| Description | This product is a cDNA first strand synthesis kit specially prepared for the first step experiment of two-step RT-PCR. This product contains all the reagents required for reverse transcription from RNA templates to cDNA first strand, including HiFi MMLV reverse transcriptase, reaction buffer, This product is a cDNA first strand synthesis kit specially prepared for the first step experiment of two-step RT-PCR. This product contains all the reagents required for reverse transcription from RNA templates to cDNA first strand, including HiFi MMLV reverse transcriptase, reaction buffer, primers, dNTP, etc. The mutated HiFi MMLV reverse transcriptase RNase H activity is deficient, reducing RNA degradation in reverse transcription reactions and making it easier to obtain full-length cDNA. HiFi MMLV reverse transcriptase has strong thermal stability and can yield high yields of cDNA, making it simple and convenient to use. This system has high compatibility with subsequent PCR and quantitative PCR experiments, and is suitable for various DNA polymerase reactions. H665693 Component 100 T Storage H665693A HiFi-MMLV, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665693B 5×RT Buffer 500 µL -20℃. Avoid freeze/thaw cycle. H665693C Primer Mix 240 µL -20℃. Avoid freeze/thaw cycle. H665693D dNTP Mix, 2.5 mM Each 500 µL -20℃. Avoid freeze/thaw cycle. H665693E DTT, 0.1 M 240 µL -20℃. Avoid freeze/thaw cycle. H665693F RNase-Free Water 1 mL -20℃. Avoid freeze/thaw cycle. Product features:·RNase H -: Mutated HiFi MMLv reverse transcriptase with reduced RNase H activity, making it easier to obtain full-length cDNA.·Easy to use: The reagent kit contains all the reagents required for reverse transcription, except for RNA templates.Notes:1. During the operation process, RNase contamination should be avoided to prevent RNA degradation or cross contamination during experiments. It is recommended to perform RNA operations in specialized areas, use specialized instruments and consumables, and have operators wear masks and disposable gloves, and frequently change gloves.2. Disposable plastic containers should be used as much as possible for experiments. If glass containers are used, they should be treated with a 0.1% DEPC (diethyl pyrocarbonate) aqueous solution at 37 ℃ for 12 hours, and sterilized under high pressure at 120 ℃ for 30 minutes before use. Alternatively, glass containers should be sterilized under dry heat at 180 ℃ for 60 minutes before use. The sterile water used in the experiment should be treated with 0.1% DEPC and then subjected to high-pressure sterilization.3. All reagents in this reagent kit should be gently mixed upside down before use, avoiding foaming as much as possible, and used after brief centrifugation. The enzymes involved should be returned to -20 ℃ as soon as possible after use to avoid repeated freeze-thaw cycles.If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.Usage:Attention: 10 ng-5 µ G Total RNA can establish 20 µ Reaction system, if the total RNA content is greater than 5 µ g. Please expand the reaction system proportionallyi Steps for reverse transcription:1. Dissolve RNA templates, primers, dNTP Mix, DTT, RT Buffer, HiFi MMLV, and RNase Free Water and place on ice for later use.2. Prepare a reaction system according to the following table, with a total volume of 20 µ L. Reagent 20 µlReaction system Final concentration dNTP Mix,2.5 mM Each 4 µl 500 µM Each Primer Mix 2 µl / RNA Template X µl 1 ng-5 µg 5×RT Buffer 4 µl 1× DTT,0.1 M 2 µl 10 mM HiFi-MMLV,200 U/µl 1 µl / RNase-Free Water up to 20 µl / Attention:1) If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.2) Primer Mix is formulated from Oligo (dT) and Random Primer3. Vortex shake and mix well, briefly centrifuge to collect the solution on the pipe wall to the bottom of the pipe. 4. Incubate at 42 ℃ for 30-50 minutes and 85 ℃ for 5 minutes. After the reaction is complete, centrifuge briefly and cool on ice.5. Reverse transcripts can be directly used for PCR reactions and fluorescence quantitative PCR reactions, or stored at -20 ℃ for a long time.ii If the reverse transcription efficiency is low, or the RNA template secondary structure is complex and the GC content is high, the following steps are recommended:1. Dissolve RNA templates, primers, dNTP Mix, DTT, RT Buffer, HiFi MMLV, and RNase Free Water and place on ice for later use.2. Prepare the reaction system according to the following table, with a total volume of 13 µ L. Reagent 20 µlReaction system Final concentration dNTP Mix,2.5 mM Each 4 µl 500 µM Each Primer Mix 2 µl / RNA Template X µl 1 ng-5 µg RNase-Free Water up to 13 µl / 3. Incubate at 70 ℃ for 10 minutes and quickly ice bath for 2 minutes.4. Centrifuge briefly to collect the solution on the tube wall to the bottom of the tube.5. Continue to add the following reagents to the above reaction solution: Reagent 20 µlReaction system Final concentration 5×RT Buffer 4 µl 1× DTT,0.1 M 2 µl 10 mM HiFi-MMLV,200 U/µl 1 µl / Attention:1) If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.2) Primer Mix is formulated from Oligo (dT) and Random primer.6. Gently blow and mix well, incubate at 42 ℃ for 50 minutes, and incubate at 85 ℃ for 5 minutes.7. After the reaction is complete, centrifuge briefly and cool on ice.8. Reverse transcripts can be directly used for PCR reactions and fluorescence quantitative PCR reactions, or stored at -20 ℃ for a long time... Read More | Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the experiment within 2 h of sampling. The longer the sample is stored, the worse the cell separation effect is. The separation effect is even worse after the sample is placed for more than 6 h, or even cannot achieve the purpose of separation. 2. in this experiment, it is better not to use plastic products with high polymerization materials (such as polystyrene), but use non-static, low static ionization heart tubes and glass products without alkali treatment, because the electrostatic effect will lead to cell adhesion, and the surface of alkali treated glass will become rough, which will affect the effect of cell separation. 3. aspirating too many lymphocyte layers and separation liquid layers will cause the granulocytes at the junction of separation liquid to be aspirated, thus increasing the number of mixed granulocytes. 4. when the amount of separating solution is greater than that of tissue single cell suspension sample, the separation effect is better.Scope of application:Lymphocyte isolation... Read More | Hydrogen peroxide, a reactive oxygen species produced through the metabolism of molecular oxygen, serves as both an intracellular signaling messenger and a source of oxidative stress. Hydrogen peroxide is generated in cells via multiple mechanisms such as the NOX-mediated ROS production by Hydrogen peroxide, a reactive oxygen species produced through the metabolism of molecular oxygen, serves as both an intracellular signaling messenger and a source of oxidative stress. Hydrogen peroxide is generated in cells via multiple mechanisms such as the NOX-mediated ROS production by neutrophils and macrophages (respiratory burst) or by the dismutase of superoxide anions produced as a result of electron leak during mitochondrial respiration. Abnormal hydrogen peroxide production contributes to oxidative cell damage and the progression of diseases such as asthma, atherosclerosis, osteoporosis, and neurodegeneration.Intracellular hydrogen peroxide assay kit has been used to measure intracellular hydrogen peroxide levels... Read More | Product introduction:This kit uses an improved SDS alkaline lysis method combined with DNA preparation membrane to selectively adsorb DNA to achieve the purpose of rapid purification of plasmid DNA. It is suitable for extracting up to 100u of high-purity plasmid DNA from 30-100 ml of Product introduction:This kit uses an improved SDS alkaline lysis method combined with DNA preparation membrane to selectively adsorb DNA to achieve the purpose of rapid purification of plasmid DNA. It is suitable for extracting up to 100u of high-purity plasmid DNA from 30-100 ml of bacterial culture for sequencing, in vitro transcription and translation, restriction enzyme digestion, bacterial transformation and other molecular biology experiments.Scope of application:Nucleic acid extraction and purification... Read More | Inquire |