| Description | This reagent kit is for research purposes only. Purpose of use: This reagent kit is used to determine the content of lactose in serum, plasma, and related liquid samples.Experimental principle:This kit applies enzyme-linked immunosorbent assay to determine the level of lactose in the sample. This reagent kit is for research purposes only. Purpose of use: This reagent kit is used to determine the content of lactose in serum, plasma, and related liquid samples.Experimental principle:This kit applies enzyme-linked immunosorbent assay to determine the level of lactose in the sample. Purified lactose antibodies were coated on a microplate to produce solid-phase antibodies. Lactose was added to the microplate of the coated monoclonal antibody, along with HRP labeled lactose antigens, to compete for binding. After thorough washing, the substrate TMB was added for colorimetry. The depth of sample color is negatively correlated with the content of lactose in the sample. Measure the absorbance (OD value) at a wavelength of 450nm using an enzyme-linked immunosorbent assay (ELISA) reader, and calculate the content of lactose in the sample through a standard curve.Kit composition:130times concentrated washing solution20ml×1 bottle8.1Standard S1(80µg/L)0.5ml×1bottle2Enzyme-linked immunosorbent assay6ml×1 bottle8.2Standard S2(40µg/L)0.5ml×1bottle3Enzyme labeling coated plate96 holes x 1 pieces8.3Standard S3(20µg/L)0.5ml×1bottle4Color reagent A solution6ml×1 bottle8.4Standard S4(10µg/L)0.5ml×1bottle5Color developer B solution6ml×1 bottle8.5Standard S5(5µg/L)0.5ml×1bottle6Stop solution6ml×1 bottle9Instructions1 copy7Sample Diluent6ml×1 bottle10Microplate Sealers2 sheetsSpecimen requirements:1. Specimen processing:(1) After collecting the water sample, it is repeatedly freeze-thawed three times at -20 ℃, and then filtered through glass fiber for future reference(2) The tissue samples should be extracted using butanol: methanol: water (5:25:70 V: V: V), or extracted according to relevant literature. The experiment should be conducted as soon as possible after extraction. If the experiment cannot be conducted immediately, the specimen can be stored at -20 ℃ for future reference2. Samples containing NaN3 cannot be detected as NaN3 inhibits the activity of horseradish peroxidase (HRP).Operation steps:1. Sample addition: Set up standard wells, blank wells (blank control wells do not include samples and enzyme-linked immunosorbent assay reagents, the other steps are the same), and sample wells to be tested. Add 50 microliters to the standard well on the enzyme-linked immunosorbent assay (ELISA) plate, and first add 40 diluents to the sample well to be tested µ l. Then add 10 more samples to be tested µ L (The final dilution of the sample is 5 times). Add the sample to the bottom of the enzyme-linked immunosorbent assay (ELISA) plate well, avoiding touching the well wall as much as possible. Gently shake and mix well.2. Enzyme addition: Add 50 enzyme labeled reagents to each well µ l. Excluding blank holes.3. Warm incubation: Seal the plate with a sealing film and incubate at 37 ℃ for 60 minutes.4. Solution preparation: Dilute 30 times the concentrated washing solution with distilled water and set aside for later use5. Washing: Carefully remove the sealing film, discard the liquid, shake dry, fill each well with washing solution, let it stand for 30 seconds, then discard. Repeat this process 5 times and pat dry.6. Color development: Add color development agent A50 to each well first µ l. Add color developer B50 again µ l. Gently shake and mix well, and develop color at 37 ℃ in the dark for 15 minutes7. Termination: Add 50% termination fluid to each hole µ l. Terminate the reaction (at this point, the blue color immediately turns yellow).8. Measurement: Zero the blank hole and sequentially measure the absorbance (OD value) of each hole at a wavelength of 450nm. The measurement should be conducted within 15 minutes after adding the termination solution.Calculation:Draw a standard curve on a coordinate paper with the concentration of the standard substance as the x-axis and the OD value as the y-axis. Based on the OD value of the sample, determine the corresponding concentration from the standard curve; Multiply it by the dilution factor; Alternatively, a linear regression equation can be used to calculate the standard curve using the concentration and OD value of the standard substance. The OD value of the sample can be substituted into the equation to calculate the sample concentration, which is then multiplied by the dilution factor to obtain the actual concentration of the sample.Notes:1. The kit should be balanced at room temperature for 15-30 minutes before use when taken out from the cold storage environment. If the enzyme coated plate is not used up after opening, the Flat noodles should be stored in a sealed bag.2. Concentrated detergent may precipitate crystals. When diluted, it can be heated in a water bath to aid in dissolution. Washing does not affect the results.3. A sampler should be used for each step of sample addition, and its accuracy should be regularly calibrated to avoid experimental errors. It is best to control the sample addition time within 5 minutes. If there are a large number of specimens, it is recommended to use a firing gun for sample addition.4. Please make a standard curve at the same time as each measurement, preferably with a re hole. If the content of the substance to be tested in the sample is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute the sample diluent by a certain multiple (n times) before measurement. When calculating, please multiply the total dilution multiple (x n x 5).5. The sealing film is only for one-time use to avoid cross contamination.6. Please store the substrate in dark.7. Strictly follow the instructions and determine the test results based on the reading of the enzyme-linked immunosorbent assay (ELISA) reader8. All samples, washing liquids, and various waste should be treated as infectious substances.9. The components of this reagent with different batch numbers shall not be mixed.Detection range:two µ G/L-90 µ G/L... Read More | EndoFree Plasmid Midi Kit Cat No. Component Size(50T) Storage E665631A Buffer P1 30 mL RT E665631B Buffer P2 30 mL RT E665631C Buffer E3 30 mL RT E665631D Buffer PS 15 mL RT E665631E Buffer PW (concentrate) 10 mL RT E665631F Endo-free Buffer EB 10 mL RTEndoFree Plasmid Midi Kit Cat No. Component Size(50T) Storage E665631A Buffer P1 30 mL RT E665631B Buffer P2 30 mL RT E665631C Buffer E3 30 mL RT E665631D Buffer PS 15 mL RT E665631E Buffer PW (concentrate) 10 mL RT E665631F Endo-free Buffer EB 10 mL RT E665631G RNase A (10 mg/mL) 600 µL RT E665631H Buffer ER 8 mL RT E665631I CWBlue 300 µL RT E665631J Spin Columns DL with Collection Tubes 50 EA RT E665631K Endo-Remover FM with Collection 50 EA RTProduct Introduction:Endotoxins are a common pollutant in plasmid extraction. Due to the high sensitivity of eukaryotic cells to endotoxins, the presence of endotoxins in plasmids can greatly reduce the transfection efficiency of eukaryotic cells. This reagent kit provides a simple, fast, and efficient new method for extracting endotoxin free plasmids. The extracted plasmids can remove endotoxins to the maximum extent possible and effectively remove contamination of genomic DNA, RNA, proteins, and other substances. This reagent kit is suitable for extracting 5-15mL of bacterial solution. On the basis of alkaline lysis of cells, it efficiently and specifically binds plasmid DNA through a new silicon-based membrane. Each adsorption column can adsorb up to 100 µ The plasmid DNA of g is effectively removed using a special buffer system and endotoxin removal filter column, effectively removing impurities such as endotoxins and proteins. The plasmid obtained from this kit has high purity and stable quality, making it particularly suitable for cell transfection. It can also be used for downstream experiments such as DNA sequencing, PCR, PCR based mutations, in vitro transcription, transformed bacteria, and endonuclease digestion.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1. All components can be stably stored in a dry, room temperature (15-30 ℃) environment for 1 year, and can be stored at 2-8 ℃ for longer periods of time. Buffer P1 with RNase A added can be stably stored at 2-8 ℃ for 6 months.2. Before the first use, add all RNase A solution to Buffer P1, mix well, and store at 2-8 ℃. Before use, let it sit at room temperature for a period of time. After returning to room temperature, use.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer P2 and Buffer E3. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. Be careful not to come into direct contact with Buffer P2 and Buffer E3, and immediately cover them tightly after use.6.The amount and purity of plasmid extraction are related to factors such as bacterial culture concentration, strain type, plasmid size, and plasmid copy number.Operation steps:1. Take 5-15 mL of overnight cultured bacterial solution and add it to a centrifuge tube (self provided). Centrifuge at 13000 rpm (~16200 × g) for 1 minute to collect bacteria, and try to discard all the supernatant as much as possible.2. Add 500 to the centrifuge tube containing bacterial sediment µ L Buffer P1 (please check if RNase A has been added first), mix thoroughly with a pipette or vortex oscillator, and suspend bacterial precipitation. Attention: If the bacterial blocks are not thoroughly mixed, it will affect the cracking effect, resulting in low extraction amount and purity.3. Add 500 to the centrifuge tube µ L Buffer P2, gently invert and mix 8-10 times, allowing the bacterial cells to fully lyse. Leave at room temperature for 3-5 minutes. At this point, the solution should become clear and viscous. Attention: Mix gently and do not shake vigorously to avoid interrupting genomic DNA and mixing genomic DNA fragments in the extracted plasmid. If the solution does not become clear, it indicates that the bacterial count may be too high and the lysis may not be complete. The bacterial count should be reduced.4. Add 500 to the centrifuge tube µ L Buffer E3, immediately invert and mix 8-10 times until white flocculent precipitates appear. Let it stand at room temperature for 5 minutes. Centrifuge at 13000 rpm for 5 minutes, extract the supernatant, and add it to the filter column (Endo Remove FM) (already loaded into the collection tube). Centrifuge at 13000 rpm for 1 minute to filter, then transfer the filtrate from the collection tube to the centrifuge tube (self provided). Attention: 1) After adding Buffer E3, it should be immediately mixed to avoid local precipitation. 2) The maximum volume of the adsorption column is 750 µ L. So please filter the supernatant twice and mix it in the same self provided centrifuge tube.5. Add 450 to the filtrate µ Mix L isopropanol upside down.6. Column balance: Add 200 to the spin columns DL that have been loaded into the collection tube µ L Buffer PS, centrifuge at 13000 rpm for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Transfer the mixed solution of filtrate and isopropanol from step 5 to an equilibrium adsorption column (already loaded into a collection tube). 8.13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. Attention: The maximum volume of the adsorption column is 750 µ L. So the solution obtained in step 5 is divided multiple times and passed through the column. 9. Add 750 to the adsorption column µ L Buffer PW (please check if anhydrous ethanol has been added first), centrifuge at 13000 rpm for 1 minute, and discard the waste liquid in the collection tube.10. Place the adsorption column back into the recovery manifold and centrifuge at 13000 rpm for 1 minute.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self provided)... Read More | Store at -20°C. Please refer to protocols | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for extracting total DNA from fecal samples, including the total DNA of cells, bacteria, parasites, and viruses in the samples, as well as samples containing high concentrations of PCR reaction inhibitors. This product can process up to 300 mg of fecal samples and purify to obtain mainly 20-30 kb DNA fragments. The purification process does not require toxic solvents such as phenol or chloroform, and does not require ethanol precipitation. High purity DNA can be obtained within one hour. This reagent kit adopts a unique buffering system to efficiently bind DNA from the lysis solution to the adsorption column. At the same time, protein impurities and other organic compounds that inhibit downstream reactions in feces can flow through the membrane. Inhibitors of PCR and enzyme reactions, as well as residual impurities, can be effectively removed through two washing steps. Finally, high-purity DNA can be obtained by washing with low salt buffer or water. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, Real Time PCR, library construction, Southern Blot, and molecular labeling.Preparation and important precautions before the experiment1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to Buffer GW1 and GW2 according to the instructions on the reagent bottle label.3. Before use, please check whether there is crystallization or precipitation in Buffer SL and Buffer GL. If there is crystallization or precipitation, please dissolve Buffer SL and Buffer GL again in a 56 ℃ water bath.4. If downstream experiments are sensitive to RNA contamination, 4 can be added after adding Buffer SL µ RNase A of DNase Free (100 mg/ml) is not provided in this kit. If needed, it can be ordered separately from our company, item number: S665549Operation steps1. Take a fecal sample of 100-300 mg and place it in a centrifuge tube (provided by oneself).2. Add 1 ml of Buffer SW and vortex for 3-5 minutes to evenly disperse the sample in the solution. Centrifuge at 12000 rpm (~13400 × g) for 1 minute and discard the supernatant.3. Add 1 ml of Buffer SL and vortex for 3-5 minutes to evenly disperse the sample in the solution. Take a water bath at 65 ℃ for 20 minutes and vortex for 15 seconds every 5 minutes. Note: To remove RNA, add 4 after completing the above steps µ RNase A solution (product number: CW0601S) with a concentration of 100 mg/ml, shake well and let stand at room temperature for 5-10 minutes.4.Centrifuge at 2000 rpm for 3 minutes and transfer the supernatant to a new centrifuge tube (provided by oneself).5. Add an equal volume of Buffer GL to the supernatant, invert and mix 15-25 times, and leave on ice for 5 minutes. Centrifuge at 12000 rpm for 5 minutes. Attention: At this time, the liquid may be in a transparent or turbid state, which does not affect the experiment. 6. Add the supernatant obtained in step 5 to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. 8. Repeat step 7.9. Add 500 to the adsorption column µ Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.10.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self provided) and add 50-100 drops of suspended droplets to the middle of the adsorption column µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency will be reduced2) Incubating at room temperature for 5 minutes before centrifugation can increase yield.3) Use an additional 50-100 µ Further washing with buffer GE or sterilized water can increase yield.4) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 11 back onto the adsorption membrane and repeat step 11; It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with buffer GE or sterilized water.5) DNA stored in water can be affected by acidic hydrolysis. If long-term storage is required, it is recommended to elute with Buffer GE and store at -20 ℃.6) The residual trace PCR inhibitors in the genomic DNA template may have adverse effects on the PCR reaction, which can be solved by diluting DNA by 2-10 times... Read More |