| Description | Product introduction:Griess reagent can be used for spectrophotometric detection of nitrite. The reagent contains two chemicals, sulfonic acid and n- (1-naphthyl) ethylenediamine. Under acidic conditions, sulfamic acid is converted into diazonium salt by nitrite, which can form a highly Product introduction:Griess reagent can be used for spectrophotometric detection of nitrite. The reagent contains two chemicals, sulfonic acid and n- (1-naphthyl) ethylenediamine. Under acidic conditions, sulfamic acid is converted into diazonium salt by nitrite, which can form a highly colored azo dye with n- (1-naphthyl) ethylenediamine. This dye can be detected at 548 nm: because no is extremely unstable, it is oxidized to form nitrite and nitrate. Griess indirectly reflects the content of no by detecting the content of nitrite.Matters needing attention:1. before using Griess reagent, return it to room temperature and check the solution for precipitation. If Griess reagent I contains sediment when taken out, it can be placed in a 37 ℃ water bath until the sediment dissolves. 2. this product is potentially harmful. Avoid prolonged or repeated exposure. Avoid entering eyes, skin or clothing. Please wear lab clothes and disposable gloves for operation.Scope of application:No detectionComponent:Instruction:1.Griess Reagent I and II were taken out to restore the room temperature.2.Standard dilution : The standard NaNO2 ( 1-100 µM ) was diluted with the solution used for the sample to be tested. The standard was diluted to 1 µM, 10 µM, 20 µM, 40 µM, 80 µM and 100 µM, and 100 µL standard was added to each well. If the sample concentration is too low, the range of the standard curve can be appropriately reduced ( 1 µM, 2 µM, 3 µM, 4 µM, 6 µM, 8 µM, 10 µM ).3.Sample detection :( 1 ) According to the total volume of 200 µL / hole, 100 µL / hole sample was added to the 96-well plate ; if the sample is the supernatant of the culture medium, it can be sampled directly, and if there is sediment, the supernatant should be taken after centrifugation. If the sample is a cell or tissue, it can be quickly lysed by freeze-thaw, and then centrifuged to obtain the supernatant. The volume of less than 100 µL can be diluted with diH2O or 0.9 % NaCl ( corresponding standards also need to be diluted with diH2O or 0.9 % NaCl ).( 2 ) According to 50 µL / hole, Griess Reagent I was added to each hole.( 3 ) According to 50 µL / hole, Griess Reagent II was added to each hole.( 4 ) The absorbance was measured at 540 nm. If there is no 540 nm filter, 520-560 nm filter can also be. If there is no microplate reader or a suitable filter, the concentration of nitric oxide in the sample can also be determined by visual colorimetry. A more precise concentration gradient is required for the standard when visual colorimetric... Read More | Product IntroductionAlamar Blue detection reagent provides a simple, rapid, reliable and safe method for cell proliferation and cytotoxicity detection, which is suitable for high-throughput detection experiments. The main component of the detection reagent is a redox indicator. In the oxidized stateProduct IntroductionAlamar Blue detection reagent provides a simple, rapid, reliable and safe method for cell proliferation and cytotoxicity detection, which is suitable for high-throughput detection experiments. The main component of the detection reagent is a redox indicator. In the oxidized state, it appears purple-blue and non-fluorescent, while in the reduced state, it turns into a reduction product with pink or red fluorescence, with an absorption peak of 530-560nm and an emission peak of 590nm.In the process of cell proliferation, the ratios of NADPH/NADP, FADH/FAD, FMNH/FMN and NADH/NAD in the cell increase and are in a reducing environment. The dye taken into the cell is reduced by these metabolic intermediates and cytochromes and then released outside the cell and dissolved in the culture medium, changing the culture medium from non-fluorescent indigo blue to fluorescent pink. Finally, use an ordinary spectrophotometer or fluorophotometer for detection, and the absorbance and fluorescence intensity are proportional to the number of active cells.Instructions1. Add 10µl of detection reagent to 100µl of cell suspension, and incubate in a cell incubator for 2-6 hours. The color of the medium changes from indigo blue to pink and you can proceed to the next step.2. It is recommended to use a fluorescence microplate reader for detection, the excitation light wavelength is between 530-560 nm, the emission light wavelength is 590 nm, and the relative fluorescence unit (RFU) is recorded.3. Draw a standard curve or cell growth curve: the ordinate (Y axis) is the relative fluorescence unit (RFU); the abscissa (X axis) is the cell number or time point or drug concentration.Precautions1. The appropriate density of cells can increase the detection sensitivity. For 96-well plates, we recommend seeding 100 microliters of cells per well. The cell concentration range is: 100-10,000/well for adherent cells, 2,000-50,000/well for suspension cells, and medium as a blank control. For 384-well plates, the cell concentration and seeding volume are both halved.2. The whole process should be aseptic operation, because microbial contaminants can also reduce the detection reagents and affect the experimental results.3. Pay attention to the concentration of inoculated cells and the incubation time after adding detection reagents. If the cell concentration is too high or the incubation time is too long, it will cause a secondary reduction reaction, resulting in colorlessness and disappearance of fluorescence.4. When incubating, avoid light.5. This product can use fluorescence or spectrophotometric detection, but the sensitivity of fluorescence is high, and the experimental error is small. Fluorescence detection is recommended... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Product Characteristics Effect Diluents, Animal-free are effective buffers free of any animal components. They can be used for the dilution of serum, plasma, blood, stool or urine samples, as well as the dilution of primary and secondary antibodies. Effect Diluents, Animal-free efficiently minimize Product Characteristics Effect Diluents, Animal-free are effective buffers free of any animal components. They can be used for the dilution of serum, plasma, blood, stool or urine samples, as well as the dilution of primary and secondary antibodies. Effect Diluents, Animal-free efficiently minimize matrix effects, cross-reactions and unspecific binding in immunoassays like ELISA, Western blotting, Immunohistochemistry, protein arrays and immuno-PCR.The Effect Diluents, Animal-free are used alternatively to the standard sample or antibody dilution buffers: In ELISA for the dilution of specimen and detection antibodies. In Western Blotting for the dilution of primary and secondary antibodies. In Protein arrays for the dilution of specimen and detection antibodies. In immuno-PCR as a washing buffer.Three versions of the diluent are offered: Low, Medium and High for optimal discrimination between specific and unspecific reaction and for minimizing strong interference effects e.g., by RF (rheumatoid factors), HAMAs (human-a-mouse Abs) or by endogenous components that bind and mask the analyte.Composition & Properties The Effect Diluents, Animal free contain no animal components and are free of phosphates.Working Procedure 1.Mix thoroughly prior to use. 2.Dilution recommendations a.Dilute antibodies according to the instruction of the antibody b.Dilution of the specimen is recommended at 1:2 or higherTips & TricksEffect Diluents must not be considered as blocking buffers. Recommended blocking buffers are: Synthetic Blocking Buffer, ELISA (cat. no. S494401), Synthetic Blocking Buffer, Blotting (cat. no. S494457) and WellChampion (cat. no. W494467) for plate blocking and stabilization (preparation of pre-coated plates). Complex sample matrices, such as serum and plasma, may contain interfering factors that affect the ability of the assay to accurately quantify the target analyte. Strong interferences are often caused by RFs and HAMAs. This matrix effect can cause high background in the negative control or false negatives in the sample measurement. To reduce this effect the samples can be diluted in the Effect Diluents, Animalfree.Handling & Storage Store solution 2-8°C or -15 to -30°C (tolerates freezing and thawing cycles)... Read More | Products Content:F666101Component500 U5000 UStorageF666101AFastStar Probe Buffer (for bisDNA)2×1.2 mL2×12 mL-20℃. Avoid freeze/thaw cycle. Protect from light.F666101BSuperFastStar DNA Polymerase (5U/µL)100 µL1 mL-20℃. Avoid freeze/thaw cycle. Protect from light.Products Content:F666101Component500 U5000 UStorageF666101AFastStar Probe Buffer (for bisDNA)2×1.2 mL2×12 mL-20℃. Avoid freeze/thaw cycle. Protect from light.F666101BSuperFastStar DNA Polymerase (5U/µL)100 µL1 mL-20℃. Avoid freeze/thaw cycle. Protect from light.Products IntroductionThis product is mainly used for PCR using bisulfite-treated DNA as template, in which SuperFastStar DNA Polymerase is a new high-efficiency hot-start enzyme modified by bis-monoclonal antibody, which is completely blocked at room temperature, thus effectively avoiding non-specific amplification caused by the non-specific binding of the primer to the template or the primer dimerization under the condition of room temperature. The optimized FastStar Probe Buffer (for bisDNA) contains PCR Buffer, dNTPs and Mg2+, etc., which is easy to use as customers only need to add templates, primers and probes.caveat1 Before use, please mix the product gently by turning it up and down after it has been completely melted and centrifuged briefly.2. Avoid repeated freezing and thawing of the product, which may degrade its performance. This product can be stored at -20℃ for a long period of time, protected from light. If frequent use is required within a short period of time, it can be stored at 2-8℃.Usage The following examples are conventional PCR reaction systems and conditions, which should be improved and optimized according to the template, primer structure and target fragment size.1.PCR reaction system Note: 1) Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.2)The concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, so please refer to the instrument manual or the specific requirements for the use of each fluorescent probe to adjust the concentration.3)Usually the amount of DNA template is 10-100 ng of genomic DNA or 1-10 ng of cDNA as a reference. Since the templates of different species contain different copy numbers of the target gene, the templates can be diluted in gradients to determine the optimal amount of template to use.2.PCR reaction conditionsNote: 1) The initial denaturation of this product at 95°C for 30s is sufficient for enzyme activation; complex templates can be extended to 3min denaturation.(2) It is recommended to use two-step PCR reaction program, if you can't get good experimental results due to the use of primers with lower Tm value, etc., you can try three-step PCR amplification, and the annealing temperature should be set in the range of 56℃-64℃ as a reference... Read More |