| Description | CytoFLEX SRT Benchtop Cell Sorter Overview CytoFLEX SRT Cell Sorter is a benchtop sorter. It is capable of meeting requirements for a wide range of sorting needs. And like the CytoFLEX Platform, it includes innovative technologies that simplify the setup and operation, empowering investigators to CytoFLEX SRT Benchtop Cell Sorter Overview CytoFLEX SRT Cell Sorter is a benchtop sorter. It is capable of meeting requirements for a wide range of sorting needs. And like the CytoFLEX Platform, it includes innovative technologies that simplify the setup and operation, empowering investigators to focus on the research questions. The Violet-Blue-Yellow Green-Red (V-B-Y-R) Series has 15 fluorescent detectors when fully activated. It can be purchased with as few as five, with an option to activate additional lasers and detectors with an activation key. It is capable of complex sort logic with different combinations of sort settings on each of the four streams, including the ability to catch aborts of one of the other streams. An optional Biosafety Cabinet, including aerosol evacuation or a standalone Aerosol Evacuation Unit, is available. - Capable of complex sort logic, including 4-way sorting, Mixed Mode sorting, and the ability to catch aborts and preserve precious cells
- Setup is smart and simplified, using automation to establish and maintain the sort stream
- Remote support ready using BeckmanConnect for on- demand access to our technical specialists, perform many routine maintenance procedures independently
Features CytoFLEX that Sorts - Exquisite sensitivity for multicolor applications
- Parameter matched to the CytoFLEX S V-B-Y-R Series
- Intuitive software to facilitate multicolor analysis, CytExpert for CytoFLEX SRT
Accessible Sorting - From startup to sample sorting in <30 minutes
- Uses technology to increase ease of use by automating sort stream setup and maintenance throughout the sort
- Designed for reliability and supported by teams of experts
Complex Sort Logic - Up to 15 fluorescent colors to define populations
- 4-way sorting, Mixed Mode sorting
- Ability to catch aborts and preserve precious cells
Delivering Quality Cells - High recovery and post sort viability
- Accurate single-cell deposition using the Cyclone Movement System, including Index Sorting
- Sort into tubes, slides, or microplates
... Read More | The CytoFLEX Flow Cytometer, the first introduction to the CytoFLEX Platform, provides the performance you need in an easy to use system allowing you to focus on the science, not the instrumentation. Its superior sensitivity and resolution throughout all configurations give it the edge over other The CytoFLEX Flow Cytometer, the first introduction to the CytoFLEX Platform, provides the performance you need in an easy to use system allowing you to focus on the science, not the instrumentation. Its superior sensitivity and resolution throughout all configurations give it the edge over other cytometry systems four times its size. All instruments in the platform utilize CytExpert for CytoFLEX Acquisition and Analysis Software. - Violet-Blue-Red (V-B-R) Series, fully activated with 13 colors or as few as four, activate additional channels in the future
- Includes 13 band pass filters: 450/45, 525/40 (2), 585/42, 610/20 (2), 660/10 (2), 690/50, 712/25, 780/60 (3)
- For higher throughput applications an optional plate loader module is available and for use in regulated environments the software contains tools for 21 CFR Part 11 compliance
CytoFLEX Flow Cytometer Features Exquisite Sensitivity - Unique collection of innovative technologies provide exceptional detection capabilities
- Large dynamic range to resolve dim and bright populations in the same sample
- Use violet side scatter to detect nanoparticles
Platform Versatility - Purchase the number of parameters needed now
- Add more detection channels by purchasing an activation key
- Includes full complement of repositionable bandpass filters, non-standard filters also available for even more flexibility
Low Maintenance - Lasers, steering optics and flow cell are all mounted onto a vibration isolated table, maintaining optical alignment
- Low pressure fluidics system
- Preventive Maintenance can be completed by the user, no service visit required
Automation Enabled - Optional 96-well plate sample loader module
- API (Application Programming Interface) allows external software to control the instrument
- For automated sample processing and data acquisition integrate with the Biomek i-Series Instrument
... Read More | Specifically designed for the analysis of nanoparticles, the CytoFLEX nano Flow Cytometer overcomes the limitations of traditional flow cytometry, giving researchers a flexible solution that can help them advance their research.
It is a pivotal development in flow cytometry that allows users to Specifically designed for the analysis of nanoparticles, the CytoFLEX nano Flow Cytometer overcomes the limitations of traditional flow cytometry, giving researchers a flexible solution that can help them advance their research.
It is a pivotal development in flow cytometry that allows users to analyze extracellular vesicles (EVs) at least as small as 40 nm* with ease while simultaneously offering up to 6 separate fluorescent channels of detection and 5 side scatter channels, to deliver full characterization for your nanoparticle research.
Key Specifications: - Sensitivity - With an unparalleled size sensitivity from 1µm to 40nm* and 10nm resolution, the CytoFLEX nano flow cytometer enables the detection of smaller EV populations and their low-abundance cargo.
- Flexibility - Open up your research with 6 fluorescent channels and 5 side scatter channels. Gather all the necessary data with fewer constraints.
- Maximum Consistency - Maintaining contamination-free, robust instrument performance is critical when working with small size particles. Obtain reproducible results you can trust with >90% volumetric counting accuracy and <1% carryover between samples thanks to automated QC controls.
- Familiarity - Built on the same principles as the CytoFLEX platform, the CytoFLEX nano flow cytometer features a similar footprint and user-friendly software interface.
*polystyrene when triggering on violet side scatter
For Research Use Only. Not for use in diagnostic procedures.... Read More |
| Excitation Wavelength | 405 nm (90 mW), 488 nm (50 mW), 561 nm (30 mW), 638 nm (100 mW) | 488 nm (50 mW), 638 nm (50 mW), 405 nm (80 mW), 561 nm (30 mW), 355 nm (20 mW), 375 nm (60 mW), 808 nm (60 mW) | 405 nm (120 mW), 488 nm (50 mW), 561 nm (35 mW), 638 nm (100 mW) |