UV VIS NIR Spectrometer

Showing 40 of 47 products
Get Quote for All
Select up to 5 products from below to compare or request more information.
Mechelle 5000 Spectrograph

Mechelle 5000 Spectrograph

Andor Technology

  • Wavelength Range: 200 to 975 nm
  • Detector(s): Inquire
  • Resolution: < 4="" />-1
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
Shamrock 163 Imaging Spectrograph
  • Wavelength Range: Inquire
  • Detector(s): iDus CCD detector
  • Resolution: 0.17 to 2.0 nm
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
Shamrock 303 Imaging Spectrograph
  • Wavelength Range: 170 nm to 10 um
  • Detector(s): EMCCD, CCD and ICCD Spectroscopy Detector Systems
  • Resolution: 0.1 or 0.05 nm
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
Shamrock 500 Imaging Spectrometer
  • Wavelength Range: Inquire
  • Detector(s): CCD, EMCCD, ICCD and InGaAs
  • Resolution: 0.05 nm
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
Shamrock 750 Spectrograph

Shamrock 750 Spectrograph

Andor Technology

  • Wavelength Range: Inquire
  • Detector(s): CCD, EMCCD, ICCD and InGaAs
  • Resolution: 0.03 nm
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
1250M Research Spectrometer

1250M Research Spectrometer

HORIBA Scientific

  • Wavelength Range: 0 to 1500 nm
  • Detector(s): Compatible with most CCDs
  • Resolution: 0.006 nm
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
FHR Spectrometers

FHR Spectrometers

HORIBA Scientific

  • Wavelength Range: 0 to 1500 nm
  • Detector(s): Inquire
  • Resolution: 0.008 nm (FHR1000) / 0.016 nm (FHR640)
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
High Resolution Research Spectrometer (1000M, Series II)
  • Wavelength Range: 0 to 1500 nm
  • Detector(s): CCD, Single Channel Detectors, PMT
  • Resolution: 0.008 nm
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
iHR320 Imaging Spectrometer

iHR320 Imaging Spectrometer

HORIBA Scientific

  • Wavelength Range: 185 nm to Far Infrared
  • Detector(s): CCD or PMT
  • Resolution: 0.06 nm
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
iHR550 Imaging Spectrometer

iHR550 Imaging Spectrometer

HORIBA Scientific

  • Wavelength Range: 185 nm to Far Infrared
  • Detector(s): CCD or PMT
  • Resolution: 0.025 nm
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
MicroHR Manual Short Focal Length Spectrometer
  • Wavelength Range: 150 nm to 15 um
  • Detector(s): Quick-Align CCD Adapter
  • Resolution: 0.3 nm
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
MicroHR Motorized Short Focal Length Spectrometer
  • Wavelength Range: 150 nm to 15 um
  • Detector(s): Dual Detector Ports
  • Resolution: 0.25 nm at 400 nm
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
ARYELLE 150 Extremely Compact and Cost-efficient High-resolution Echelle Spectrometer
  • Wavelength Range: 220 to 800 nm
  • Detector(s): CCD (USB) or EMCCD
  • Resolution: 36 to 133 pm (FWHM)
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
ARYELLE 200 Compact High-resolution Echelle Spectrometer
  • Wavelength Range: 220 to 800 nm (or 200 to 750 nm)
  • Detector(s): CCD or ICCD, EMCCD, CMOS
  • Resolution: 24 to 90 pm (or 22 to 83 pm)
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
ARYELLE 400 Powerful High-resolution Echelle Spectrometer
  • Wavelength Range: 190 to 950 nm (depending on model, detector, grating and prism)
  • Detector(s): CCD or ICCD
  • Resolution: 6 to 80 pm (depending on model, detector, grating, prism and slit width)
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
DEMON High Resolution and Optical Throughput Echelle Spectrometer
  • Wavelength Range: 190 to 900 nm (175 to 1100 nm on request)
  • Detector(s): CCD Line Array Detector (1024 pixels) or ICCD
  • Resolution: Inquire
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
HR2000+ High-Resolution Spectrometer
  • Wavelength Range: 200 to 1100 nm
  • Detector(s): Sony ILX511B Linear Silicon CCD Array
  • Resolution: ~0.035 to 6.8 nm (FWHM)
  • Signal-to-Noise Ratio: 250:1
Compare or Get Quote for selected.
HR2000+CG High-Speed Composite Grating Spectrometer
  • Wavelength Range: 200 to 1100 nm
  • Detector(s): Sony ILX511B Linear Silicon CCD Array
  • Resolution: 1.0 nm (FWHM)
  • Signal-to-Noise Ratio: 250:1
Compare or Get Quote for selected.
HR2000+ES High-resolution Spectrometer for Enhanced Sensitivity
  • Wavelength Range: 200 to 1100 nm (grating-dependent)
  • Detector(s): Sony ILX511B Linear Silicon CCD Array
  • Resolution: ~1.33 to 6.8 nm (FWHM)
  • Signal-to-Noise Ratio: 250:1
Compare or Get Quote for selected.
HR4000 High-Resolution Spectrometer
  • Wavelength Range: 200 to 1100 nm
  • Detector(s): Toshiba TCD1304AP Linear CCD Array
  • Resolution: ~0.02 to 8.4 nm (FWHM)
  • Signal-to-Noise Ratio: 300:1
Compare or Get Quote for selected.
HR4000CG Composite-Grating (CG) Spectrometer
  • Wavelength Range: 200 to 1100 nm
  • Detector(s): Toshiba TCD1304AP Linear CCD Array
  • Resolution: 0.75 nm (FWHM)
  • Signal-to-Noise Ratio: 300:1
Compare or Get Quote for selected.
QE65 Pro High-sensitivity Spectrometer
  • Wavelength Range: 780 to 1100 nm (Grating dependent)
  • Detector(s): Hamamatsu S7031-1006
  • Resolution: 6 to 19 cm-1 (Slit dependant)
  • Signal-to-Noise Ratio: 1000:1 (at full signal)
Compare or Get Quote for selected.
QE65 Pro-ABS Absorbance Spectometer
  • Wavelength Range: 200 to 950 nm
  • Detector(s): Hamamatsu S7031-1006
  • Resolution: 0.14 to 7.7 nm FWHM
  • Signal-to-Noise Ratio: 1000:1 (at full signal)
Compare or Get Quote for selected.
QE65 Scientific-Grade Spectrometer
  • Wavelength Range: 200 to 1100 nm (Detector), Grating dependent (Spectroscopic)
  • Detector(s): Hamamatsu FFT-CDD S7031-1006 (low etaloning)
  • Resolution: ~0.14 to 7.7 nm (FWHM)
  • Signal-to-Noise Ratio: 1000:1 (at full signal)
Compare or Get Quote for selected.
RaySphere Solar Simulator Analyzer
  • Wavelength Range: 350 to 1100 nm or 300 to 1700 nm (depending on model)
  • Detector(s): TEC stabilized Hamamatsu CCD or InGaAs Senors
  • Resolution: 1100 to 1700 nm: 2.5 nm (FWHM) or 300 to 1100 nm: 1.9 nm (FWHM)
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
STS Microspectrometer

STS Microspectrometer

Ocean Optics

  • Wavelength Range: 350 to 800 nm (VIS), 650 to1100 nm (NIR)
  • Detector(s): ELIS1024, 1024 Pixel Linear CMOS
  • Resolution: 1.5 nm FWHM (w/ 25 um slit)
  • Signal-to-Noise Ratio: >1500:1 (at maximum signal)
Compare or Get Quote for selected.
Torus Miniature Spectrometer
  • Wavelength Range: 360 to 825 nm
  • Detector(s): Sony ILX511B
  • Resolution: ≤2.0 nm FWHM (over the spectral range)
  • Signal-to-Noise Ratio: 250:1 (at full signal)
Compare or Get Quote for selected.
USB2000+ Miniature Fiber Optic Spectrometer
  • Wavelength Range: 200 to 1100 nm
  • Detector(s): Sony ILX511B Linear Silicon CCD Array
  • Resolution: ~0.3 to 10.0 nm (FWHM)
  • Signal-to-Noise Ratio: 250:1
Compare or Get Quote for selected.
USB4000 Miniature Fiber Optic Spectrometer
  • Wavelength Range: 200 to 1100 nm
  • Detector(s): Toshiba TCD1304AP Linear CCD Array
  • Resolution: ~0.3 to 10.0 nm (FWHM, grating-dependent)
  • Signal-to-Noise Ratio: 300:1
Compare or Get Quote for selected.
XR Extended Wavelength Spectrometers
  • Wavelength Range: 200 to 1025 nm
  • Detector(s): Inquire
  • Resolution: 1.7 to 2.1 nm (depending on model)
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
CLARiTY 1000 UV/Visible Spectrometer
  • Wavelength Range: 240 to 800 nm
  • Detector(s): PMTs
  • Resolution: down to 0.3 nm
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
CLARiTY 11 Vis/NIR Spectrometer
  • Wavelength Range: 400 to 650 nm (extendible to NIR)
  • Detector(s): FT-Vis from 400 to 1100 nm
  • Resolution: 5 x 10^5 AU
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
CLARiTY 17 UV/Visible Spectrometer
  • Wavelength Range: 240 to 800 nm (extendible to NIR)
  • Detector(s): PMTs (for UV/Vis), InGaAs (for NIR)
  • Resolution: 0.1 nm to 20 nm
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
QuantaMaster 50 NIR with InGaAs Spectrofluorometer

QuantaMaster 50 NIR with InGaAs Spectrofluorometer

Photon Technology International, Inc.

  • Wavelength Range: 500 to 1700 nm
  • Detector(s): Thermo-electronically Cooled InGaAs TE Detector
  • Resolution: 0.25 nm (excitation) and 0.5 (emission)
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
QuantaMaster 60 NIR with PMT Spectrofluorometer

QuantaMaster 60 NIR with PMT Spectrofluorometer

Photon Technology International, Inc.

  • Wavelength Range: 300 to 1700 nm
  • Detector(s): NIR PMT Detector
  • Resolution: +/- 0.5 nm (excitation) and 1.0 (emission)
  • Signal-to-Noise Ratio: 10000:1 or better
Compare or Get Quote for selected.
Acton Series LS 785 High Throughput NIR Raman Spectrometer
  • Wavelength Range: 785 to 1050 nm
  • Detector(s): CCD Detectors
  • Resolution: 5 cm-1
  • Signal-to-Noise Ratio: Inquire
Compare or Get Quote for selected.
Exemplar LS Low Straylight Smart CCD Spectrometer
  • Wavelength Range: 200 to 850 nm
  • Detector(s): Response Enhanced Linear CCD Array
  • Resolution: < 0.4 nm
  • Signal-to-Noise Ratio: 295:1
Inquire
Compare for selected.
Exemplar Plus High Performance Smart Spectrometer
  • Wavelength Range: 190 to 1100 nm
  • Detector(s): Back-thinned CCD Array
  • Resolution: 0.1 to 10.00 nm
  • Signal-to-Noise Ratio: 540:1
Inquire
Compare for selected.
Exemplar Smart CCD Spectrometer
  • Wavelength Range: 200 to 1050 nm
  • Detector(s): Response Enhanced Linear CCD Array
  • Resolution: 0.5 to 4.0 nm
  • Signal-to-Noise Ratio: 295:1
Inquire
Compare for selected.
Glacier X TE Cooled CCD Spectrometer
  • Wavelength Range: 200 to 1050 nm
  • Detector(s): Response Enhanced Linear CCD Array
  • Resolution: 0.2 to 4.0 nm
  • Signal-to-Noise Ratio: N/A
Inquire
Compare for selected.
Select up to 5 products from above to compare or request more information.
Showing 40 of 47 products

Tags:

Please Login or Register to Create Tags
  • Andor Technology
  • B&W Tek Inc
  • BaySpec, Inc.
  • HORIBA Scientific
  • LTB Lasertechnik Berlin GmbH
  • Ocean Optics
  • Olis, Inc.
  • P&P Optica
  • Photon Technology International, Inc.
  • Princeton Instruments
  • Qubit Systems Inc.