| Description | H665581 Component 100 T Storage H665581A gDNA Eraser 50 µL -20℃. Avoid freeze/thaw cycle. H665581B 10×gDNA Eraser Buffer 120 µL -20℃. Avoid freeze/thaw cycle. H665581C HiFiScript, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665581D 5×ScriptRT H665581 Component 100 T Storage H665581A gDNA Eraser 50 µL -20℃. Avoid freeze/thaw cycle. H665581B 10×gDNA Eraser Buffer 120 µL -20℃. Avoid freeze/thaw cycle. H665581C HiFiScript, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665581D 5×ScriptRT Buffer 500 µL -20℃. Avoid freeze/thaw cycle. H665581E Primer Mix 120 µL -20℃. Avoid freeze/thaw cycle. H665581F RNase-Free Water 2×1 mL -20℃. Avoid freeze/thaw cycle.Product IntroductionThis product is a kit for removing genomic DNA for reverse transcription. The kit removes genomic DNA in 2 minutes at 42°C. Since the reverse transcription reagent contains a component that inhibits gDNA Eraser, cDNA can be synthesized directly by reverse transcription of gDNA Eraser-treated samples.The kit is equipped with a new high-efficiency reverse transcription enzyme, HiFiScript, with novel mutation sites that dramatically increase the transcriptional activity of the enzyme, resulting in higher efficiency and yield of cDNA first-strand synthesis. The first strand of cDNA can be synthesized with higher efficiency and yield, and the first strand of cDNA can be synthesized from pg total RNA or mRNA. If the reverse transcription product cDNA is used for downstream fluorescence quantitative detection, the reverse transcription reaction can be completed at 42℃ in 15 minutes. This kit is suitable for the synthesis of first-strand cDNA and subsequent RT-PCR, RT-qPCR, and the construction of full-length cDNA libraries.Product Features1. Rapid genome removal: contains gDNA Eraser for genomic DNA removal, which removes genomic DNA in just 2 minutes.2. Rapid reverse transcription: 15 minutes to obtain fluorescent quantitative PCR template cDNA first strand synthesis.3. High sensitivity: cDNA first strand can be synthesized using pg-level total RNA or mRNA templates.4. Highly efficient reverse transcription: Novel mutation sites dramatically increase enzyme activity, resulting in higher yields of cDNA.matters needing attention1. During operation, RNase contamination should be avoided to prevent RNA degradation or cross-contamination in the experiment. It is recommended that operators wear masks and disposable gloves and change the gloves frequently, and use specialized instruments and consumables.2. The reverse transcription system is prepared and operated on ice to prevent degradation of RNA. Store the kit enzymes at -20ºC as soon as possible after use and try to avoid repeated freezing and thawing.3. The reaction system can be scaled up to a maximum of 1 µg of total RNA in 10 µl of reaction system.4. Primer Mix is prepared by Oligo(dT) and Random primer, and Oligo-dT Primer or Gene Specific Primer can also be used according to the experimental needs.5. If the amount of starting RNA is less than 50ng, it is recommended to add RNAase inhibitor (RNasin).6. For RNA templates with complex secondary structures, it is recommended to incubate the template RNA at 65°C for 5 minutes immediately on ice prior to the manipulation step and centrifuge briefly before proceeding to the next step.UsageThaw template RNA on ice; place kit components on ice immediately after thawing at room temperature. Each solution was mixed by vortexing and shaking before use and briefly centrifuged.I. Genomic DNA removal reactions1. Prepare the reaction system according to the following table on ice in a total volume of 10 µl. To ensure the accuracy of the reaction solution preparation, prepare the premixed system in the amount of reaction number + 2 before dispensing it into each reaction tube and finally adding the RNA sample.Note: 1) If the amount of total RNA is greater than 1µg, scale up the reaction system proportionally. If the amount of starting RNA is less than 50ng, it is recommended to add RNAase inhibitor (RNasin).2. Mix by vortex shaking and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.3. Incubate at 42°C for 2 minutes (this can be extended to 30 minutes for room temperature reactions).4.At the end of the reaction, centrifuge briefly and place on ice to cool.II. Reverse transcription reaction1. Prepare the reaction system on ice according to the following table. In order to ensure the accuracy of the reaction solution configuration, first prepare a premixed solution in the amount of number + 2, and then dispense 10 µl into each reaction tube, take 10 µl of the prepared premixed solution and add it to the reaction tube of step 1 where the de-etching of the genome has been completed.Note: 1) Oligo-dT Primer or Gene Specific Primer can be used according to the needs of the experiment, it is recommended to use 50 pmol of Oligo-dT Primer or 2 pmol of Gene Specific Primer for 20 µl reaction system.2. Mix well and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.3. cDNA synthesis reaction conditions:1) If fluorescent quantitative PCR assay is performed downstream, incubate at 42°C for 15 minutes and 85°C for 5 minutes.2) If downstream for normal PCR assay, incubate at 42°C for 30-50 minutes and 85°C for 5 minutes. Note: For templates with complex secondary structure or high GC content, the reverse transcription temperature can be increased to 50°C to enhance reverse transcription efficiency.4. At the end of the reaction, centrifuge briefly and place on ice before proceeding with subsequent PCR or fluorescence quantitative PCR, or place at -20°C if prolonged storage is required.Note: When performing Real-time PCR reactions, the amount of reverse transcription product added should not exceed 1/10 of the total volume of the PCR reaction... Read More | D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H Buffer EB 4 mL RT D665729I Buffer PS 10 mL RT D665729J Spin Columns DF 50 Pcs 2-8 ℃ D665729K Collection Tubes 50 Pcs RTProduct Introduction:The basic principle of this reagent kit is that after DNA is treated with sodium bisulfite, unmethylated cytosine can be transformed into uracil, while methylated cytosine remains unchanged. And adopting an innovative high-temperature treatment method, the transformation time is greatly shortened, the transformation efficiency is improved, and the transformation efficiency can reach over 99%. At the same time, using a silicon-based membrane purification column, DNA can be recovered and purified from the methylated solution through a simple binding washing elution step. The recovered DNA has high purity and good integrity, and can be directly used for sequencing, methylated PCR detection, chip analysis, connection and transformation, enzyme digestion, labeling, microinjection, PCR and in vitro transcription and other molecular biology experiments.Self prepared reagents: anhydrous ethanol, 75% ethanol.Preparation and important precautions before the experiment1. Product usage method:(1) 10 times packaging preparation method: CT Conversion Agent is a solid mixture that must be prepared before first use. Add 2 ml sterile water and 100 µ M-Dissolving Buffer and 300 µ Add M-Diffusion Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 10 DNA treatments. In order to achieve better results, the prepared CT Conversion Agent should be used immediately. If not used immediately, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.(2) 50 times packaging preparation method: CT Conversion Agent and M-Dissolving Buffer are solid mixtures that must be prepared before first use. Add 5 ml of sterile water to the M-Dissolving Buffer and shake to dissolve. After all the solids have dissolved, transfer all the solution from the M-Dissolving Buffer tube to the CT Conversion Agent tube and add 5.5 ml of sterile water. Add 1.5 ml of M-Dilution Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 50 DNA treatments. In order to achieve better results, the CT Conversion Agent should be used immediately after preparation. If not immediately used, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.2. Before the first use, anhydrous ethanol should be added to the M-Wash Buffer according to the instructions on the reagent bottle label.Operation stepsThe range of DNA prepared each time is 1 ng-4 µ Between g, the optimal amount is 500 ng-2 µ G.1. Take 20 µ Add DNA sample into centrifuge tube (self provided), and if the sample amount is insufficient, replenish with water up to 20 µ L.2. Add 2.2 to the DNA sample µ Mix the sample well with the M-Dilution Buffer of l.3.42 ℃ water bath for 30 minutes.4. Add 220 to the sample obtained from the previous step µ Prepare the CT Conversion Agent solution, mix well, and incubate in an 80 ℃ constant temperature water bath in a dark place for 60 minutes.5. Add 480 to the solution in the previous step µ M - Buffer PA, gently mix upside down.6. Column balance: Add 200 to the spin columns DS that have been loaded into the collection tube µ Centrifuge at 12000 rpm (~13400 × g) for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7.Add all the solution obtained from step 5 to the adsorption column (already loaded into the collection tube), let it stand at room temperature for 2 minutes, centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Attention: The maximum capacity of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.8. Add 500 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute using M-Buffer PA, discard the waste liquid from the collection tube, and place the adsorption column in the recovery tube.9. Add 650 to the adsorption column µ M-Wash Buffer (please check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.10.12000 rpm for 2 minutes, discard the waste liquid, and place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column into a new centrifuge tube (provided by oneself), and add 20 drops to the middle position of the adsorption membrane in the air µ M-Elution Buffer (pH 8.5), leave at room temperature for 2 minutes. Collect DNA solution by centrifugation at 12000 rpm for 1 minute.12. Collect 20 µ Add 2.2 to DNA µ M-Diffusion Buffer, let it stand at room temperature for 30 minutes.13. Add 500 to the solution µ After pre cooling anhydrous ethanol, invert and mix well, and place the solution at -20 ℃ to precipitate for 30 minutes (overnight precipitation is more effective).14.12000 rpm for 15 minutes and gently discard the supernatant.15. Add 75% ethanol, centrifuge at 12000 rpm for 1 minute, pour out the supernatant, wait for ethanol to evaporate at room temperature, then add 20 µ Dissolve the M-Elution buffer and store the DNA at -20 ℃. The DNA collected in this step can be used for subsequent related experiments... Read More | Product content:E665636Component50 TStorageE665636ABuffer P115 mLRTE665636BBuffer P215 mLRTE665636CBuffer E315 mLRTE665636DBuffer PS15 mLRTE665636EBuffer PW (concentrate)10 mLRTE665636FEndo-Free Buffer EB10 mLRTE665636GRNase A (10 mg/mL)150 µLRTE665636HEndo-Remover FMwith Collection Tubes50 Product content:E665636Component50 TStorageE665636ABuffer P115 mLRTE665636BBuffer P215 mLRTE665636CBuffer E315 mLRTE665636DBuffer PS15 mLRTE665636EBuffer PW (concentrate)10 mLRTE665636FEndo-Free Buffer EB10 mLRTE665636GRNase A (10 mg/mL)150 µLRTE665636HEndo-Remover FMwith Collection Tubes50 EARTE665636ISpin Columns DMwith Collection Tubes50 EART Product Introduction:Endotoxins are a common pollutant in plasmid extraction. Due to the high sensitivity of eukaryotic cells to endotoxins, the presence of endotoxins in plasmids can greatly reduce the transfection efficiency of eukaryotic cells. This reagent kit provides a simple, fast, and efficient new method for extracting endotoxin free plasmids. The extracted plasmids remove endotoxins to the maximum extent possible and can effectively remove contamination of genomic DNA, RNA, proteins, etc. The operation is simple and convenient. This reagent kit is suitable for extracting 1-5mL of bacterial solution. On the basis of alkaline lysis of cells, it efficiently and specifically binds plasmid DNA through a new silicon-based membrane. Each adsorption column can adsorb up to 40% µ The plasmid DNA of g is effectively removed using a special buffer system and endotoxin removal filter column, effectively removing impurities such as endotoxins and proteins. The plasmid obtained from this kit has high purity and stable quality, making it particularly suitable for cell transfection. It can also be used for downstream experiments such as DNA sequencing, PCR, PCR based mutations, in vitro transcription, transformed bacteria, and endonuclease digestion.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1. All components can be stably stored for 1 year in a dry, room temperature (15-30 ℃) environment. The adsorption column can be stored for a longer time at 2-8 ℃. Buffer P1 with RNase A added can be stably stored for 6 months at 2-8 ℃. 2. Before the first use, add all RNase A solution to Buffer P1, mix well, and store at 2-8 ℃. Before use, let it sit at room temperature for a period of time. After returning to room temperature, use.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer P2 and Buffer E3. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. Be careful not to come into direct contact with Buffer P2 and Buffer E3, and immediately cover them tightly after use.6.The amount and purity of plasmid extraction are related to factors such as bacterial culture concentration, strain type, plasmid size, and plasmid copy number.Operation steps:1. Take 1-5 mL of overnight cultured bacterial solution and add it to a centrifuge tube (provided). Centrifuge at 13000 rpm (~16200 × g) for 30 seconds to collect bacteria, and try to discard all the supernatant as much as possible.2. Add 250 to the centrifuge tube containing bacterial sediment µ L Buffer P1 (please check if RNase A has been added first), mix thoroughly with a pipette or vortex oscillator, and suspend bacterial precipitation.Attention: If the bacterial blocks are not thoroughly mixed, it will affect the cracking effect, resulting in low extraction amount and purity.3. Add 250 to the centrifuge tube µ L Buffer P2, gently invert and mix 8-10 times, allowing the bacterial cells to fully lyse. Leave at room temperature for 3-5 minutes. At this point, the solution should become clear and viscous.Attention: Mix gently and do not shake vigorously to avoid interrupting genomic DNA and mixing genomic DNA fragments in the extracted plasmid. If the solution does not become clear, it indicates that the bacterial count may be too high and the lysis may not be complete. The bacterial count should be reduced.4. Add 250 to the centrifuge tube µ L Buffer E3, immediately invert and mix 8-10 times until white flocculent precipitates appear. Let it stand at room temperature for 5 minutes. Centrifuge at 13000 rpm for 5 minutes, extract the supernatant, and add it to a filter column (Endo Remove FM). Centrifuge at 13000 rpm for 1 minute to filter, and collect the filtrate in a centrifuge tube (self provided).Attention: After adding Buffer E3, it should be mixed evenly immediately to avoid local precipitation. 5. Add 225 to the filtrate µ Mix L isopropanol upside down.6. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ L Buffer PS, centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Transfer the mixed solution of filtrate and isopropanol from step 5 to an equilibrium adsorption column (already loaded into a collection tube).8.13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Attention: The maximum volume of the adsorption column is 750 µ L. If the sample volume is greater than 750 µ L can be added in batches. 9. Add 750 to the adsorption column µ L Buffer PW (please check if anhydrous ethanol has been added first), centrifuge at 13000 rpm for 1 minute, and discard the waste liquid in the collection tube.10. Place the adsorption column back into the recovery manifold and centrifuge at 13000 rpm for 1 minute. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new collection tube and add 50-100 to the middle of the adsorption membrane µ L Endo Free Buffer EB, let it stand at room temperature for 2-5 minutes, centrifuge at 13000 rpm for 2 minutes, and collect the plasmid solution into a centrifuge tube- Store the plasmid at 20 ℃.Note: 1) To increase the efficiency of plasmid recovery, the obtained solution can be added back to the adsorption column, left at room temperature for 2-5 minutes, centrifuged at 13000 rpm for 2 minutes, and collected into a centrifuge tube.2) When the plasmid copy number is low or>10 kb, preheating the Endo Free Buffer EB in a water bath at 65-70 ℃ can increase the extraction efficiency... Read More | O665690 Component 50T Storage O665690A DNase I 1000 U -20℃.Avoid freeze/thaw cycle. O665690B 10×Reaction Buffer 1000 µL -20℃.Avoid freeze/thaw cycle. O665690C Buffer RLS 40 mL RT O665690D Buffer RW1 40 mL RT O665690E Buffer RW2 (concentrate) 11 mL RT O665690F RNase-Free Water O665690 Component 50T Storage O665690A DNase I 1000 U -20℃.Avoid freeze/thaw cycle. O665690B 10×Reaction Buffer 1000 µL -20℃.Avoid freeze/thaw cycle. O665690C Buffer RLS 40 mL RT O665690D Buffer RW1 40 mL RT O665690E Buffer RW2 (concentrate) 11 mL RT O665690F RNase-Free Water 10 mL RT O665690G Spin Columns FS with Collection Tubes 50 EA RT O665690H Spin Columns RM with Collection Tubes 50 EA RT O665690I RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTProduct IntroductionThis kit is suitable for extracting RNA from a wide range of plants, even from plants rich in polysaccharides and polyphenols, high quality RNA can be successfully extracted, such as rice leaves, wheat leaves, corn leaves, tobacco leaves, pine needles, ginkgo leaves, poplar leaves, pomegranate leaves, holly leaves, apples, peaches, pears, tomatoes, cherries, apricots, bananas, grapes, loquats, cinnamon rinds, cinnamon pulp, lychee fruit rinds, lychee pulp, soybean, peanut, corn, potato tuber, moonflower petal, pomegranate petal, shiitake mushroom, flat mushroom and other samples. The unique lysate formula can rapidly inactivate the RNA enzyme in the cell, effectively remove the effect of polysaccharide and polyphenol on RNA extraction, without the need for phenol, chloroform and other reagents, while using silicon matrix membrane adsorption of RNA for purification, the total RNA extracted is highly pure, without the contamination of genomes, proteins and other impurities, and can be used for Real Time RT-PCR, RT-PCR, It can be used for Real Time RT-PCR, RT-PCR, Northern Blot, Dot Blot, in vitro translation and other downstream experiments.RNA yieldSelf-contained reagents: β-mercaptoethanol, anhydrous ethanol (freshly opened or for RNA extraction)Pre-experiment Preparation and Important Notes1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips.(2) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.2. Avoid repeated freezing and thawing of the extracted samples, otherwise it will affect the rate and quality of RNA extraction.3. If Buffer RLS produces a precipitate, heat to dissolve it and leave at room temperature.4. Please add β-mercaptoethanol to Buffer RLS before use, add 20µl β-mercaptoethanol to 1ml Buffer RLS. Buffer RLS with β-mercaptoethanol can be stored for 1 month at room temperature.5. Anhydrous ethanol should be added according to the instructions on the reagent bottle label before using Buffer RW2 for the first time. Operation steps1. Homogenization: Take 50-100mg of plant tissue and quickly grind it into powder in liquid nitrogen, add 500µl of Buffer RLS (please check whether β-mercaptoethanol is added before use), and immediately mix it by vortexing with vigorous shaking.Note: For materials that are extremely rich in water content, such as watermelon pulp, tomato, pear pulp, etc., more material can be added appropriately, up to 200 mg; for starch-rich samples or mature leaves, the amount of Buffer RLS can be increased appropriately, up to 700 µl.2. Centrifuge at 12,000 rpm (~13,400 x g) for 2 min at 4°C.3. Transfer the supernatant into the filter columns (Spin Columns FS) that have been loaded into the collection tubes, centrifuge at 12,000 rpm at 4°C for 1 minute, carefully aspirate the supernatant in the collection tubes and transfer it to new RNase-Free centrifugation tubes (self-provided), avoiding the tip of the gun from touching the cell debris precipitation in the collection tubes as much as possible.4. Slowly add 0.5 times the volume of the supernatant in anhydrous ethanol, mix well (a precipitate may appear), and transfer the resulting solution together with the precipitate to a Spin Columns RM in a collection tube, or in two batches if you cannot add all of the solution at once. centrifuge the column for 1 minute at 12,000 rpm at 4°C. Dispose of the spent solution and place the column back into the collection tube. Centrifuge at 12,000 rpm for 1 minute at 4°C, discard the spent solution and return the column to the collection tube.5. Add 350 µl of Buffer RW1 to the adsorbent column RM, centrifuge at 12,000 rpm at 4°C for 1 min, discard the waste solution and put the adsorbent column back into the collection tube.6. Preparation of DNase I mixture: Take 52µl of RNase-Free Water, add 8µl of 10×Reaction Buffer and 20µl of DNase I (1U/µl) to it, mix well, and prepare a final volume of 80µl of reaction solution.7. Add 80µl of DNase I mixture directly to the adsorption column and incubate at 20-30°C for 15 minutes.8. Add 350 µl of Buffer RW1 to the adsorbent column RM, centrifuge at 12,000 rpm at 4°C for 1 min, discard the waste solution and put the adsorbent column back into the collection tube.9. Add 500 µl of Buffer RW2 to the adsorbent column RM (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 1 minute at 4°C, discard the waste solution and put the adsorbent column back into the collection tube.10. Repeat step 9.11. Centrifuge at 12,000 rpm for 2 minutes at 4°C.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (zymography, PCR, etc.).12. Load the adsorption column RM into new RNase-Free Centrifuge Tubes (1.5 ml), add 30-50 µl of RNase-Free Water dropwise to the middle part of the adsorption membrane overhang, leave it at room temperature for 2 min, and centrifuge at 12,000 rpm at 4°C for 1 min, and store the resulting RNA solution at -70°C to prevent degradation.Note: 1) The volume of RNase-Free Water should not be less than 30 µl, too small volume affects the recovery rate.2) If you want to increase the RNA yield, repeat step 12 with 30-50 µl of fresh RNase-Free Water.3) If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 12 repeated... Read More | Inquire |