| Description | Product content: S665546Component50 TStorageS665546ABuffer QSL45 mLRTS665546BBuffer RIL11 mL2-8℃S665546CBuffer ML10 mLRTS665546DBuffer GW1 (concentrate)13 mLRTS665546EBuffer GW2 (concentrate)26 mLRTS665546FBuffer EBL13 mLRTS665546GRNase A240 µLRTS665546HLysis Tubes Ⅱ50 Product content: S665546Component50 TStorageS665546ABuffer QSL45 mLRTS665546BBuffer RIL11 mL2-8℃S665546CBuffer ML10 mLRTS665546DBuffer GW1 (concentrate)13 mLRTS665546EBuffer GW2 (concentrate)26 mLRTS665546FBuffer EBL13 mLRTS665546GRNase A240 µLRTS665546HLysis Tubes Ⅱ50 EARTS665546ISpin Columns DM With Collection Tubes50 EARTProduct IntroductionThis kit provides a method for extracting total DNA from soil or fecal samples, including the total DNA of cells, bacteria, parasites, and viruses in the samples. It is also suitable for extracting DNA from samples containing high concentrations of PCR reaction inhibitors. This reagent kit adopts a unique buffering system to efficiently bind DNA from the lysis solution to the adsorption column. Inhibitors of PCR and enzyme reactions, as well as residual impurities, can be effectively removed through washing steps. Finally, high-purity DNA can be obtained by washing with low salt buffer or water. The purified DNA can be directly used for downstream experiments such as second-generation sequencing (16S amplicons and metagenomes), library construction, PCR, qPCR, Southern Blot, enzyme digestion molecular markers, etc.Self prepared reagents1. Constant temperature mixer - Product number: CW25932. Anhydrous ethanol, isopropanol3. Vortex oscillator or tissue grinderPreparation and important precautions before the experiment1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to Buffer GW1 (concentrate) and Buffer GW2 (concentrate) according to the instructions on the reagent bottle label.3. Take out the buffer RIL before use and store it at 2-8 ℃ immediately after use.Operation steps1. Centrifuge the Lysis Tube briefly to allow the beads to settle at the bottom.2. a. Add 0.1-0.3 g of soil or fecal sample to Lysis Tube, and add 740-820 µ L Buffer QSL and 4 µ L RNase A, tighten the tube cover and briefly vortex to mix.b. If fecal samples are stored in non lytic fecal preservation solutions (such as CWY041S and CWY041M), add 200 to Lysis Tube µ L-600 µ L solid-liquid mixture, centrifuge at 13000 rpm for 1 minute, discard the storage solution (if the amount of solid after centrifugation is too small, it can be enriched again, but should not exceed 0.3g). Join 620 µ LBuffer QSL and 4 µ L RNase A, tighten the tube cover and briefly vortex to mix.3. Fix the Lysis Tube in an oscillating grinding device equipped with a 2 mL adapter and process it according to the optimized grinding conditions of your equipment (see appendix).4. Shake the Lysis Tube on a constant temperature mixer at 70 ℃ and 1200 rpm for 10 minutes. Subsequently, centrifuge at 13000 rpm for 2 minutes to precipitate solid particles. Transfer 540 µ Transfer the supernatant to a new 2 mL centrifuge tube.5. Add 180 µ L Buffer RIL, vortex for 5 seconds, centrifuge at 13000 rpm for 2 minutes.Attention: Remove the buffer RIL before use and store it at 2-8 ℃ immediately after use.6. Add 160 to the new centrifuge tube in sequence µ L Buffer ML, 480 µ Supernatant from step 5, 320 µ L isopropanol, vortex for 5 seconds.7. Transfer the solution from the previous step to 650 µ Centrifuge at 12000 rpm (~13400 × g) for 1 minute into the spin columns DM that have been loaded into the collection tube.8. Discard the waste liquid in the collection pipe and place the adsorption column back into the collection pipe. Repeat step 7 until all the solution has been transferred.9. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.10. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. 11. Repeat step 10.12.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).13. Place the adsorption column in a new centrifuge tube (self provided) and add 50-200 drops of suspended droplets to the middle of the adsorption column µ L Buffer EBL or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) Incubating at room temperature for 5 minutes before centrifugation can increase yield.2) Use an additional 50-100 µ Further elution with L buffer or sterilized water can increase yield.3) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 13 back onto the adsorption membrane and repeat step 13, but it may reduce the total yield.4) The elution buffer does not contain chelating agents, please store DNA at -20 ℃.5) The residual trace PCR inhibitors in the genomic DNA template may have adverse effects on the PCR reaction, which can usually be resolved by diluting the DNA by 2-10 times.Appendix: Grind the sample using one of the following methods1. Manually vortex oscillate at maximum speed on the vortex oscillator for 10 minutes.2. On a vortex oscillator equipped with a 1.5-2 mL horizontal centrifuge tube holder, oscillate at maximum speed for 10 minutes (keeping the Lysis Tube horizontal). If the sample size exceeds 12, extend by 5-10 minutes. For example, using Scientific Industries or Mobile's Vortex Genie2 vortex oscillator.3.When using Qiagen's TissueLyser II, grind at 25Hz for 10 minutes.4.When using Qiagen's PowerLyzer 24 Homogenizer, homogenize at 2000 rpm for 30 seconds, pause for 30 seconds, and then homogenize again at 2000 rpm for 30 seconds.5.When using FastPrep-24 from MP Biomedicals, the recommended speed is 6.0 and the time is 40 seconds... Read More | D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H Buffer EB 4 mL RT D665729I Buffer PS 10 mL RT D665729J Spin Columns DF 50 Pcs 2-8 ℃ D665729K Collection Tubes 50 Pcs RTProduct Introduction:The basic principle of this reagent kit is that after DNA is treated with sodium bisulfite, unmethylated cytosine can be transformed into uracil, while methylated cytosine remains unchanged. And adopting an innovative high-temperature treatment method, the transformation time is greatly shortened, the transformation efficiency is improved, and the transformation efficiency can reach over 99%. At the same time, using a silicon-based membrane purification column, DNA can be recovered and purified from the methylated solution through a simple binding washing elution step. The recovered DNA has high purity and good integrity, and can be directly used for sequencing, methylated PCR detection, chip analysis, connection and transformation, enzyme digestion, labeling, microinjection, PCR and in vitro transcription and other molecular biology experiments.Self prepared reagents: anhydrous ethanol, 75% ethanol.Preparation and important precautions before the experiment1. Product usage method:(1) 10 times packaging preparation method: CT Conversion Agent is a solid mixture that must be prepared before first use. Add 2 ml sterile water and 100 µ M-Dissolving Buffer and 300 µ Add M-Diffusion Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 10 DNA treatments. In order to achieve better results, the prepared CT Conversion Agent should be used immediately. If not used immediately, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.(2) 50 times packaging preparation method: CT Conversion Agent and M-Dissolving Buffer are solid mixtures that must be prepared before first use. Add 5 ml of sterile water to the M-Dissolving Buffer and shake to dissolve. After all the solids have dissolved, transfer all the solution from the M-Dissolving Buffer tube to the CT Conversion Agent tube and add 5.5 ml of sterile water. Add 1.5 ml of M-Dilution Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 50 DNA treatments. In order to achieve better results, the CT Conversion Agent should be used immediately after preparation. If not immediately used, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.2. Before the first use, anhydrous ethanol should be added to the M-Wash Buffer according to the instructions on the reagent bottle label.Operation stepsThe range of DNA prepared each time is 1 ng-4 µ Between g, the optimal amount is 500 ng-2 µ G.1. Take 20 µ Add DNA sample into centrifuge tube (self provided), and if the sample amount is insufficient, replenish with water up to 20 µ L.2. Add 2.2 to the DNA sample µ Mix the sample well with the M-Dilution Buffer of l.3.42 ℃ water bath for 30 minutes.4. Add 220 to the sample obtained from the previous step µ Prepare the CT Conversion Agent solution, mix well, and incubate in an 80 ℃ constant temperature water bath in a dark place for 60 minutes.5. Add 480 to the solution in the previous step µ M - Buffer PA, gently mix upside down.6. Column balance: Add 200 to the spin columns DS that have been loaded into the collection tube µ Centrifuge at 12000 rpm (~13400 × g) for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7.Add all the solution obtained from step 5 to the adsorption column (already loaded into the collection tube), let it stand at room temperature for 2 minutes, centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Attention: The maximum capacity of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.8. Add 500 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute using M-Buffer PA, discard the waste liquid from the collection tube, and place the adsorption column in the recovery tube.9. Add 650 to the adsorption column µ M-Wash Buffer (please check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.10.12000 rpm for 2 minutes, discard the waste liquid, and place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column into a new centrifuge tube (provided by oneself), and add 20 drops to the middle position of the adsorption membrane in the air µ M-Elution Buffer (pH 8.5), leave at room temperature for 2 minutes. Collect DNA solution by centrifugation at 12000 rpm for 1 minute.12. Collect 20 µ Add 2.2 to DNA µ M-Diffusion Buffer, let it stand at room temperature for 30 minutes.13. Add 500 to the solution µ After pre cooling anhydrous ethanol, invert and mix well, and place the solution at -20 ℃ to precipitate for 30 minutes (overnight precipitation is more effective).14.12000 rpm for 15 minutes and gently discard the supernatant.15. Add 75% ethanol, centrifuge at 12000 rpm for 1 minute, pour out the supernatant, wait for ethanol to evaporate at room temperature, then add 20 µ Dissolve the M-Elution buffer and store the DNA at -20 ℃. The DNA collected in this step can be used for subsequent related experiments... Read More | M666110 Component 96 T Storage M666110A Buffer WSL 40 mL RT M666110B Buffer MSL 40 mL RT M666110C Buffer CW1 (concentrate) 90 mL RT M666110D Buffer GW1 (concentrate) 40 mL RT M666110E Buffer GW2 (concentrate) 50 mL RT M666110F Buffer EB 30 mL RT M666110G Proteinase K 4×1.25 mL RT M666110H M666110 Component 96 T Storage M666110A Buffer WSL 40 mL RT M666110B Buffer MSL 40 mL RT M666110C Buffer CW1 (concentrate) 90 mL RT M666110D Buffer GW1 (concentrate) 40 mL RT M666110E Buffer GW2 (concentrate) 50 mL RT M666110F Buffer EB 30 mL RT M666110G Proteinase K 4×1.25 mL RT M666110H Magbeads V3 2×1 mL RTProduct Introduction:The reagent kit provides a simple, fast, and efficient method for extracting genomic DNA from blood samples. In the presence of high salt, DNA binds to the surface of silica coated Magheads. After rinsing, high-purity DNA is eluted in Buffer EB or deionized water. The purified DNA has good purity (A260/280 ratio between 1.7-1.9) and high integrity (>15 kb), and can be used for downstream experiments such as second-generation sequencing, quantitative PCR, and chip detection.Self provided instruments and reagents1) Constant temperature mixer2) 2/15 ml magnetic frame3) 32 channel nucleic acid extractor4) 96 channel nucleic acid extractor5) 96 DW Plate6) 8 channel Comb7) Spin tips pack8) Anhydrous ethanolPreparation and important precautions before the experiment1.Before the first use, add anhydrous ethanol to Buffer CW1, Buffer GW1, and Buffer GW2 according to the label of the reagent bottle and mark them properly.2.Magheads are strictly prohibited from freezing or centrifugation. Freezing and centrifugation may cause irreversible damage to Magheads.Operation stepsI. Manual single tube operation1. Use punching forceps to take 1 blood spot with a diameter of 6 mm or 4 blood spots with a diameter of 3 mm (depending on the actual situation) from the blood spot and place them in a 2.0 mL centrifuge tube.2. Add 40 to the centrifuge tube µ L Protein K and 300 µ L Buffer WSL, then place the centrifuge tube on a constant temperature mixer at 75 ℃ and 1200 rpm, shake and crack for 45 minutes to form Lysate. Remove the centrifuge tube from the constant temperature mixer, centrifuge briefly, and take the supernatant.Attention: If there is no constant temperature mixer, vortex the centrifuge tube for 10 seconds and incubate it in a 75 ℃ water bath for 30 minutes. During this period, vortex every 10 minutes for 10 seconds.3. Suck the supernatant into a new 2.0 mL centrifuge tube and add 300 µ L Buffer MSL, 300 µ L isopropanol and 20 µ L Magheads V3. Afterwards, place the centrifuge tube on a constant temperature mixer at 25 ℃ and 1600 rpm, shake and crack for 15 minutes, or invert the centrifuge tube and mix continuously for 15 minutes.4. Place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, discard the solution thoroughly (keep the centrifuge tube fixed on the magnetic stand).5. Remove the centrifuge tube from the magnetic frame and add 900 µ L Buffer CW1 (please check if anhydrous ethanol has been added before use), vortex point shake for 1 minute or vortex shake for 5 seconds, and then place it on a constant temperature mixer at 25 ℃ and 1600 rpm to shake and mix for 2 minutes (ensure that Magheads are in a mixed state during the shaking process). Afterwards, place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, gently invert the magnetic stand and wash the impurities on the centrifuge tube cover to completely discard the solution (keep the centrifuge tube fixed on the magnetic stand).6. Remove the centrifuge tube from the magnetic frame and add 500 µ L Buffer GW1 (please check if anhydrous ethanol has been added before use), vortex point shake for 1 minute or vortex shake for 5 seconds, and then place it on a constant temperature mixer at 25 ℃ and 1600 rpm to shake and mix for 2 minutes (ensure that Magheads are in a mixed state during the shaking process). Afterwards, place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, gently invert the magnetic stand and wash the impurities on the centrifuge tube cover to completely discard the solution (keep the centrifuge tube fixed on the magnetic stand).7. Remove the centrifuge tube from the magnetic frame and add 900 µ L Buffer GW2 (please check if anhydrous ethanol has been added before use), vortex point shake for 1 minute or vortex shake for 5 seconds, then place it on a constant temperature mixer at 25 ℃ and 1600 rpm, shake and mix for 2 minutes (ensure that Magheads are in a mixed state during the shaking process). Afterwards, place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, gently invert the magnetic stand and wash the impurities on the centrifuge tube cover to completely discard the solution (keep the centrifuge tube fixed on the magnetic stand).8. Remove the centrifuge tube from the magnetic frame and add 300 µ After shaking with 75% ethanol for 1 minute or 5 seconds, place the mixture on a constant temperature mixer at 25 ℃ and 1600 rpm for 2 minutes (ensure that the Magheads are in a mixed state during the shaking process). Afterwards, place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, gently invert the magnetic stand and wash the impurities on the centrifuge tube cover to completely discard the solution (keep the centrifuge tube fixed on the magnetic stand).9. Keep the centrifuge tube fixed on the magnetic frame, use a pipette to further remove the solution from the bottom and cover of the centrifuge tube, and then leave it at room temperature for 5-10 minutes to allow the ethanol to evaporate completely.10. Remove the centrifuge tube from the magnetic frame and add 50-200 µ L Buffer EB. Vortex oscillation causes the magnetic beads to completely suspend in the eluent and then place them on a constant temperature mixer at 56 ℃ and 1600 rpm for 10 minutes of shaking and elution, or incubate the centrifuge tube in a 56 ℃ water bath for 10 minutes, with vortex oscillation every 3 minutes for 10 seconds.11. Place the centrifuge tube on a magnetic stand and let it stand for 2 minutes. After Magheads are completely adsorbed on the side wall of the centrifuge tube, transfer the eluent to a new centrifuge tube using a pipette and store at -20 ℃ for later use.II. Matching with CWE21001. Use punching forceps to take 1 blood spot with a diameter of 6 mm or 4 blood spots with a diameter of 3 mm (depending on the actual situation) from the blood spot and place them in a 2.0 mL centrifuge tube.2. Add 40 to the centrifuge tube µ L Protein K and 300 µ L Buffer WSL, then place the centrifuge tube on a constant temperature mixer at 75 ℃ and 1200 rpm, shake and crack for 45 minutes to form Lysate.3. Add the corresponding reagents to the 96DW deep well plate according to the table below. Position Reagent 1&7 Colume Lysate: All Buffer MSL: 300 µL isopropanol:300 µL Magbeads V3: 20 µL 2&8 Colume Buffer CW1: 900 µL 3&9 Colume Buffer GW1: 500 µL 4& 10 Colume Buffer GW2: 900 µL 5& 11 Colume 75%ethanol: 300 µL 6& 12 Colume Buffer EB: 70 µL4.Place the deep well plate and magnetic sleeve that have been added to the reagent at the corresponding positions of CWE2100/CWE3200, run the blood slide extraction program, and after about 40 minutes, the program ends. Remove the deep well plate and magnetic sleeve.5.Transfer the elution products from columns 6 and 12 of the deep well plate to a 1.5 mL centrifuge tube for low-temperature storage.III. Matching with CWE9601. Use punching forceps to take 1 blood spot with a diameter of 6 mm or 4 blood spots with a diameter of 3 mm (depending on the actual situation) from the blood spot and place them in a 2.0 mL centrifuge tube.2. Add 40 to the centrifuge tube µ L Protein K and 300 µ L Buffer WSL, then place the centrifuge tube on a constant temperature mixer at 75 ℃ and 1200 rpm, shake and crack for 45 minutes to form Lysate.3. Add the corresponding reagents to the 96DW deep well plate according to the table below Position Reagent Plate 1 Lysate: All Buffer MSL: 300 µL isopropanol :300 µL Magbeads V3: 20 µL Plate 2 Buffer CW1: 900 µL Plate 3 Buffer GW1: 500 µL Plate 4 Buffer GW2: 900 µL Plate 5 75% ethanol : 300 µL Plate 6 Buffer EB: 70 µL4. Place the deep well plate and magnetic sleeve that have been added to the reagent at the corresponding positions on CWE960, run the blood slide extraction program, and after about 40 minutes, the program ends. Remove the deep well plate and magnetic sleeve.5. Transfer the elution products from Plate 6 to a 1.5 mL centrifuge tube for low-temperature storage... Read More | R669988 Component 50T Storage R669988A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. R669988B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. R669988C Buffer RL 35 mL RT R669988D Buffer RLC 35 mL RT R669988E Buffer RW1 40 mL RT R669988F Buffer RW2 (concentrate) 11 mL R669988 Component 50T Storage R669988A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. R669988B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. R669988C Buffer RL 35 mL RT R669988D Buffer RLC 35 mL RT R669988E Buffer RW1 40 mL RT R669988F Buffer RW2 (concentrate) 11 mL RT R669988G RNase-Free Water 10 mL RT R669988H Spin Columns FL with Collection Tubes 50 sets RT R669988I Spin Columns RM with Collection Tubes 50 sets RT R669988J RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTProductsThis kit is used for the extraction and purification of high-quality total RNA from a variety of plants, and is also suitable for the extraction of fungal mycelial RNA. The unique separation column is used for homogenization and filtration of high viscosity plant or fungal lysates, while the silicon matrix membrane is used to adsorb the RNA for purification, so that various contaminants, such as polysaccharides, are effectively removed by washing, and the eluted RNA can be directly used in various downstream experiments. The molecular weight of RNA extracted by this kit is more than 200 bases, with high purity and almost no DNA residue. For RNA experiments that are very sensitive to trace DNA, the residual DNA can be removed by digestion on a column using RNase-free DNase. The extracted RNA can be used in Northern Blot, Dot Blot, RT-PCR and in vitro translation experiments.Self-contained reagents: β-mercaptoethanol, anhydrous ethanol (freshly opened or for RNA extraction).Pre-experiment Preparation and Important Notes1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.2) RNase-free water should be used to prepare the solution.(3) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.2. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.(2) Glassware should be dry-roasted at 180°C for 4 hours before use, and plasticware can be soaked in 0.5M NaOH for 10 minutes, rinsed thoroughly with water and autoclaved.3) RNase-free water should be used to prepare the solution.(4) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.3. Avoid repeated freezing and thawing of the extracted samples, otherwise it will affect the amount and quality of RNA extraction.4. Please add β-mercaptoethanol to Buffer RL before use, add 10µl of β-mercaptoethanol to 1ml of Buffer RL, it can be stored for 1 month at room temperature. Buffer RL with β-mercaptoethanol can be stored at room temperature for 1 month. β-mercaptoethanol is not required for use of Buffer RLC.5. Anhydrous ethanol should be added to Buffer RW2 before first use according to the instructions on the reagent bottle label.6. If precipitation occurs in Buffer RL and Buffer RLC, heat to dissolve and leave at room temperature.7. All centrifugation steps are carried out at room temperature and all steps are performed quickly. Procedure1. 50-100 mg of plant tissue is quickly ground to a powder in liquid nitrogen and added to 600 µl of Buffer RL (check for addition of β-mercaptoethanol before use) or Buffer RLC. vortexing and oscillating to allow for adequate lysis.Note: 1) The main component of Buffer RL is guanidine isothiocyanate, which is suitable for lysis of most plant tissues. However, in some plant tissues (e.g. endosperm of corn), due to the special secondary metabolites, guanidine isothiocyanate causes precipitation of the sample, resulting in poor RNA extraction, in this case, Buffer RLC can be added instead of Buffer RL.2) Incubation at 56°C for 1-3 minutes helps tissue lysis, but do not incubate at high temperatures for plants with high starch content.2. Transfer all the liquid obtained in step 1 to an adsorption column (Spin Columns FL) that has been loaded into a collection tube, centrifuge at 12,000 rpm (~13,400 x g) for 2 minutes, and transfer the supernatant from the collection tube to a new centrifuge tube (supplied).Note: 1) The tip of the tip of the gun can be cut off when aspirating liquids to facilitate sampling.2) Spin Columns FL removes most of the debris, but a small portion will still flow out and a precipitate will form in the collection tube after centrifugation, so be careful to avoid aspirating the precipitate when proceeding to the next step.3. Add 0.5 times the volume of anhydrous ethanol to the clean lysate obtained in step 2 and mix rapidly.Note: Precipitation may occur upon addition of ethanol, but does not affect subsequent tests.4. Transfer the solution obtained in the previous step to the Spin Columns RM in the collection tube. If it is not possible to add all of the solution to the column at one time, centrifuge the column at 12,000 rpm for 15 seconds in two batches, discard the waste solution and put the column back into the collection tube.5. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, discard the waste liquid and put the adsorbent column back into the collection tube.6. Preparation of DNase I mixture: Take 52µl of RNase-Free Water, add 8µl of 10×Reaction Buffer and 20µl of DNase I (1U/µl) to it, mix well, and make a final volume of 80µl of reaction solution.7. Add 80µl of DNase I mixture directly to the adsorption column and incubate at 20-30°C for 15 minutes.8. Add 350 µl of Buffer RW1 to the adsorption column, centrifuge at 12,000 rpm for 1 minute, discard the waste liquid and put the column back into the collection tube.9. Add 500 µl of Buffer RW2 to the column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 15 seconds, and discard the waste solution.10. Repeat step 9.11. Place the adsorbent column back into the collection tube, centrifuge at 12,000 rpm for 1 minute, and allow the column to come to room temperature for a few minutes to thoroughly dry out the anhydrous ethanol in the adsorbent column.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (zymography, PCR, etc.).12. Load the adsorption column into a new centrifuge tube, add 30-50 µl of RNase-Free Water to the middle of the adsorbent membrane, leave it at room temperature for 1 minute, centrifuge at 12,000 rpm for 1 minute, and store the resulting RNA solution at -70°C to prevent degradation.Note: 1) The volume of RNase-Free Water should not be less than 30 µl, too small volume affects the recovery rate.2) If you want to increase the RNA yield, repeat step 12 with 30-50 µl of fresh RNase-Free Water.3) If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 12 repeated... Read More | Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Collection Tubes50 sets 200 setsRTS666146HCentrifuge Tubes (1.5 mL)50 EA200 EARTProductsThis kit provides a simple and rapid method for the isolation and purification of total DNA from buccal swab samples. The kit adopts a silica matrix membrane that can specifically bind DNA and a unique buffer system to adsorb DNA efficiently and specifically, and 0.5-3.5 µg of genomic DNA can be obtained from each swab, and the extracted DNA fragments are large, pure and of stable and reliable quality. It is suitable for enzyme digestion, PCR, library construction, Southern hybridization and other experiments.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.2. If precipitation is found in Buffer GL before use, dissolve Buffer GL in a 56°C water bath.3. All centrifugation steps can be performed at room temperature.4. Sampling: Use a buccal swab to wipe the inside of the mouth 6 times, dry for 2 hours and store. To ensure that the sample is not contaminated by food or drink, do not eat or drink for 30 minutes before sampling.Procedure1. The swab of the buccal swab was cut from the rod with scissors and placed in a 2mL centrifuge tube (supplied) and 400µL Buffer GR was added.Note: For genomic DNA without RNA contamination, add 4 µL of RNase A solution at a concentration of 100 mg/ml and shake to mix.2. Add 20 µL of Proteinase K and 400 µL of Buffer GL, immediately vortex and shake for 15 seconds and mix thoroughly.Note: Mix well immediately after adding Buffer GL; do not add Proteinase K directly to Buffer GL for use.3.56°C for 10 minutes and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.4. Add 400 µL of anhydrous ethanol, vortex and shake to mix thoroughly, and centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube.Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.5. Add the solution and precipitate obtained in the previous step to the Spin Columns DS in two batches of up to 700 µL at a time into the collection tube. centrifuge the column at 12,000 rpm (∼13,400 × g) for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.6. Add 500 µL of Buffer GW1 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.7. Add 500 µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge the column at 12,000 rpm for 3 minutes, pour off the waste liquid in the collection tube, and put the column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 1 minute and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new 1.5 mL centrifuge tube, add 50 µL of Buffer GE or sterilized water to the middle of the adsorption column overhanging the column, let stand at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store at -20℃.Attention:(1) If the downstream experiment is sensitive to pH or EDTA, it can be eluted with sterilized water. The pH value of the eluent has a great influence on the elution efficiency. If the eluent is made of water, the pH value should be 7.0-8.5 (the pH value of water can be adjusted to this range by using NaOH), and the elution efficiency is not high when the pH value is lower than 7.0.2) For long-term storage, it is recommended to elute with Buffer GE and store at -20°C... Read More |