| Description | Product content: M665559Component50 TStorageM665559ABuffer GTT15 mLRTM665559BBuffer GL15 mLRTM665559CBuffer GW1(concentrate)13 mLRTM665559DBuffer GW2(concentrate)15 mLRTM665559EBuffer GE15 mLRTM665559FProteinase K1.25 mLRTM665559GSpin CoLumns DM with CoLLection Tubes50 Product content: M665559Component50 TStorageM665559ABuffer GTT15 mLRTM665559BBuffer GL15 mLRTM665559CBuffer GW1(concentrate)13 mLRTM665559DBuffer GW2(concentrate)15 mLRTM665559EBuffer GE15 mLRTM665559FProteinase K1.25 mLRTM665559GSpin CoLumns DM with CoLLection Tubes50 EART Product Introduction:This reagent kit is suitable for extracting high-purity total DNA from fresh or frozen mouse or rat tails. The method provided by this reagent kit is simple and feasible, and the purification process does not require phenol or chloroform extraction. It can obtain DNA fragments up to 50 kb, and can also effectively recover fragments of 100 bp. This reagent kit uses a unique lysis solution to effectively lyse mouse tail samples. The optimized buffer system efficiently binds the DNA generated after the lysis of mouse tail to the silica matrix adsorption column, while other pollutants can flow through the membrane; Inhibitors of PCR and other enzymatic reactions can be effectively removed through a two-step washing process, followed by washing with low salt buffer or water to obtain high-purity DNA. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, ReaL Time PCR, library construction, Southern BLot, and molecular labeling.Self prepared reagent: anhydrous ethanol.Preparation and important precautions before the experiment:1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to BufferGW1 and BufferGW2 according to the instructions on the reagent bottle label.3. Before use, please check if there is any crystallization or precipitation in the Buffer GL. If there is any crystallization or precipitation, please dissolve the Buffer GL again in a 56 ℃ water bath.Operation steps:1. Take a tail of a rat or two mice with a length of 0.4-0.6 cm, grind it into fine powder in liquid nitrogen or cut it into pieces and place it in a centrifuge tube (provided by oneself). Join 180 µ L Buffer GTT, shake and mix well. Note: Ensure that the starting quantity of the organization does not exceed the recommended range.2. Add 20 µ L Protein K, vortex oscillation, thoroughly mix.3. Place in a 56 ℃ water bath until the tissue solution is completely clear. Generally, digestion is required for 6-8 hours. During the incubation process, vortex oscillation is required to evenly disperse the sample. Note: 1) If there is still gel like substance after incubation and vortex oscillation, digest overnight or add 20 more if necessary µ L Protein K digestion will not affect subsequent operations. 2) To remove RNA, add 4 after completing the above steps µ L 100 mg/mL RNase A solution, shake well and let stand at room temperature for 5-10 minutes.4.12000 rpm (~13400 × g) for 1 minute to remove undigested tissues similar to mouse hair. Transfer the supernatant to a new centrifuge tube (provided by oneself).5. Add 200 µ L Buffer GL, vortex oscillation, thoroughly mixed. Join 200 µ L anhydrous ethanol, vortex and shake, thoroughly mix. Short centrifugation allows the solution on the tube wall to be collected to the bottom of the tube.Attention: 1) After adding Buffer GL and anhydrous ethanol, immediately vortex and shake to mix well.2) If multiple samples are operated together, Buffer GL and anhydrous ethanol can be mixed in equal proportions and added to the samples together.3) The addition of Buffer GL and anhydrous ethanol may produce white precipitates, which will not affect subsequent experiments.6. Add all the solutions obtained in step 5 to the adsorption column (Spin CoLumins DM) that has been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.8. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: To further improve DNA purity, repeat step 8.9.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).10. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high.2) Incubating at room temperature for 5 minutes before centrifugation can increase yield.3) Use an additional 50-200 µ Re washing with L Buffer GE or sterilized water can increase yield.4) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 10 back onto the adsorption membrane and repeat step 10; If the elution volume is less than 200 µ L. It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ L Buffer GE or off... Read More | Inquire | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Product introduction:Griess reagent can be used for spectrophotometric detection of nitrite. The reagent contains two chemicals, sulfonic acid and n- (1-naphthyl) ethylenediamine. Under acidic conditions, sulfamic acid is converted into diazonium salt by nitrite, which can form a highly Product introduction:Griess reagent can be used for spectrophotometric detection of nitrite. The reagent contains two chemicals, sulfonic acid and n- (1-naphthyl) ethylenediamine. Under acidic conditions, sulfamic acid is converted into diazonium salt by nitrite, which can form a highly colored azo dye with n- (1-naphthyl) ethylenediamine. This dye can be detected at 548 nm: because no is extremely unstable, it is oxidized to form nitrite and nitrate. Griess indirectly reflects the content of no by detecting the content of nitrite.Matters needing attention:1. before using Griess reagent, return it to room temperature and check the solution for precipitation. If Griess reagent I contains sediment when taken out, it can be placed in a 37 ℃ water bath until the sediment dissolves. 2. this product is potentially harmful. Avoid prolonged or repeated exposure. Avoid entering eyes, skin or clothing. Please wear lab clothes and disposable gloves for operation.Scope of application:No detectionComponent:Instruction:1.Griess Reagent I and II were taken out to restore the room temperature.2.Standard dilution : The standard NaNO2 ( 1-100 µM ) was diluted with the solution used for the sample to be tested. The standard was diluted to 1 µM, 10 µM, 20 µM, 40 µM, 80 µM and 100 µM, and 100 µL standard was added to each well. If the sample concentration is too low, the range of the standard curve can be appropriately reduced ( 1 µM, 2 µM, 3 µM, 4 µM, 6 µM, 8 µM, 10 µM ).3.Sample detection :( 1 ) According to the total volume of 200 µL / hole, 100 µL / hole sample was added to the 96-well plate ; if the sample is the supernatant of the culture medium, it can be sampled directly, and if there is sediment, the supernatant should be taken after centrifugation. If the sample is a cell or tissue, it can be quickly lysed by freeze-thaw, and then centrifuged to obtain the supernatant. The volume of less than 100 µL can be diluted with diH2O or 0.9 % NaCl ( corresponding standards also need to be diluted with diH2O or 0.9 % NaCl ).( 2 ) According to 50 µL / hole, Griess Reagent I was added to each hole.( 3 ) According to 50 µL / hole, Griess Reagent II was added to each hole.( 4 ) The absorbance was measured at 540 nm. If there is no 540 nm filter, 520-560 nm filter can also be. If there is no microplate reader or a suitable filter, the concentration of nitric oxide in the sample can also be determined by visual colorimetry. A more precise concentration gradient is required for the standard when visual colorimetric... Read More | DescriptionWhite LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatableDescriptionWhite LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatable milliamp selection for photon intensity (sold seperately)0-30 mA variable LED outputNon-magnetic LED baseChemically resistant LED coverPTFE coated cablingPhoto Kitalysis Starter Kitrequired for operation (sold separately). Best when used withKitAlysis Benchtop Inertion Box(sold separately)... Read More |