Infrared Spectrophotometer

An infrared spectrophotometer is an analytical instrument used to identify materials including organic polymers. Infrared spectrophotometers record the relative amount of energy as a function of the wavelength/frequency of the infrared radiation when it passes through a sample. Therefore, chemical structures of different samples will reflect differences in the IR absorption spectrum allowing for identification of a sample. Unlike a dispersive spectrometer, an FTIR spectrometer or FTIR spectrophotometer is used to simultaneously obtain spectral data of a sample. It does this by using an interferometer to collect the interferogram, also known as the raw data/signal format, which can then be translated into the infrared spectrum of the sample by means of a fourier transform algorithm. As a result, there are many advantages including greater signal-to-noise ratio, high resolution, higher throughput, and a short wavelength limit. FTIR spectrometers can be used in a variety of industries including environmental, pharmaceutical, and petrochemical.

Find, compare, and request a quote for infrared spectrophotometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

Your search for FTIR spectrophotometer returned 19 results.
Showing 20 of 20 products
  • <<
  • >>
Get Quote for All
Select up to 5 products from below to compare or request more information.

Sponsored Products

4300 Handheld FTIR
Agilent Technologies
  • Wavelength Range:
    5,200 to 650 cm-1
  • Signal-to-Noise Ratio:
    Inquire
  • Resolution:
    4 to 16 cm -1
  • Optical System:
    Inquire
Citations:
(20)
Cary 630 FTIR Spectrometer
Agilent Technologies
  • Resolution:
    ≤2 cm-1
Citations:
(>1k)
Figures:
(6)
4500 Series Portable FTIR
Agilent Technologies
  • Wavelength Range:
    4000 to 650 cm-1
  • Signal-to-Noise Ratio:
    Inquire
  • Resolution:
    2 to 16 cm-1
  • Optical System:
    Inquire
EM27 Open Path FTIR Spectrometer
Bruker Optics
  • Wavelength Range:
    Inquire
  • Signal-to-Noise Ratio:
    Inquire
  • Resolution:
    Inquire
  • Optical System:
    Inquire
ALPHA II FTIR Spectrometer
Bruker Optics
  • Wavelength Range:
    350 to 8000 cm-1 with standard KBr beamsplitter
    500 to 6000 cm -1 option High Humidity ZnSe optics
  • Signal-to-Noise Ratio:
    > 55,000:1
  • Resolution:
    Better than 2 cm-1, optional better than 0.75 cm-1
  • Optical System:
    KBr windows and beamsplitter, optional High Humidity optics with ZnSe beamsplitter and ZnSe windows
Citations:
(33)
VERTEX Series FTIR Spectrometers
Bruker Optics
  • Wavelength Range:
    10 to 28,000 cm-1 (far IR or terahertz, mid, near IR, up to the visible or UV)
  • Signal-to-Noise Ratio:
    Inquire
  • Resolution:
    better than 0.2 cm-1
  • Optical System:
    Vacuum Optics
Citations:
(213)
Figures:
(1)
IFS 125 Series FTIR Spectrometers
Bruker Optics
  • Wavelength Range:
    5 to >50,000 cm-1 (far-IR to UV)
  • Signal-to-Noise Ratio:
    Inquire
  • Resolution:
    0.008 cm-1
  • Optical System:
    Inquire
Citations:
(5)
5500 Series Compact FTIR
Agilent Technologies
  • Wavelength Range:
    4,000 to 650 cm-1
  • Signal-to-Noise Ratio:
    Inquire
  • Resolution:
    2 to 16 cm -1
  • Optical System:
    Low Powered Solid State Laser
IRXross FTIR Spectrophotometer
Shimadzu
  • Wavelength Range:
    7,800 to 350 cm-1
  • Signal-to-Noise Ratio:
    55,000:1
  • Resolution:
    0.25, 0.5, 1, 2, 4, 8, 16 cm-1
  • Optical System:
    Single Beam
Nicolet&#8482; Apex FTIR Spectrometer
Thermo Fisher Scientific
  • Wavelength Range:
    Depends on model
  • Signal-to-Noise Ratio:
    50,000:1 (guaranteed)
    60,000:1 (typical)
  • Resolution:
    Better than 0.25 cm -1
  • Optical System:
    Inquire
FTIR Plastic Analyzer
Shimadzu
  • Wavelength Range:
    Inquire
  • Signal-to-Noise Ratio:
    Inquire
  • Resolution:
    Inquire
  • Optical System:
    Inquire
Nicolet&#8482; Summit&#8482; OA FTIR Spectrometer
Thermo Fisher Scientific
  • Wavelength Range:
    6000 to 650 cm-1
  • Signal-to-Noise Ratio:
    Inquire
  • Resolution:
    Inquire
  • Optical System:
    Inquire
Nicolet&#8482; iS50 FTIR Spectrometer
Thermo Fisher Scientific
  • Wavelength Range:
    15 to 27,000 cm-1
  • Signal-to-Noise Ratio:
    Inquire
  • Resolution:
    Better than 0.09 cm-1
  • Optical System:
    Inquire
Nicolet&#8482; Summit&#8482; X FTIR Spectrometer
Thermo Fisher Scientific
  • Wavelength Range:
    8000 to 350 cm-1
  • Signal-to-Noise Ratio:
    Inquire
  • Resolution:
    Better than 0.6 cm-1
  • Optical System:
    Inquire
ERASPEC Oil Lubricant Monitor
eralytics GmbH
  • Wavelength Range:
    Inquire
  • Signal-to-Noise Ratio:
    Inquire
  • Resolution:
    Inquire
  • Optical System:
    Inquire
FT/IR-6X FTIR Spectrometer
JASCO
  • Wavelength Range:
    7,800 to 350 cm-1
  • Signal-to-Noise Ratio:
    47,000 : 1
  • Resolution:
    0.25, 0.5, 1.0, 2, 4, 8, 16 cm-1
  • Optical System:
    Inquire
FT/IR-8X FTIR Spectrometer
JASCO
  • Wavelength Range:
    7,800 to 350 cm-1
  • Signal-to-Noise Ratio:
    55,000 : 1
  • Resolution:
    0.25, 0.5, 1.0, 2, 4, 8, 16 cm-1
  • Optical System:
    Inquire

Other Infrared Spectrophotometer Products

INVENIO FT-IR Spectrometer
Bruker Optics
  • Wavelength Range:
    Inquire
  • Signal-to-Noise Ratio:
    60’000:1 1 min sample measurement, 4 cm-1, peak-to-peak
  • Resolution:
    < 0.085 cm-1
  • Optical System:
    Inquire
Citations:
(23)
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags
  • <<
  • >>
Agilent Technologies
Cary 630
2
6 Figures from 1543 Publications
Bruker Optics
VERTEX 80 / VERTEX 80v
Appendix 1—1
1 Figure from 213 Publications
Showing 20 of 20 products
  • <<
  • >>
  • Agilent Technologies
  • Bruker Optics
  • eralytics GmbH
  • JASCO
  • Shimadzu
  • Thermo Fisher Scientific
Get the Latest Updates, Technology News and Trends, New Products, Promotions, Buying Tips, and More!