| Description | Format:2-ComponentEnzyme:Horseradish peroxidase | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | G665573 Component 10 T Storage G665573A Buffer P1 30 mL RT G665573B Buffer P2 30 mL RT G665573C Buffer E3 30 mL RT G665573D Buffer PS 15 mL RT G665573E Buffer PW (concentrate) 10 mL RT G665573F Endo-Free Buffer EB 30 mL RT G665573G RNase A (10 mg/mL) 600 碌L RT G665573H Endo-Remover FX 10 EA G665573 Component 10 T Storage G665573A Buffer P1 30 mL RT G665573B Buffer P2 30 mL RT G665573C Buffer E3 30 mL RT G665573D Buffer PS 15 mL RT G665573E Buffer PW (concentrate) 10 mL RT G665573F Endo-Free Buffer EB 30 mL RT G665573G RNase A (10 mg/mL) 600 碌L RT G665573H Endo-Remover FX 10 EA RT G665573I Plungers 10 EA RT G665573J Spin Columns DX with Collection Tubes 10 EA RT G665573K Centrifuge Tubes (15 mL) 10 EA RTProduct IntroductionThis kit is specially designed for the efficient and rapid extraction of plasmids from 15-50 ml of bacterial fluids. On the basis of cell lysis by alkaline lysis method, it adopts unique silicon matrix membrane adsorption technology to bind plasmid DNA efficiently and exclusively, and each adsorption column can adsorb up to 250 µg of plasmid DNA; at the same time, it adopts a special buffer system and endotoxin removal filter to effectively remove endotoxin, genomic DNA, RNA, protein and other impurities. The plasmids obtained from this kit are of high purity and stable quality, and can be used for cell transfection, as well as DNA sequencing, PCR, in vitro transcription, endonuclease digestion and other experiments.Self-contained reagents: anhydrous ethanol, isopropanol.Pre-experiment Preparation and Important Notes1. All components are stable for 1 year in a dry, room temperature (15-30°C) environment, and longer by placing the adsorption columns at 2-8°C. Buffer P1 with RNase A is stable for 6 months at 2-8°C.2. Before the first use, add all of the RNase A solution to Buffer P1, mix well, and store at 2-8°C. Before use, it needs to be left at room temperature for a period of time, return to room temperature and then use.3. Anhydrous ethanol should be added to Buffer PW before the first use according to the instructions on the reagent bottle label.4. Please check Buffer P2 and Buffer E3 for crystallization or precipitation before use. If there is any crystallization or precipitation, the clarification can be restored by taking a water bath at 37℃ for a few minutes.5. Be careful not to touch Buffer P2 and Buffer E3 directly, and tighten the lid immediately after use.6. The amount and purity of extracted plasmid is related to the concentration of bacterial culture, strain type, plasmid size, plasmid copy number and other factors.7. The adsorption columns treated with Buffer PS should be used immediately to avoid leaving them for too long.Operation steps1.Take 15-50 ml of fresh bacterial solution from the overnight culture, add it to a centrifuge tube (self-prepared) and centrifuge at 5000 × g for 10 minutes to collect the bacteria, and aspirate all the supernatant as much as possible.2.Add 2.5 ml of Buffer P1 to the centrifuge tube in which the bacterial precipitate has been left (please check that RNase A has been added first) and suspend the bacterial precipitate by mixing thoroughly using a pipette or vortex shaker. Note: If the bacterial mass is not thoroughly mixed, it will affect the lysis effect and make the extraction amount and purity low.3.Add 2.5 ml of Buffer P2 to the centrifuge tube, mix gently up and down 8-10 times to fully lyse the organisms, and leave at room temperature for 3-5 minutes. At this point the solution should become clear and viscous. Note: Mix gently, do not shake vigorously, so as not to interrupt the genomic DNA and cause genomic DNA fragments to be mixed in the extracted plasmid. If the solution does not become clear, it suggests that the amount of bacteria may be too large and the lysis is not complete, and the amount of bacteria should be reduced.4.Add 2.5 ml of Buffer E3 to the centrifuge tube and mix immediately by turning up and down 8-10 times, at which time a white flocculent precipitate appears. Note: Buffer E3 should be mixed immediately after addition to avoid localized precipitation.5.Install the cap of the filter (Endo-Remover FX), transfer the solution obtained in step 4 to the filter, wait until the white flocculent precipitate floats on the upper layer of the solution, remove the cap of the filter, align the filter with a clean 15 ml centrifuge tube (supplied), and slowly push the handle (Plungers) to filter, so that as much as possible of the solution passes through, and the filtrate is collected in the centrifuge tube.6.Add 1/3 solution volume of isopropanol to the filtrate and mix upside down.7.Column Equilibrium: Add 1ml Buffer PS to the adsorption column (Spin Columns DX) that has been loaded into a 15ml centrifuge tube, centrifuge for 2 minutes at 2500 x g. Pour off the waste liquid from the centrifuge tube and put the adsorption column back into the centrifuge tube.8.The mixture of filtrate and isopropanol from step 6 was transferred to the equilibrated adsorption column (which had been loaded into a collection tube).9.Centrifuge at 2500 x g for 1 minute, pour off the waste solution in the collection tube and put the adsorption column back into the collection tube. Note: The maximum volume of the adsorption column is 4 ml, so the solution obtained in step 8 is passed through the column in 2 times.10.Add 2 ml of Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first), centrifuge at 2500 × g for 1 min, and pour off the waste liquid in the collection tube.11.Repeat step 10.12.The adsorbent column was put back into the collection tube and centrifuged at 2500 × g for 2 min, the waste liquid was poured off, and the column was left to dry at room temperature for 5 min.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.)13. Place the adsorption column in a new 15 ml centrifuge tube, add 0.5-1 ml Endo-Free Buffer EB to the middle of the adsorbent membrane, leave it at room temperature for 2-5 minutes, centrifuge it at 2500 × g for 2 minutes, and collect the plasmid solution into the centrifuge tube. -20°C to store the plasmid.Note: 1) In order to increase the recovery efficiency of the plasmid, the obtained solution can be reintroduced into the adsorption column, left at room temperature for 2-5 minutes, centrifuged at 2500 x g for 2 minutes, and the plasmid solution can be collected into a centrifuge tube.2) When the plasmid copy number is low or >10kb, Endo-Free Buffer EB can increase the extraction efficiency by preheating at 65-70°C in a water bath... Read More | Inquire | Product content: S665546Component50 TStorageS665546ABuffer QSL45 mLRTS665546BBuffer RIL11 mL2-8℃S665546CBuffer ML10 mLRTS665546DBuffer GW1 (concentrate)13 mLRTS665546EBuffer GW2 (concentrate)26 mLRTS665546FBuffer EBL13 mLRTS665546GRNase A240 µLRTS665546HLysis Tubes Ⅱ50 Product content: S665546Component50 TStorageS665546ABuffer QSL45 mLRTS665546BBuffer RIL11 mL2-8℃S665546CBuffer ML10 mLRTS665546DBuffer GW1 (concentrate)13 mLRTS665546EBuffer GW2 (concentrate)26 mLRTS665546FBuffer EBL13 mLRTS665546GRNase A240 µLRTS665546HLysis Tubes Ⅱ50 EARTS665546ISpin Columns DM With Collection Tubes50 EARTProduct IntroductionThis kit provides a method for extracting total DNA from soil or fecal samples, including the total DNA of cells, bacteria, parasites, and viruses in the samples. It is also suitable for extracting DNA from samples containing high concentrations of PCR reaction inhibitors. This reagent kit adopts a unique buffering system to efficiently bind DNA from the lysis solution to the adsorption column. Inhibitors of PCR and enzyme reactions, as well as residual impurities, can be effectively removed through washing steps. Finally, high-purity DNA can be obtained by washing with low salt buffer or water. The purified DNA can be directly used for downstream experiments such as second-generation sequencing (16S amplicons and metagenomes), library construction, PCR, qPCR, Southern Blot, enzyme digestion molecular markers, etc.Self prepared reagents1. Constant temperature mixer - Product number: CW25932. Anhydrous ethanol, isopropanol3. Vortex oscillator or tissue grinderPreparation and important precautions before the experiment1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to Buffer GW1 (concentrate) and Buffer GW2 (concentrate) according to the instructions on the reagent bottle label.3. Take out the buffer RIL before use and store it at 2-8 ℃ immediately after use.Operation steps1. Centrifuge the Lysis Tube briefly to allow the beads to settle at the bottom.2. a. Add 0.1-0.3 g of soil or fecal sample to Lysis Tube, and add 740-820 µ L Buffer QSL and 4 µ L RNase A, tighten the tube cover and briefly vortex to mix.b. If fecal samples are stored in non lytic fecal preservation solutions (such as CWY041S and CWY041M), add 200 to Lysis Tube µ L-600 µ L solid-liquid mixture, centrifuge at 13000 rpm for 1 minute, discard the storage solution (if the amount of solid after centrifugation is too small, it can be enriched again, but should not exceed 0.3g). Join 620 µ LBuffer QSL and 4 µ L RNase A, tighten the tube cover and briefly vortex to mix.3. Fix the Lysis Tube in an oscillating grinding device equipped with a 2 mL adapter and process it according to the optimized grinding conditions of your equipment (see appendix).4. Shake the Lysis Tube on a constant temperature mixer at 70 ℃ and 1200 rpm for 10 minutes. Subsequently, centrifuge at 13000 rpm for 2 minutes to precipitate solid particles. Transfer 540 µ Transfer the supernatant to a new 2 mL centrifuge tube.5. Add 180 µ L Buffer RIL, vortex for 5 seconds, centrifuge at 13000 rpm for 2 minutes.Attention: Remove the buffer RIL before use and store it at 2-8 ℃ immediately after use.6. Add 160 to the new centrifuge tube in sequence µ L Buffer ML, 480 µ Supernatant from step 5, 320 µ L isopropanol, vortex for 5 seconds.7. Transfer the solution from the previous step to 650 µ Centrifuge at 12000 rpm (~13400 × g) for 1 minute into the spin columns DM that have been loaded into the collection tube.8. Discard the waste liquid in the collection pipe and place the adsorption column back into the collection pipe. Repeat step 7 until all the solution has been transferred.9. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.10. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. 11. Repeat step 10.12.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).13. Place the adsorption column in a new centrifuge tube (self provided) and add 50-200 drops of suspended droplets to the middle of the adsorption column µ L Buffer EBL or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) Incubating at room temperature for 5 minutes before centrifugation can increase yield.2) Use an additional 50-100 µ Further elution with L buffer or sterilized water can increase yield.3) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 13 back onto the adsorption membrane and repeat step 13, but it may reduce the total yield.4) The elution buffer does not contain chelating agents, please store DNA at -20 ℃.5) The residual trace PCR inhibitors in the genomic DNA template may have adverse effects on the PCR reaction, which can usually be resolved by diluting the DNA by 2-10 times.Appendix: Grind the sample using one of the following methods1. Manually vortex oscillate at maximum speed on the vortex oscillator for 10 minutes.2. On a vortex oscillator equipped with a 1.5-2 mL horizontal centrifuge tube holder, oscillate at maximum speed for 10 minutes (keeping the Lysis Tube horizontal). If the sample size exceeds 12, extend by 5-10 minutes. For example, using Scientific Industries or Mobile's Vortex Genie2 vortex oscillator.3.When using Qiagen's TissueLyser II, grind at 25Hz for 10 minutes.4.When using Qiagen's PowerLyzer 24 Homogenizer, homogenize at 2000 rpm for 30 seconds, pause for 30 seconds, and then homogenize again at 2000 rpm for 30 seconds.5.When using FastPrep-24 from MP Biomedicals, the recommended speed is 6.0 and the time is 40 seconds... Read More |