| Description | Inquire | Product IntroductionBCIP (5-Bromo-4-chloro-3-indolyl phosphate) 5-bromo-4-chloro-3-indolyl-phosphate + NBT (tetrazolium nitro blue) is the best substrate for alkaline phosphatase (AP) One of the combination. Under the catalysis of alkaline phosphatase, BCIP will be hydrolyzed to produce a highly Product IntroductionBCIP (5-Bromo-4-chloro-3-indolyl phosphate) 5-bromo-4-chloro-3-indolyl-phosphate + NBT (tetrazolium nitro blue) is the best substrate for alkaline phosphatase (AP) One of the combination. Under the catalysis of alkaline phosphatase, BCIP will be hydrolyzed to produce a highly reactive product, which reacts with NBT to form an insoluble dark blue to blue-violet compound. This kit can be used for the enzymatic color development of IHC and Western Blot experiments of the AP system. Under AP catalysis, a dark blue precipitate is produced where AP conjugates are combined on tissue sections or blotting membranes. The location and expression of the target protein can be determined based on the color reaction.Product Components40×BCIP: 1 ml40×NBT: 1 mlBCIP/NBT Buffer: 40 mlPrecautions1. The working fluid should be prepared for immediate use, and the prepared working fluid will be effective within 1 hour.2. The amount of working fluid must be sufficient to ensure complete coverage of the tissue sheet or blotting membrane. To3. In order to obtain the best experimental results, be sure to optimize the experimental conditions.4. NBT is poisonous, please take necessary protective measures when using it.5. This product is only used for scientific research, not for human experiments or human treatment.Instructions1. BCIP/NBT color developing working solution preparation:According to the required amount, mix 40×BCIP, 40×NBT and BCIP/NBT Buffer in a volume ratio of 1:1:38 to form the BCIP/NBT color developing working solution.2. Color rendering:1) Blotting membrane color development: Drop the prepared working solution on the blotting membrane (or pour the blotting membrane into the BCIP/NBT color developing working solution), and incubate for 3-10 minutes at room temperature and dark. After the color development is completed, the film is immersed in water to terminate the reaction.2) Color development of tissue sections or cell slides: Drop an appropriate amount of BCIP/NBT color developing working solution on the tissue sections or cell slides that need color development, and incubate at room temperature for 3-10 minutes in the dark. Observe under the microscope to control the color development time. When the best color development effect is reached, rinse with tap water to stop the color development. After color development, the slices are counter-stained, dehydrated and transparent, and can be stored for a long time after mounting... Read More | This reagent kit is for research purposes only. Purpose of use: This reagent kit is used to determine the content of lactose in serum, plasma, and related liquid samples.Experimental principle:This kit applies enzyme-linked immunosorbent assay to determine the level of lactose in the sample. This reagent kit is for research purposes only. Purpose of use: This reagent kit is used to determine the content of lactose in serum, plasma, and related liquid samples.Experimental principle:This kit applies enzyme-linked immunosorbent assay to determine the level of lactose in the sample. Purified lactose antibodies were coated on a microplate to produce solid-phase antibodies. Lactose was added to the microplate of the coated monoclonal antibody, along with HRP labeled lactose antigens, to compete for binding. After thorough washing, the substrate TMB was added for colorimetry. The depth of sample color is negatively correlated with the content of lactose in the sample. Measure the absorbance (OD value) at a wavelength of 450nm using an enzyme-linked immunosorbent assay (ELISA) reader, and calculate the content of lactose in the sample through a standard curve.Kit composition:130times concentrated washing solution20ml×1 bottle8.1Standard S1(80µg/L)0.5ml×1bottle2Enzyme-linked immunosorbent assay6ml×1 bottle8.2Standard S2(40µg/L)0.5ml×1bottle3Enzyme labeling coated plate96 holes x 1 pieces8.3Standard S3(20µg/L)0.5ml×1bottle4Color reagent A solution6ml×1 bottle8.4Standard S4(10µg/L)0.5ml×1bottle5Color developer B solution6ml×1 bottle8.5Standard S5(5µg/L)0.5ml×1bottle6Stop solution6ml×1 bottle9Instructions1 copy7Sample Diluent6ml×1 bottle10Microplate Sealers2 sheetsSpecimen requirements:1. Specimen processing:(1) After collecting the water sample, it is repeatedly freeze-thawed three times at -20 ℃, and then filtered through glass fiber for future reference(2) The tissue samples should be extracted using butanol: methanol: water (5:25:70 V: V: V), or extracted according to relevant literature. The experiment should be conducted as soon as possible after extraction. If the experiment cannot be conducted immediately, the specimen can be stored at -20 ℃ for future reference2. Samples containing NaN3 cannot be detected as NaN3 inhibits the activity of horseradish peroxidase (HRP).Operation steps:1. Sample addition: Set up standard wells, blank wells (blank control wells do not include samples and enzyme-linked immunosorbent assay reagents, the other steps are the same), and sample wells to be tested. Add 50 microliters to the standard well on the enzyme-linked immunosorbent assay (ELISA) plate, and first add 40 diluents to the sample well to be tested µ l. Then add 10 more samples to be tested µ L (The final dilution of the sample is 5 times). Add the sample to the bottom of the enzyme-linked immunosorbent assay (ELISA) plate well, avoiding touching the well wall as much as possible. Gently shake and mix well.2. Enzyme addition: Add 50 enzyme labeled reagents to each well µ l. Excluding blank holes.3. Warm incubation: Seal the plate with a sealing film and incubate at 37 ℃ for 60 minutes.4. Solution preparation: Dilute 30 times the concentrated washing solution with distilled water and set aside for later use5. Washing: Carefully remove the sealing film, discard the liquid, shake dry, fill each well with washing solution, let it stand for 30 seconds, then discard. Repeat this process 5 times and pat dry.6. Color development: Add color development agent A50 to each well first µ l. Add color developer B50 again µ l. Gently shake and mix well, and develop color at 37 ℃ in the dark for 15 minutes7. Termination: Add 50% termination fluid to each hole µ l. Terminate the reaction (at this point, the blue color immediately turns yellow).8. Measurement: Zero the blank hole and sequentially measure the absorbance (OD value) of each hole at a wavelength of 450nm. The measurement should be conducted within 15 minutes after adding the termination solution.Calculation:Draw a standard curve on a coordinate paper with the concentration of the standard substance as the x-axis and the OD value as the y-axis. Based on the OD value of the sample, determine the corresponding concentration from the standard curve; Multiply it by the dilution factor; Alternatively, a linear regression equation can be used to calculate the standard curve using the concentration and OD value of the standard substance. The OD value of the sample can be substituted into the equation to calculate the sample concentration, which is then multiplied by the dilution factor to obtain the actual concentration of the sample.Notes:1. The kit should be balanced at room temperature for 15-30 minutes before use when taken out from the cold storage environment. If the enzyme coated plate is not used up after opening, the Flat noodles should be stored in a sealed bag.2. Concentrated detergent may precipitate crystals. When diluted, it can be heated in a water bath to aid in dissolution. Washing does not affect the results.3. A sampler should be used for each step of sample addition, and its accuracy should be regularly calibrated to avoid experimental errors. It is best to control the sample addition time within 5 minutes. If there are a large number of specimens, it is recommended to use a firing gun for sample addition.4. Please make a standard curve at the same time as each measurement, preferably with a re hole. If the content of the substance to be tested in the sample is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute the sample diluent by a certain multiple (n times) before measurement. When calculating, please multiply the total dilution multiple (x n x 5).5. The sealing film is only for one-time use to avoid cross contamination.6. Please store the substrate in dark.7. Strictly follow the instructions and determine the test results based on the reading of the enzyme-linked immunosorbent assay (ELISA) reader8. All samples, washing liquids, and various waste should be treated as infectious substances.9. The components of this reagent with different batch numbers shall not be mixed.Detection range:two µ G/L-90 µ G/L... Read More | Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw cycle.N665730DPPM48 µL192 µL-20℃. Avoid freeze/thaw cycle.* This kit is suitable for human genomic DNA library construction with a starting template DNA input of 50 ng. We also have transposase library construction kits for human genomic DNA starting at 5 ng and 1 ng, so it is recommended to use different kits for different starting amounts of DNA in order to obtain higher quality libraries. Products IntroductionThis kit is developed for Illumina's high-throughput sequencing platform and provides the enzyme premix system and reaction buffer for genomic DNA library construction, including all components except PCR primers. Compared with the traditional library construction kits, this kit adopts the new transposase method for library construction, which can complete DNA fragmentation, end repair and junction reaction in one simple enzymatic reaction, significantly reducing the amount of template, reducing the number of experimental steps, and shortening the time of library construction; it adopts the high-fidelity DNA polymerase for library enrichment, and the preference-free PCR amplification can expand the coverage area of the sequence, which can be used for efficient and effective sequencing. The use of high-fidelity DNA polymerase for library enrichment and preference-free PCR amplification broadens the coverage area of the sequence and enables efficient preparation of DNA libraries for Illumina's second-generation sequencing platform. The kit is suitable for DNA libraries with a starting template of 50 ng, and all reagents in the kit have been subjected to strict quality control and functional validation to maximize the stability and reproducibility of library construction. Product Features ● DNA fragmentation and junction ligation in one step.● Ultra-fidelity amplification minimizes amplification-preferred steps.Provide your own instruments, kits and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use DNA purification and recovery kit by magnetic bead method.3. Library PCR primer kits: transposase method for second-generation sequencing multi-sample primer kits are recommended. 4. Anhydrous ethanol, deionized water (pH between 7.0 and 8.0).5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes. Tips: It is recommended to use high quality filter tips to prevent contamination of kits and library samples. Pre-experiment Preparation and Important Notes1. Avoid repeated freezing and thawing of reagents.2. PCR products are easily contaminated due to improper operation, resulting in inaccurate results. It is recommended to isolate the PCR reaction system preparation area from the PCR product purification area, and to use special pipettes to clean the experimental areas at regular intervals.3. Bead purification: the beads should be equilibrated to room temperature before use, all operations on the beads should be carried out at room temperature, 80% ethanol should be dispensed freshly, the beads should be rinsed and dried until the surface is free of liquid reflections and has a frosted appearance, insufficient drying of the beads will cause ethanol residue that will affect the subsequent experiments, and over-drying of the beads will affect the efficiency of DNA recovery.4. The kit is suitable for human genomic DNA library construction, if the DNA sample is a PCR product, it should be ensured that its length>.500 bp, since transposases do not work on DNA ends, it is recommended to extend the PCR product by 50-100 bp at each end of the PCR product to avoid low coverage of the ends for sequencing.Sample PreparationDNA purity requirements: A260/A280 = 1.8-2.0. Sample DNA: dissolve in ultrapure water. DNA Quantification: Too much or too little DNA will affect the quality of the library. It is recommended to use Nano to test the purity of the genomic DNA and then use Qubit to test the concentration of the genome (do not use any absorbance-based assay for template quantification).Schematic diagram of DNA banking processprocedureDNA fragmentation, junction reaction1. Add the following reagents to a 200 µl PCR tube: 2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:DNA should be purified immediately after the fragmentation reaction has been performed and the transposase is still in a high state of activity.to prevent smaller library fragments due to DNA over-fragmentation. Purification of fragmentation productsWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Add 50 µl of magnetic beads equilibrated to room temperature to the fragmentation product, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, then add 23 µlddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer 21 µl of supernatant to a new 200 µl PCR tube.PCR amplification Add the following reagents to the 200 µl PCR tube: Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:Selective recovery of library DNA fragmentsIt is recommended to use CombiVision Magnetic Beads DNA Purification and Recovery Kit for selective recovery of DNA fragments. When different sizes of DNA fragments are required, the amount of magnetic beads to be used is different, please refer to the attached table for the specific amount of magnetic beads to be used (if other brands of magnetic beads are used, you need to find out the optimal amount of magnetic beads to be used on your own).Note: Amplification products can also be fragment length sorted and purified using the Gum Recovery Kit. If there is no special requirement for library length distribution, the amplification products can also be purified without selective recovery of DNA fragments as described on page 6 of the manual.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Transfer the PCR product to a 1.5 ml centrifuge tube, rehydrate to 100 µl and add several volumes of magnetic beads equilibrated to room temperature, vortex for 5 seconds and let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, and carefully aspirate the supernatant and transfer it to a new 1.5 ml centrifuge tube.Note: Do not discard the top clear.4. Add several volumes of magnetic beads to the supernatant, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.5. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA.Note: Do not discard the beads.6. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.7. Repeat step 6 once.8. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 20 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.9. Remove the centrifuge tube from the magnetic rack, vortex and oscillate to completely resuspend the beads, and let stand at room temperature for 5 minutes. Leave brieflycentrifuge, place the tube on a magnetic rack until the solution is clear, and transfer the supernatant solution to a new centrifuge tube. Table: Suggested amount of magnetic beads for different segment selection recoveryLibrary DNA fragment purificationWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. 50 µl of magnetic beads equilibrated to room temperature were added to the PCR product, vortexed and shaken for 5 seconds, and then left to stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 25 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube.Library quality controlDetermination of library concentrationIn order to obtain high-quality sequencing results, accurate quantification of DNA libraries is required, and the first recommendation is to use Real-timePCR methods are used for absolute quantification of DNA libraries. Additionally, fluorescent dye methods such as the Qubit method or the fluorescent dye picogreen method can be used; do not use quantification methods based on absorbance measurements here. The following approximate formula can be used to convert the molar concentration of the DNA library. Average total length of librariesApproximate conversion formula Library fragment distributionThe prepared DNA libraries can be detected by agarose gel electrophoresis or Agilent 2100 Bioanalyzer.Range of segment length distributions... Read More | DescriptionGreen LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatableDescriptionGreen LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatable milliamp selection for photon intensity (sold seperately)527 nm wavelength0-30 mA variable LED outputNon-magnetic LED baseChemically resistant LED coverPTFE coated cablingPhoto Kitalysis Starter Kitrequired for operation (sold separately). Best when used withKitAlysis Benchtop Inertion Box(sold separately)... Read More |