| Description | This product is a cDNA first strand synthesis kit specially prepared for the first step experiment of two-step RT-PCR. This product contains all the reagents required for reverse transcription from RNA templates to cDNA first strand, including HiFi MMLV reverse transcriptase, reaction buffer, This product is a cDNA first strand synthesis kit specially prepared for the first step experiment of two-step RT-PCR. This product contains all the reagents required for reverse transcription from RNA templates to cDNA first strand, including HiFi MMLV reverse transcriptase, reaction buffer, primers, dNTP, etc. The mutated HiFi MMLV reverse transcriptase RNase H activity is deficient, reducing RNA degradation in reverse transcription reactions and making it easier to obtain full-length cDNA. HiFi MMLV reverse transcriptase has strong thermal stability and can yield high yields of cDNA, making it simple and convenient to use. This system has high compatibility with subsequent PCR and quantitative PCR experiments, and is suitable for various DNA polymerase reactions. H665693 Component 100 T Storage H665693A HiFi-MMLV, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665693B 5×RT Buffer 500 µL -20℃. Avoid freeze/thaw cycle. H665693C Primer Mix 240 µL -20℃. Avoid freeze/thaw cycle. H665693D dNTP Mix, 2.5 mM Each 500 µL -20℃. Avoid freeze/thaw cycle. H665693E DTT, 0.1 M 240 µL -20℃. Avoid freeze/thaw cycle. H665693F RNase-Free Water 1 mL -20℃. Avoid freeze/thaw cycle. Product features:·RNase H -: Mutated HiFi MMLv reverse transcriptase with reduced RNase H activity, making it easier to obtain full-length cDNA.·Easy to use: The reagent kit contains all the reagents required for reverse transcription, except for RNA templates.Notes:1. During the operation process, RNase contamination should be avoided to prevent RNA degradation or cross contamination during experiments. It is recommended to perform RNA operations in specialized areas, use specialized instruments and consumables, and have operators wear masks and disposable gloves, and frequently change gloves.2. Disposable plastic containers should be used as much as possible for experiments. If glass containers are used, they should be treated with a 0.1% DEPC (diethyl pyrocarbonate) aqueous solution at 37 ℃ for 12 hours, and sterilized under high pressure at 120 ℃ for 30 minutes before use. Alternatively, glass containers should be sterilized under dry heat at 180 ℃ for 60 minutes before use. The sterile water used in the experiment should be treated with 0.1% DEPC and then subjected to high-pressure sterilization.3. All reagents in this reagent kit should be gently mixed upside down before use, avoiding foaming as much as possible, and used after brief centrifugation. The enzymes involved should be returned to -20 ℃ as soon as possible after use to avoid repeated freeze-thaw cycles.If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.Usage:Attention: 10 ng-5 µ G Total RNA can establish 20 µ Reaction system, if the total RNA content is greater than 5 µ g. Please expand the reaction system proportionallyi Steps for reverse transcription:1. Dissolve RNA templates, primers, dNTP Mix, DTT, RT Buffer, HiFi MMLV, and RNase Free Water and place on ice for later use.2. Prepare a reaction system according to the following table, with a total volume of 20 µ L. Reagent 20 µlReaction system Final concentration dNTP Mix,2.5 mM Each 4 µl 500 µM Each Primer Mix 2 µl / RNA Template X µl 1 ng-5 µg 5×RT Buffer 4 µl 1× DTT,0.1 M 2 µl 10 mM HiFi-MMLV,200 U/µl 1 µl / RNase-Free Water up to 20 µl / Attention:1) If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.2) Primer Mix is formulated from Oligo (dT) and Random Primer3. Vortex shake and mix well, briefly centrifuge to collect the solution on the pipe wall to the bottom of the pipe. 4. Incubate at 42 ℃ for 30-50 minutes and 85 ℃ for 5 minutes. After the reaction is complete, centrifuge briefly and cool on ice.5. Reverse transcripts can be directly used for PCR reactions and fluorescence quantitative PCR reactions, or stored at -20 ℃ for a long time.ii If the reverse transcription efficiency is low, or the RNA template secondary structure is complex and the GC content is high, the following steps are recommended:1. Dissolve RNA templates, primers, dNTP Mix, DTT, RT Buffer, HiFi MMLV, and RNase Free Water and place on ice for later use.2. Prepare the reaction system according to the following table, with a total volume of 13 µ L. Reagent 20 µlReaction system Final concentration dNTP Mix,2.5 mM Each 4 µl 500 µM Each Primer Mix 2 µl / RNA Template X µl 1 ng-5 µg RNase-Free Water up to 13 µl / 3. Incubate at 70 ℃ for 10 minutes and quickly ice bath for 2 minutes.4. Centrifuge briefly to collect the solution on the tube wall to the bottom of the tube.5. Continue to add the following reagents to the above reaction solution: Reagent 20 µlReaction system Final concentration 5×RT Buffer 4 µl 1× DTT,0.1 M 2 µl 10 mM HiFi-MMLV,200 U/µl 1 µl / Attention:1) If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.2) Primer Mix is formulated from Oligo (dT) and Random primer.6. Gently blow and mix well, incubate at 42 ℃ for 50 minutes, and incubate at 85 ℃ for 5 minutes.7. After the reaction is complete, centrifuge briefly and cool on ice.8. Reverse transcripts can be directly used for PCR reactions and fluorescence quantitative PCR reactions, or stored at -20 ℃ for a long time... Read More | Product content:ComponentG665836100 rxnsG665836100 rxnsG665836100 rxns2×GoldStar Probe One Step Buffer1.4 ml1.4 ml1.4 mlGoldStar Probe One Step EnzymeMix100 µl100 µl100 µl50×Low ROX-50 µl-50×High ROX--50 µlRNase-Free Water1.5 ml1.5 ml1.5 mlProduct IntroductionProduct content:ComponentG665836100 rxnsG665836100 rxnsG665836100 rxns2×GoldStar Probe One Step Buffer1.4 ml1.4 ml1.4 mlGoldStar Probe One Step EnzymeMix100 µl100 µl100 µl50×Low ROX-50 µl-50×High ROX--50 µlRNase-Free Water1.5 ml1.5 ml1.5 mlProduct Introduction:This product is a specialized reagent kit for one-step Real Time RTqPCR using probe methods (TaqMan, Molecular Beacon, etc.). When using this product for Real Time RT qPCR reaction, reverse transcription and quantitative PCR are requiredConducted in the same reaction system, there is no need to add reagents or open the tube cap during the reaction process, avoiding contaminationThis has improved the efficiency of the experiment. This product has high detection sensitivity, strong fluorescence signal, and high signal-to-noise ratio, making it very suitable forDetection of RNA viruses and other trace amounts of RNA. The special buffering system it contains can enable reverse transcriptase to interact with DNA polymeraseMaximize the effectiveness and improve reaction efficiency. By using this product, a wider linear range can be obtained, which is beneficial for the target base Due to more accurate quantification, good repeatability, and high reliability.ROX dye is used to correct the fluorescence signal error generated between wells in quantitative PCR instruments, and is generally used for ABIReal Time PCR amplification equipment from companies such as Stratagene. The excitation optical systems of different instruments vary, thereforeThe concentration of ROX dye must be matched with the corresponding fluorescence quantitative PCR instrument.matters needing attention:1. Before using the reagents in this reagent kit, please gently mix them upside down to avoid foaming as much as possible, and use them after brief centrifugation. 2. This product uses RNA as a template for one-step RT-PCR experiments, and RNase contamination should be avoided during the operation process,2.It is recommended to perform RNA operations in a dedicated area, using specialized instruments and consumables. Operators should wear masks and disposable gloves and frequently change gloves. Experimental consumables should be treated with a 0.1% DEPC (diethyl pyrocarbonate) aqueous solution at 37 ℃ for 12 hours and sterilized under high pressure for 30 minutes before use.3. Each reagent in this kit should avoid repeated freezing and thawing as much as possible, as repeated freezing and thawing may lead to a decrease in product performance.4. This reagent kit must use specific primers, and the selection of primers can be based on specific experiments. The quality of primer design directly affects the results of RT qPCR reaction. When designing primers, GC content, primer length, and primer should be considered Due to factors such as location, secondary structure of PCR products, it is recommended to use professional primer design software for design.5. It is recommended to use specific probes in this reagent kit and use professional design software for design. Usage: The following examples are typical reaction systems and conditions. In practical operation, corresponding improvements and optimizations should be made based on the differences in template, primer structure, and target fragment size. (Please prepare the reaction solution on ice)1. Dissolve the RNA template, primers, 2xGoldStar Probe One Step Buffer, GoldStar Probe One Step EnzymeMix, and RNase Free Water and place them on ice for later use.2. PCR reaction system: reagent 25 µl Reaction system final concentration 2×GoldStar Probe One Step Buffer 12.5 µl 1× Forward Primer,10 µM 0.5 µl 0.2 µM 1) Reverse Primer,10 µM 0.5 µl 0.2 µM 1) Probe ,10 µM 0.5 µl 0.2 µM 2) GoldStar Probe One Step EnzymeMix 1.0 µl / RNA Template X µl 10 pg – 100 ng3) 50×Low ROX or High ROX (optional)4) 0.5 µl 1× RNase-Free Water up to 25 µl /Note: 1) Typically, the primer concentration is 0.2 µ M can achieve good results, ranging from 0.1 to 1.0 µ M serves as a reference for setting the range. 2) The concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance. Please refer to the instrument manual or the specific usage requirements of each fluorescent probe for concentration adjustment during actual use.3) The amount of RNA templates is usually based on 10 pg-100 ng as a reference. Due to the different copy numbers of target genes contained in templates of different species, gradient dilution can be applied to the templates to determine the optimal template usage.4) The excitation optical systems of different instruments vary, and depending on the instrument used for fluorescence quantification, 50 x Low ROX or 50 x High ROX can be added.3. Mix well, centrifuge briefly, and collect the solution to the bottom of the tube.4. RT-PCR reaction conditions steps temperature time / Reverse Transcription 45℃ 10 min / PCR pre denaturation 95℃ 10 min / denaturation 95℃ 15s 30-40cycle Annealing/Extension 60℃ 45s 30-40cycleAttention:1) The hot start enzyme used in this product must be activated under pre denaturation conditions of 95 ℃ and 5-10 minutes.2) It is recommended to use a two-step PCR reaction program. If good experimental results cannot be obtained due to the use of primers with lower Tm values, a three-step PCR amplification can be attempted. The annealing temperature should be set within the range of 56 ℃ -64 ℃ as a reference... Read More | Apoptosis refers to the cell autonomous and orderly death controlled by genes to maintain the stability of the internal environment. Apoptosis is different from cell necrosis. Apoptosis generally refers to a programmed cell death process that occurs during the development of body cells or under the Apoptosis refers to the cell autonomous and orderly death controlled by genes to maintain the stability of the internal environment. Apoptosis is different from cell necrosis. Apoptosis generally refers to a programmed cell death process that occurs during the development of body cells or under the action of some factors through the regulation of intracellular genes and their products. Cell necrosis is a cell death process that is caused by strong physical and chemical or biological factors to cause disordered changes in cells. The difference between apoptosis and necrosis lies in the characteristic morphological and biochemical changes, including the changes of cell membrane permeability and nuclear chromatin, the contraction of cytoplasm and the loss of membrane asymmetry. The oxazole yellow/pi membrane permeability apoptosis detection kit produced by our company is a dual fluorescence detection kit based on oxazole yellow and PI dyes. This kit is suitable for fluorescence microscopy, flow cytometry, fluorescence microplate reader and other fluorescence detection systems. Oxazole yellow is a non cell membrane penetrating cyanine monomer green fluorescent dye with high affinity for DNA. It basically has no fluorescence when it is not bound to DNA, but can emit bright green fluorescence after binding to DNA. When apoptosis occurs, the permeability of cell membrane changes. At this time, oxazole yellow can enter the cell and bind to DNA, emitting bright green fluorescence. Therefore, it is often used for the detection of apoptosis. It should be noted that oxazole yellow can also stain dead cells, so it needs to be double stained with PI that specifically fluorescently stains dead cells to effectively determine apoptosis. PI (propidium iodide) is a red fluorescent dye that can stain DNA. It is an analog of pyridine bromide that releases red fluorescence after embedding double stranded DNA. Although PI cannot pass through the membrane of living cells, it can cross the damaged cell membrane of dead cells to stain nuclei. Therefore, oxazole yellow combined with PI can be directly used for the detection of apoptosis. Apoptotic cells show green fluorescence, dead cells show both red and green fluorescence positive, and living cells have little or no fluorescence.Components: Components O598364-50T A. Oxazole yellow dye 50 µL B. Propidium Iodide (PI) 50 µLUsage (using flow cytometry as an example):1. Cell preparation(1) For adherent cells, after trypsin digestion, resuspend in culture medium and wash once with pre cooled PBS; The digestion time of trypsin should not be too long to prevent false positives. Note: Digest with trypsin and allow the cells to recover in the optimal cell culture conditions and medium for about 30 minutes, then stain.(2) For suspended cells, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and wash once with pre cooled PBS.2. Cell stainingSuspend cells in pre cooled PBS, with a recommended cell count of 106 cells/mL per sample. Add 1 µ L Oxazole Yellow and 1 µ L to 1 mL of the samplePI, Gently blow and mix well. Incubate on ice in the dark for 30 minutes. Note: We suggest adding the following two experimental controls:Blank tube: negative control group cells, without dye, used to regulate voltage.Single staining tube: Positive control group cells were treated with only two tubes, Oxazole yellow and PI, for regulating compensation.3. Flow detectionAfter incubation, the sample can be directly detected by flow cytometry, or centrifuged at 1000 rpm for 5 minutes, the supernatant can be aspirated, and the sample can be resuspended in 1 mL of pre cooled PBS for flow cytometry detection. Oxazole yellow can be excited by a 488 nm laser, and the detected fluorescence emission spectrum is around 530 ± 30 nm (FITC channel), while the PI channel emission spectrum is around 617 nm (PI or PE channel).Product parameters:Oxazole yellow dye:ex/em = 491 / 509 nm (bound DNA); Propidium iodine:ex/em = 535 / 617 nm (combined with DMatters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. fluorescent dyes have quenching problems. Please try to avoid light to slow down fluorescence quenching. 3. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Membrane permeability apoptosis assay... Read More | DescriptionPhoto KitAlysis Starter Kit enables screening of 24 micro-scale simultaneous photocatalytic reactions with consistent and reproducible photon intensity. User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsComponents:Photo KitAlysis LED ControllerBlue LED DescriptionPhoto KitAlysis Starter Kit enables screening of 24 micro-scale simultaneous photocatalytic reactions with consistent and reproducible photon intensity. User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsComponents:Photo KitAlysis LED ControllerBlue LED Array (470 nm)Photo KitAlysis Reaction BlockTorque screwdriverSmall screwdriver to easily remove torqued screws after reaction is completeFeatures:Designed and tested by synthetic chemists.Controller provides repeatable milliamp selection for photon intensity0-30 mA variable LED output3 different LED options: blue (470 nm, included), green (527 nm, sold separately), and white (sold separately)Non-magnetic LED baseChemically resistant LED coverPTFE coated cablingDesigned to be used withPhoto KitAlysis High-Throughput Reaction Screening Kit(sold separately).Best when used withKitAlysis Benchtop Inertion Box(sold separately)... Read More | Product contentP666142Component200 TStorageP666142ABuffer P160 mLRTP666142BBuffer P260 mLRTP666142CBuffer N380 mLRTP666142DBuffer PB35 mLRTP666142EBuffer PW (concentrate)25 mLRTP666142FBuffer EB30 mLRTP666142GRNase A (10 mg/mL)600 µLRTP666142HSpin Columns DM with Collection Tubes200 EART Product contentP666142Component200 TStorageP666142ABuffer P160 mLRTP666142BBuffer P260 mLRTP666142CBuffer N380 mLRTP666142DBuffer PB35 mLRTP666142EBuffer PW (concentrate)25 mLRTP666142FBuffer EB30 mLRTP666142GRNase A (10 mg/mL)600 µLRTP666142HSpin Columns DM with Collection Tubes200 EART Product IntroductionThis kit is suitable for extracting 1-5 ml of bacterial solution. Based on the lysis of cells by alkaline lysis method, it adopts a unique silica matrix membrane adsorption technology and reagent formulation, and efficiently and exclusively binds plasmid DNA in solution by centrifugal adsorption columns in a high-salt state, and each adsorption column can adsorb a maximum of 30 µg of plasmid DNA, and removes proteins, genomes, RNAs, and other impurities to the greatest extent possible. The plasmid DNA obtained can be directly used for cell transfection, PCR, digestion, sequencing, ligation and other biological experiments.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. All components can be stably stored in dry, room temperature (15-30℃) environment for 1 year, the adsorption column can be stored at 2-8℃ for a longer period of time, and Buffer P1 with RNase A can be stably stored at 2-8℃ for 6 months.2. Before the first use, add all the RNase A solution into Buffer P1, mix well, and store it at 2-8°C. Before use, leave it at room temperature for a period of time, and then use it after recovering to room temperature.3. Anhydrous ethanol should be added to Buffer PW according to the instructions on the label of the reagent bottle before first use.4. If precipitation is found in Buffer P2, Buffer N3, or Buffer PB before use, the clarification can be restored by water bath at 37℃ for a few minutes (please do not shake Buffer P2 violently).5. Be careful not to touch Buffer P2, Buffer N3 and Buffer PB directly, and tighten the lid immediately after use.6. The amount and purity of extracted plasmid is related to the concentration of bacterial culture, strain type, plasmid size, plasmid copy number and other factors.Procedure1. Take 1-5 ml of the overnight culture and add it to a centrifuge tube (self-prepared), centrifuge for 30 seconds at 13,000 rpm (~16,200×g) to collect the bacterial precipitate, and discard the supernatant as much as possible.2. Add 250 µl of Buffer P1 to the centrifuge tube with the bacterial precipitate (please check that RNase A has been added first), mix well using a pipette or vortex shaker, and suspend the bacterial precipitate.Note: If the bacterial mass is not thoroughly mixed, it will affect the lysis effect, resulting in low extraction and purity.3. Add 250µl of Buffer P2 to the centrifuge tube and mix gently up and down 4-6 times, mixing well to lyse the organisms, at which point the solution should become clear and viscous.Note: Mix gently, do not shake vigorously to avoid interrupting the genomic DNA and causing the extracted plasmid to be mixed with genomic DNA fragments. This step should take no more than 5 minutes to avoid damage to the plasmid.4. Add 350 µl of Buffer N3 to the centrifuge tube and immediately mix gently up and down for 8-10 times, mixing well so that a white flocculent precipitate should appear. centrifuge at 13,000 rpm for 5 minutes.Note: Buffer N3 should be mixed immediately after addition to avoid localized precipitation.5. Transfer the supernatant obtained in step 4 to the Spin Columns DM that have been loaded into the collection tube, centrifuge at 13,000 rpm for 30 seconds, pour off the waste liquid from the collection tube, and place the column back into the collection tube.6. Add 150 µl Buffer PB to the adsorption column and centrifuge at 13,000 rpm for 30 seconds.7. Add 400 µl Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first), centrifuge at 13,000 rpm for 1 minute, and pour off the waste liquid in the collection tube.8. Place the adsorbent column in a new centrifuge tube (supplied), add 50-100 µl Buffer EB to the middle of the adsorbent membrane, leave it at room temperature for 2 minutes, centrifuge at 13,000 rpm for 1 minute, and collect the plasmid solution into the centrifuge tube. -The plasmid solution was collected into the centrifuge tube.Note: 1) To increase the recovery efficiency of the plasmid, the resulting solution can be reintroduced into the adsorbent column, left at room temperature for 2 minutes, centrifuged at 13,000 rpm for 1 minute, and the plasmid solution collected into a centrifuge tube.2) For low plasmid copy number or >10 kb, Buffer EB is preheated at 65-70°C in a water bath to increase extraction efficiency... Read More |