
    From RT up to 1650 °C
  • Heating / Cooling Rates:
    Inquire
  • Measuring Range:
    Inquire
  • Sample Length:
    Inquire
ODP 868 Optical Dilatometer with Heating Microscope and Fleximeter Modes
TA Instruments
  • Temperature Range:
    From RT up to 1650 °C
  • Heating / Cooling Rates:
    Heating Rate – 0,1 – 100 °C/min (200 °C/sec in Flash mode)
  • Measuring Range:
    Inquire
  • Sample Length:
    Up to 85mm
Citations:
(1)
Optical Fleximeter Misura® 3 FLEX
TA Instruments
  • Temperature Range:
    from RT up to 1600 °C (1750°C with HiTemp optional furnace)
  • Heating / Cooling Rates:
    Max Heating Rate – 0,01- 30 °C/min (20°C/min with HiTemp optional furnace)
  • Measuring Range:
    Inquire
  • Sample Length:
    Inquire
Select up to 5 products from above to compare or request more information.