Maldi TOF Mass Spectrometer (MALDI TOF MS)

MALDI TOF mass spectrometers (matrix-assisted laser desorption/ionization/time-of-flight) are amongst the most popular mass spec instruments in biology. They combine two technologies, the “soft” MALDI ionization source and the TOF mass analyzer. The latter measures an ion’s mass-to-charge ratio (m/z) by measuring the time it takes to reach a detector. The former volatilizes and ionizes those molecules using a laser, a target, and an organic compound called a matrix. In MALDI, a sample (for instance, a collection of tryptic peptides) is mixed with matrix, spotted and dried (crystallized) on the surface of a metal target plate. Upon irradiation with laser light, the matrix absorbs the energy and converts it to heat, which then causes the sample to ionize and explode off the plate into the mass analyzer. MALDI TOF mass spectrometers come in two basic flavors, MALDI TOF MS and MALDI TOF/TOF MS; the latter enables tandem MS (MS/MS) studies.

Showing 7 of 7 products
  • <<
  • >>
Get Quote for All
Select up to 5 products from below to compare or request more information.
Axima Assurance MALDI Time of Flight Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    MALDI
  • Mass Analyzer:
    TOF
  • Resolution:
    >5000 FWHM
  • Mass Range:
    1 kDa to 500 kDa
Citations:
(86)
Axima Confidence MALDI TOF Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    MALDI
  • Mass Analyzer:
    TOF
  • Resolution:
    5000 FWHM in linear mode; 15000 FWHM in reflectron mode
  • Mass Range:
    1 kDa to 500 kDa
Citations:
(144)
Figures:
(10)
Axima Performance MALDI TOF TOF Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    MALDI
  • Mass Analyzer:
    TOF/TOF
  • Resolution:
    >20,000 FWHM (Reflectron mode)
  • Mass Range:
    1 kDa to 500 kDa
Citations:
(299)
Figures:
(3)
AXIMA-iD Plus Microorganism Analysis
Shimadzu
  • Ionization Method(s):
    MALDI
  • Mass Analyzer:
    MALDI-TOF MS
  • Resolution:
    Inquire
  • Mass Range:
    Inquire
Citations:
(1)
MALDI-8030 Benchtop Linear Dual Polarity MALDI-TOF Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    MALDI
  • Mass Analyzer:
    TOF
  • Resolution:
    >5000 FWHM – ACTH 18-39 (m/z 2465)
  • Mass Range:
    m/z 1 - 500,000
MegaTOF Megadalton MALDI Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    MALDI
  • Mass Analyzer:
    TOF
  • Resolution:
    180 to 200 kDa
  • Mass Range:
    0.01 to 1.5 Mda
Citations:
(5)
OmegaTOF Benchtop High Mass MALDI-TOF Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    MALDI
  • Mass Analyzer:
    Time-of-Flight
  • Resolution:
    Inquire
  • Mass Range:
    m/z 1,000–1,500,000Da
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags
Shimadzu
Axima Confidence
5
10 Figures from 144 Publications
Shimadzu
Axima Performance
S8
3 Figures from 299 Publications
Showing 2 of 2 products
  • <<
  • >>
  • Shimadzu
Get the Latest Updates, Technology News and Trends, New Products, Promotions, Buying Tips, and More!

Note: Labcompare disclaims any information on this site.