Raman Microscope / Confocal Raman Microscopes

In Raman microscopy, also called confocal Raman microscopy, an optical microscope and a Raman spectrometer are combined into one instrument in order to provide high resolution images of small samples. This high resolution imaging has applications that include materials science, earth science, cell biology, medicine, cosmetics, and art analysis. A Raman microscope consists of a basic optical microscope, a Raman spectrometer, a laser, a light source, and a detector such as a CCD camera. The optical microscope uses light to magnify and identify samples while the Raman spectrometer scatters light and measures the excitation vibration. When selecting a microscope, it is important to consider the qualities of each of the microscope's components and their optimal configuration for a particular application.

Find, compare, and request a quote for Raman and confocal Raman microscopes across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

Your search for Raman microscopes returned 19 results.
Showing 19 of 19 products
  • <<
  • >>
Get Quote for All
Select up to 5 products from below to compare or request more information.

Sponsored Products

DXR3xi Raman Imaging Microscope
Thermo Fisher Scientific
  • Measurement Mode(s):
    Inquire
  • Detector(s):
    Inquire
  • Laser Sources:
    Inquire
RamanScopeIII FT-Raman Microscope
Bruker Optics
  • Measurement Mode(s):
    FT-Raman spectrometer
  • Detector(s):
    InGaAs detector or Ge diode detector
  • Laser Sources:
    Diode-pumped, air-cooled Nd:YAG laser source
RM5 Raman Microscope
Edinburgh Instruments Ltd
  • Measurement Mode(s):
    Confocal Raman, Photoluminescence, Temperature Control, Automatic Mapping, Polarisation
  • Detector(s):
    High sensitivity ultra low noise CCD
    1650 x 200 pixels, TE-cooled -60oC (standard) OR
    2000 x 256 pixels, TE-cooled -60oC (enhanced sensitivity and spectral range) OR EMCCD (fast mapping applications) OR NIR Detector Array (spectral range up to 1700 nm)
  • Laser Sources:
    Up to 3 narrow-band lasers including: 532 nm, 638 nm, 785 nm Other wavelengths available on request
Citations:
(1)
RISE&#8482; &#8211; Raman Imaging and Scanning Electron Microscope
WITec GmbH
  • Measurement Mode(s):
    Correlative Raman-SEM Imaging
  • Detector(s):
    CCD/EMCCD
  • Laser Sources:
    Multiple Laser Sources
Citations:
(9)
alpha300 Ri Inverted Confocal Raman Imaging Microscope
WITec GmbH
  • Measurement Mode(s):
    Confocal Raman Imaging Microscopy
  • Detector(s):
    CCD/EMCCD
  • Laser Sources:
    Multiple Laser Sources
Citations:
(2)
SENTERRA II Dispersive Raman Microscope
Bruker Optics
  • Measurement Mode(s):
    Confocal Raman, Automatic Fluorescence
  • Detector(s):
    Grating
  • Laser Sources:
    Multiple laser sources
RMS1000 Raman Microscope
Edinburgh Instruments Ltd
  • Measurement Mode(s):
    Confocal Raman, FLIM, Photoluminescence, Temperature Control, Automatic Mapping, Polarisation
  • Detector(s):
    High sensitivity ultra low noise spectroscopy CCD
    1650 x 200 pixels, TE-cooled -60°C (standard) OR 2000 x 256 pixels, TE-cooled -60°C (enhanced sensitivity and spectral range) OR EMCCD (fast mapping applications) OR NIR Detector Array (spectral range up to 1700 nm)
  • Laser Sources:
    Up to 5 integrated narrow-band lasers: 532 nm, 638 nm, 785 nm typically used. Additional lasers from UV to NIR are available. External lasers can be integrated.
HYPERION Series Microscopes
Bruker Optics
  • Measurement Mode(s):
    Inquire
  • Detector(s):
    Inquire
  • Laser Sources:
    Inquire
Citations:
(202)
ParticleScout&#8482; Automated Microparticle Analysis Tool
WITec GmbH
  • Measurement Mode(s):
    Confocal Raman Microscopy
  • Detector(s):
    CCD/EMCCD
  • Laser Sources:
    Multiple Laser Sources
Citations:
(3)
RTS-Mini Confocal Raman Microscope
Zolix Instruments Co., Ltd.
  • Measurement Mode(s):
    Confocal Raman Imaging
  • Detector(s):
    Inquire
  • Laser Sources:
    Inquire
NRS-4500 Confocal Raman Microscope
JASCO
  • Measurement Mode(s):
    Backscattering
  • Detector(s):
    Air-cooled Peltier CCD detector (Max.-60°C)
    1650 x 200 pixel, 16 µm x 16 µm, Visible to NIR
  • Laser Sources:
    Standard: 532 nm, 20 mW
    Optional lasers: 405, 442, 457, 488, 514.5, 532, 633, 785, 1064 nm, etc.
    *Red wavelengths are recommended lasers.
    *In case of 1064 nm, detector needs to be changed to InGaAs.
Citations:
(32)
TrueSurface&#8482; Microscopy Topographic Imaging System
WITec GmbH
  • Measurement Mode(s):
    Confocal Raman Imaging
  • Detector(s):
    Optical Profilometer
  • Laser Sources:
    Multiple Laser Sources
Citations:
(8)
NRS-5500 Confocal Raman Microscope
JASCO
  • Measurement Mode(s):
    Backscattering
  • Detector(s):
    4-Stage Peltier Cooled CCD Detector (UV-NIR range, 1,024 × 255 pixel)
  • Laser Sources:
    Standard: 532 nm, 50 mW
    Optional lasers: 244, 266, 325, 355, 442, 488, 514.5, 633, 660, 785, 1064 nm, etc.
    *Red wavelengths are recommended lasers.
    *In case of 1064 nm, detector needs to be changed to InGaAs.
Citations:
(172)
NRS-7500 Confocal Raman Microscope
JASCO
  • Measurement Mode(s):
    Backscattering
  • Detector(s):
    4-Stage Peltier Cooled CCD Detector (UV-NIR range, 1,024 × 255 pixel)
  • Laser Sources:
    Standard: 532 nm, 50 mW
    Optional lasers: 244, 266, 325, 355, 442, 488, 514.5, 633, 660, 785, 1064 nm, etc.
    *Red wavelengths are recommended lasers.
    *In case of 1064 nm, detector needs to be changed to InGaAs.
Citations:
(28)
AIRsight Infrared/Raman Microscope
Shimadzu
  • Measurement Mode(s):
    Infrared and Raman
  • Detector(s):
    T2SL and TGS detector
  • Laser Sources:
    Equipped standard with 532 nm and 785 nm lasers
NRS-5600 Confocal Raman Microscope
JASCO
  • Measurement Mode(s):
    Backscattering
  • Detector(s):
    4-Stage Peltier Cooled CCD Detector (UV-NIR range, 1,024 × 255 pixel)
  • Laser Sources:
    Standard: 532 nm, 50 mW
    Optional lasers: 244, 266, 325, 355, 442, 488, 514.5, 633, 660, 785, 1064 nm, etc.
    *Red wavelengths are recommended lasers.
    *In case of 1064 nm, detector needs to be changed to InGaAs.
NRS-7600 Confocal Raman Microscope
JASCO
  • Measurement Mode(s):
    Backscattering
  • Detector(s):
    4-Stage Peltier Cooled CCD Detector (UV-NIR range, 1,024 × 255 pixel)
  • Laser Sources:
    Standard: 532 nm, 50 mW
    Optional lasers: 244, 266, 325, 355, 442, 488, 514.5, 633, 660, 785, 1064 nm, etc.
    *Red wavelengths are recommended lasers.
    *In case of 1064 nm, detector needs to be changed to InGaAs.
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags
  • <<
  • >>
WITec GmbH
alpha300 R
4
1 Figure from 538 Publications
Bruker Optics
BOPT HYPERION 1000 / HYPERION 2000 / HYPERION 3000
2
1 Figure from 202 Publications
Showing 19 of 19 products
  • <<
  • >>
  • Bruker Optics
  • Edinburgh Instruments Ltd
  • JASCO
  • Shimadzu
  • Thermo Fisher Scientific
  • WITec GmbH
  • Zolix Instruments Co., Ltd.
Get the Latest Updates, Technology News and Trends, New Products, Promotions, Buying Tips, and More!

Note: Labcompare disclaims any information on this site.