In the chemistry, pharmaceutical, materials testing, and petrochemical industries, the ability to quickly analyze and identify a substance is key. One solution is to use a Raman spectrometer. By taking advantage of the scattering of laser light hitting a sample, a Raman spectrometer can read the subtle energy shift in the scattered light caused by the vibration of the substance undergoing analysis. Raman spectrometers typically employ diode or gas lasers of 532 or 785 nm. For applications like forensics, where samples are often contaminated, some Raman spectrometers offer wavelengths of 1064 to filter fluorescence at the cost of overall sensitivity.
Considerations for purchasing a Raman spectrometer
Detectors for Raman spectrometers include CCD arrays, InGaAs, or Ge types. Some Raman spectrometer systems are coupled with high-end microscopes for micro molecular analysis.
Click on the links below to discover and compare lab Raman spectrometers from various manufacturers:
Get Quote for All
Select up to 5 products from below to compare or request more information.
- Laser Sources: Inquire
- Detector(s): Inquire
- Resolution: < 4 cm-1
- Spectral Range: Inquire
- Laser Sources: 532, 785, 830 nm laser
- Detector(s): TE Cooled Linear Array
- Resolution: 3 to 4.5 cm-1 (varies with model, wavelength)
- Spectral Range: 65 to 4000 cm-1
- Laser Sources: 532, 785, 830 nm laser
- Detector(s): Back-thinned CCD Array
- Resolution: 3 to 4.5 cm-1 (varies with wavelength)
- Spectral Range: 65 to 4000 cm-1
- Laser Sources: 532nm, 785nm laser
- Detector(s): TE Cooled, Back-thinned, 2D Binning CCD
- Spectral Range: 65 to 3750 cm-1
- Laser Sources: 532, 785 nm laser
- Detector(s): TE Cooled Linear Array
- Resolution: 10 or 15 cm-1 (varies with wavelength)
- Spectral Range: 65 to 4000 cm-1
- Laser Sources: 785 nm laser
- Detector(s): TE Cooled Linear CCD Array
- Resolution: 9 cm-1
- Spectral Range: 176 to 2900 cm-1 (Option to Extend Range to 3200 cm-1)
- Laser Sources: 785 nm Frequency Stabilized, Narrow Linewidth Diode Laser
- Detector(s): TEC Regulated Linear CCD Spectograph
- Resolution: 6 to 7 cm-1
- Spectral Range: 100 to 2700 cm-1 or 250 to 2350 cm-1 (depending on mode)
- Laser Sources: NIR, 785 nm Frequency Stabilized, Narrow Linewidth Diode Laser and Visible, DPSS 532 nm Laser
- Detector(s): TEC Cooled CCD Camera (-50C)
- Resolution: 10 cm-1
- Spectral Range: 100 to 3000 cm-1 (785 nm) or 250 to 4300 cm-1 (532 nm)
- Laser Sources: NIR, 785 nm Frequency Stabilized, Narrow Linewidth Diode Laser
- Detector(s): TEC Cooled CCD Camera (-50C)
- Resolution: 4.5 to 6.5 cm-1 (depending on spectral range)
- Spectral Range: 100 to 3300 cm-1, (depending on option)
- Laser Sources: 785 nm Frequency Stabilized, Narrow Linewidth Diode Laser
- Detector(s): TEC Regulated Linear CCD Array
- Resolution: 4.5 to 6.5 cm-1 (depending on spectral range)
- Spectral Range: 100 to 3300 cm-1, (depending on option)
- Laser Sources: 785 nm Frequency Stabilized, Narrow Linewidth Diode Laser
- Detector(s): TEC Regulated Linear CCD Array
- Resolution: 4.5 to 6.5 cm-1 (depending on spectral range)
- Spectral Range: 100 to 3300 cm-1, (depending on option)
- Laser Sources: 785 nm Frequency Stabilized, Narrow Linewidth Diode Laser
- Detector(s): TEC Regulated Linear CCD Array
- Resolution: 9 cm-1 (standard) or 5 cm-1 (optional)
- Spectral Range: 250 to 2350 cm-1
- Laser Sources: NIR, 785 nm Frequency Stabilized, Narrow Linewidth Diode Laser
- Detector(s): TEC Cooled CCD Camera (-60C)
- Resolution: 7 cm-1 (Optional: 5 cm-1)
- Spectral Range: 250 to 2350 cm-1 (785 nm) or 100 to 3300 cm-1
- Laser Sources: NIR, 785 nm Frequency Stabilized, Narrow Linewidth Diode Laser
- Detector(s): TEC Cooled CCD Camera (-60C)
- Resolution: 4.5 to 6.5 cm-1 (depends on model)
- Spectral Range: 100 to 3300 cm-1, (depending on option)
- Laser Sources: NIR, 785 nm Frequency Stabilized, Narrow Linewidth Diode Laser
- Detector(s): TEC Cooled CCD Camera (-60C)
- Resolution: 10 cm-1 (Optional: 6 cm-1)
- Spectral Range: 250 to 3200 cm-1 (785 nm)
- Laser Sources: VIS-NIR laser or UV laser
- Detector(s): 4-Stage Peltier Cooled CCD Detector (UV-NIR range, 1024 × 255 pixel)
- Resolution: 1 cm-1
- Spectral Range: 10 to 8000 cm-1
- Laser Sources: VIS-NIR laser or UV laser
- Detector(s): 4-Stage Peltier Cooled CCD Detector (UV-NIR range, 1024 × 255 pixel)
- Resolution: 0.7 cm-1
- Spectral Range: 5 to 8000 cm-1
- Laser Sources: 532 nm or 785 nm Compact Laser
- Detector(s): Peltier Cooled CCD Detector
- Resolution: 1 to 4 cm-1 (depending on model)
- Spectral Range: 200 to 3200 cm-1
Kaiser Optical Systems, Inc.
- Laser Sources: Inquire
- Detector(s): Inquire
- Resolution: Inquire
- Spectral Range: Inquire
Kaiser Optical Systems, Inc.
- Laser Sources: Invictus NIR Laser (532, 632.8 or 785 nm)
- Detector(s): TE-cooled CCD
- Resolution: 2 to 10 cm-1 (depending on laser source and grating)
- Spectral Range: 675 to 893 cm-1 (Laser-dependent)
Kaiser Optical Systems, Inc.
- Laser Sources: Diode Laser
- Detector(s): InGaAs Array Detector
- Resolution: Inquire
- Spectral Range: Inquire
Kaiser Optical Systems, Inc.
- Laser Sources: NIR Laser
- Detector(s): Inquire
- Resolution: Inquire
- Spectral Range: Inquire
Kaiser Optical Systems, Inc.
- Laser Sources: Inquire
- Detector(s): Inquire
- Resolution: Inquire
- Spectral Range: Inquire
Kaiser Optical Systems, Inc.
- Laser Sources: Inquire
- Detector(s): Inquire
- Resolution: Inquire
- Spectral Range: Inquire
Kaiser Optical Systems, Inc.
- Laser Sources: Invictus 532 nm VIS Laser
- Detector(s): Inquire
- Resolution: Inquire
- Spectral Range: Inquire
LTB Lasertechnik Berlin GmbH
- Laser Sources: Inquire
- Detector(s): CCD (USB) or EMCCD
- Resolution: 36 to 133 pm (FWHM)
- Spectral Range: 220 to 800 nm
LTB Lasertechnik Berlin GmbH
- Laser Sources: Inquire
- Detector(s): CCD or ICCD, EMCCD, CMOS
- Resolution: 24 to 90 pm (or 22 to 83 pm)
- Spectral Range: 220 to 800 nm (or 200 to 750 nm)
LTB Lasertechnik Berlin GmbH
- Laser Sources: Inquire
- Detector(s): CCD or ICCD
- Resolution: 6 to 80 pm (depending on model, detector, grating, prism and slit width)
- Spectral Range: 190 to 950 nm (depending on model, detector, grating and prism)
- Laser Sources: Wavelength excitation laser
- Detector(s): CCD detector
- Resolution: 6 to 10 cm-1 (depending on model)
- Spectral Range: 200 to 4500 cm-1 (Depending on model)
- Laser Sources: Inquire
- Detector(s): Inquire
- Resolution: 10 cm-1
- Spectral Range: 200 to 2400 cm-1
- Laser Sources: Inquire
- Detector(s): Hamamatsu S7031-1006
- Resolution: 6 to 19 cm-1 (Slit dependant)
- Spectral Range: 200 to 1100 nm
- Laser Sources: Inquire
- Detector(s): 2D detectors
- Resolution: < 0.05 nm (camera dependent) 0.05="" nm="" (camera=""> 0.05 nm (camera dependent)>
- Spectral Range: Inquire
- Laser Sources: Inquire
- Detector(s): Inquire
- Resolution: 0.5 nm (at 400 nm) and 2 nm (at 2000 nm)
- Spectral Range: 350 nm to 2500 nm
- Laser Sources: 785 to 830 nm Lasers
- Detector(s): CCD Detectors
- Resolution: 5 cm-1
- Spectral Range: 126 to 2340 cm-1 (or 126 to 2040 cm-1)
- Laser Sources: 532, 785 or 1064 nm Laser
- Detector(s): TE Cooled CCD or InGaAs Array
- Resolution: 10 to 12 cm-1
- Spectral Range: 400 to 1850 cm-1
- Laser Sources: 532, 785 or 1064 nm Laser
- Detector(s): TE Cooled CCD or InGaAs Array
- Resolution: 10 to 12 cm-1
- Spectral Range: 400 to 1850 cm-1
- Laser Sources: 532, 785 or 1064 nm Laser
- Detector(s): Uncooled CCD
- Resolution: 15 to 17 cm-1
- Spectral Range: 400 to 1850 cm-1
- Laser Sources: 532 nm Diode-pumped, solid state (DPSS), 633 nm HeNe gas, 780 nm Frequency-stabilized single mode diode laser, 780 nm Multiple transverse mode narrow-spectrum diode
- Detector(s): Grating
- Resolution: 3 or 5 cm-1
- Spectral Range: 532 to 780 nm
Thermo Scientific (Portable Analytical Instruments)
- Laser Sources: 785 nm Laser
- Detector(s): Inquire
- Resolution: 8 to 10.5 cm-1 (FWHM) across range
- Spectral Range: 250 cm-1 to 2875 cm-1
- Laser Sources: Inquire
- Detector(s): Inquire
- Resolution: 4 cm-1
- Spectral Range: 532 to 1064 nm
Select up to 5 products from above to compare or request more information.
Tags:
Please Login or Register to Create Tags