| Description | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Bacterial protein extraction reagents use mild non-ionic detergents and are suitable for extracting recombinant proteins expressed in Escherichia coli and insect cells. During the extraction process, there is no need for ultrasonic fragmentation, effectively avoiding contamination of exogenous Bacterial protein extraction reagents use mild non-ionic detergents and are suitable for extracting recombinant proteins expressed in Escherichia coli and insect cells. During the extraction process, there is no need for ultrasonic fragmentation, effectively avoiding contamination of exogenous proteins. This product can be applied to extract soluble proteins from bacterial lysates. The bacterial protein extraction kit adds a mixture of lysozyme, DNase I, and protease inhibitors to the extraction reagent, which can improve the efficiency of protein extraction and reduce the viscosity caused by DNA, effectively avoiding protein degradation. The extracted protein maintains biological activity and can be subjected to downstream operations such as IP, Western blot, and protein purification. Component B665764 100 preps Bacterial Protein Extraction Reagent 100 ml Protease Inhibitor Cocktail (100x) 1 ml Lysozyme (50 mg/ml) 200µl DNaseⅠ(1,000 U/ml) 100µl Notes:1. This product is suitable for extracting proteins from fresh or frozen bacterial and insect cells.2. This product uses Tris buffer system. Please use the same buffer system for protein purification after extraction.3. The protein lysis solution obtained from this product can be used for protein quantification using BCA or Bradford method.4. For special strains, if the extraction effect is not ideal, the sample can be frozen before protein extraction.5. Depending on the specific situation, protease inhibitors, salts, chelating agents, reducing agents, etc. can be added to this product.Operation steps: ● Insect cell protein extraction1. Collect cells by low-speed centrifugation. Add 10 to every 1 ml of Bacterial Protein Extraction Agent µ The Protein Inhibitor Cocktail is 1 x working fluid.2. Weigh the wet weight of the cells and add 1 x working solution at a rate of 10 ml/g.3. After resuspension, incubate on ice for 20 minutes (the ice storage time should be adjusted according to different cell types).Centrifuge at 4.15000 × g for 15 minutes to isolate soluble proteins. ● Extraction of soluble bacterial proteins 1. Centrifuge for 10 minutes at a rate of 5000 × g and collect the bacterial cells.2. Optional steps: Add 1 ml of Bacterial Protein Extraction Reagent every 1 ml µ DNase I (1000 U/ml), 2 µ Lysozyme (50 mg/ml) and 10 µ Protein Inhibitor Cocktail, vortex oscillation and mixing. 3. Add 20 ml of Bacterial Protein Extraction Reagent to each gram of bacterial precipitate, and add the extraction solution to the bacterial precipitate. Vortex thoroughly or use a pipette to blow up and down until the bacterial precipitate is completely resuspended.4. After resuspension, incubate at room temperature for 10-15 minutes (the storage time should be adjusted according to different cell types). 5. Centrifuge at 15000 × g for 5 minutes.6. Transfer the supernatant to a new centrifuge tube (the supernatant is soluble protein) for protein quantification and downstream experiments.Note: If the target protein exists in the form of inclusion bodies, inclusion body protein solution can be used for dissolution or expression conditions can be optimized to increase the expression of soluble proteins.Frequently asked questions: Problem Possible reasons Resolvent The target protein is insoluble The target protein is expressed as an inclusion body Optimize expression conditions or add Lysozyme and DNase I to protein extraction reagents using inclusion body protein solution After adding Lysozyme, the target protein has not been extracted yet Temperature too low Restore the reagent to room temperature After adding Lysozyme, the target protein has not been extracted yet Lysozyme Decreased or inactivated activity Add more Lysozymes or replace with new enzymes Extract has high viscosity DNase I Decreased or inactivated activity Add more DNase I or replace with a new DNase I to increase the final concentration of magnesium ions to 2 mM After protein extraction, most of the proteins still exist in the precipitate Excessive protein content Add Lysozyme and DNase I The protein extraction reagent has sediment precipitation Temperature too low Restore the protein extraction reagent to room temperature... Read More | DescriptionCobalt is a transition metal that serves as a trace dietary mineral for all multicellular organisms. Cobalt is an important cofactor for the Vitamin B12class of compounds where it occupies the center of the vitamin B12corrin ring. Cobalt can also be coordinated in the active site of the DescriptionCobalt is a transition metal that serves as a trace dietary mineral for all multicellular organisms. Cobalt is an important cofactor for the Vitamin B12class of compounds where it occupies the center of the vitamin B12corrin ring. Cobalt can also be coordinated in the active site of the non-corrin containing metalloenzyme methionine aminopeptidase.Suitability: Suitable for quantitating cobalt concentrations in a variety of samplesPrinciple: The Cobalt Assay kit provides a simple and direct procedure for measuring cobalt in a variety of samples. In this assay, cobalt reacts with 2-mercaptoethanol under basic conditions to form a complex with a strong absorbance at 475 nm. Interference from the metal ions Fe2+, Cu2+, Ni2+, Zn2+, and Mn2+is <10% at this wavelength. This assay gives a linear range of 10-50 nmoles of cobalt.}Preparation instructionsSuitable for quantitating cobalt concentrations in a variety of samplesPrincipleThe Cobalt Assay kit provides a simple and direct procedure for measuring cobalt in a variety of samples. In this assay, cobalt reacts with 2-mercaptoethanol under basic conditions to form a complex with a strong absorbance at 475 nm. Interference... Read More | DescriptionProvides an inert environment to run oxygen sensitive cross-coupling reactions in a laboratory fume hood.Designed to be used with KitAlysis High-Throughput Screening Kits and KitAlysis 24-Well Reaction Block | This reagent kit is for research purposes only. Purpose of use: This reagent kit is used to determine the content of lactose in serum, plasma, and related liquid samples.Experimental principle:This kit applies enzyme-linked immunosorbent assay to determine the level of lactose in the sample. This reagent kit is for research purposes only. Purpose of use: This reagent kit is used to determine the content of lactose in serum, plasma, and related liquid samples.Experimental principle:This kit applies enzyme-linked immunosorbent assay to determine the level of lactose in the sample. Purified lactose antibodies were coated on a microplate to produce solid-phase antibodies. Lactose was added to the microplate of the coated monoclonal antibody, along with HRP labeled lactose antigens, to compete for binding. After thorough washing, the substrate TMB was added for colorimetry. The depth of sample color is negatively correlated with the content of lactose in the sample. Measure the absorbance (OD value) at a wavelength of 450nm using an enzyme-linked immunosorbent assay (ELISA) reader, and calculate the content of lactose in the sample through a standard curve.Kit composition:130times concentrated washing solution20ml×1 bottle8.1Standard S1(80µg/L)0.5ml×1bottle2Enzyme-linked immunosorbent assay6ml×1 bottle8.2Standard S2(40µg/L)0.5ml×1bottle3Enzyme labeling coated plate96 holes x 1 pieces8.3Standard S3(20µg/L)0.5ml×1bottle4Color reagent A solution6ml×1 bottle8.4Standard S4(10µg/L)0.5ml×1bottle5Color developer B solution6ml×1 bottle8.5Standard S5(5µg/L)0.5ml×1bottle6Stop solution6ml×1 bottle9Instructions1 copy7Sample Diluent6ml×1 bottle10Microplate Sealers2 sheetsSpecimen requirements:1. Specimen processing:(1) After collecting the water sample, it is repeatedly freeze-thawed three times at -20 ℃, and then filtered through glass fiber for future reference(2) The tissue samples should be extracted using butanol: methanol: water (5:25:70 V: V: V), or extracted according to relevant literature. The experiment should be conducted as soon as possible after extraction. If the experiment cannot be conducted immediately, the specimen can be stored at -20 ℃ for future reference2. Samples containing NaN3 cannot be detected as NaN3 inhibits the activity of horseradish peroxidase (HRP).Operation steps:1. Sample addition: Set up standard wells, blank wells (blank control wells do not include samples and enzyme-linked immunosorbent assay reagents, the other steps are the same), and sample wells to be tested. Add 50 microliters to the standard well on the enzyme-linked immunosorbent assay (ELISA) plate, and first add 40 diluents to the sample well to be tested µ l. Then add 10 more samples to be tested µ L (The final dilution of the sample is 5 times). Add the sample to the bottom of the enzyme-linked immunosorbent assay (ELISA) plate well, avoiding touching the well wall as much as possible. Gently shake and mix well.2. Enzyme addition: Add 50 enzyme labeled reagents to each well µ l. Excluding blank holes.3. Warm incubation: Seal the plate with a sealing film and incubate at 37 ℃ for 60 minutes.4. Solution preparation: Dilute 30 times the concentrated washing solution with distilled water and set aside for later use5. Washing: Carefully remove the sealing film, discard the liquid, shake dry, fill each well with washing solution, let it stand for 30 seconds, then discard. Repeat this process 5 times and pat dry.6. Color development: Add color development agent A50 to each well first µ l. Add color developer B50 again µ l. Gently shake and mix well, and develop color at 37 ℃ in the dark for 15 minutes7. Termination: Add 50% termination fluid to each hole µ l. Terminate the reaction (at this point, the blue color immediately turns yellow).8. Measurement: Zero the blank hole and sequentially measure the absorbance (OD value) of each hole at a wavelength of 450nm. The measurement should be conducted within 15 minutes after adding the termination solution.Calculation:Draw a standard curve on a coordinate paper with the concentration of the standard substance as the x-axis and the OD value as the y-axis. Based on the OD value of the sample, determine the corresponding concentration from the standard curve; Multiply it by the dilution factor; Alternatively, a linear regression equation can be used to calculate the standard curve using the concentration and OD value of the standard substance. The OD value of the sample can be substituted into the equation to calculate the sample concentration, which is then multiplied by the dilution factor to obtain the actual concentration of the sample.Notes:1. The kit should be balanced at room temperature for 15-30 minutes before use when taken out from the cold storage environment. If the enzyme coated plate is not used up after opening, the Flat noodles should be stored in a sealed bag.2. Concentrated detergent may precipitate crystals. When diluted, it can be heated in a water bath to aid in dissolution. Washing does not affect the results.3. A sampler should be used for each step of sample addition, and its accuracy should be regularly calibrated to avoid experimental errors. It is best to control the sample addition time within 5 minutes. If there are a large number of specimens, it is recommended to use a firing gun for sample addition.4. Please make a standard curve at the same time as each measurement, preferably with a re hole. If the content of the substance to be tested in the sample is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute the sample diluent by a certain multiple (n times) before measurement. When calculating, please multiply the total dilution multiple (x n x 5).5. The sealing film is only for one-time use to avoid cross contamination.6. Please store the substrate in dark.7. Strictly follow the instructions and determine the test results based on the reading of the enzyme-linked immunosorbent assay (ELISA) reader8. All samples, washing liquids, and various waste should be treated as infectious substances.9. The components of this reagent with different batch numbers shall not be mixed.Detection range:two µ G/L-90 µ G/L... Read More |