| Description | This reagent kit uses highly sensitive silver dye, which can be applied to protein staining of denatured and non denatured gels. It has the advantages of clear target bands, low background, and flexible control of operation time. In addition, this reagent kit has added a short-term sensitization This reagent kit uses highly sensitive silver dye, which can be applied to protein staining of denatured and non denatured gels. It has the advantages of clear target bands, low background, and flexible control of operation time. In addition, this reagent kit has added a short-term sensitization step, which can significantly reduce the background and enhance the brightness of the target band. P665901Component20 TStorageP665901ASilver Stain Sensitizer (500×)2×1 mLRTP665901BSilver Stain Enhancer3 mLRTP665901CSilver Stain2×250 mLRTP665901DSilver Stain Developer4×125 mLRT Matters needing attention1. Please prepare 50 ml of fixed solution (ultrapure water: ethanol: acetic acid=6:3:1), 50 ml of eluent (10% ethanol), and 50 ml of termination solution (5% acetic acid) in advance.2. Please use deionized water and clean glass or plastic containers during operation, and wear disposable gloves for operation.The entire silver dyeing process needs to be carried out on a shaker, with a rotation speed of about 60 rpm.4. Self prepared ethanol and glacial acetic acid are required.Instructions for useThe dosage of each solution in the following operation steps takes the gel with a size of 8.5 × 5.5 cm and a thickness of 1.0 mm as an example. The gel is immersed in the solution completely, and is operated on a shaker, with a general dosage of 25 ml. For large gel, the dosage of each solution should be scaled up according to the gel volume. Please prepare 50 ml of fixed solution (ultrapure water: ethanol: glacial acetic acid=6:3:1), 50 ml of eluent (10% ethanol), and 50 ml of termination solution (5% glacial acetic acid) in advance.1. Water washing: After electrophoresis is completed, wash the gel twice with ultrapure water for 5 minutes each time.2. Fixation: Fix the gel twice with 25 ml of fixative solution for 15 minutes each time.3. Elution: Wash the adhesive twice with eluent, each time for 5 minutes.4. Water washing: Wash the glue twice with ultrapure water, each time for 5 minutes.5. Sensitization: put the gel washed in the previous step into the silver dye sensitization working solution, incubate it accurately for 1 minute at room temperature, and then wash it with ultrapure water for three times, each time for 20 seconds. Preparation of silver staining sensitization working solution: Take 50 µ l Silver Stain Sensitivity (500 x) and add it to 25 ml of ultrapure water, mix well.6. Silver staining: discard ultrapure water and incubate gel in silver staining working solution for 30 minutes. Preparation of silver staining working solution: Take 25ml Silver Stain and add 50 µ l Silver Stain Enhanced to mix well.7. Water washing: Quickly wash the glue twice with ultrapure water, with each washing accurately controlled for 20 seconds.8. Development: Immerse the washed gel in the developer immediately and incubate it at room temperature for 2-3 minutes until the protein strip is clear. Preparation of developer: Take 25ml Silver Stain Developer and add 30 µ l Silver Stain Enhanced to mix well. Attention: Within 30 seconds of development, protein bands begin to appear and continue to develop for 2-3 minutes. If the protein band appears lighter, the development time can be appropriately extended to 5 minutes or more.9. Termination: After washing the developer on the gel with the termination solution, soak the gel in a new termination solution to react for 10 minutes.Experimental imagesSilver staining results of BSA protein samples after 10% SDS-PAGE gel electrophoresisThe molecular weight of BSA protein is about 66 kD, and the loading amounts from left to right are 50 ng, 10 ng, and 5 ng, respectively... Read More | Live & deadtm animal cell viability / toxicity detection kit (calcein am, ethd-i) is a kit that provides double fluorescent staining for the detection of animal cell death and survival. The two probes in the kit can respectively measure the activity of cellular lactonase and the integrity of Live & deadtm animal cell viability / toxicity detection kit (calcein am, ethd-i) is a kit that provides double fluorescent staining for the detection of animal cell death and survival. The two probes in the kit can respectively measure the activity of cellular lactonase and the integrity of plasma membrane to reflect cell viability. The kit can be used for fluorescence microscopy, flow cytometry, microplate reader and other fluorescence detection systems. This kit can be applied to most eukarYOtic mammalian cells, including some tissues with adherent nuclei, but it is not applicable to fungi and yeast. Compared with trypan blue, the kit is faster, safer and more sensitive.Component: Product parameters:Calcein am: ex/em = 494 / 517 nm; Ethd-i: ex/em = 528 / 617 nm (bound DNA)Usage:Fluorescence microscopy detection1. Prepare working fluidPreparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution: Remove the original solution of Calcein AM and EthD-I and restore them to room temperature. Add 20 µ L 2 mM EthD-I and 5 µ Mix 4 mM Calcein AM with 10 mL PBS or other serum-free buffer or culture medium, vortex well. The above working solution can be directly used for cell staining.Note: The aqueous solution of Calcein AM is easily hydrolyzed and should be used up every day. The concentration selection of Calcein AM and EthD-I varies depending on the type of cell used, with a recommended concentration range of 0.1-10 µ M.2. Prepare cells and conduct experiments(1) For adherent cells, they can be washed 2-3 times with 1 × PBS before staining. For suspended cells, centrifuge at room temperature of 250-1000 × g for 5 minutes and collect cells for staining.(2) Wash the cells thoroughly 2-3 times with 1 × PBS to remove residual esterase activity.(3) For adherent cells, add sufficient amount of Calcein AM/EthD-I staining solution. For suspended cells, add an appropriate amount of staining solution to control the cell density between 1-5 × 105/mL.(4) Incubate at room temperature in dark for 15-20 minutes (if the working solution concentration is high or the incubation temperature is high, the incubation time should be appropriately reduced).(5) Observe the labeled cells under a fluorescence microscope.Flow cytometry detection1. Remove the reagent and restore it to room temperature.2. Preparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution: Take out the original solution of Calcein AM and EthD-I, and restore to room temperature. Add 20 µ L 2 mMEthD-I and 5 µ Vortex mix 4 mM Calcein AM with 10 mL PBS or other serum-free buffer or culture medium. The working fluid can directly stain cells.3. Wash cells thoroughly 2-3 times with 1 × PBS.4. Suspend cells with 0.5 mL of staining solution and control the cell density to 1-5 × 105/mL.Note: It is recommended to prepare two additional cell samples, each containing only one dye (Calcein AM and EthD-I), for compensatory regulation of flow cytometry single staining; Prepare another cell sample containing only buffer solution (which should be consistent with the buffer used to prepare Calcein AM and EthD-I detection working solutions) as a negative control for flow cytometry analysis.5. Incubate at room temperature in dark for 15-20 minutes.6. Within 1-2 hours, cell activity was detected by flow cytometry. Calcein AM can be excited by a 488 nm laser, with fluorescence emission spectra detected at around 530 nm and EthD-I emission spectra at around 610 nm.Note: When using the cell circle gate, attention should be paid to excluding cell debris and using a single staining tube to regulate compensation. Double staining tube flow cytometry should obtain two relatively independent cell populations: a live cell population displaying green fluorescence and a dead cell population displaying red fluorescence.ELISA reader detection1. Cultivate an appropriate amount of adherent or suspended cells in a 96 well black ELISA plate.Note: Dead cells can be obtained by treating cells with 1% saponin or 0.1-0.5% digitalis saponin for 10 minutes.2. Preparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution:Remove the original solutions of Calcein AM and EthD-I and restore them to room temperature. Add 20 µ L 2 mM EthD-I and 5 µ Mix 4 mM Calcein AM 10 mL PBS or other serum-free buffer or culture medium, vortex well.Note: (1) 10 mL of staining solution is sufficient to stain a 96 well plate, and the volume of the staining solution can be adjusted according to experimental needs. The concentrations of Calcein AM and EthD-I can range from 0.1 to 10 µ Explore between M.(2) The aqueous solution of Calcein AM is easily hydrolyzed and should be used up every day. EthD-I working solution can be stored at -20 ℃ for at least one year.3. Wash the cells thoroughly with 1 × PBS to remove residual esterase activity. For adherent cells, add 100 to each well µ Wash cells with PBS. For suspended cells, add 100 µ Resuspend cells with L PBS and centrifuge to remove the supernatant. Repeat the above operation.4. Add 100 to each hole µ L PBS.5. Add 100 to each hole µ L staining solution, making the total volume of each well 200 µ L. The final concentration of Calcein AM is 1 µ M. The final concentration of EthD-I is 2 µ M. Gently shake the culture plate to evenly cover the cells with the liquid.Incubate at room temperature in dark for 30-45 minutes.Note: The optimal incubation time varies for different cells, with 30 minutes as the initial incubation time. Subsequently, the staining time can be adjusted and optimized according to the actual staining effect to obtain a more ideal staining effect.7. Enzyme reader detection. When the ELISA reader is set to fluorescein, it can detect Calcein AM; When the ELISA reader is set to rhodamine or Texas Red, EthD-I can be detected. Select the optimal emission and excitation wavelengths based on spectral characteristics.Note: By comparing the relative fluorescence values (RFU) measured between the sample group and the control group, the changes in the number of dead and live cells can be obtained. Another method of data analysis is also provided below.The following method can calculate the ratio of live cells to dead cells in a certain region. The required samples include dead cell control group, live cell control group, and the sample group to be tested. Dead cells can be obtained by treating cells with 1% saponin or 0.1-0.5% digitalis saponin for 10 minutes.1. Prepare staining solution and follow the above steps to stain cells. Additionally, prepare 1 mL and 2 mL separately µ M Calcein AM and 4 µ M EthD-I solution, stain the control group according to the following instructions. For the following groups of cells or cell-free groups, it is necessary to maintain complete consistency in cell count, detection of working solution concentration, incubation time, and incubation temperature.2. Measurement of sample group and control group:A. The measured values of the sample group at 645 nm are denoted as Calcein AM and EthD-I=F (645) sam.B. The measured values of the sample group at 530 nm are denoted as Calcein AM and EthD-I=F (530) sam.C. The measurement value of dead cell EthD-I single staining control group at 645 nm is denoted as EthD-I=F (645) maxD. The measurement value of dead cell Calcein AM single staining control group at 645 nm is recorded as Calcein AM=F (645) minE. The measurement value of live cell EthD-I single staining control group at 530 nm is recorded as EthD-I=F (530) min.F. The measurement value of live cell Calcein AM single staining control group at 530 nm is denoted as Calcein AM=F (530) max.G. A blank control well without cells (with or without dye), the detection value at 530 nm is recorded as F (530) 0.H. A blank control well without cells (with or without dye), the detection value at 645 nm is recorded as F (645) 0.3. Calculate the ratio of dead cells to live cells based on measurement data:%Live Cells=(B-E) ÷ (F-E)%Dead Cells=(A-D) ÷ (C-D)Determine the ratio of live cells to dead cells in a certain areaBy creating fluorescence spectral standard curves at 530 nm and 645 nm, the number of dead and live cells can be determined, and the fluorescence intensity of each dye is linearly related to the number of dead or live cells in the sample.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. phenol red or serum may interfere with the detection of this kit. 3. fluorescent dyes have quenching problems. Please try to avoid light during experimental operation to slow down fluorescence quenching. 4. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Dead and live cell staining (animal)... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Products contentN665989Component240 TStorageN665989AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/ Thaw cycle.N665989BlIndex N901-N924 Primers for Illumina24×10 µL-20℃. Avoid freeze/ Thaw cycle.Note: The amount of individual primers used is 1 µl, each N7-endProducts contentN665989Component240 TStorageN665989AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/ Thaw cycle.N665989BlIndex N901-N924 Primers for Illumina24×10 µL-20℃. Avoid freeze/ Thaw cycle.Note: The amount of individual primers used is 1 µl, each N7-end primer can perform 10 DNA library constructs, and each kit can perform 240 DNA library constructs. Products IntroductionThis kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Illumina platform library construction. Each kit contains one N5 primer and 24 N7 primers, which can be used to prepare 24 different single-ended Index libraries. All reagents provided in the kits have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes;Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers. ProcedureFor the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol.Index N501 Primer for IlluminaIndex N901-N996 Primer for Illumina... Read More | Product content: Component O66550510 preps O665505 50 preps Blocking Buffer 100 ml 500 ml Antibody Pretreat Solution( HRP/Mouse ) 1 ml 5 × 1 ml Dilution Buffer 100 ml 500 ml Wash Buffer( 10× ) 100 ml 500 mlProduct Introduction:The one-step rapid WB assay kit (Product content: Component O66550510 preps O665505 50 preps Blocking Buffer 100 ml 500 ml Antibody Pretreat Solution( HRP/Mouse ) 1 ml 5 × 1 ml Dilution Buffer 100 ml 500 ml Wash Buffer( 10× ) 100 ml 500 mlProduct Introduction:The one-step rapid WB assay kit (mouse) is the latest Western Blot detection kit developed by Kangwei Century, which can obtain high-quality Western Blot results in about 1 hour. It is easy to operate, has high detection sensitivity, low background, does not require the addition of secondary antibodies, and has strong system stability. The conventional Western Blot indirect detection process (blocking, primary antibody binding, and secondary antibody binding) requires a long time, a complex experimental process, and requires multi-step condition optimization. After transferring the protein on the gel to the carrier membrane, incubate it with the blocking solution in the reagent kit for 5 minutes, and then incubate the carrier membrane with the primary antibody treated with antibody reaction solution. After washing three times (5 minutes each time), luminescence or colorimetric detection can be performed. This reagent kit is designed for use in experimental systems where the target protein primary antibody is derived from mice.Notes:1. The customer prepares their own mouse source primary antibody.2. Before using Blocking Buffer blocking solution, Antibody Pretreat Solution (HRP/Mouse) antibody reaction solution (mouse), and Wash Buffer (10 x) rinse solution, please mix thoroughly.3. If there is precipitation in the rinsing solution when stored at 2-8 ℃, please restore it to room temperature, dissolve the precipitation, and use it normally. The 1x rinsing solution can be stored at room temperature for one month.4. It is recommended to stain the membrane with reagents such as spring red after the transfer is completed, and cut off any excess parts on the membrane to increase the efficiency of the reagents.5. The optimal dilution amount for primary antibody and antibody reaction solution HRP (mouse) needs to be determined through preliminary experiments.6. The antibody reaction solution HRP (mouse), antibody dilution solution, and antibody dosage can be increased or decreased proportionally according to the size of the membrane.7. The antibody dilution solution containing the first antibody can be recycled and reused once. It is recommended not to reuse antibodies with poor specificity and affinity. If the recovered antibody is used within 1-2 days and stored at 2-8 ℃ for long-term storage, please freeze it at -20 ℃ to avoid repeated freeze-thaw cycles.8. If there is a high background, please adjust the amount of antibodies and increase the number of times the film is washed.9. All reagents in the reagent kit should be stored at 2-8 ℃ to avoid freezing and thawing.Operation steps:This product is suitable for the sealing and antibody incubation steps after membrane transfer, taking a 5 cm x 8 cm membrane as an example:1. Preparation of rinsing solution: Dilute 10 ml of Wash Buffer (10 x) with distilled water to 100 ml, which is 1 x Wash Buffer. Set aside. Use 8-10 ml for each film wash.2. Sealing: After the membrane transfer is completed, immerse the membrane in 10 ml Blocking Buffer and seal at room temperature for 5 minutes.3. Rinse: Pour off the sealing solution, add 8-10 ml of 1 x Wash Buffer, and rinse at a high speed on a shaker for 1 minute.4. Prepare antibody incubation solution while washing the membrane: Take Antibody Pretreat Solution (HRP/Mouse) 100 µ Add mouse derived primary antibody 3-10 into the centrifuge tube µ g. Suck and beat the gun head until thoroughly mixed, and incubate at room temperature for 5 minutes. Add to 10 ml Dilution Buffer and mix well. Note: 1) The dosage of primary antibody can also be adjusted according to the dilution of the antibody. Taking the final dilution of antibodies at 1:1000 as an example, take 100 µ Add HRP (mouse) antibody reaction solution into the EP tube and add 10 µ Add the first antibody to 10 ml of antibody diluent, mix well, and incubate at room temperature for 5 minutes. 2) If the membrane area is small, the amount of antibodies, reaction solution, and diluent can be reduced proportionally.5. After completing step 3, pour out the rinsing solution and add the antibody incubation solution mixed with primary antibody, Antibody Pretreat Solution (HRP/Mouse), and Dilution Buffer to the membrane (ensuring that the incubation solution completely submerges the surface of the membrane). Incubate at room temperature on a shaker at around 60 rpm for 40 minutes.6. Discard (recover) the antibody incubation solution and rinse 3-5 times with the prepared 1 x Wash Buffer, each time for 3 minutes. 7. Conduct subsequent testing. It is recommended to use ECL or DAB methods for testing.Application examples:Example 1 Antigen is 293T cell lysateA: Normal WB control: beta actin mouse monoclonal antibody (CW0096) 5 µ Incubate at room temperature for 40 minutes, wash the film and dilute the secondary antibody sheep anti mouse HRP (CW0102) 1:10000. Incubate at room temperature for 40 minutes and expose ECL (CW0049).B: One step method WB: beta actin mouse monoclonal antibody (CW0096) 5 µ Incubate at room temperature for 40 minutes and expose ECL (CW0049).Example 2 Antigen is E. coli multi label protein lysateC: Normal WB control: GST mouse monoclonal antibody (CW0084) 2.5 µ Incubate at room temperature for 40 minutes, wash the film and dilute the secondary antibody sheep anti mouse HRP (CW0102) 1:10000. Incubate at room temperature for 40 minutes and expose ECL (CW0049).D: One step method WB: GST mouse monoclonal antibody (CW0084) was incubated at room temperature with 2.5ug for 40 minutes, and ECL (CW0049) was exposed... Read More |