| Description | Product introduction: The MA qPCR live bacteria detection kit provides an effective means for detecting bacterial activity. The kit provides a mixture of PMA dye and qPCR based on SYBR Green dye. The optimal amount of dye and the number of samples that can be treated may vary depending on theProduct introduction: The MA qPCR live bacteria detection kit provides an effective means for detecting bacterial activity. The kit provides a mixture of PMA dye and qPCR based on SYBR Green dye. The optimal amount of dye and the number of samples that can be treated may vary depending on the type of sample. PMA is a high-affinity DNA-binding dye, especially with double-stranded DNA. The dye itself has weak fluorescence, but it can emit brighter fluorescence after binding to nucleic acids. PMA is impermeable to cell membranes, so it can selectively modify the DNA of dead cells with damaged membranes. After the PMA-modified DNA is photolyzed by blue light ( ~ 464 nm ), the photoreactive azide group on the PMA is converted into a highly reactive nitrene radical, which reacts with any hydrocarbon near the DNA binding site to form a stable covalent nitrogen-carbon bond, resulting in permanent DNA modification. This modification process will make DNA insoluble and lost with cell debris during the later genomic DNA extraction process. The unbound PMA remaining in the solution reacts with water molecules under strong light irradiation to decompose into hydroxylamine compounds without cross-linking activity, so that it can no longer covalently bind to DNA. Based on this feature of PMA, PMA was combined with qPCR technology to form a new detection method, PMA-qPCR, for the screening of live bacteria. At present, the method has been verified in a variety of bacterial strains, yeast, fungi, viruses and parasites. The treatment of complex samples, such as manure or soil, may require optimization of sample dilution, dye concentration, and light treatment time. The treatment of diluted samples, such as water testing, may require filtration or concentration prior to dye treatment. Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. the components of the kit contain fluorescent dyes. Avoid light during use and storage. 3. for your safety and health, please wear experimental clothes and disposable gloves.Product parameters:Spectral characteristics :PMA: Ex = 464 nm; Ex/Em = 510/610 nm (following photolysis and reaction with DNA/RNA)Component: PMA:Ex = 464 nm; Ex/Em = 510/610 nm (following photolysis and reaction with DNA/RNA) Instruction: Precautions before use: 1.This live bacteria detection kit distinguishes dead bacteria and live bacteria according to cell membrane permeability. Many methods of killing bacteria cause damage to the cell membrane and are therefore compatible with this kit. But some methods, such as ultraviolet irradiation, may not immediately cause cell membrane rupture. Therefore, before selecting this kit, it is necessary to carry out literature search and pre-experiment to determine whether the kit is suitable for the bacterial type and killing method you choose. 2.After PMA treatment, the bacteria need to be photolyzed to covalently bind the dye to dead cell DNA. Photolysis operations can use blue or white light sources. Generally speaking, the brighter the lamp, the higher the efficiency of the photolysis step. Non-LED lamps ( such as halogen lamps ) may heat your sample and have a negative impact on the analysis. Ice is required to cool the sample during irradiation. 3.Sample can be cryopreservation after photolysis. Frozen samples before PMA treatment photolysis may damage the cell membrane and produce false negative results. If the sample needs to be frozen before detection, it is recommended to perform a pre-experiment first. 4.Part of the mechanism of PMA is to remove PMA covalently modified DNA from the sample by precipitation ; therefore, when extracting genomic DNA, it is necessary to use the same volume of genomic DNA eluent for volume normalization. The positive control can use the genomic DNA of living cells. 5.In order to verify the effectiveness of PMA in the test sample, the Ct ( dCt ) changes between- / + PMA can be compared. Experimental materials ( self-provided ):①Light source ( for the photolysis step after PMA modification of DNA ) ; ② Bacterial genomic DNA extraction kit ; ③ effective qPCR primers corresponding to the sample type Experimental procedure: 1.Suck 10 µL of E.coli bacterial solution in liquid LB medium, and culture E.coli in the bacterial incubator overnight or longer to the logarithmic growth phase ( OD600 ≈ 1.0 ) ; Note : The culture time is adjusted according to the experiment. 2.Two portions of live E.coli, 400 µL each, were placed in a clean centrifuge tube ; 3. ( Recommended ) Preparation of dead E.coli. If the dead E.coli is needed as a control, the dead E.coli can be obtained by heating the living E.coli in a water bath at 95 °C for 5 min, or at 58 °C for 3 h. the subsequent operation of the dead E. coli is the same as that of the living E. coli ; 4.Two copies of live E.coli, one without PMA treatment, and one with 25 µM PMA treatment ( the optimal PMA concentration for treating different types or different sources of bacteria needs to be consulted in the relevant literature ) ; 5.The PMA-treated samples were placed on a shaker at room temperature and incubated in the dark for 10 min to fully mix the dye with the sample ; 6.Exposure of the sample, you can use blue or white light source, irradiation time to explore their own. For example, a 60 W blue light can be used for 15 min. Note : 1 If a halogen lamp is used, we recommend that the PMA-treated sample tube be placed on an ice block 20 cm away from the light source. Ice should be placed in a transparent tray. Adjust the light source to point directly to the sample, photolysis for 5-15 min ; if the bacteria obtained from the environment are directly used for experiments, due to the complexity or turbidity of the environmental samples, the photolysis time needs to be prolonged appropriately. 7.Treated and untreated live E.coli 5000 × g, centrifuged for 10 min, remove the supernatant ; 8.Select the appropriate genomic DNA extraction kit according to the sample type, and use the same elution volume for each group of samples when elution DNA. Note : DNA extraction steps refer to the instructions of the kit used. Part of the mechanism of action of PMA is to remove PMA-bound DNA from the sample by precipitation ; therefore, when extracting genomic DNA, each group should use the same volume of genomic DNA eluent for volume normalization ( the amount of genomic DNA extracted from dead bacteria and live bacteria is inconsistent, so the concentration of the two is significantly different ). 9.Preparation of reaction mixture according to the following system : Note : 1 For the DNA extracted by commercial DNA extraction kit, the qPCR template was optimized with 2 µL as the initial volume ; 2 The template volume should not exceed 10 % of the final reaction volume ; 3 Template concentration : gDNA as template, usually 1-10 ng ; the final concentration of PCR primers is usually 0.4µM, which can get better results. When the reaction performance is poor, the primer concentration can be adjusted in the range of 0.2-1µM. 10.Slightly vortex the reaction mixture, transfer the fixed volume to the PCR tube. 11. Test procedure Note : 1 The extension time is adjusted according to the instrument ; the Taq enzyme in mix can be activated within 2 min, but the genomic DNA may require longer denaturation time, which can be increased at this time, and the specific denaturation time can be adjusted according to the sample type.12. ( Optional ) Data analysis Using live bacteria and dead bacteria as controls, the number of live cells in the sample was analyzed and calculated. It is recommended to verify the suitability of primers and PCR procedures before starting PMA qPCR detection of live bacteria. Calculation of dead and living bacteria control dCt ( 1 ) After the end of qPCR, the Ct value of each sample was calculated by instrument software ; ( 2 ) By calculating the dCt of each control bacteria, it was judged whether PMA successfully inhibited the amplification of dead bacterial DNA. The calculation is as follows : dCt live = Ct ( live, PMA treated ) -Ct ( live, PMA untreated ) dCt die = Ct ( die, PMA treated ) -Ct ( die, PMA untreated ) ( 3 ) The dCt expectation of living bacteria is close to 0 ± 1, which indicates that PMA does not affect the amplification of living cell DNA ;( 4 ) The expected value of dCt of dead bacteria is greater than 4 ( dCt is 4 means that it is reduced by about 16 times, that is, 94 % of dead bacterial DNA is removed ; a dCt of 8 indicated a decrease of about 250 times, that is, 99.6 % of the dead bacterial DNA was removed ).( 5 ) The dCt of dead bacteria depends on many factors, including : strain / cell type ; the way bacteria are killed ; the concentration of PMA used ; amplified sequence length. 13. Calculation of the proportion of viable ( optional ) bacteria If the control results of dead and live bacteria are normal, the proportion of live bacteria in the sample can be calculated.( 1 ) Calculate the dCt value of the sample : dCt sample = Ct ( sample, PMA treated ) -Ct ( sample, PMA untreated ) ( 2 ) Conversion of dCt value to live bacteria ratio : PMA inhibition multiple = 2 ( sample dCt ) Viable bacteria % = 100 / PMA inhibition multiple 14. ( Optional ) Calculate the absolute number of live bacteria If you want to calculate the absolute number of viable bacteria in the sample, you need to use a known number of target bacteria genomic DNA to make a standard curve. It is recommended that the diluted concentrations of several groups of genomes are within the range of the qPCR analysis system.( 1 ) qPCR was performed with the appropriate genome, and the Ct value was used as the ordinate, and the number of cells was used as the abscissa. The R2 value is calculated to determine the linearity, and the slope and y-axis intercept are displayed. ( 2 ) Calculate the copy number of the experimental samples : Ct = slope * cell number + y axis intercept ( y = mx + b ) Bacterial count sample = ( Ct-y axis intercept ) / slope Note : The live bacterial DNA was not lost during the purification process. Examples : Scope of application:Live bacteria detection... Read More | The Endo F Multi-Kit will deglycosylate N-linked glycans in both native and denatured conditions. Each enzyme has a distinct specificity for N-linked glycan release. One can choose to use the three enzymes in combination to completely remove all N-linked glycans present on a glycoprotein or peptide,The Endo F Multi-Kit will deglycosylate N-linked glycans in both native and denatured conditions. Each enzyme has a distinct specificity for N-linked glycan release. One can choose to use the three enzymes in combination to completely remove all N-linked glycans present on a glycoprotein or peptide, or to use each enzyme independently and thereby determine the type of N-glycans present.Product DescriptionThe Endo F Multi-kit is recommended to deglycosylate native proteins that are resistant to PNGase F cleavage under non-denatured conditions due to the glycan location within the protein’s three-dimensional structure, as these enzymes are known to be less sensitive to protein conformation.Each of the enzymes has a different N-linked glycan specificity:Endoglycosidase F1 cleaves high mannose and some hybrid type N-glycansEndoglycosidase F2 releases biantennary and high mannose glycans (at a 40X reduced rate)Endoglycosidase F3 will release triantennarry and fucosylated biantennary N-glycansContents1 vial: Endo F1- 20 µl (0.3 U)20 mM Tris-HCl pH 7.51 vial: Endo F2- 20 µl (0.1 U)10 mM sodium acetate, 25 mM NaCl, pH 4.51 vial: Endo F3- 20 µl (0.1 U)20 mM Tris-HCl pH 7.51 vial: 5x Reaction Buffer - 400 µl250 mM sodium acetate, pH4.51 vial: 5x Reaction Buffer - 400 µl250 mM sodium phosphate, pH5.5Specific ActivityDefined as the amount of enzyme required to catalyze the release of N-linked oligosaccharides from 1 micro-mole of denatured Ribonuclease B (Endo F1) or porcine fibrinogen peptides (Endo F2/F3) in 1 minute at 37°C, pH 5.5 (PH 4.5 for Endo F3). Cleavage is monitored by SDS-PAGE.FormulationThe enzymes are provided as a sterile-filtered solution.StabilitySeveral days exposure to ambient temperatures will not reduce activity. Stable at least 12 months when stored properly.SpecificityEndo F1 cleaves Asparagine-linked (N-linked) high mannose or hybrid oligosaccharides. Endo F2 cleaves N-linked biantennary oligosaccharides and high mannose (at a 40X reduced rate). Endo F3 cleaves free or N-linked fucosylated biantennary or triantennary oligosaccharides,as well as triamannosylchitobiose core structures. These enzymes cleave between the two N-acetylglucosamine residues in the diacetylchitobiose core of the oligosaccharide, generating a truncated sugar molecule with one N-acetylglucosamine residue remaining on the asparagine. The recombinant version is not glycosylated, which may result in properties differing from the native protein.Quality & PurityEndo F1, Endo F2, and Endo F3 are tested for contaminating protease as follows: 10 µg of denatured BSA is incubated at 37°C for 24 hours with 2 µl of enzyme. SDS-PAGE analysis of the treated BSA shows no evidence of degradation. The absence of exoglycosidase contaminants is confirmed by extended incubations with the corresponding pNP-glycosides. Directions for use 1. Add up to 200 µg of glycoprotein to an Eppendorf tube. Adjust to 34 µl final volume with de-ionized water. 2. Add 10 µl Endo F2 &F3 5x Reaction Buffer, 250 mM sodium acetate pH 4.5. Use Endo F1 buffer, 250 mM sodium phosphate pH 5.5 if you are using the Endo F1 enzyme alone. 4. Add 2.0 µl of each enzyme to the reaction. Incubate 3 hours at 37°C. Monitor cleavage by SDS-PAGE. Applications– Deglycosylation of native proteins resistant to PNGase F cleavage– Determination of glycan type (high mannose, biantennary, tri/tetrantennary)– Deglycosylating proteins which normally precipitate when deglycosylating– X-Ray CrystallographyThese three enzymes cleave asparagine-linked (N-linked) oligosaccharides between the two GlcNAc residues in the core of the oligosaccharide, generating a truncated sugar molecule with one N-acetylglucosamine residue remaining on the asparagine, enhancing the solubility of the protein. In contrast, PNGase F removes the oligosaccharide intact... Read More | Product content R669871Component50 TStorageR669871ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669871B10×Reaction Buffer1mL-20℃. Avoid freeze/thaw cycle. R669871CBuffer DS30 mLRTR669871DBuffer GTL15 mLRTR669871EBuffer GL25 mLRTR669871FProteinase K12.5 mgRTR669871GProteinase K Product content R669871Component50 TStorageR669871ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669871B10×Reaction Buffer1mL-20℃. Avoid freeze/thaw cycle. R669871CBuffer DS30 mLRTR669871DBuffer GTL15 mLRTR669871EBuffer GL25 mLRTR669871FProteinase K12.5 mgRTR669871GProteinase K Storage Buffer1.25 mLRTR669871HBuffer RW140 mLRTR669871IBuffer RW2 (concentrate)11 mLRTR669871JRNase-Free Water10 mLRTR669871KSpin Columns RS with Collection Tubes50 setsRTR669871LRNase-Free Centrifuge Tubes (1.5 mL)50 EART Product IntroductionThis kit is suitable for effectively purifying total RNA from formalin fixed and paraffin embedded tissues. Suitable for extracting total RNA with improved purity from paraffin embedded tissues or sections less than 30mg. This kit does not require the use of phenol/chloroform extraction or isopropanol precipitation, and can complete the extraction of multiple samples within one hour. This product uses specially optimized lysis solution and protease K to release RNA from formalin fixed or tissue slice samples without overnight operation; After digestion, the sample is incubated at a higher temperature to remove the inhibitory effect caused by formalin cross-linking, effectively releasing RNA from tissue slices and avoiding endangering RNA integrity; The optimized buffer system allows RNA in the lysis solution to specifically bind to the silica gel adsorption membrane, while other pollutants can flow through the membrane; It can be effectively removed through rinsing steps, and the washed RNA can be directly used for experiments such as RT-PCR, Real Time PCR, and Western blot analysis.Self prepared reagents: anhydrous ethanol (newly opened or dedicated for RNA extraction), 10mM PBS (pH 7.4).Preparation and important precautions before the experiment1. Add 0.625ml Protein K Storage Buffer to Protein K to dissolve it and store at -20 ℃. The prepared Protein K should not be left at room temperature for a long time to avoid repeated freeze-thaw cycles, which may affect its activity.2. To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.3. After obtaining the sample, it should be fixed in 4% -10% formalin as soon as possible, with a suitable fixation time of 14-24 hours. Excessive time can lead to RNA breakage and affect downstream experiments.4. Ensure that the sample before embedding is thoroughly dehydrated, as residual formalin will inhibit the action of Protein K.5. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.Before use, please check if there is any crystallization or precipitation in Buffer GTL, Buffer GL, and Buffer DS. If there is any crystallization or precipitation, please dissolve Buffer GTL, Buffer GL, and Buffer DS again in a 56 ℃ water bath.Operation steps1. Sample processing1a. Paraffin embedded sample: Use a surgical knife to trim off excess paraffin from the tissue block, expose the tissue, and cut into 5-10 µ m thin slices.Attention: If the surface of the sample has already been exposed to air, please discard 2-3 pieces that come into contact with the air and do not use them.1b. Samples in fixed solutions such as formalin: Take approximately 20mg of the sample, cut it into small pieces, place it in a centrifuge tube, and add 500 µ 10mM PBS (PH7.4), vortex oscillation, centrifugation at 12000 rpm (~13400 × g) for 1 minute, discard the supernatant, repeat 3 times, and proceed directly to step 3.2. Choose option A or option B to remove paraffinOption AA1. Take approximately 1 × 1cm2 of slices (4-5 slices in total) and place them in a centrifuge tube (prepared by oneself), then add 500 slices µ L Buffer DS, vortex oscillation for 10 seconds. Incubate at 56 ° C for 3 minutes.Centrifuge at A2.12000 rpm for 2 minutes, be careful to discard the supernatant and avoid attracting sediment.Option BB1. Take approximately 4-5 slices of approximately 1 × 1 cm2 and place them in a centrifuge tube (self prepared). Add 1ml of xylene, cover the tube tightly, and vortex for 10 seconds.B2.Centrifuge at 12000 rpm for 2 minutes, be careful to remove the supernatant and avoid removing sediment.B3. Add 1ml of anhydrous ethanol, vortex and shake well. Centrifuge at 12000 rpm for 2 minutes, discard the supernatant, and be careful not to absorb or discard the sediment.B4. Open the tube cover and incubate at room temperature or up to 37 ° C for 10 minutes until there is no ethanol residue.3. Add 150µ L Buffer GTL, resuspended precipitation; Join 10µl Protein K, vortex oscillation mixing.4.Incubate at 56 ℃ for 15 minutes until the sample is completely dissolved. Incubate at 80 ℃ for 15 minutes. Short centrifugation allows the solution on the tube wall to be collected to the bottom of the tube.Note: 1) The purpose of this step is to repair nucleic acids denatured by formaldehyde. Incubating at a high temperature or for too long may cause RNA breakage, resulting in RNA fragments.2) The sample incubated at 56 ℃ can be placed at room temperature until the temperature of the water or dry bath reaches 80 ℃, and then the sample can be incubated at 80 ℃.5. Place on ice for 3 minutes, centrifuge at 12000 rpm for 15 minutes, transfer the supernatant to a new centrifuge tube, be careful not to suck sediment.6. Add 320 to the supernatant µ L Buffer GL, vortex oscillation thoroughly mixed.7. Join 720 µ Mix anhydrous ethanol thoroughly with vortex oscillation.Attention: After adding anhydrous ethanol, there may be a small amount of precipitate precipitation, but it does not affect subsequent operations.8. Add all the solutions obtained in step 7 to the spin columns RS that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Optional steps: If genomic DNA needs to be removed, the following steps can be followeda. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 1 minute, discard the waste liquid, and place the adsorption column back into the recovery manifold.b. Preparation of DNase I mixture: Take 52 µ Add 8 RNase Free Water to it µ 10 x Reaction Buffer and 20 µ DNase I (1U/ µ l) Mix well and prepare to a final volume of 80 µ The reaction solution of L.c. Add 80 µ l of DNase I mixture directly to the adsorption column and incubate at 20-30 ℃ for 15 minutes.d. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 1 minute, discard the waste liquid, and place the adsorption column back into the recovery manifold.9. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.10. Repeat step 9.Centrifuge at 11.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).12. Place the adsorption column in a new RNase free centrifuge tube, and add 20-50µl to the middle of the adsorption column in the air Place RNase Free Water at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -20 ℃.Note: 1) The volume of RNase Free Water should not be less than 20 µ l. Small volume affects the recovery rate. 2) If you want to increase RNA production, you can use 20-50 µ Repeat step 12 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 12... Read More | This reagent kit is specially developed for one-step RT-PCR experiments. Reverse transcription and PCR are carried out in the same reaction system, without the need to add reagents or open the tube cap during the reaction process, which improves detection sensitivity and experimental efficiency This reagent kit is specially developed for one-step RT-PCR experiments. Reverse transcription and PCR are carried out in the same reaction system, without the need to add reagents or open the tube cap during the reaction process, which improves detection sensitivity and experimental efficiency while avoiding contamination. This kit includes a brand new high-efficiency reverse transcriptase, a fast hot start DNA polymerase, as well as reaction buffer suitable for reverse transcription and PCR amplification, and other components necessary for the experiment. The loss of activity of SuperRT reverse transcriptase RNase H reduces RNA degradation in reverse transcription reactions. This reverse enzyme has high reverse transcription efficiency and can perform good reverse transcription reactions on a small amount of RNA templates. The rapid hot start DNA polymerase used in PCR reaction has excellent performance of high amplification efficiency, strong specificity, and fast extension speed. The unique buffering system maximizes the efficiency of both reverse transcriptase and polymerase. The target product amplified using this reagent kit has an A base attached to the 3 'end, which can be directly used for T/A cloning.S665660Component100 TStorageS665660ASuperRT OneStep EnzymeMix50 µL-20℃. Avoid freeze/thaw cycle.S665660B2×SuperRT OneStep Buffer1.4 mL-20℃. Avoid freeze/thaw cycle.S665660CRNase-Free Water1.5 mL-20℃. Avoid freeze/thaw cycle. Notes:1. During the operation process, RNase contamination should be avoided to prevent RNA degradation or cross contamination during experiments. It is recommended to perform RNA operations in specialized areas, use specialized instruments and consumables, and have operators wear masks and disposable gloves, and frequently change gloves.2. Disposable plastic containers should be used as much as possible for experiments. If glass containers are used, they should be treated with a 0.1% DEPC (diethyl pyrocarbonate) aqueous solution at 37 ℃ for 12 hours, and sterilized under high pressure at 120 ℃ for 30 minutes before use. Alternatively, glass containers should be sterilized under dry heat at 180 ℃ for 60 minutes before use. The sterile water used in the experiment should be treated with 0.1% DEPC and then subjected to high-pressure sterilization.3. All reagents in this reagent kit should be gently mixed upside down before use, avoiding foaming as much as possible, and used after brief centrifugation. The enzymes involved should be returned to -20 ℃ as soon as possible after use to avoid repeated freeze-thaw cycles.4. This reagent kit must use specific primers, and the selection of primers can be based on specific experiments. The quality of primer design directly affects the results of RT-PCR reactions. When designing primers, factors such as GC content, primer length, primer position, and the secondary structure of PCR products need to be considered. It is recommended to use professional primer design software.Usage:1. Dissolve the RNA template, primers, OneStep RT-PCR Buffer, SuperRT OneStep RT-PCR EnzymeMix, and RNase Free Water and place them on ice for later use.2. Prepare the reaction system according to the following table: Reagent 25 µlReaction system Final concentration 2×SuperRT OneStep Buffer 12.5 µl 1× Forward Primer,10 µM 1 µl 0.4 µM Reverse Primer,10 µM 1 µl 0.4 µM SuperRT OneStep EnzymeMix 0.5 µl / RNA Template X µl 1 pg – 1 µg RNase-Free Water up to 25 µl / Attention: The primer concentration should be between 0.1 and 1.0 as the final concentration µ M serves as a reference for setting the range. In the case of low amplification efficiency, the concentration of primers can be increased; When non-specific reactions occur, the primer concentration can be reduced to optimize the reaction system.3. Vortex and shake well, centrifuge briefly, and collect the solution to the bottom of the tube.4. Preheat the thermal cycler to 45 ℃, place the PCR tube in the thermal cycler, and perform RT-PCR reaction.Reaction conditions: Step Temperature Time / Reverse transcription 45℃ 30 min / PCR pre denaturation 95℃ 2 min Denaturation 94℃ 30 s 30-40 cycles Anneal 55-65℃ 30 s 30-40 cycles Extend 72℃ 30 s 30-40 cycles Finally extended 72℃ 5 min /Attention:1) In general PCR experiments, the annealing temperature is 5 ℃ lower than the melting temperature Tm of the amplification primer, and the annealing time is generally 20-30 seconds. If the ideal amplification efficiency cannot be achieved, the annealing temperature should be appropriately reduced; When non-specific reactions occur, increase the annealing temperature to optimize the reaction conditions.2) The extension time is set based on the size of the amplified fragments, and the DNA Polymerase amplification efficiency contained in this product is 1 kb/30s.3) The number of cycles can be set based on the downstream application of the amplification product. Too few cycles, insufficient amplification; Multiple cycles increase the probability of mismatches and result in severe non-specific backgrounds. Therefore, while ensuring product yield, the number of cycles should be minimized as much as possible.5. After the reaction is complete, take 5 µ l of the reaction product, add an appropriate amount of loading buffer, and perform electrophoresis detection results... Read More | S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948D DNA Standard 2 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948E DNA Standard 3 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948F DNA Standard 4 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948G DNA Standard 5 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis product is used for real-time fluorescence quantitative PCR (qPCR) using the product after NGS library construction by dye method (SYBR Green I). The kit provides the reaction mixture, DNA primer mixture, and standards required for the qPCR process, and the reagent system is complete, easy and convenient to operate. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, and able to quickly and accurately quantify the concentration of the constructed library. It is suitable for fluorescent quantitative PCR instruments that do not require ROX as a calibration dye, such as Roche LightCycler 480, Roche LightCyler 96, Bio-radiCyleriQ, iQ5, CFX96.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Use 2.Scope of applicationThis product is designed for absolute quantification of the concentration of Illumina platform second-generation sequencing libraries. The end of the library contains Illumin P5 and P7 chip binding sequences, the length of which does not exceed 1kb, and the concentration of which is not less than 0.002pM can be used to perform quantitative experiments with this product. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-20 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR Master Mix10 µlqPCR Primer Mix 10.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: add 1 µl High Rox per 50 µl of reaction system;Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.qPCR reaction programThe annealing temperature should be 60-64°C as a reference for the setting range, and the annealing temperature can be increased when a non-specific reaction occurs.If the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.data analysisStandard curve productionThe standard curve was plotted using Ct values in the valid range. The standard curve correlation coefficient R2 should not be less than 0.99 and the slope should lie between -3.1 and -3.6. If the standard curve parameters are not reasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard 120 pMDNA Standard 22 pMDNA Standard 30.2 pMDNA Standard 40.02 pMDNA Standard 50.002 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More |