| Description | Store at -20°C. Please refer to protocols | D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H Buffer EB 4 mL RT D665729I Buffer PS 10 mL RT D665729J Spin Columns DF 50 Pcs 2-8 ℃ D665729K Collection Tubes 50 Pcs RTProduct Introduction:The basic principle of this reagent kit is that after DNA is treated with sodium bisulfite, unmethylated cytosine can be transformed into uracil, while methylated cytosine remains unchanged. And adopting an innovative high-temperature treatment method, the transformation time is greatly shortened, the transformation efficiency is improved, and the transformation efficiency can reach over 99%. At the same time, using a silicon-based membrane purification column, DNA can be recovered and purified from the methylated solution through a simple binding washing elution step. The recovered DNA has high purity and good integrity, and can be directly used for sequencing, methylated PCR detection, chip analysis, connection and transformation, enzyme digestion, labeling, microinjection, PCR and in vitro transcription and other molecular biology experiments.Self prepared reagents: anhydrous ethanol, 75% ethanol.Preparation and important precautions before the experiment1. Product usage method:(1) 10 times packaging preparation method: CT Conversion Agent is a solid mixture that must be prepared before first use. Add 2 ml sterile water and 100 µ M-Dissolving Buffer and 300 µ Add M-Diffusion Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 10 DNA treatments. In order to achieve better results, the prepared CT Conversion Agent should be used immediately. If not used immediately, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.(2) 50 times packaging preparation method: CT Conversion Agent and M-Dissolving Buffer are solid mixtures that must be prepared before first use. Add 5 ml of sterile water to the M-Dissolving Buffer and shake to dissolve. After all the solids have dissolved, transfer all the solution from the M-Dissolving Buffer tube to the CT Conversion Agent tube and add 5.5 ml of sterile water. Add 1.5 ml of M-Dilution Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 50 DNA treatments. In order to achieve better results, the CT Conversion Agent should be used immediately after preparation. If not immediately used, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.2. Before the first use, anhydrous ethanol should be added to the M-Wash Buffer according to the instructions on the reagent bottle label.Operation stepsThe range of DNA prepared each time is 1 ng-4 µ Between g, the optimal amount is 500 ng-2 µ G.1. Take 20 µ Add DNA sample into centrifuge tube (self provided), and if the sample amount is insufficient, replenish with water up to 20 µ L.2. Add 2.2 to the DNA sample µ Mix the sample well with the M-Dilution Buffer of l.3.42 ℃ water bath for 30 minutes.4. Add 220 to the sample obtained from the previous step µ Prepare the CT Conversion Agent solution, mix well, and incubate in an 80 ℃ constant temperature water bath in a dark place for 60 minutes.5. Add 480 to the solution in the previous step µ M - Buffer PA, gently mix upside down.6. Column balance: Add 200 to the spin columns DS that have been loaded into the collection tube µ Centrifuge at 12000 rpm (~13400 × g) for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7.Add all the solution obtained from step 5 to the adsorption column (already loaded into the collection tube), let it stand at room temperature for 2 minutes, centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Attention: The maximum capacity of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.8. Add 500 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute using M-Buffer PA, discard the waste liquid from the collection tube, and place the adsorption column in the recovery tube.9. Add 650 to the adsorption column µ M-Wash Buffer (please check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.10.12000 rpm for 2 minutes, discard the waste liquid, and place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column into a new centrifuge tube (provided by oneself), and add 20 drops to the middle position of the adsorption membrane in the air µ M-Elution Buffer (pH 8.5), leave at room temperature for 2 minutes. Collect DNA solution by centrifugation at 12000 rpm for 1 minute.12. Collect 20 µ Add 2.2 to DNA µ M-Diffusion Buffer, let it stand at room temperature for 30 minutes.13. Add 500 to the solution µ After pre cooling anhydrous ethanol, invert and mix well, and place the solution at -20 ℃ to precipitate for 30 minutes (overnight precipitation is more effective).14.12000 rpm for 15 minutes and gently discard the supernatant.15. Add 75% ethanol, centrifuge at 12000 rpm for 1 minute, pour out the supernatant, wait for ethanol to evaporate at room temperature, then add 20 µ Dissolve the M-Elution buffer and store the DNA at -20 ℃. The DNA collected in this step can be used for subsequent related experiments... Read More | Product content: G665990Component200 TStorageG665990ABuffer PG100 mLRTG665990BBuffer PS60 mLRTG665990CBuffer PW (concentrate)50 mLRTG665990DBuffer EB30 mLRTG665990ESpin Columns DM with Collection Tubes200 EART Product Introduction:This kit uses a new silicon-based plasma membrane technology and Product content: G665990Component200 TStorageG665990ABuffer PG100 mLRTG665990BBuffer PS60 mLRTG665990CBuffer PW (concentrate)50 mLRTG665990DBuffer EB30 mLRTG665990ESpin Columns DM with Collection Tubes200 EART Product Introduction:This kit uses a new silicon-based plasma membrane technology and reagent formulation. Through the unique centrifugal adsorption column and the DNA washing elution step, 100 bp-10 kb DNA fragments can be recovered and purified from ordinary or low melting point agarose gel. The sol speed is fast and the recovery rate is high. The sol solution contains a pH indicator, which can be used to determine whether the sol recovery has reached the optimal state based on its color. Each adsorption column can adsorb up to 10 µ G DNA, while effectively removing impurities such as primers, enzymes, mineral oil, and agarose. The purified and recovered DNA has high purity and concentration, good integrity, and can be directly used for molecular biology experiments such as sequencing, linking and transformation, labeling, and in vitro transcription.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.2. Before use, please check the Buffer PG. If crystallization or precipitation occurs, it can be left in a 37 ℃ water bath for 3-5 minutes to restore clarity.3. It is best to use a new electrophoresis buffer during electrophoresis to avoid affecting the electrophoresis and recovery efficiency; The following experiment requires high requirements, please use TAE electrophoresis buffer as much as possible.4.When cutting glue, the UV irradiation time should be as short as possible to avoid damage to DNA.5. The recovery rate is related to the initial amount of DNA and the elution volume. The smaller the initial amount, the smaller the elution volume, and the lower the recovery rate.6. Preheat the water bath to 50 ℃.7. Buffer PG contains a pH indicator. When the pH is ≤ 7.5, the color of the solution is yellow, and DNA can effectively bind to the membrane. When the pH is too high, the color of the solution turns orange red and purple, which needs to be adjusted.8. All centrifugation steps can be performed at room temperature.Operation steps:1. Cut the single purpose DNA strip from the agarose gel (try to cut the excess), put it into a clean centrifuge tube (self prepared), and weigh and calculate the weight of the gel (record the weight of the centrifuge tube in advance).Attention: If the volume of the adhesive block is too large, it can be cut into small pieces.2. Add one time of the volume of Buffer PG (if the gel weighs 100 mg, its volume can be regarded as 100 µ l. And so on.3.50 ℃ water bath and gently invert the centrifuge tube every 2-3 minutes until the sol turns yellow to ensure full dissolution of the gel block. If there are still unsolved glue blocks, you can add some more sol solution or continue to let it stand for a few minutes until the glue blocks are completely dissolved.Note: 1) After the gel is completely dissolved, the gel solution is yellow, and subsequent operations can be carried out; If the glue solution is orange red or purple, 10-30 can be added to the glue solution µ 3 M sodium acetate (pH 5.0), adjust the color of the solution to yellow before proceeding with subsequent operations.2) After the gel block is completely dissolved, it is best to lower the temperature of the gel solution to room temperature before loading the column. The adsorption column has a weaker ability to bind DNA at higher temperatures.4. (Optional step) When the recovered fragment is less than 300 bp, add 1/2 of the gel volume of isopropanol, and mix it upside down (if the gel weighs 100 mg, add 50 µ Isopropanol of L.5. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ Centrifuge at 13000 rpm (~16200 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.6. Add the solution obtained from steps 3 or 4 to the adsorption column that has been loaded into the collection tube, let it stand at room temperature for 2 minutes, centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Attention: The volume of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.7. Add 450 to the adsorption column µ LBuffer PW (please check if anhydrous ethanol has been added before use), centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Note: If purified DNA is used for salt sensitive experiments (such as flat end ligation or direct sequencing), it is recommended to add Buffer PW and let it stand for 2-5 minutes before centrifugation.8. Repeat step 7.9.13000 rpm for 1 minute and discard the waste liquid from the collection tube.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).10. Place the adsorption column into a new 1.5 ml centrifuge tube (provided by oneself), and add 50 drops to the middle position of the adsorption membrane in the air µ L Buffer EB, leave at room temperature for 2 minutes. Centrifuge at 13000 rpm for 1 minute and collect DNA solution- Store DNA at 20 ℃.Attention:1) To improve the recovery of DNA, the solution obtained by centrifugation can be re dropped onto the adsorption column, left at room temperature for 2 minutes, and centrifuged at 13000 rpm for 1 minute.2) The elution volume should not be less than 30 µ l. A small volume will affect the recovery efficiency.3) When recovering DNA fragments larger than 10 kb, Buffer EB should be preheated in a 50 ℃ water bath to increase recovery efficiency.Note: This reagent kit is also suitable for the purification and recovery of PCR products. Add an equal volume of Buffer PG to the PCR reaction solution and mix thoroughly (for small fragments with a recovery of less than 150bp, the solution volume can be increased to three times to improve the recovery rate). Follow step 5 above for further operations... Read More | DescriptionThe Baran Late-Stage Toolkit is a convenient collection of 12 highly innovative reagents that are highly effective in the diversification of complex molecules. The contents in the box are 11 Baran Diversinates™and one vial of Palau′Chlor®in amounts of 100 mg each. For DescriptionThe Baran Late-Stage Toolkit is a convenient collection of 12 highly innovative reagents that are highly effective in the diversification of complex molecules. The contents in the box are 11 Baran Diversinates™and one vial of Palau′Chlor®in amounts of 100 mg each. For obtaining larger amounts of any desired kit component, see the kit component table at the bottom of the page.Useful Topics:Late Stage FunctionalizationBaran Group – Professor Product PortalPalau′ChlorDiversinates... Read More | This product can rapidly, gently, and efficiently lyse mammalian cells, effectively extracting cytoplasmic and nuclear proteins. This reagent uses a mild formula to ensure that the extracted protein maintains biological activity and can be applied to various protein analysis experiments, such as This product can rapidly, gently, and efficiently lyse mammalian cells, effectively extracting cytoplasmic and nuclear proteins. This reagent uses a mild formula to ensure that the extracted protein maintains biological activity and can be applied to various protein analysis experiments, such as reporter gene and enzyme activity determination, immune detection, protein purification, etc. The extracted protein can be quantitatively analyzed using the BCA method. The reagent kit contains a mixture of protease inhibitors, which can effectively prevent protein degradation during the protein extraction process.M665813Component100 TStorageM665813AMammalian Protein Extraction Reagent100 mLRTM665813BProtease Inhibitor Cocktail (100×)1 mL-20℃. Avoid freeze/thaw cycle. precautions1. This product can effectively lyse adherent cells cultured on cell culture plates (without scraping) and suspended cells collected by centrifugation, with higher extraction efficiency than repeated freeze-thaw or ultrasound methods. But for the extraction of tissue proteins, it is recommended to use the tissue protein extraction kit (CW0891).The optimal dosage for protein extraction from adherent cells is listed in Table 1. Collecting cells first can reduce the amount of reagents used to obtain higher protein concentrations.3. The amount of extraction reagents used can also be estimated based on the number of cells. If 2 × 106 Hela cells weigh about 20 mg, 200 need to be added µ Extract reagents.4. The protein extracted from this product can be quantitatively analyzed using the BCA method.Operation steps● Protein extraction from adherent cells1. Please remove the required Mammalian Protein Extraction Agent for pre cooling before protein extraction.2. Carefully pour out the culture medium of adherent cells and rinse the cells with PBS.3. Add an appropriate amount of Mammalian Protein Extraction Reagent (add Protein Inhibitor Cocktail in a 1:99 ratio 2-3 minutes before protein extraction), blow adherent cells on ice with a gun tip, transfer the lysate to a centrifuge tube, incubate on ice for 20 minutes, and allow the cells to fully lyse (please refer to Appendix 1 for the amount of reagent used, and the time for placing on ice should be adjusted according to different cell types). 4. Centrifuge at 14000 × g for 5-10 minutes.5. Transfer the supernatant to a new tube for further analysis. ● Suspension cell protein extraction1. Please remove the required Mammalian Protein Extraction Agent for pre cooling before protein extraction.2. Suspend 2500 × g of cells, centrifuge for 10 minutes, and discard the supernatant. Rinse cells with PBS. 2500 × g, centrifuge for 10 minutes, discard the supernatant.3. Add an appropriate amount of Mammalian Protein Extraction Agent, and 2-3 minutes before protein extraction, add Protein Inhibitor Cocktail in a ratio of 1:99, which is 1 x working solution.4. Add at least 1 ml of 1x working solution to every 100 mg of cells. If the extracted sample size is large, a small amount of 1x working solution can be used to resuspend the cells first, and then the remaining working solution can be added.5. After blowing evenly, place it on ice for 20 minutes to allow the cells to fully lyse (the time for placing it on ice should be adjusted according to different cell types). 6. Centrifuge at 14000 × g for 15 minutes.7. Transfer the supernatant to a new tube for further analysis.Table 1. Recommended usage of extraction reagents Cell culture plate type or dish type Extraction reagent usage 100 mm 500-1,000 µl 60 mm 250-500 µl 6-well culture plate 200-400 µl /well 24-well culture plate 100-200 µl /well 96-well culture plate 50-100 µl /well Table 2. Common Problems and Solutions Problem Possible reasons Resolvent Low extraction rate Low protein expression level Optimize transfection system Low extraction rate Insufficient reagent usage Increase the usage of extraction reagents Low extraction rate Reagent unable to dissolve cell membrane Increase cracking time or increase shaking amplitude Unable to obtain membrane protein This product is more suitable for extracting nuclear plasma protein Using eukaryotic cell membrane protein extraction kit... Read More |