| Description | Format:2-ComponentEnzyme:Horseradish peroxidase | When apoptosis occurs, some DNA endonucleases will be activated. These endonucleases will cut off genomic DNA between nucleosomes and produce 180 bp-200 BP DNA fragments, which appear as a specific ladder pattern in agarose gel electrophoresis. When double strand or single strand breaks occurWhen apoptosis occurs, some DNA endonucleases will be activated. These endonucleases will cut off genomic DNA between nucleosomes and produce 180 bp-200 BP DNA fragments, which appear as a specific ladder pattern in agarose gel electrophoresis. When double strand or single strand breaks occur in genomic DNA, a large number of sticky 3'-oh ends will be generated, which can interact with YF under the catalysis of deoxyribonucleotide terminal transferase (TDT) ®/ CY dUTP binding can directly detect apoptotic cells by fluorescence microscopy or flow cytometry. This kind of method is called terminal deoxynucleotidyl transferase mediated nick end labeling (TUNEL). Because normal or proliferating cells have almost no DNA breaks, there is no 3'-oh formation and they can rarely be stained. TUNEL method can stain intact single apoptotic nuclei or apoptotic bodies in situ, can accurately reflect the typical biochemical and morphological characteristics of apoptosis, and can detect a very small number of apoptotic cells, so it is widely used in the study of apoptosis. This kit has a wide range of applications and can be used to detect apoptosis in frozen or paraffin sections, as well as cultured adherent cells or suspended cells. It can selectively detect apoptotic cells, but not necrotic cells or cells with DNA strand breaks caused by irradiation and drug treatment. This kit detects cell apoptosis with a short time-consuming, one-step staining reaction and can be detected after washing.Component: Instruction: Experimental materials (self provided)PBS buffer (1 x, pH~7.4). 0.2% Triton X -100 (PBS formulation). 0.1% Triton X -100 (PBS formulation, containing 5 mg/mLBSA)4% paraformaldehyde (prepared with PBS)Immunohistochemical penDewaxing solvent (paraffin section sample)Related reagents for paraffin section processingAnti fluorescence quenching and sealing agent. ddH2Oexperimental design. A. Positive control:Prepare positive control slides using DNaseI treatment. DNaseI can digest single or double stranded DNA and expose the 3 '- OH end, artificially causing cell apoptosis. One experiment per time is sufficient. (To verify if there are any issues with the experimental operation and reagent kit)B. Negative control:Use TUNEL Reaction Buffer without TdT Enzyme and replace TdT Enzyme with ddH2O. (Mainly to exclude non-specific staining caused by cell apoptosis, operational processes, and other reasons; and to adjust the exposure intensity of the shooting.)C. Experimental processing group.The experimental group operated normally according to the instructions.D. Experimental control group.The experimental group operated normally according to the instructions.Experimental steps1. Sample preparation:(1) For adherent cells or cell smearsa. Clean once with PBS.Note: If you are concerned that the cells on the cell smear may not adhere firmly, you can dry the sample to make the cells adhere more firmly.b. Fixation: Add an appropriate amount of 4% paraformaldehyde (prepared with PBS) and fix at 4 ℃ for 30 minutes. Clean twice with PBS.c. Translucency: Add an appropriate amount of 0.2% Triton X -100 (prepared with PBS) and let it penetrate at room temperature for 20 minutes. Clean twice with PBS.d. Step 2: TUNEL reaction.(2) For suspended cells or cell suspensionsa. Collect cells (3-5 x 106 cells), centrifuge at 1000 rpm for 5 minutes, and wash twice with PBS.b. Fixation: Add an appropriate amount of 4% paraformaldehyde (prepared with PBS) and resuspend the cells thoroughly. Fix at 4 ℃ for 30 minutes. Centrifuge at 2000 rpm for 5 minutes and clean twice with PBS.c. Translucency: Add an appropriate amount of 0.2% Triton X -100 (prepared with PBS) and let it penetrate at room temperature for 20 minutes. Centrifuge at 2000 rpm for 5 minutes and clean twice with PBS.d. Step 2: TUNEL reaction.(3) Paraffin tissue sectioninga. Dewaxing and hydration: Place the sliced samples sequentially in xylene I (10 min) → xylene II (10 min) → 100% ethanol I (5 min) → 100% ethanol II (5 min) → 95% ethanol (5 min) → 90% ethanol (5 min) → 80% ethanol (5 min) → 70% ethanol (5 min) → ddH2O rinse for 5 min, rinse twice.Note: Xylene is toxic and volatile. Please perform this operation in a fume hood.b. Use filter paper to dry the liquid around the sliced sample, and circle the sample contour with an immunohistochemical pen for downstream transparency and labeling.Note: If it is found that the contour circle of immunohistochemistry strokes is damaged in subsequent experimental operations, it needs to be redrawn in a timely manner.c. Transparency: Dilute 2 mg/mL of ProteinaseK solution with PBS in a ratio of 1:100 to a final concentration of 20 µ g/mL. Add 100 µ L dropwise to each sample to cover all sample areas. Incubate at 20-37 ℃ for 20 minutes.Note: Protein K can penetrate the cell membrane and nuclear membrane, allowing subsequent staining reagents to fully enter the nucleus for reaction and improve labeling efficiency. An excessively long incubation time increases the risk of tissue slices falling off the carrier film during subsequent washing steps, while a too short incubation time may result in insufficient permeability treatment and affect labeling efficiency. To obtain better results, the concentration, incubation time, and temperature of Protein K need to be optimized according to different types of tissue samples.d. Wash the slices twice with PBS, each time for 5 minutes. Use filter paper to remove excess liquid, and place the processed sample in a wet box to keep it moist.Note: Protein K must be washed thoroughly in this step, otherwise it will seriously interfere with subsequent labeling reactions.e. Step 2: TUNEL reaction.(4) Frozen tissue sectionsa. Fixation: Take out frozen sections and warm them back to room temperature. Add an appropriate amount of 4% paraformaldehyde (prepared with PBS) and fix at room temperature for 30 minutes. Wash twice with PBS for 10 minutes each time.Note: If you are concerned that formaldehyde cleaning may not be clean enough, it may affect the final dyeing effect. After formaldehyde fixation is completed, an appropriate amount of 2 mg/mL glycine can be added and washed for 10 minutes to neutralize the residual fixing solution, and then PBS cleaning can be carried out.b. Use filter paper to dry the liquid around the sliced sample, and circle the sample contour with an immunohistochemical pen for downstream transparency and labeling.Note: If it is found that the contour circle of immunohistochemistry strokes is damaged in subsequent experimental operations, it needs to be redrawn in a timely manner.c. Transparency: Dilute 2 mg/mL of ProteinaseK solution with PBS in a ratio of 1:100 to a final concentration of 20 µ g/mL. Add 100 µ L dropwise to each sample to cover all sample areas. Incubate at 20-37 ℃ for 20 minutes.Note: Protein K can penetrate the cell membrane and nuclear membrane, allowing subsequent staining reagents to fully enter the nucleus for reaction and improve labeling efficiency. An excessively long incubation time increases the risk of tissue slices falling off the carrier film during subsequent washing steps, while a too short incubation time may result in insufficient permeability treatment and affect labeling efficiency. To obtain better results, the concentration, incubation time, and temperature of Protein K need to be optimized according to different types of tissue samples.d. Wash the slices twice with PBS, each time for 5 minutes. Use filter paper to remove excess liquid, and place the processed sample in a wet box to keep it moist.Note: Protein K must be washed thoroughly in this step, otherwise it will seriously interfere with subsequent labeling reactions.e. Step 2: TUNEL reaction.(5) Positive treatment (only the positive control is subjected to this step, and other samples are directly subjected to the TUNEL reaction step)a. Dilute 10 x DNase I Buffer with ddH2O in a ratio of 1:10 to 1 x DNase I Buffer for later use.b. Drip 100 µ L of 1xDNase I Buffer onto the processed sample, covering all sample areas, and equilibrate at room temperature for 5 minutes.c. Dilute DNase I (2 U) with 1 x DNase I Buffer at a ratio of 1:100/ µ L) A working solution with a final concentration of 20 U/mL.d. Discard the buffer and add 100 µ Incubate DNase I working solution with a concentration of 20 U/mL at room temperature for 10 minutes.e. Discard DNase I working solution and clean twice with PBS.f. Step 2: TUNEL reaction.2. TUNEL reaction(1) Prepare TUNEL reaction solution (ready to use):/1 sample5sample10 sampleTdT enzyme1 µL5 µL10 µLYF®488/555/594/640 TUNEL Reaction Buffer49 µL245 µL490 µLTUNEL Total volume of reaction solution50 µL250 µL500 µL(2) For adherent cells, cell smears, or tissue sectionsa. Add 50 to each sample µ L TUNEL reaction solution, evenly cover the sample with the reaction solution. The appropriate time for dark incubation at 37 ℃ (recommended staining time for cells is 30 minutes to 1 hour, and tissue staining time is 2 hours).Note: 50 µ L TUNEL reaction solution is suitable for smear, slicing, or 96 well plates (other different well plates can adjust the volume of TUNEL reaction solution appropriately to cover cells). If the sample to be tested is a smear, slice, or in a 24 well plate, 12 well plate, or 6 well plate, anti evaporation film can be used, or self sealing bags or other appropriate materials can be used to cut circular plastic sheets slightly smaller than the holes. After adding TUNEL reaction solution dropwise, cover the sample to prevent the evaporation of TUNEL reaction solution and make the TUNEL reaction solution evenly cover the sample.b. Discard the TUNEL reaction solution, wash twice with PBS, and then wash three times with 0.1% Triton X -100 (PBS preparation, containing 5 mg/mL BSA) for 5 minutes each time. This way, free unreacted markers can be removed cleanly.c. (Optional) Add an appropriate concentration of 5 to each sample µ DAPI staining solution with a concentration of g/mL, incubated at room temperature in dark for 5 minutes. After staining, discard DAPI staining solution and wash twice with PBS for 5 minutes each time.d. (Optional) Slice sealing: Add 50 drops to each sample µ L anti fluorescence quenching sealing agent (anti fluorescence quenching sealing agent may not be suitable for certain dyes, it is recommended to conduct pre experimental testing for compatibility before the experiment), cover the cover glass, gently tap the cover glass with the blunt end of tweezers to remove bubbles and ensure complete sealing.e. Use filter paper to remove excess liquid and add 100 to the sample area µ Keep the sample moist with PBS and immediately observe under a fluorescence microscope.(3) For suspended cells or cell suspensionsa. Add 50 to each sample tube µ Gently resuspend cells in LTUNEL reaction solution and incubate at 37 ℃ in the dark for 30-1 hour. Gently resuspend cells with a micropipette every 15 minutes.b. Centrifuge at 2000 rpm for 5 minutes, discard TUNEL reaction solution, and wash twice with 0.1% Triton X -100 (PBS preparation, containing 5 mg/mLBSA) for 5 minutes each time. This way, free unreacted markers can be removed cleanly.c. Add 100 to each sample tube µ L concentration is 5 µ DAPI staining solution with a concentration of g/mL, incubated at room temperature in dark for 5 minutes.d. Join 400 µ L PBS resuspended cells and immediately detected with a flow cytometer or observed under a fluorescence microscope after smearing.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. when the staining background is heavy or non-specific staining is obvious, the staining time can be appropriately reduced. 3. it is recommended to add negative control and positive control groups during the experiment. 4. please wear mask and gloves when using component A. if it contacts the skin, please wash it with plenty of water immediately. 5. fluorescent dyes have quenching problems. Please try to avoid light to slow down fluorescence quenching. 6. for your safety and health, please wear experimental clothes and disposable gloves.Product parameters:490/515 nm;Scope of application:Late apoptosis detection, TUNEL Kit... Read More | Product content N665859Component50 TStorageN665859ABuffer DS30 mLRTN665859BBuffer GTL15 mLRTN665859CBuffer GL15 mLRTN665859DBuffer GW1 (concentrate)13 mLRTN665859EBuffer GW2 (concentrate)15 mLRTN665859FBuffer TE10 mLRTN665859GProteinase K2×1.25 mLRTN665859HRNase A (100 mg/mL)0.4 Product content N665859Component50 TStorageN665859ABuffer DS30 mLRTN665859BBuffer GTL15 mLRTN665859CBuffer GL15 mLRTN665859DBuffer GW1 (concentrate)13 mLRTN665859EBuffer GW2 (concentrate)15 mLRTN665859FBuffer TE10 mLRTN665859GProteinase K2×1.25 mLRTN665859HRNase A (100 mg/mL)0.4 mLRTN665859ISpin Columns DF With Collection Tubes50 EA2-8℃N665859JCentrifuge Tubes (L-1.5 mL)50 EART Product IntroductionThis kit is suitable for the effective purification of genomic DNA from formalin-fixed, paraffin-embedded tissues.The product uses specially optimized dewaxing agent and lysis solution to release DNA from formalin-fixed or tissue sectioned samples, which does not involve the organic reagent xylene and does not need to be operated overnight; the digested samples are incubated at higher temperatures to remove formalin cross-linking of the free DNA, which can effectively improve the yield and purity of DNA; the optimized buffer system allows the inhibitors in the lysis solution to be specifically bound to the adsorbent membrane, which can be effectively removed by a two-step rinsing step. The optimized buffer system enables the DNA in the lysate to specifically bind to the adsorbent membrane, and the inhibitor is effectively removed by a two-step rinsing step, and finally eluted with low-salt buffer or water to obtain high-purity DNA.Meanwhile, configured with a high-efficiency microsorbent column, the elution volume can be as low as 20 µL.The purified DNA can be directly used for PCR, Real-time PCR, SNP Genotyping, STR genotyping, second-generation sequencing and pharmacogenomics research.The molecular weight of DNA isolated from formalin-fixed, paraffin-embedded samples is usually lower than that of DNA from fresh or frozen samples.The degree of DNA fragmentation depends on the type of sample, the duration of storage, and the conditions of fixation.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. After obtaining the sample, fix the sample in 4%-10% formalin as soon as possible, the fixation time should be 14-24 hours, too long a period of time will easily lead to genome breakage, affecting the downstream experiments. If the formaldehyde fixation time is too long or the sample has been stored for too long (> 1 year), it will easily lead to DNA integrity damage and unable to amplify long fragments.2. Ensure that the sample is thoroughly dehydrated before embedding; residual formalin will inhibit Proteinase K.3. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.4. Before use, please check Buffer GTL, Buffer GL and Buffer DS for any crystallization or precipitation. If there is any crystallization or precipitation, please re-dissolve Buffer GTL, Buffer GL and Buffer DS at 56℃ in a water bath.5. Preheat the water bath or thermostatic mixer to 56°C and keep the centrifuge at 25°C before starting the experiment.6. If downstream experiments are needed to reduce the low frequency of C>T:G>A transitions (artificial mutations) that occur to minimize the risk of false positives, 7 µL of UNG (1 U/uL) can be added after 1 hour of incubation at 90°C.Operation steps1. Sample processing:1a. Paraffin-embedded samples: Trim off excess paraffin from the tissue block with a scalpel to expose the tissue and then cut into 5-10µm slices. Take about 1×1cm2 slices (about 4-5 slices in total) and place them in a centrifuge tube (provided), add 160µL Buffer DS, vortex and shake for 10 seconds, then add 180µL Buffer GTL and 20µL Proteinase K, vortex and shake for 10 seconds. centrifuge the samples at 12,000rpm for 1 minute at 25℃.Note: 1) If the surface of the sample has been exposed to air, discard the 2-3 pieces that have been exposed to air and do not use them.2) DS will solidify below 18°C, and if it does it does not affect the following experiments.1b. Sample in formalin and other fixative: take about 20mg of sample, cut it into small pieces, place it in a centrifuge tube, add 500µL of 10mM PBS (PH7.4), vortex shaking, centrifuge at 12,000rpm for 1minute, discard the supernatant, and repeat 3 times. Add 180 µL Buffer GTL, 20 µL Proteinase K, vortex shaking to mix.2.56°C for 1 hour until the sample is completely dissolved. incubate at 90°C for 1 hour. centrifuge at 12,000 rpm, 25°C for 1 minute, and carefully pipette the lower aqueous phase (~180 µL) along the wall of the tube into a new centrifuge tube, trying to avoid aspirating the bottom precipitate and the upper layer of the wax solution.Note: 1) Samples can be left at room temperature after incubation at 56°C until the temperature of the water or dry bath reaches 90°C before placing the samples at 90°CIncubation.2) Optional step: add 7µL UNG (1U/µL), 50°C, 5min, no shaking. The purpose of this step is to minimize the risk of false positives by reducing the low-frequency occurrence of C>T:G>A transitions (artificial mutations) while effectively retaining the true occurrence of mutations.3. Optional step: If you need to remove RNA, you can lower the temperature of the sample to room temperature, then add 2µL of RNase A solution at a concentration of 100mg/mL, shake and mix well, and leave it at room temperature for 2 minutes.4. Add 20µL Proteinase K and incubate at 65℃, 450rpm for 15min.5. Add 200 µL of Buffer GL, mix well by vortexing and shaking, then add 200 µL of anhydrous ethanol and mix thoroughly by vortexing and shaking. Centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube.Note: 1) Mix well immediately after adding Buffer GL and anhydrous ethanol.2) The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.3) If more than one sample needs to be manipulated, the Buffer GL and anhydrous ethanol can be pre-mixed and spiked.6. Add all the solution obtained in step 5 to the adsorption columns (Spin Columns DF) that have been loaded into the collection tube, centrifuge at 25℃, 12000rpm for 2 minutes, pour out the waste liquid in the collection tube, and put the adsorption columns back into the collection tube.7. Add 500µL of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.8. Add 500µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12000rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 8 can be repeated if further DNA purity is required.9.12 Centrifuge at 2000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions.10. Place the adsorption column in a new 1.5 mL collection tube, add 20-100 µL of Buffer TE or sterilized water to the middle of the adsorption column overhanging the column, let it stand at room temperature for 2-5 minutes, centrifuge it at 12,000 rpm for 1 minute, and collect the DNA solution.-20°C to preserve DNA.Note: 1) The pH value of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH value is 7.0-8.5, the pH value is lower than 7.0 when the elution efficiency is not high.2) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 10 can be re-spiked onto the adsorbent membrane and left at room temperature for 2 minutes and centrifuged at 12,000 rpm for 1 minute... Read More | Product introduction: The MA qPCR live bacteria detection kit provides an effective means for detecting bacterial activity. The kit provides a mixture of PMA dye and qPCR based on SYBR Green dye. The optimal amount of dye and the number of samples that can be treated may vary depending on theProduct introduction: The MA qPCR live bacteria detection kit provides an effective means for detecting bacterial activity. The kit provides a mixture of PMA dye and qPCR based on SYBR Green dye. The optimal amount of dye and the number of samples that can be treated may vary depending on the type of sample. PMA is a high-affinity DNA-binding dye, especially with double-stranded DNA. The dye itself has weak fluorescence, but it can emit brighter fluorescence after binding to nucleic acids. PMA is impermeable to cell membranes, so it can selectively modify the DNA of dead cells with damaged membranes. After the PMA-modified DNA is photolyzed by blue light ( ~ 464 nm ), the photoreactive azide group on the PMA is converted into a highly reactive nitrene radical, which reacts with any hydrocarbon near the DNA binding site to form a stable covalent nitrogen-carbon bond, resulting in permanent DNA modification. This modification process will make DNA insoluble and lost with cell debris during the later genomic DNA extraction process. The unbound PMA remaining in the solution reacts with water molecules under strong light irradiation to decompose into hydroxylamine compounds without cross-linking activity, so that it can no longer covalently bind to DNA. Based on this feature of PMA, PMA was combined with qPCR technology to form a new detection method, PMA-qPCR, for the screening of live bacteria. At present, the method has been verified in a variety of bacterial strains, yeast, fungi, viruses and parasites. The treatment of complex samples, such as manure or soil, may require optimization of sample dilution, dye concentration, and light treatment time. The treatment of diluted samples, such as water testing, may require filtration or concentration prior to dye treatment. Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. the components of the kit contain fluorescent dyes. Avoid light during use and storage. 3. for your safety and health, please wear experimental clothes and disposable gloves.Product parameters:Spectral characteristics :PMA: Ex = 464 nm; Ex/Em = 510/610 nm (following photolysis and reaction with DNA/RNA)Component: PMA:Ex = 464 nm; Ex/Em = 510/610 nm (following photolysis and reaction with DNA/RNA) Instruction: Precautions before use: 1.This live bacteria detection kit distinguishes dead bacteria and live bacteria according to cell membrane permeability. Many methods of killing bacteria cause damage to the cell membrane and are therefore compatible with this kit. But some methods, such as ultraviolet irradiation, may not immediately cause cell membrane rupture. Therefore, before selecting this kit, it is necessary to carry out literature search and pre-experiment to determine whether the kit is suitable for the bacterial type and killing method you choose. 2.After PMA treatment, the bacteria need to be photolyzed to covalently bind the dye to dead cell DNA. Photolysis operations can use blue or white light sources. Generally speaking, the brighter the lamp, the higher the efficiency of the photolysis step. Non-LED lamps ( such as halogen lamps ) may heat your sample and have a negative impact on the analysis. Ice is required to cool the sample during irradiation. 3.Sample can be cryopreservation after photolysis. Frozen samples before PMA treatment photolysis may damage the cell membrane and produce false negative results. If the sample needs to be frozen before detection, it is recommended to perform a pre-experiment first. 4.Part of the mechanism of PMA is to remove PMA covalently modified DNA from the sample by precipitation ; therefore, when extracting genomic DNA, it is necessary to use the same volume of genomic DNA eluent for volume normalization. The positive control can use the genomic DNA of living cells. 5.In order to verify the effectiveness of PMA in the test sample, the Ct ( dCt ) changes between- / + PMA can be compared. Experimental materials ( self-provided ):①Light source ( for the photolysis step after PMA modification of DNA ) ; ② Bacterial genomic DNA extraction kit ; ③ effective qPCR primers corresponding to the sample type Experimental procedure: 1.Suck 10 µL of E.coli bacterial solution in liquid LB medium, and culture E.coli in the bacterial incubator overnight or longer to the logarithmic growth phase ( OD600 ≈ 1.0 ) ; Note : The culture time is adjusted according to the experiment. 2.Two portions of live E.coli, 400 µL each, were placed in a clean centrifuge tube ; 3. ( Recommended ) Preparation of dead E.coli. If the dead E.coli is needed as a control, the dead E.coli can be obtained by heating the living E.coli in a water bath at 95 °C for 5 min, or at 58 °C for 3 h. the subsequent operation of the dead E. coli is the same as that of the living E. coli ; 4.Two copies of live E.coli, one without PMA treatment, and one with 25 µM PMA treatment ( the optimal PMA concentration for treating different types or different sources of bacteria needs to be consulted in the relevant literature ) ; 5.The PMA-treated samples were placed on a shaker at room temperature and incubated in the dark for 10 min to fully mix the dye with the sample ; 6.Exposure of the sample, you can use blue or white light source, irradiation time to explore their own. For example, a 60 W blue light can be used for 15 min. Note : 1 If a halogen lamp is used, we recommend that the PMA-treated sample tube be placed on an ice block 20 cm away from the light source. Ice should be placed in a transparent tray. Adjust the light source to point directly to the sample, photolysis for 5-15 min ; if the bacteria obtained from the environment are directly used for experiments, due to the complexity or turbidity of the environmental samples, the photolysis time needs to be prolonged appropriately. 7.Treated and untreated live E.coli 5000 × g, centrifuged for 10 min, remove the supernatant ; 8.Select the appropriate genomic DNA extraction kit according to the sample type, and use the same elution volume for each group of samples when elution DNA. Note : DNA extraction steps refer to the instructions of the kit used. Part of the mechanism of action of PMA is to remove PMA-bound DNA from the sample by precipitation ; therefore, when extracting genomic DNA, each group should use the same volume of genomic DNA eluent for volume normalization ( the amount of genomic DNA extracted from dead bacteria and live bacteria is inconsistent, so the concentration of the two is significantly different ). 9.Preparation of reaction mixture according to the following system : Note : 1 For the DNA extracted by commercial DNA extraction kit, the qPCR template was optimized with 2 µL as the initial volume ; 2 The template volume should not exceed 10 % of the final reaction volume ; 3 Template concentration : gDNA as template, usually 1-10 ng ; the final concentration of PCR primers is usually 0.4µM, which can get better results. When the reaction performance is poor, the primer concentration can be adjusted in the range of 0.2-1µM. 10.Slightly vortex the reaction mixture, transfer the fixed volume to the PCR tube. 11. Test procedure Note : 1 The extension time is adjusted according to the instrument ; the Taq enzyme in mix can be activated within 2 min, but the genomic DNA may require longer denaturation time, which can be increased at this time, and the specific denaturation time can be adjusted according to the sample type.12. ( Optional ) Data analysis Using live bacteria and dead bacteria as controls, the number of live cells in the sample was analyzed and calculated. It is recommended to verify the suitability of primers and PCR procedures before starting PMA qPCR detection of live bacteria. Calculation of dead and living bacteria control dCt ( 1 ) After the end of qPCR, the Ct value of each sample was calculated by instrument software ; ( 2 ) By calculating the dCt of each control bacteria, it was judged whether PMA successfully inhibited the amplification of dead bacterial DNA. The calculation is as follows : dCt live = Ct ( live, PMA treated ) -Ct ( live, PMA untreated ) dCt die = Ct ( die, PMA treated ) -Ct ( die, PMA untreated ) ( 3 ) The dCt expectation of living bacteria is close to 0 ± 1, which indicates that PMA does not affect the amplification of living cell DNA ;( 4 ) The expected value of dCt of dead bacteria is greater than 4 ( dCt is 4 means that it is reduced by about 16 times, that is, 94 % of dead bacterial DNA is removed ; a dCt of 8 indicated a decrease of about 250 times, that is, 99.6 % of the dead bacterial DNA was removed ).( 5 ) The dCt of dead bacteria depends on many factors, including : strain / cell type ; the way bacteria are killed ; the concentration of PMA used ; amplified sequence length. 13. Calculation of the proportion of viable ( optional ) bacteria If the control results of dead and live bacteria are normal, the proportion of live bacteria in the sample can be calculated.( 1 ) Calculate the dCt value of the sample : dCt sample = Ct ( sample, PMA treated ) -Ct ( sample, PMA untreated ) ( 2 ) Conversion of dCt value to live bacteria ratio : PMA inhibition multiple = 2 ( sample dCt ) Viable bacteria % = 100 / PMA inhibition multiple 14. ( Optional ) Calculate the absolute number of live bacteria If you want to calculate the absolute number of viable bacteria in the sample, you need to use a known number of target bacteria genomic DNA to make a standard curve. It is recommended that the diluted concentrations of several groups of genomes are within the range of the qPCR analysis system.( 1 ) qPCR was performed with the appropriate genome, and the Ct value was used as the ordinate, and the number of cells was used as the abscissa. The R2 value is calculated to determine the linearity, and the slope and y-axis intercept are displayed. ( 2 ) Calculate the copy number of the experimental samples : Ct = slope * cell number + y axis intercept ( y = mx + b ) Bacterial count sample = ( Ct-y axis intercept ) / slope Note : The live bacterial DNA was not lost during the purification process. Examples : Scope of application:Live bacteria detection... Read More | Product contentComponentY665957-1mlY665957-5ml2×GoldStar Probe Mixture1 ml5×1 mlProbe Primer Mix300 µl5×300 µlHuman DNA Standard(100 ng/µl)100 µl5×100 µl50×High ROX40 µl200 µlProduct IntroductionThis product is a real-time Product contentComponentY665957-1mlY665957-5ml2×GoldStar Probe Mixture1 ml5×1 mlProbe Primer Mix300 µl5×300 µlHuman DNA Standard(100 ng/µl)100 µl5×100 µl50×High ROX40 µl200 µlProduct IntroductionThis product is a real-time fluorescence quantitative PCR kit for detecting the concentration of human male Y chromosome, including carefully optimized PCR reaction solution, primer mixture and standards, especially suitable for the quantitative detection of precious and micro DNA samples. The kit adopts a new efficient and fast hot-start amplification enzyme GoldStar Taq DNA Polymerase, which effectively avoids non-specific amplification caused by non-specific binding of primers and templates or primer dimerization at room temperature. This product realizes accurate quantification of Y chromosome and can be applied in various fields such as genetic mapping, species polymorphism research, disease gene localization, paternity testing and forensic analysis.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Method of Use 3.Scope of applicationThis product is suitable for quantitative testing of male Y chromosome DNA in scientific research, clinical, forensic medicine and paternity testing.Usage1. Amplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.05-10 ng/µL. 4°C on ice was set aside.2. Standard dilution: according to the following table, firstly dilute Human DNA Standard (100ng/uL) with TE to make 5 standards of different concentrations according to the table below. 10ng/µL of DNA Standard 1 (Std.1) can be stored stably at -20℃ for 1 month; Std2-5 can only be used on the same day, and should be placed at 4℃ or on ice when not in use for the time being after preparation. When Std2-5 are not used temporarily after preparation, they should be stored at 4℃ or on ice.Standard sampleCorresponding concentration(ng/µl)Minimum Dilution Volume (Unit:µl)Std.11010 [100 ng/µl DNA Standard]+ 90 TEStd.22.520 [Std. 1] +60 TEStd.30.62520 [Std. 2] +60 TEStd.40.1562520 [Std. 3] +60 TEStd.50.039062520 [Std. 4] +60 TE3. qPCR reaction system preparationBefore preparation, the cryopreserved reagents to be used were completely melted and mixed by inverting several times, then centrifuged briefly and prepared. Standards and templates were diluted as described above and prepared.The base reaction system for 20 µL was as follows:Reagent20 µl Reaction system2×GoldStar Probe Mixture10 µlProbe Primer Mix3 µlTemplate4 µlddH₂O3 µlNote: High ROX model: add 1 µL of 50×High ROX per 50 µL of reaction system; Low ROX model: add 1 µL of 50×High ROX per 500 µL of reaction system.A sufficient amount of reaction system mixture was prepared according to the need, and after the reaction system was prepared and mixed thoroughly, it was added to the reaction wells in a volume of 16 µl per well. Then add the prepared standards and diluted samples into the corresponding reaction wells, the amount of addition is 4µL/well. TE was added to the blank control tube, and the same amount was added at 4 µL/well.It is recommended to use 20 µL for the reaction, if you need to perform a smaller system reaction, reduce the system components in equal proportion.4. qPCR reaction programThe PCR mix of this kit contains a FAM fluorescent probe for the target gene and a VIC fluorescent probe with internal reference to Internal PCR Control (IPC). qPCR program with dual fluorescence of hydrolyzed probes needs to be selected for the assay. Please follow the instructions of the instrument used to set up the qPCR program, and the PCR temperature conditions are as follows:1. Standard curve productionThe standard curve was plotted with reference to the Excel sheet for data processing. The correlation coefficient R2 of the standard curve should be not less than 0.98, and the slope should be located between -3.1 and -3.6 when the Ct value is used as the longitudinal coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard Concentration(ng/µL)DNA Standard 110DNA Standard 22.5DNA Standard 30.625DNA Standard 40.15625DNA Standard 50.03906252. Analysis of results and calculation of concentrationsThe Ct difference between experimental replicate wells for FAM signaling of the target gene should be no more than 0.3, otherwise invalid data need to be deleted or the experiment needs to be repeated, do not use Ct outside the valid Ct range of the standard curve to calculate the concentration of the sample.For specific calculations, please refer to the data processing Excel for this product.If the FAM signal is abnormal, the VIC signal of the internal reference Internal PCR Control (IPC) needs to be analyzed to confirm whether the PCR reaction process is abnormal. If the Ct value of the sample null VIC is significantly larger than that of the standard or blank control wells, it means that the sample inhibits the PCR reaction.matters needing attention1. Before testing, these instructions should be read in detail. It should be operated by personnel with professional experience or qualified by training.2. For use, please mix gently by turning up and down, avoid foaming as much as possible, and use it after centrifugation for a short period of time.3. Avoid repeated freezing and thawing of the product, repeated freezing and thawing may degrade the performance of the product.4. When preparing the reaction solution, please use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More |