| Description | DescriptioniPE-Quick Kit is intended for the advanced confirmation of target protein expression utilizingE. Coliextract before the use of theiPE kit (Prod. No. 905089) | Alanine Aminotransferase (ALT), also known as serum glutamic-pyruvic transaminase (SGPT), is a pyridoxal-phosphate-dependent enzyme that catalyzes the reversible transfer of an amino group from alanine to α-ketoglutarate, generating pyruvate and glutamate. ALT is found primarily in liver and Alanine Aminotransferase (ALT), also known as serum glutamic-pyruvic transaminase (SGPT), is a pyridoxal-phosphate-dependent enzyme that catalyzes the reversible transfer of an amino group from alanine to α-ketoglutarate, generating pyruvate and glutamate. ALT is found primarily in liver and serum, but occurs in other tissues as well. Hepatocellular injury often results in an increase of serum ALT levels and serum ALT levels can be used as a marker for liver injury.ALT Activity Assay kit has been used to determine the activity of alanine aminotransferase (ALT) in serum samples... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw cycle.N665730DPPM48 µL192 µL-20℃. Avoid freeze/thaw cycle.* This kit is suitable for human genomic DNA library construction with a starting template DNA input of 50 ng. We also have transposase library construction kits for human genomic DNA starting at 5 ng and 1 ng, so it is recommended to use different kits for different starting amounts of DNA in order to obtain higher quality libraries. Products IntroductionThis kit is developed for Illumina's high-throughput sequencing platform and provides the enzyme premix system and reaction buffer for genomic DNA library construction, including all components except PCR primers. Compared with the traditional library construction kits, this kit adopts the new transposase method for library construction, which can complete DNA fragmentation, end repair and junction reaction in one simple enzymatic reaction, significantly reducing the amount of template, reducing the number of experimental steps, and shortening the time of library construction; it adopts the high-fidelity DNA polymerase for library enrichment, and the preference-free PCR amplification can expand the coverage area of the sequence, which can be used for efficient and effective sequencing. The use of high-fidelity DNA polymerase for library enrichment and preference-free PCR amplification broadens the coverage area of the sequence and enables efficient preparation of DNA libraries for Illumina's second-generation sequencing platform. The kit is suitable for DNA libraries with a starting template of 50 ng, and all reagents in the kit have been subjected to strict quality control and functional validation to maximize the stability and reproducibility of library construction. Product Features ● DNA fragmentation and junction ligation in one step.● Ultra-fidelity amplification minimizes amplification-preferred steps.Provide your own instruments, kits and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use DNA purification and recovery kit by magnetic bead method.3. Library PCR primer kits: transposase method for second-generation sequencing multi-sample primer kits are recommended. 4. Anhydrous ethanol, deionized water (pH between 7.0 and 8.0).5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes. Tips: It is recommended to use high quality filter tips to prevent contamination of kits and library samples. Pre-experiment Preparation and Important Notes1. Avoid repeated freezing and thawing of reagents.2. PCR products are easily contaminated due to improper operation, resulting in inaccurate results. It is recommended to isolate the PCR reaction system preparation area from the PCR product purification area, and to use special pipettes to clean the experimental areas at regular intervals.3. Bead purification: the beads should be equilibrated to room temperature before use, all operations on the beads should be carried out at room temperature, 80% ethanol should be dispensed freshly, the beads should be rinsed and dried until the surface is free of liquid reflections and has a frosted appearance, insufficient drying of the beads will cause ethanol residue that will affect the subsequent experiments, and over-drying of the beads will affect the efficiency of DNA recovery.4. The kit is suitable for human genomic DNA library construction, if the DNA sample is a PCR product, it should be ensured that its length>.500 bp, since transposases do not work on DNA ends, it is recommended to extend the PCR product by 50-100 bp at each end of the PCR product to avoid low coverage of the ends for sequencing.Sample PreparationDNA purity requirements: A260/A280 = 1.8-2.0. Sample DNA: dissolve in ultrapure water. DNA Quantification: Too much or too little DNA will affect the quality of the library. It is recommended to use Nano to test the purity of the genomic DNA and then use Qubit to test the concentration of the genome (do not use any absorbance-based assay for template quantification).Schematic diagram of DNA banking processprocedureDNA fragmentation, junction reaction1. Add the following reagents to a 200 µl PCR tube: 2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:DNA should be purified immediately after the fragmentation reaction has been performed and the transposase is still in a high state of activity.to prevent smaller library fragments due to DNA over-fragmentation. Purification of fragmentation productsWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Add 50 µl of magnetic beads equilibrated to room temperature to the fragmentation product, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, then add 23 µlddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer 21 µl of supernatant to a new 200 µl PCR tube.PCR amplification Add the following reagents to the 200 µl PCR tube: Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:Selective recovery of library DNA fragmentsIt is recommended to use CombiVision Magnetic Beads DNA Purification and Recovery Kit for selective recovery of DNA fragments. When different sizes of DNA fragments are required, the amount of magnetic beads to be used is different, please refer to the attached table for the specific amount of magnetic beads to be used (if other brands of magnetic beads are used, you need to find out the optimal amount of magnetic beads to be used on your own).Note: Amplification products can also be fragment length sorted and purified using the Gum Recovery Kit. If there is no special requirement for library length distribution, the amplification products can also be purified without selective recovery of DNA fragments as described on page 6 of the manual.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Transfer the PCR product to a 1.5 ml centrifuge tube, rehydrate to 100 µl and add several volumes of magnetic beads equilibrated to room temperature, vortex for 5 seconds and let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, and carefully aspirate the supernatant and transfer it to a new 1.5 ml centrifuge tube.Note: Do not discard the top clear.4. Add several volumes of magnetic beads to the supernatant, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.5. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA.Note: Do not discard the beads.6. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.7. Repeat step 6 once.8. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 20 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.9. Remove the centrifuge tube from the magnetic rack, vortex and oscillate to completely resuspend the beads, and let stand at room temperature for 5 minutes. Leave brieflycentrifuge, place the tube on a magnetic rack until the solution is clear, and transfer the supernatant solution to a new centrifuge tube. Table: Suggested amount of magnetic beads for different segment selection recoveryLibrary DNA fragment purificationWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. 50 µl of magnetic beads equilibrated to room temperature were added to the PCR product, vortexed and shaken for 5 seconds, and then left to stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 25 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube.Library quality controlDetermination of library concentrationIn order to obtain high-quality sequencing results, accurate quantification of DNA libraries is required, and the first recommendation is to use Real-timePCR methods are used for absolute quantification of DNA libraries. Additionally, fluorescent dye methods such as the Qubit method or the fluorescent dye picogreen method can be used; do not use quantification methods based on absorbance measurements here. The following approximate formula can be used to convert the molar concentration of the DNA library. Average total length of librariesApproximate conversion formula Library fragment distributionThe prepared DNA libraries can be detected by agarose gel electrophoresis or Agilent 2100 Bioanalyzer.Range of segment length distributions... Read More | Product content R669871Component50 TStorageR669871ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669871B10×Reaction Buffer1mL-20℃. Avoid freeze/thaw cycle. R669871CBuffer DS30 mLRTR669871DBuffer GTL15 mLRTR669871EBuffer GL25 mLRTR669871FProteinase K12.5 mgRTR669871GProteinase K Product content R669871Component50 TStorageR669871ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669871B10×Reaction Buffer1mL-20℃. Avoid freeze/thaw cycle. R669871CBuffer DS30 mLRTR669871DBuffer GTL15 mLRTR669871EBuffer GL25 mLRTR669871FProteinase K12.5 mgRTR669871GProteinase K Storage Buffer1.25 mLRTR669871HBuffer RW140 mLRTR669871IBuffer RW2 (concentrate)11 mLRTR669871JRNase-Free Water10 mLRTR669871KSpin Columns RS with Collection Tubes50 setsRTR669871LRNase-Free Centrifuge Tubes (1.5 mL)50 EART Product IntroductionThis kit is suitable for effectively purifying total RNA from formalin fixed and paraffin embedded tissues. Suitable for extracting total RNA with improved purity from paraffin embedded tissues or sections less than 30mg. This kit does not require the use of phenol/chloroform extraction or isopropanol precipitation, and can complete the extraction of multiple samples within one hour. This product uses specially optimized lysis solution and protease K to release RNA from formalin fixed or tissue slice samples without overnight operation; After digestion, the sample is incubated at a higher temperature to remove the inhibitory effect caused by formalin cross-linking, effectively releasing RNA from tissue slices and avoiding endangering RNA integrity; The optimized buffer system allows RNA in the lysis solution to specifically bind to the silica gel adsorption membrane, while other pollutants can flow through the membrane; It can be effectively removed through rinsing steps, and the washed RNA can be directly used for experiments such as RT-PCR, Real Time PCR, and Western blot analysis.Self prepared reagents: anhydrous ethanol (newly opened or dedicated for RNA extraction), 10mM PBS (pH 7.4).Preparation and important precautions before the experiment1. Add 0.625ml Protein K Storage Buffer to Protein K to dissolve it and store at -20 ℃. The prepared Protein K should not be left at room temperature for a long time to avoid repeated freeze-thaw cycles, which may affect its activity.2. To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.3. After obtaining the sample, it should be fixed in 4% -10% formalin as soon as possible, with a suitable fixation time of 14-24 hours. Excessive time can lead to RNA breakage and affect downstream experiments.4. Ensure that the sample before embedding is thoroughly dehydrated, as residual formalin will inhibit the action of Protein K.5. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.Before use, please check if there is any crystallization or precipitation in Buffer GTL, Buffer GL, and Buffer DS. If there is any crystallization or precipitation, please dissolve Buffer GTL, Buffer GL, and Buffer DS again in a 56 ℃ water bath.Operation steps1. Sample processing1a. Paraffin embedded sample: Use a surgical knife to trim off excess paraffin from the tissue block, expose the tissue, and cut into 5-10 µ m thin slices.Attention: If the surface of the sample has already been exposed to air, please discard 2-3 pieces that come into contact with the air and do not use them.1b. Samples in fixed solutions such as formalin: Take approximately 20mg of the sample, cut it into small pieces, place it in a centrifuge tube, and add 500 µ 10mM PBS (PH7.4), vortex oscillation, centrifugation at 12000 rpm (~13400 × g) for 1 minute, discard the supernatant, repeat 3 times, and proceed directly to step 3.2. Choose option A or option B to remove paraffinOption AA1. Take approximately 1 × 1cm2 of slices (4-5 slices in total) and place them in a centrifuge tube (prepared by oneself), then add 500 slices µ L Buffer DS, vortex oscillation for 10 seconds. Incubate at 56 ° C for 3 minutes.Centrifuge at A2.12000 rpm for 2 minutes, be careful to discard the supernatant and avoid attracting sediment.Option BB1. Take approximately 4-5 slices of approximately 1 × 1 cm2 and place them in a centrifuge tube (self prepared). Add 1ml of xylene, cover the tube tightly, and vortex for 10 seconds.B2.Centrifuge at 12000 rpm for 2 minutes, be careful to remove the supernatant and avoid removing sediment.B3. Add 1ml of anhydrous ethanol, vortex and shake well. Centrifuge at 12000 rpm for 2 minutes, discard the supernatant, and be careful not to absorb or discard the sediment.B4. Open the tube cover and incubate at room temperature or up to 37 ° C for 10 minutes until there is no ethanol residue.3. Add 150µ L Buffer GTL, resuspended precipitation; Join 10µl Protein K, vortex oscillation mixing.4.Incubate at 56 ℃ for 15 minutes until the sample is completely dissolved. Incubate at 80 ℃ for 15 minutes. Short centrifugation allows the solution on the tube wall to be collected to the bottom of the tube.Note: 1) The purpose of this step is to repair nucleic acids denatured by formaldehyde. Incubating at a high temperature or for too long may cause RNA breakage, resulting in RNA fragments.2) The sample incubated at 56 ℃ can be placed at room temperature until the temperature of the water or dry bath reaches 80 ℃, and then the sample can be incubated at 80 ℃.5. Place on ice for 3 minutes, centrifuge at 12000 rpm for 15 minutes, transfer the supernatant to a new centrifuge tube, be careful not to suck sediment.6. Add 320 to the supernatant µ L Buffer GL, vortex oscillation thoroughly mixed.7. Join 720 µ Mix anhydrous ethanol thoroughly with vortex oscillation.Attention: After adding anhydrous ethanol, there may be a small amount of precipitate precipitation, but it does not affect subsequent operations.8. Add all the solutions obtained in step 7 to the spin columns RS that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Optional steps: If genomic DNA needs to be removed, the following steps can be followeda. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 1 minute, discard the waste liquid, and place the adsorption column back into the recovery manifold.b. Preparation of DNase I mixture: Take 52 µ Add 8 RNase Free Water to it µ 10 x Reaction Buffer and 20 µ DNase I (1U/ µ l) Mix well and prepare to a final volume of 80 µ The reaction solution of L.c. Add 80 µ l of DNase I mixture directly to the adsorption column and incubate at 20-30 ℃ for 15 minutes.d. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 1 minute, discard the waste liquid, and place the adsorption column back into the recovery manifold.9. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.10. Repeat step 9.Centrifuge at 11.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).12. Place the adsorption column in a new RNase free centrifuge tube, and add 20-50µl to the middle of the adsorption column in the air Place RNase Free Water at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -20 ℃.Note: 1) The volume of RNase Free Water should not be less than 20 µ l. Small volume affects the recovery rate. 2) If you want to increase RNA production, you can use 20-50 µ Repeat step 12 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 12... Read More |