| Description | This reagent kit is for research purposes only. Purpose of use: This reagent kit is used to determine the content of lactose in serum, plasma, and related liquid samples.Experimental principle:This kit applies enzyme-linked immunosorbent assay to determine the level of lactose in the sample. This reagent kit is for research purposes only. Purpose of use: This reagent kit is used to determine the content of lactose in serum, plasma, and related liquid samples.Experimental principle:This kit applies enzyme-linked immunosorbent assay to determine the level of lactose in the sample. Purified lactose antibodies were coated on a microplate to produce solid-phase antibodies. Lactose was added to the microplate of the coated monoclonal antibody, along with HRP labeled lactose antigens, to compete for binding. After thorough washing, the substrate TMB was added for colorimetry. The depth of sample color is negatively correlated with the content of lactose in the sample. Measure the absorbance (OD value) at a wavelength of 450nm using an enzyme-linked immunosorbent assay (ELISA) reader, and calculate the content of lactose in the sample through a standard curve.Kit composition:130times concentrated washing solution20ml×1 bottle8.1Standard S1(80µg/L)0.5ml×1bottle2Enzyme-linked immunosorbent assay6ml×1 bottle8.2Standard S2(40µg/L)0.5ml×1bottle3Enzyme labeling coated plate96 holes x 1 pieces8.3Standard S3(20µg/L)0.5ml×1bottle4Color reagent A solution6ml×1 bottle8.4Standard S4(10µg/L)0.5ml×1bottle5Color developer B solution6ml×1 bottle8.5Standard S5(5µg/L)0.5ml×1bottle6Stop solution6ml×1 bottle9Instructions1 copy7Sample Diluent6ml×1 bottle10Microplate Sealers2 sheetsSpecimen requirements:1. Specimen processing:(1) After collecting the water sample, it is repeatedly freeze-thawed three times at -20 ℃, and then filtered through glass fiber for future reference(2) The tissue samples should be extracted using butanol: methanol: water (5:25:70 V: V: V), or extracted according to relevant literature. The experiment should be conducted as soon as possible after extraction. If the experiment cannot be conducted immediately, the specimen can be stored at -20 ℃ for future reference2. Samples containing NaN3 cannot be detected as NaN3 inhibits the activity of horseradish peroxidase (HRP).Operation steps:1. Sample addition: Set up standard wells, blank wells (blank control wells do not include samples and enzyme-linked immunosorbent assay reagents, the other steps are the same), and sample wells to be tested. Add 50 microliters to the standard well on the enzyme-linked immunosorbent assay (ELISA) plate, and first add 40 diluents to the sample well to be tested µ l. Then add 10 more samples to be tested µ L (The final dilution of the sample is 5 times). Add the sample to the bottom of the enzyme-linked immunosorbent assay (ELISA) plate well, avoiding touching the well wall as much as possible. Gently shake and mix well.2. Enzyme addition: Add 50 enzyme labeled reagents to each well µ l. Excluding blank holes.3. Warm incubation: Seal the plate with a sealing film and incubate at 37 ℃ for 60 minutes.4. Solution preparation: Dilute 30 times the concentrated washing solution with distilled water and set aside for later use5. Washing: Carefully remove the sealing film, discard the liquid, shake dry, fill each well with washing solution, let it stand for 30 seconds, then discard. Repeat this process 5 times and pat dry.6. Color development: Add color development agent A50 to each well first µ l. Add color developer B50 again µ l. Gently shake and mix well, and develop color at 37 ℃ in the dark for 15 minutes7. Termination: Add 50% termination fluid to each hole µ l. Terminate the reaction (at this point, the blue color immediately turns yellow).8. Measurement: Zero the blank hole and sequentially measure the absorbance (OD value) of each hole at a wavelength of 450nm. The measurement should be conducted within 15 minutes after adding the termination solution.Calculation:Draw a standard curve on a coordinate paper with the concentration of the standard substance as the x-axis and the OD value as the y-axis. Based on the OD value of the sample, determine the corresponding concentration from the standard curve; Multiply it by the dilution factor; Alternatively, a linear regression equation can be used to calculate the standard curve using the concentration and OD value of the standard substance. The OD value of the sample can be substituted into the equation to calculate the sample concentration, which is then multiplied by the dilution factor to obtain the actual concentration of the sample.Notes:1. The kit should be balanced at room temperature for 15-30 minutes before use when taken out from the cold storage environment. If the enzyme coated plate is not used up after opening, the Flat noodles should be stored in a sealed bag.2. Concentrated detergent may precipitate crystals. When diluted, it can be heated in a water bath to aid in dissolution. Washing does not affect the results.3. A sampler should be used for each step of sample addition, and its accuracy should be regularly calibrated to avoid experimental errors. It is best to control the sample addition time within 5 minutes. If there are a large number of specimens, it is recommended to use a firing gun for sample addition.4. Please make a standard curve at the same time as each measurement, preferably with a re hole. If the content of the substance to be tested in the sample is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute the sample diluent by a certain multiple (n times) before measurement. When calculating, please multiply the total dilution multiple (x n x 5).5. The sealing film is only for one-time use to avoid cross contamination.6. Please store the substrate in dark.7. Strictly follow the instructions and determine the test results based on the reading of the enzyme-linked immunosorbent assay (ELISA) reader8. All samples, washing liquids, and various waste should be treated as infectious substances.9. The components of this reagent with different batch numbers shall not be mixed.Detection range:two µ G/L-90 µ G/L... Read More | Product IntroductionBCIP (5-Bromo-4-chloro-3-indolyl phosphate) 5-bromo-4-chloro-3-indolyl-phosphate + NBT (tetrazolium nitro blue) is the best substrate for alkaline phosphatase (AP) One of the combination. Under the catalysis of alkaline phosphatase, BCIP will be hydrolyzed to produce a highly Product IntroductionBCIP (5-Bromo-4-chloro-3-indolyl phosphate) 5-bromo-4-chloro-3-indolyl-phosphate + NBT (tetrazolium nitro blue) is the best substrate for alkaline phosphatase (AP) One of the combination. Under the catalysis of alkaline phosphatase, BCIP will be hydrolyzed to produce a highly reactive product, which reacts with NBT to form an insoluble dark blue to blue-violet compound. This kit can be used for the enzymatic color development of IHC and Western Blot experiments of the AP system. Under AP catalysis, a dark blue precipitate is produced where AP conjugates are combined on tissue sections or blotting membranes. The location and expression of the target protein can be determined based on the color reaction.Product Components40×BCIP: 1 ml40×NBT: 1 mlBCIP/NBT Buffer: 40 mlPrecautions1. The working fluid should be prepared for immediate use, and the prepared working fluid will be effective within 1 hour.2. The amount of working fluid must be sufficient to ensure complete coverage of the tissue sheet or blotting membrane. To3. In order to obtain the best experimental results, be sure to optimize the experimental conditions.4. NBT is poisonous, please take necessary protective measures when using it.5. This product is only used for scientific research, not for human experiments or human treatment.Instructions1. BCIP/NBT color developing working solution preparation:According to the required amount, mix 40×BCIP, 40×NBT and BCIP/NBT Buffer in a volume ratio of 1:1:38 to form the BCIP/NBT color developing working solution.2. Color rendering:1) Blotting membrane color development: Drop the prepared working solution on the blotting membrane (or pour the blotting membrane into the BCIP/NBT color developing working solution), and incubate for 3-10 minutes at room temperature and dark. After the color development is completed, the film is immersed in water to terminate the reaction.2) Color development of tissue sections or cell slides: Drop an appropriate amount of BCIP/NBT color developing working solution on the tissue sections or cell slides that need color development, and incubate at room temperature for 3-10 minutes in the dark. Observe under the microscope to control the color development time. When the best color development effect is reached, rinse with tap water to stop the color development. After color development, the slices are counter-stained, dehydrated and transparent, and can be stored for a long time after mounting... Read More | Calcein AM /PI Double Staining Kitis utilized for simultaneous fluorescence staining of viable and dead cells. This kit contains Calcein-AM and Propidium Iodide (PI) solutions, which stains viable and dead cells, respectively(Fig. 1). Calcein-AM, an acetoxymethyl ester of calcein, is highly Calcein AM /PI Double Staining Kitis utilized for simultaneous fluorescence staining of viable and dead cells. This kit contains Calcein-AM and Propidium Iodide (PI) solutions, which stains viable and dead cells, respectively(Fig. 1). Calcein-AM, an acetoxymethyl ester of calcein, is highly lipophilic and cell membrane permeable. Though Calcein-AM itself is not a fluorescent molecule, the calcein generated from Calcein-AM by esterase in a viable cell emits a strong green fluorescence (excitationat 490 nm, emission at515 nm). Therefore, Calcein-AM only stains viable cells. On the other hand, PI, a nuclei staining dye, cannot pass through a viable cell membrane. It reaches the nucleus by passing through disordered areas of dead cell membrane, and intercalates with the DNA double helix of the cell to emit red fluorescence (excitation: 535 nm,emmision: 617 nm). Since both calcein and PI-DNA can be excited with 490 nm, simultaneous monitoring of viable and dead cells is possible with a fluorescence microscope. With 545 nm excitation, only dead cells can be observed (Fig. 1). Since optimal staining conditions differ from cell line to cell line, we recommend that a suitable concentration of PI and Calcein-AM be individually determined. Please note that PI is suspected to be highly carcinogenic;careful handling is required.Required Equipment and Materials:Microscope with 490 nm excitation filter and 530 nm emission filter;CO2incubator;10 µl and 200 µl adjustable pipettes, PBSSolution A (Calcein-AM);Solution B (PI) Storage Condition: -20oC ;Shipping Condition: blue ice.Application:Assay Procedure1)Add 2.5 µl Solution A and 12.5 µl Solution B to 5 ml PBS to prepare assay solution.*2)Wash the cell with PBS several times to remove residual esterase activity.3)Add 100uLof assay solution to200uL105~106CELLSsolution and incubate the mixture at 37oC for 15 min.4)Detect fluorescence using a fluorescence mircoscope with 490 nm excitationfor simultaneous monitoring of viable and dead cells.With 545 nm excitation, only dead cells can be observed.*The following steps may be necessary tooptimizethe suitable concentration of each reagent:1)Prepare dead cells by 10 min incubation in 0.1% saponin or 0.1-0.5% digitonin or by 30 min incubation in 70% ethanol.2)Stain dead cells with 0.1-10 µM PI solution to find a PI concentration that stains the nucleus only, not the cytosol.3)Stain dead cells with 0.1-10 µM Calcein-AM solution to find a Calcein-AM concentration that does not stain the cytosol. Then stainviable cells with that Calcein-AM solution to check whether the viable cell can be stained... Read More | Product contentG665801Component100 TStorageG665801A2×GoldStar Probe One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801BGoldStar Probe One Step EnzymeMix100 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801C50×High ROX50 µL-20Product contentG665801Component100 TStorageG665801A2×GoldStar Probe One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801BGoldStar Probe One Step EnzymeMix100 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801C50×High ROX50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801DRNase-Free Water1.5 mL-20℃. Avoid freeze/ Thaw cycle. Product Introduction This product is a specialized kit for one-step Real-Time RT-qPCR using the probe method (TaqMan, Molecular Beacon, etc.). When using this product for Real Time RT-qPCR reaction, reverse transcription and quantitative PCR are carried out in the same reaction system, and there is no need to add reagents or open the cap of the tube during the reaction process, which avoids contamination and improves the experimental efficiency at the same time. With high detection sensitivity, strong fluorescence signal and high signal-to-noise ratio, this product is very suitable for the detection of RNA viruses and other trace RNA. The special buffer system contained in this product can maximize the effectiveness of reverse transcriptase and DNA polymerase at the same time and improve the efficiency of the reaction. A wider linear range can be obtained with this product, more accurate quantification of the target gene, good reproducibility and high confidence.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument. Instruments that do not require ROX calibration (G665836) Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others. Instruments that require High ROX calibration (G665801) ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1.Before using the reagents in this kit, please mix them gently by turning them up and down to avoid foaming as much as possible, and use them after brief centrifugation.2.This product uses RNA as the template for one-step RT-PCR experiment, RNase contamination should be avoided during operation, it is recommended to operate RNA in a special area, use special instruments and consumables, the operator with a mask and disposable gloves and often change the gloves, the experiment-related consumables should be processed with 0.1% DEPC (diethyl ether pyrocarbonate) aqueous solution for 12 hours at 37℃, and autoclaved for 30 minutes before use. The consumables should be treated with 0.1% DEPC (diethylpyrocarbonate) aqueous solution at 37℃ for 12 hours and autoclaved for 30 minutes.3.Repeated freezing and thawing of each reagent in this kit should be avoided as much as possible; repeated freezing and thawing may degrade the product performance.4.This kit must use specific primers, the choice of primers can be selected according to specific experiments, the good or bad primer design directly affects the results of RT-qPCR reaction, the design of primers need to consider the GC content, primer length, primer position, the secondary structure of the PCR product and other factors, it is recommended to use a professional primer design software for design.5.This kit is recommended to use specific probes, and it is recommended to use professional design software for designing.UsageThe following examples are conventional reaction systems and conditions, which should be improved and optimized according to the different templates, primer structures and target fragment sizes in actual operation. (Please prepare the reaction solution on ice.)1. Dissolve RNA template, primers, 2× GoldStar Probe One Step Buffer, GoldStar Probe One Step EnzymeMix and RNase-Free Water and set aside on ice.2. PCR reaction system:reagents25µl reaction systemfinal concentration2×GoldStar Probe One Step Buffer12.5µl1×Forward Primer, 10µM0.5µl0.2µM¹⁾Reverse Primer, 10µM0.5µl0.2µM¹⁾Probe, 10µM0.5µl0.2µM²⁾GoldStar Probe One Step EnzymeMix1.0µl RNA TemplateXµl10pg-100ng³⁾50 x Low ROX or High ROX (optional)⁴⁾0.5µl1×RNase-Free WaterUp to 25µlNote: 1) Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.(2) The concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of RNA template is 10pg-100ng as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be diluted in gradient to determine the optimal amount of template to use.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.3. Mix well, centrifuge briefly, and collect the solution at the bottom of the tube.4.RT-PCR reaction conditions:Note: 1) The hot start enzyme used in this product must be activated under the condition of pre-denaturation 95℃, 5-10min. 2) It is recommended to use the two-step PCR reaction program, if you can not get good experimental results due to the use of primers with lower Tm value, etc., you can try to carry out the three-step PCR amplification, and the annealing temperature should be set in the range of 56℃-64℃ as a reference... Read More | H665581 Component 100 T Storage H665581A gDNA Eraser 50 µL -20℃. Avoid freeze/thaw cycle. H665581B 10×gDNA Eraser Buffer 120 µL -20℃. Avoid freeze/thaw cycle. H665581C HiFiScript, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665581D 5×ScriptRT H665581 Component 100 T Storage H665581A gDNA Eraser 50 µL -20℃. Avoid freeze/thaw cycle. H665581B 10×gDNA Eraser Buffer 120 µL -20℃. Avoid freeze/thaw cycle. H665581C HiFiScript, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665581D 5×ScriptRT Buffer 500 µL -20℃. Avoid freeze/thaw cycle. H665581E Primer Mix 120 µL -20℃. Avoid freeze/thaw cycle. H665581F RNase-Free Water 2×1 mL -20℃. Avoid freeze/thaw cycle.Product IntroductionThis product is a kit for removing genomic DNA for reverse transcription. The kit removes genomic DNA in 2 minutes at 42°C. Since the reverse transcription reagent contains a component that inhibits gDNA Eraser, cDNA can be synthesized directly by reverse transcription of gDNA Eraser-treated samples.The kit is equipped with a new high-efficiency reverse transcription enzyme, HiFiScript, with novel mutation sites that dramatically increase the transcriptional activity of the enzyme, resulting in higher efficiency and yield of cDNA first-strand synthesis. The first strand of cDNA can be synthesized with higher efficiency and yield, and the first strand of cDNA can be synthesized from pg total RNA or mRNA. If the reverse transcription product cDNA is used for downstream fluorescence quantitative detection, the reverse transcription reaction can be completed at 42℃ in 15 minutes. This kit is suitable for the synthesis of first-strand cDNA and subsequent RT-PCR, RT-qPCR, and the construction of full-length cDNA libraries.Product Features1. Rapid genome removal: contains gDNA Eraser for genomic DNA removal, which removes genomic DNA in just 2 minutes.2. Rapid reverse transcription: 15 minutes to obtain fluorescent quantitative PCR template cDNA first strand synthesis.3. High sensitivity: cDNA first strand can be synthesized using pg-level total RNA or mRNA templates.4. Highly efficient reverse transcription: Novel mutation sites dramatically increase enzyme activity, resulting in higher yields of cDNA.matters needing attention1. During operation, RNase contamination should be avoided to prevent RNA degradation or cross-contamination in the experiment. It is recommended that operators wear masks and disposable gloves and change the gloves frequently, and use specialized instruments and consumables.2. The reverse transcription system is prepared and operated on ice to prevent degradation of RNA. Store the kit enzymes at -20ºC as soon as possible after use and try to avoid repeated freezing and thawing.3. The reaction system can be scaled up to a maximum of 1 µg of total RNA in 10 µl of reaction system.4. Primer Mix is prepared by Oligo(dT) and Random primer, and Oligo-dT Primer or Gene Specific Primer can also be used according to the experimental needs.5. If the amount of starting RNA is less than 50ng, it is recommended to add RNAase inhibitor (RNasin).6. For RNA templates with complex secondary structures, it is recommended to incubate the template RNA at 65°C for 5 minutes immediately on ice prior to the manipulation step and centrifuge briefly before proceeding to the next step.UsageThaw template RNA on ice; place kit components on ice immediately after thawing at room temperature. Each solution was mixed by vortexing and shaking before use and briefly centrifuged.I. Genomic DNA removal reactions1. Prepare the reaction system according to the following table on ice in a total volume of 10 µl. To ensure the accuracy of the reaction solution preparation, prepare the premixed system in the amount of reaction number + 2 before dispensing it into each reaction tube and finally adding the RNA sample.Note: 1) If the amount of total RNA is greater than 1µg, scale up the reaction system proportionally. If the amount of starting RNA is less than 50ng, it is recommended to add RNAase inhibitor (RNasin).2. Mix by vortex shaking and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.3. Incubate at 42°C for 2 minutes (this can be extended to 30 minutes for room temperature reactions).4.At the end of the reaction, centrifuge briefly and place on ice to cool.II. Reverse transcription reaction1. Prepare the reaction system on ice according to the following table. In order to ensure the accuracy of the reaction solution configuration, first prepare a premixed solution in the amount of number + 2, and then dispense 10 µl into each reaction tube, take 10 µl of the prepared premixed solution and add it to the reaction tube of step 1 where the de-etching of the genome has been completed.Note: 1) Oligo-dT Primer or Gene Specific Primer can be used according to the needs of the experiment, it is recommended to use 50 pmol of Oligo-dT Primer or 2 pmol of Gene Specific Primer for 20 µl reaction system.2. Mix well and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.3. cDNA synthesis reaction conditions:1) If fluorescent quantitative PCR assay is performed downstream, incubate at 42°C for 15 minutes and 85°C for 5 minutes.2) If downstream for normal PCR assay, incubate at 42°C for 30-50 minutes and 85°C for 5 minutes. Note: For templates with complex secondary structure or high GC content, the reverse transcription temperature can be increased to 50°C to enhance reverse transcription efficiency.4. At the end of the reaction, centrifuge briefly and place on ice before proceeding with subsequent PCR or fluorescence quantitative PCR, or place at -20°C if prolonged storage is required.Note: When performing Real-time PCR reactions, the amount of reverse transcription product added should not exceed 1/10 of the total volume of the PCR reaction... Read More |