| Description | Inquire | Cell proliferation detection is a basic experimental method to evaluate the health of cells, genotoxicity and the effect of antitumor drugs. The most accurate method to detect cell proliferation is the BrdU method. Edu detection kit is a revolutionary breakthrough of BrdU method. Edu (5-Cell proliferation detection is a basic experimental method to evaluate the health of cells, genotoxicity and the effect of antitumor drugs. The most accurate method to detect cell proliferation is the BrdU method. Edu detection kit is a revolutionary breakthrough of BrdU method. Edu (5-ethynyl-2 '- deoxyuridine) is a pyrimidine analog that integrates into the DNA duplex during DNA synthesis. Edu detection is based on the "click" reaction. A copper catalyzed azide reacts covalently with alkynes to form covalent bonds. In this kit, edu contains alkynes, Aladdin ® 488 / 555/594/647a azide dyes contain azide compounds. The edu labeling proliferation of click method is rapid and effective, and easy to use. BrdU method requires DNA denaturation (such as acid denaturation, thermal denaturation or digestion with DNase) to expose BrdU, so as to facilitate BrdU antibody binding; The edu method only needs paraformaldehyde fixation and Triton X-100 penetration to make the detection reagent enter the cells, and only a small amount of azide dye is needed to label the integrated edu very effectively. This kit contains all components required for edu method detection, and can be used for proliferation detection of cultured cells in vitro.Component:Product parameters:555/565 nm;Instruction: Experimental materials (self provided). 10 mM PBS, pH 7.2-7.6. 4% paraformaldehyde fixing solution (in PBS)Propensive reagent (0.5% Triton X -100 in PBS). 2 mg/mL glycine solution (in ddH2O). 3% BSA in PBS, pH 7.2-7.6. 1% BSA in PBS, pH 7.2-7.6. ddH2O. 96/24/12/6 well culture plate or dishFluorescence microscopy detection method1. Cell cultureTake logarithmic growth stage cells and inoculate them into a 96 well plate with 4 × 103-1 × 105 cells per well (the number and density of cells can be adjusted according to cell size, growth rate, and specific requirements of experimental treatment), and culture until normal growth stage.2. Drug treatmentPerform various drug treatments according to experimental needs.3. EdU marking(1) Dilute EdU solution (component A) in a certain proportion with complete cell culture medium to an appropriate concentration, then add it to the cells and mix well; Set up a negative control group without EdU treatment.Note: The labeling concentration of EdU needs to be adjusted according to cell type, and it is recommended to explore with an initial concentration of 10 µ M. In the pre experiment, it is recommended to set an EdU concentration gradient, which can be referred to in Tables 2 and 3.(2) Incubate in a cell culture incubator for 2 hours.Note: The optimal incubation time is related to the cell cycle. Most tumor cell lines can use a 2-hour incubation time, as shown in Appendix 2. The concentration of EdU is related to the incubation time, and high concentrations, such as 10-50, should be used for short-term incubation (<2 hours) µ M; Long term incubation (>24 hours) should use low concentrations, such as 1-10 µ M; You can also refer to Appendix 3.4. Cell fixation and permeation promotionNote: For experiments that require cell surface antigen labeling, it can be considered to wash the cells twice with a 3% BSA washing solution after completing EdU incubation, before cell fixation and permeation promotion.(1) After incubation, remove the culture medium. Wash cells twice with 1X PBS for 5 minutes each time to remove EdU residues that have not been incorporated into DNA. Cells with weak adhesion can reduce cleaning intensity. Join 50 µ After incubating at room temperature for 20 minutes with 4% paraformaldehyde fixative, remove the fixative.(2) Add 50 to each hole µ L 2 mg/mL glycine solution, incubate at room temperature for 5 minutes, and neutralize the remaining fixed solution.(3) At a rate of 100 per hole µ Wash cells twice with 3% BSA.(4) Remove the washing solution and add 100 µ L 0.5% Triton X -100, incubate at room temperature for 10 minutes.5. EdU detectionNote: Each sample in this reference step uses 100 µ The working fluid of L can be adjusted by users according to their own sample situation.(1) Prepare 1 x Click iT EdU reaction buffer (component C): Dilute component C 10 times with ddH2O.(2) Configure 5 x Click iT EdU buffer additives (component E): add 300 µ Mix L of ddH2O into a 30 mg E component tube (final concentration of 100 mg/mL) until completely dissolved. After use, the remaining storage solution is stored at -20 ℃ and can be stored for one year. Once the solution turns brown, it indicates that the active ingredients have degraded and cannot be reused.Note: Different specifications of component E are dissolved in ddH2O according to this ratio, and prepared into a 5 x storage solution for future use.(3) Prepare 1 x Click iT EdU buffer additive: Dilute 5 x Click iT EdU buffer additive with ddH2O to 1 x, and the solution should be prepared and used immediately.(4) Prepare Click it working solution according to Table 1.Table 1 Click it working fluidReaction componentsTaking the sample size of 10 holes as an example1×Click-iT EdU Reaction buffer855 µLCuSO4 (Component D)40 µLYF® 488/555/594/647A Azide(Component B)5 µL1×Click-iT EdU Buffer additives100 µLTotal volume1 mL(5) Remove penetration enhancer, 100 per well µ Wash twice with 3% BSA washing solution of L.(6) Add 100 to each hole µ L Click iT working solution, evenly covering cells.(7) Incubate at room temperature in dark for 30 minutes.(8) Remove Click-iT working fluid and add 100 µ After washing cells twice with 3% BSA, remove the washing solution and add 100 µ L PBS keeps cells moist. If there are no other special requirements, photography analysis can be carried out.6. DNA re staining (optional)(1) Using 100 µ Wash the cells once with PBS and remove the washing solution.(2) Dilute Hoechst 33342 (component F) 2000 times with PBS.(3) Add 100 to each hole µ Incubate L 1 x Hoechst 33342 solution at room temperature in dark for 15-30 minutes.(4) Remove Hoechst 33342 solution and use 100 µ Wash cells twice with PBS.7. Imaging and analysisIt is recommended to take fluorescence microscopy photos immediately after staining is completed for observation; If conditions permit, please store in a dark and moist environment at 4 ° C for 3 days before taking photos. Flow cytometry detection method1. Cell cultureInoculate 1 × 105~3 × 106 cells per well into a 6-well plate.2. Drug treatmentPerform various drug treatments according to experimental needs.3. EdU labeled cells(1) Dilute EdU solution (component A) in a certain proportion with complete cell culture medium to an appropriate concentration, then add it to the cells and mix well; Set up a negative control group without EdU treatment.Note: The labeling concentration of EdU needs to be adjusted according to cell type, and it is recommended to explore with an initial concentration of 10 µ M. In the pre experiment, it is recommended to set an EdU concentration gradient, which can be referred to in Tables 2 and 3.(2) Incubate in a cell culture incubator for 2 hours. The time of EdU incubation of cells can be directly used as an indicator for measuring cell DNA synthesis, and the choice of time point and incubation time depend on the cell growth rate. Pulse labeled cells incubated with brief EdU can be used to study cell cycle dynamics.Note: The optimal incubation time is related to the cell cycle. Most tumor cell lines can use a 2-hour incubation time, as shown in Appendix 2. The concentration of EdU is related to the incubation time, and high concentrations such as 10-50 should be used for short-term incubation (<2 hours) µ M; Long term incubation (>24 hours) should use low concentrations, such as 1-10 µ M; You can also refer to Appendix 3.4. Cell fixation and permeation promotionNote: For experiments that require cell surface antigen labeling, it can be considered to wash cells twice with 1% BSA after completing EdU incubation, before cell fixation and permeation promotion.(1) After incubation, collect cells, add 1 mL of PBS to each tube to clean the cells, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant to remove EdU residue that has not been added to DNA.(2) Add 1 mL of 4% paraformaldehyde fixative to each tube to resuspend cells.(3) Incubate at room temperature for 20 minutes, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant.(4) Add 1 mL of 2 mg/mL glycine to each tube and incubate for 5 minutes. Neutralize the remaining fixed solution, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant. Add 1 mL of PBS to each tube for cleaning once, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant.(5) Add 1mL of 0.5% Triton X-100 osmotic enhancer to each tube and resuspend cells. Incubate at room temperature for 10 minutes.5. EdU detectionNote: For 6-well plate samples, reference can be made to 1 mL of working solution per well. Users can adjust the dosage according to their own sample situation.(1) Prepare 1 x Click iT EdU reaction buffer: Dilute component C 10 times with ddH2O.(2) Prepare 5 x Click iT EdU buffer additives (component E): Add 300 µ L ddH2O to 30 mg of component E in a test tube (final concentration 100 mg/mL), mix well until completely dissolved. After use, the remaining storage solution is stored at -20 ℃ and can be stored for one year. Once the solution turns brown, it indicates that the active ingredients have degraded and cannot be reused.Note: Different specifications of component E are dissolved in ddH2O according to this ratio to form 5 x storage solution for future use.(3) Prepare 1 x Click iT EdU buffer additive: Dilute 5 x Click iT EdU buffer additive storage solution with ddH2O to 1 x, and the solution should be prepared and used immediately.(4) Prepare Click it working solution according to Table 2.Table 2 Click it working fluidReaction componentsVolume of liquid required for a single reaction1×Click-iT EdU Reaction buffer875 µLCuSO4 (Component D)20 µLYF® 488/555/594/647A Azide(Component B)5 µL1×Click-iT EdU Buffer additives100 µLTotal volume1 mL(5) Soak at 1000 rpm for 5 minutes, discard the supernatant, remove the enhancer, add 1mL of 1% BSA washing solution to each tube and wash twice. Soak at 1000 rpm for 5 minutes, discard the supernatant.(6) Add 1 mL of Click iT working solution to each tube and mix well.(7) Incubate at room temperature in dark for 30 minutes.(8) Soak at 1000 rpm for 5 minutes, discard the staining reaction solution, add 1% BSA to each tube to wash the cells twice, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and resuspend the cells again with 1 mL of 1% BSA (the volume of resuspend cells can be adjusted according to the number of cells), and detect with a flow cytometer.Note: If other biomarker tests are required, please refer to step 4.6. Intracellular antigen labeling (optional steps)(1) Add antibody working solution and mix well.(2) Under dark conditions, incubate antibodies at appropriate temperature and time.7. Flow detection and analysis:(1) It is recommended to conduct flow cytometry testing immediately after dyeing is completed; If conditions are limited, please store in a dark place at 4 ℃ for testing, but it should not exceed 3 days.(2) It is recommended to test the number of cells up to one million levels as much as possible. If the number of cells is small, the number of cells tested can be adjusted to 100000 levels starting from the experiment. For cases where the cell yield is too low (just to the level of ten thousand), it may not be conducive to making a flow chart. Therefore, the cleaning frequency in step 5 (8) can be appropriately reduced.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. fluorescent dyes have quenching problems. Please try to avoid light during experimental operation to slow down fluorescence quenching. 3. click it edu buffer additive solution should be prepared and used immediately to ensure the best results. 4. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Cell proliferation detection (cell imaging flow universal)... Read More | Annexin V ( annexin-V ) is a Ca2 + dependent phospholipid binding protein with a molecular weight of 35-36 KD, which can selectively bind to phosphatidylserine ( PS ). Phosphatidylserine ( PS ) is mainly distributed in the inner side of the cell membrane, that is, the side adjacent to the cytoplasm.Annexin V ( annexin-V ) is a Ca2 + dependent phospholipid binding protein with a molecular weight of 35-36 KD, which can selectively bind to phosphatidylserine ( PS ). Phosphatidylserine ( PS ) is mainly distributed in the inner side of the cell membrane, that is, the side adjacent to the cytoplasm. In the early stage of apoptosis, different types of cells will turn phosphatidylserine out to the cell surface and expose to the extracellular environment. At this time, using Annexin V labeled with fluorescent protein PE, that is, Annexin V-PE, combined with phosphatidylserine ( PS ), the eversion of phosphatidylserine, an important feature of apoptosis, can be directly detected by flow cytometry. Normal cells will not be stained by Annexin V-PE, apoptotic or necrotic cells will be stained by Annexin V-PE. Annexin V-PE can be used in combination with partially non-permeable nuclear dye ( 7-AAD / PI ) to distinguish cells at different stages of apoptosis. RedNucleus II provided in this kit is a far-red dye that belongs to an anthraquinone compound and cannot penetrate the intact cell membrane of living cells and early apoptotic cells. It is non-permeable, but can quickly stain the nucleus / dsDNA in dead and permeable cells. RedNucleus II is an ideal substitute for propidium iodide ( PI ) and 7-AAD.Combined with Annexin V-PE, it has better spectral characteristics without compensation regulation : it is not excited by ultraviolet light and does not overlap with PE / PE homologues, so it can be combined with FITC, PE and purple fluorescent dyes for multicolor analysis. When combined with Annexin V-PE, RedNucleus II was excluded from living cells and early apoptotic cells, while late apoptotic cells and dead cells were double-positive for Annexin V-PE and RedNucleus II. Annexin V-PE / RedNucleus II apoptosis detection kit can be detected by flow cytometry or other fluorescence detection equipment. Components: Components A598354(10T) A598354(50T) A598354(100T) A. 1×Annexin V Combining buffer solution 10 mL 50 mL 50 mL×2 B. Annexin V-PE 50 µL 250 µL 500 µL C. RedNucleus II 100 µL 500 µL 1 mLProduct parameters:Annexin v-pe:ex/em=488/578 nmrednucleus ii:ex/em=635/695 NMUsage method:1. Experimental design: Blank tube: Negative control group cells, without Annexin V-PE/RedNucleus II. Used to regulate voltage.Single staining tube: Positive control group cells were treated with Annexin V-PE alone/RedNucleus II alone. Used for adjusting compensation.Detection tube: Add Annexin V-PE/RedNucleus II to the processed cells. After adjusting the voltage compensation using blank tubes and single dye tubes, obtain the required flow data.2. Collect cells(1) For suspended cells:a. After inducing cell apoptosis, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, collect the cells, gently resuspend the cells in PBS, and count them.Note: PBS resuspension cannot be omitted. The process of PBS resuspension also serves to wash cells, ensuring the subsequent binding of Annexin V-PE.b. Take 5 × 104-1 × 105 resuspended cells, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and add 100 µ L of 1 × Annexin V binding buffer to gently resuspend the cells. c. Add 5 µ L Annexin V-PE and mix gently.d. Add 5 µ L of RedNucleus II staining solution and mix gently.e. Incubate at room temperature (20-25 º C) in the dark for 15 minutes. Aluminum foil can be used to avoid light. During the incubation process, cells can be resuspended 2-3 times to improve staining efficiency.(2) For adherent cells:a. Suck out the cell culture medium into a suitable centrifuge tube, wash the adherent cells with PBS once, and add an appropriate amount of trypsin cell digestion solution (without EDTA) to digest the cells. Incubate at room temperature until gently blowing can remove the trypsin cell digestion solution when the adherent cells are blown down. Overdigestion of pancreatic enzymes should be avoided.Note: For adherent cells, the trypsin digestion step is crucial. If the trypsin digestion time is too short, cells need to be blown hard to detach, which can easily cause damage to the cell membrane and lead to false positives of cell necrosis; If the digestion time is too long, it can also cause cell membrane damage and false positives of cell necrosis, and even affect the binding of phosphatidylserine and Annexin V-PE on the cell membrane, thereby interfering with the detection of cell apoptosis.b. Add the cell culture medium collected in the previous step, gently blow down the cells, transfer them to a centrifuge tube, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, collect the cells, gently resuspend the cells in PBS and count them.Note: Adding the cell culture medium from the previous step is very important. On the one hand, it can collect cells that have already been suspended and undergone apoptosis or necrosis. On the other hand, the serum in the cell culture medium can effectively inhibit or neutralize residual trypsin. The residual trypsin will digest and degrade the subsequently added Annexin V-PE, leading to staining failure.c. Take 5 × 104-1 × 105 resuspended cells, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and add 100 µ L of 1 × Annexin V binding buffer to gently resuspend the cells. d. Add 5 µ L Annexin V-PE and mix gently.e. Add 5 µ L of RedNucleus II staining solution and mix gently.f. Incubate at room temperature (20-25 º C) in the dark for 15 minutes. Aluminum foil can be used to avoid light. During the incubation process, cells can be resuspended 2-3 times to improve staining efficiency.3. Result analysis:(1) Flow cytometry detection:a. After incubation, 400 µ L of 1 × Annexin V binding buffer can be directly added to resuspend the cells, and immediately detected on the machine. Annexin V-PE is excited by 488 nm/566 nm laser, and the fluorescence emission spectrum is detected at 578 nm (BL2 (FL2)/YL1 channel), while the RedNucleus II channel emission spectrum is approximately at 695 nm (RL1 (FL4) channel).b. On the scatter plot of the bivariate flow cytometer, live cells are shown in the lower left quadrant, which is (Annexin V-PE -/RedNucleus II -); The lower right quadrant represents early apoptotic cells, which are (Annexin V-PE+/RedNucleus II -); The upper right quadrant represents necrotic and late stage apoptotic cells, which are (Annexin V-PE+/RedNucleus II+); The upper left quadrant displays naked nuclear cells, which are (Annexin V-PE -/RedNucleus II+).(2) Fluorescence microscopy detection:a. Centrifuge at 1000 rpm for 5 minutes, collect cells, and gently resuspend them in 400 µ L of 1 × Annexin V binding buffer. Transfer the cells to a 96 well plate and settle for a moment or perform cell smear, then observe under a fluorescence microscope.b. Annexin V-PE is compatible with PE filters. RedNucleus II can use a far red long pass filter.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. to reduce the process of apoptosis, the incubation process can be operated on ice, but the incubation time should be extended to at least 30 min. 3. as apoptosis is a rapid process, it is recommended that samples be analyzed within 1 h after staining. 4. for adherent cells, digestion is a key step. If there are floating cells when adherent cells induce apoptosis, the floating cells and adherent cells should be collected and stained. Handle adherent cells with care to avoid artificial damage to cells. The trypsin digestion time is too short, and the cells need to be blown hard to fall off, which is easy to cause damage to the cell membrane and excessive intake of rednucleus II; If the digestion time is too long, the cell membrane is also prone to damage, and even affect the binding of phosphatidylserine and annexin v-pe on the cell membrane. When digesting, spread pancreatin on the bottom of the well plate, fully contact the pancreatin with the cells when shaking gently, then pour out most of the pancreatin, use the remaining small amount of pancreatin to digest for a period of time, and terminate when the gap between cells increases and the bottom of the bottle is spotted. Try not to use EDTA in the digestive juice, which will affect the binding of annexin V to PS. 5. after the adherent cells are digested with trypsin, it is recommended to stain after recovering in the optimal culture conditions and medium for about 30 min to avoid false positives. 6. in order to avoid losing cells when washing cells, you can use a large tip over a small tip to aspirate. 7. the optimal concentration of dye is determined by the specific experimental requirements. 8. fluorescent dyes have quenching problems. Please try to avoid light during storage and use to slow down fluorescence quenching. 9. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Early apoptosis detection, annexin V Kit... Read More | B665530 Component 50 T 200 T Storage B665530A Buffer RCL 125 mL 2×260 mL 2-8℃ B665530B Buffer GR 15 mL 50 mL RT B665530C Buffer GL 15 mL 50 mL RT B665530D Buffer GW1 (concentrate) 13 mL 52 mL RT B665530E Buffer GW2 (concentrate) 15 mL 50 mL RT B665530F Buffer GE 15 mL 60 mL RT B665530G B665530 Component 50 T 200 T Storage B665530A Buffer RCL 125 mL 2×260 mL 2-8℃ B665530B Buffer GR 15 mL 50 mL RT B665530C Buffer GL 15 mL 50 mL RT B665530D Buffer GW1 (concentrate) 13 mL 52 mL RT B665530E Buffer GW2 (concentrate) 15 mL 50 mL RT B665530F Buffer GE 15 mL 60 mL RT B665530G Proteinase K 1.25 mL 4×1.25 mL RT B665530H Spin Columns DM with Collection Tubes 50 sets 200 sets RTProduct IntroductionThis reagent kit is suitable for extracting total DNA, including genomic DNA, mitochondrial DNA, and viral DNA, from fresh or frozen whole blood (blood samples treated with anticoagulants such as citrate, EDTA, or heparin), plasma, serum, erythrocyte sedimentation rate brown layer, lymphocytes, cell-free body fluids, and other samples. This product can process 0.1-1 mL of whole blood with a maximum yield of 30% µ g. It can purify DNA with sizes ranging from 100 bp to 50 kb. The purified DNA has high yield and good quality, and can remove protein, pigment, lipid, and other inhibitory impurities to the maximum extent. It can be directly used for PCR, fluorescence quantitative PCR, enzyme digestion, and Southern Blot experiments.Self prepared reagent: anhydrous ethanol.Preparation and important precautions before the experiment:1. The sample should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2. This reagent kit can extract up to 0.1-1 mL of whole blood samples or 1 × 107 white blood cells.3.Before the first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in the Buffer GL. If there is any crystallization or precipitation, please incubate the Buffer GL in a 56 ℃ water bath and dissolve it again.5. The Buffer RCL in the reagent kit cannot be used again after being turbid.Operation steps:1. Sample processing: 1a When extracting 200 uL of blood sample, add the sample to the centrifuge tube (provided) and proceed directly to the next step of the experiment. 1b When the blood sample size is less than 200 µ When L, add Buffer GR to make up for 200 µ L. Proceed to the next step of the experiment. 1c When the blood sample size exceeds 200 µ When L is reached, add 1-2 times the volume of Buffer RCL, gently vortex or invert and mix well. Centrifuge at 12000 rpm (~13400 × g) for 1 minute and carefully discard the supernatant. If there is still red in the sediment, repeat the above steps once. Then add 200 to the precipitate µ Shake the buffer GR until thoroughly mixed before proceeding to the next step of the experiment. 1d If the processed blood sample is anticoagulant from poultry, birds, amphibians, or lower level organisms, its red blood cells are nucleated cells, and the blood sample size is 5-20 µ L. Can be added to Buffer GR to make up to 200 µ Follow up experiments will be conducted afterwards. Note: If downstream experiments are sensitive to RNA, 4 can be added µ L RNase A (100mg/mL) solution, shake for 15 seconds, and leave at room temperature for 5 minutes. RNase A reagent kit is not provided. If needed, you can order it separately from our company, item number: CW0601S.2. Add 20 to the above solution µ L Protein K, mix well.3. Add 200 µ Shake with L Buffer GL until thoroughly mixed. Note: Do not pre mix Protein K and Buffer GL.4.Incubate at 4.56 ℃ for 10 minutes, invert and mix several times during this time. Attention: The DNA production has reached its maximum after 10 minutes of incubation, and further extension of incubation time has no effect on DNA production and purity.5. Add 200 µ L anhydrous ethanol, invert and mix several times. Short centrifugation causes the liquid on the tube wall and wall cover to concentrate at the bottom of the tube.6. Add all the solution obtained in step 5 to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. Note: If the extracted sample is the blood genome of species such as mice or monkeys that are difficult to remove heme, it is recommended to repeat step 7.8. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. Note: To further improve DNA purity, repeat step 8.9.Centrifuge at 9.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.)10. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃. Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high. 2) If the final concentration of DNA needs to be increased, the obtained DNA eluent can be added back to the adsorption membrane, left at room temperature for 2-5 minutes, and centrifuged at 12000 rpm for 1 minute. 3) Because DNA stored in water is affected by acidic hydrolysis, if long-term storage is required, it is recommended to elute with Buffer GE and store at -20 ℃... Read More | Products contentN665993Component240 TStorageN665993AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/ Thaw cycle.N665993BIndex N925-N948 Primers for Illumina24×10 µL-20℃. Avoid freeze/ Thaw cycle. Products Introduction This kit is a companion kit to the transposase-Products contentN665993Component240 TStorageN665993AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/ Thaw cycle.N665993BIndex N925-N948 Primers for Illumina24×10 µL-20℃. Avoid freeze/ Thaw cycle. Products Introduction This kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Illumina platform library construction. Each kit contains one N5 primer and 24 N7 primers, which can be used to prepare 24 different single-ended Index libraries. All reagents provided in the kits have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes;Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers. ProcedureFor the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol.Index N501 Primer for IlluminaIndex N901-N996 Primer for Illumina... Read More |