| Description | DescriptionPhoto KitAlysis Starter Kit enables screening of 24 micro-scale simultaneous photocatalytic reactions with consistent and reproducible photon intensity. User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsComponents:Photo KitAlysis LED ControllerBlue LED DescriptionPhoto KitAlysis Starter Kit enables screening of 24 micro-scale simultaneous photocatalytic reactions with consistent and reproducible photon intensity. User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsComponents:Photo KitAlysis LED ControllerBlue LED Array (470 nm)Photo KitAlysis Reaction BlockTorque screwdriverSmall screwdriver to easily remove torqued screws after reaction is completeFeatures:Designed and tested by synthetic chemists.Controller provides repeatable milliamp selection for photon intensity0-30 mA variable LED output3 different LED options: blue (470 nm, included), green (527 nm, sold separately), and white (sold separately)Non-magnetic LED baseChemically resistant LED coverPTFE coated cablingDesigned to be used withPhoto KitAlysis High-Throughput Reaction Screening Kit(sold separately).Best when used withKitAlysis Benchtop Inertion Box(sold separately)... Read More | Products contentN665993Component240 TStorageN665993AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/ Thaw cycle.N665993BIndex N925-N948 Primers for Illumina24×10 µL-20℃. Avoid freeze/ Thaw cycle. Products Introduction This kit is a companion kit to the transposase-Products contentN665993Component240 TStorageN665993AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/ Thaw cycle.N665993BIndex N925-N948 Primers for Illumina24×10 µL-20℃. Avoid freeze/ Thaw cycle. Products Introduction This kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Illumina platform library construction. Each kit contains one N5 primer and 24 N7 primers, which can be used to prepare 24 different single-ended Index libraries. All reagents provided in the kits have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes;Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers. ProcedureFor the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol.Index N501 Primer for IlluminaIndex N901-N996 Primer for Illumina... Read More | Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for extracting total DNA from fecal samples, including the total DNA of cells, bacteria, parasites, and viruses in the samples, as well as samples containing high concentrations of PCR reaction inhibitors. This product can process up to 300 mg of fecal samples and purify to obtain mainly 20-30 kb DNA fragments. The purification process does not require toxic solvents such as phenol or chloroform, and does not require ethanol precipitation. High purity DNA can be obtained within one hour. This reagent kit adopts a unique buffering system to efficiently bind DNA from the lysis solution to the adsorption column. At the same time, protein impurities and other organic compounds that inhibit downstream reactions in feces can flow through the membrane. Inhibitors of PCR and enzyme reactions, as well as residual impurities, can be effectively removed through two washing steps. Finally, high-purity DNA can be obtained by washing with low salt buffer or water. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, Real Time PCR, library construction, Southern Blot, and molecular labeling.Preparation and important precautions before the experiment1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to Buffer GW1 and GW2 according to the instructions on the reagent bottle label.3. Before use, please check whether there is crystallization or precipitation in Buffer SL and Buffer GL. If there is crystallization or precipitation, please dissolve Buffer SL and Buffer GL again in a 56 ℃ water bath.4. If downstream experiments are sensitive to RNA contamination, 4 can be added after adding Buffer SL µ RNase A of DNase Free (100 mg/ml) is not provided in this kit. If needed, it can be ordered separately from our company, item number: S665549Operation steps1. Take a fecal sample of 100-300 mg and place it in a centrifuge tube (provided by oneself).2. Add 1 ml of Buffer SW and vortex for 3-5 minutes to evenly disperse the sample in the solution. Centrifuge at 12000 rpm (~13400 × g) for 1 minute and discard the supernatant.3. Add 1 ml of Buffer SL and vortex for 3-5 minutes to evenly disperse the sample in the solution. Take a water bath at 65 ℃ for 20 minutes and vortex for 15 seconds every 5 minutes. Note: To remove RNA, add 4 after completing the above steps µ RNase A solution (product number: CW0601S) with a concentration of 100 mg/ml, shake well and let stand at room temperature for 5-10 minutes.4.Centrifuge at 2000 rpm for 3 minutes and transfer the supernatant to a new centrifuge tube (provided by oneself).5. Add an equal volume of Buffer GL to the supernatant, invert and mix 15-25 times, and leave on ice for 5 minutes. Centrifuge at 12000 rpm for 5 minutes. Attention: At this time, the liquid may be in a transparent or turbid state, which does not affect the experiment. 6. Add the supernatant obtained in step 5 to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. 8. Repeat step 7.9. Add 500 to the adsorption column µ Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.10.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self provided) and add 50-100 drops of suspended droplets to the middle of the adsorption column µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency will be reduced2) Incubating at room temperature for 5 minutes before centrifugation can increase yield.3) Use an additional 50-100 µ Further washing with buffer GE or sterilized water can increase yield.4) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 11 back onto the adsorption membrane and repeat step 11; It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with buffer GE or sterilized water.5) DNA stored in water can be affected by acidic hydrolysis. If long-term storage is required, it is recommended to elute with Buffer GE and store at -20 ℃.6) The residual trace PCR inhibitors in the genomic DNA template may have adverse effects on the PCR reaction, which can be solved by diluting DNA by 2-10 times... Read More | Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Collection Tubes50 sets 200 setsRTS666146HCentrifuge Tubes (1.5 mL)50 EA200 EARTProductsThis kit provides a simple and rapid method for the isolation and purification of total DNA from buccal swab samples. The kit adopts a silica matrix membrane that can specifically bind DNA and a unique buffer system to adsorb DNA efficiently and specifically, and 0.5-3.5 µg of genomic DNA can be obtained from each swab, and the extracted DNA fragments are large, pure and of stable and reliable quality. It is suitable for enzyme digestion, PCR, library construction, Southern hybridization and other experiments.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.2. If precipitation is found in Buffer GL before use, dissolve Buffer GL in a 56°C water bath.3. All centrifugation steps can be performed at room temperature.4. Sampling: Use a buccal swab to wipe the inside of the mouth 6 times, dry for 2 hours and store. To ensure that the sample is not contaminated by food or drink, do not eat or drink for 30 minutes before sampling.Procedure1. The swab of the buccal swab was cut from the rod with scissors and placed in a 2mL centrifuge tube (supplied) and 400µL Buffer GR was added.Note: For genomic DNA without RNA contamination, add 4 µL of RNase A solution at a concentration of 100 mg/ml and shake to mix.2. Add 20 µL of Proteinase K and 400 µL of Buffer GL, immediately vortex and shake for 15 seconds and mix thoroughly.Note: Mix well immediately after adding Buffer GL; do not add Proteinase K directly to Buffer GL for use.3.56°C for 10 minutes and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.4. Add 400 µL of anhydrous ethanol, vortex and shake to mix thoroughly, and centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube.Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.5. Add the solution and precipitate obtained in the previous step to the Spin Columns DS in two batches of up to 700 µL at a time into the collection tube. centrifuge the column at 12,000 rpm (∼13,400 × g) for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.6. Add 500 µL of Buffer GW1 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.7. Add 500 µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge the column at 12,000 rpm for 3 minutes, pour off the waste liquid in the collection tube, and put the column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 1 minute and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new 1.5 mL centrifuge tube, add 50 µL of Buffer GE or sterilized water to the middle of the adsorption column overhanging the column, let stand at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store at -20℃.Attention:(1) If the downstream experiment is sensitive to pH or EDTA, it can be eluted with sterilized water. The pH value of the eluent has a great influence on the elution efficiency. If the eluent is made of water, the pH value should be 7.0-8.5 (the pH value of water can be adjusted to this range by using NaOH), and the elution efficiency is not high when the pH value is lower than 7.0.2) For long-term storage, it is recommended to elute with Buffer GE and store at -20°C... Read More | Inquire |