| Description | DescriptionWhite LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatableDescriptionWhite LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatable milliamp selection for photon intensity (sold seperately)0-30 mA variable LED outputNon-magnetic LED baseChemically resistant LED coverPTFE coated cablingPhoto Kitalysis Starter Kitrequired for operation (sold separately). Best when used withKitAlysis Benchtop Inertion Box(sold separately)... Read More | Annexin V ( annexin-V ) is a Ca2 + dependent phospholipid binding protein with a molecular weight of 35-36 KD, which can selectively bind to phosphatidylserine ( PS ). Phosphatidylserine ( PS ) is mainly distributed in the inner side of the cell membrane, that is, the side adjacent to the cytoplasm.Annexin V ( annexin-V ) is a Ca2 + dependent phospholipid binding protein with a molecular weight of 35-36 KD, which can selectively bind to phosphatidylserine ( PS ). Phosphatidylserine ( PS ) is mainly distributed in the inner side of the cell membrane, that is, the side adjacent to the cytoplasm. In the early stage of apoptosis, different types of cells will turn phosphatidylserine out to the cell surface and expose to the extracellular environment. At this time, using Annexin V labeled with fluorescent protein PE, that is, Annexin V-PE, combined with phosphatidylserine ( PS ), the eversion of phosphatidylserine, an important feature of apoptosis, can be directly detected by flow cytometry. Normal cells will not be stained by Annexin V-PE, apoptotic or necrotic cells will be stained by Annexin V-PE. Annexin V-PE can be used in combination with partially non-permeable nuclear dye ( 7-AAD / PI ) to distinguish cells at different stages of apoptosis. RedNucleus II provided in this kit is a far-red dye that belongs to an anthraquinone compound and cannot penetrate the intact cell membrane of living cells and early apoptotic cells. It is non-permeable, but can quickly stain the nucleus / dsDNA in dead and permeable cells. RedNucleus II is an ideal substitute for propidium iodide ( PI ) and 7-AAD.Combined with Annexin V-PE, it has better spectral characteristics without compensation regulation : it is not excited by ultraviolet light and does not overlap with PE / PE homologues, so it can be combined with FITC, PE and purple fluorescent dyes for multicolor analysis. When combined with Annexin V-PE, RedNucleus II was excluded from living cells and early apoptotic cells, while late apoptotic cells and dead cells were double-positive for Annexin V-PE and RedNucleus II. Annexin V-PE / RedNucleus II apoptosis detection kit can be detected by flow cytometry or other fluorescence detection equipment. Components: Components A598354(10T) A598354(50T) A598354(100T) A. 1×Annexin V Combining buffer solution 10 mL 50 mL 50 mL×2 B. Annexin V-PE 50 µL 250 µL 500 µL C. RedNucleus II 100 µL 500 µL 1 mLProduct parameters:Annexin v-pe:ex/em=488/578 nmrednucleus ii:ex/em=635/695 NMUsage method:1. Experimental design: Blank tube: Negative control group cells, without Annexin V-PE/RedNucleus II. Used to regulate voltage.Single staining tube: Positive control group cells were treated with Annexin V-PE alone/RedNucleus II alone. Used for adjusting compensation.Detection tube: Add Annexin V-PE/RedNucleus II to the processed cells. After adjusting the voltage compensation using blank tubes and single dye tubes, obtain the required flow data.2. Collect cells(1) For suspended cells:a. After inducing cell apoptosis, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, collect the cells, gently resuspend the cells in PBS, and count them.Note: PBS resuspension cannot be omitted. The process of PBS resuspension also serves to wash cells, ensuring the subsequent binding of Annexin V-PE.b. Take 5 × 104-1 × 105 resuspended cells, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and add 100 µ L of 1 × Annexin V binding buffer to gently resuspend the cells. c. Add 5 µ L Annexin V-PE and mix gently.d. Add 5 µ L of RedNucleus II staining solution and mix gently.e. Incubate at room temperature (20-25 º C) in the dark for 15 minutes. Aluminum foil can be used to avoid light. During the incubation process, cells can be resuspended 2-3 times to improve staining efficiency.(2) For adherent cells:a. Suck out the cell culture medium into a suitable centrifuge tube, wash the adherent cells with PBS once, and add an appropriate amount of trypsin cell digestion solution (without EDTA) to digest the cells. Incubate at room temperature until gently blowing can remove the trypsin cell digestion solution when the adherent cells are blown down. Overdigestion of pancreatic enzymes should be avoided.Note: For adherent cells, the trypsin digestion step is crucial. If the trypsin digestion time is too short, cells need to be blown hard to detach, which can easily cause damage to the cell membrane and lead to false positives of cell necrosis; If the digestion time is too long, it can also cause cell membrane damage and false positives of cell necrosis, and even affect the binding of phosphatidylserine and Annexin V-PE on the cell membrane, thereby interfering with the detection of cell apoptosis.b. Add the cell culture medium collected in the previous step, gently blow down the cells, transfer them to a centrifuge tube, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, collect the cells, gently resuspend the cells in PBS and count them.Note: Adding the cell culture medium from the previous step is very important. On the one hand, it can collect cells that have already been suspended and undergone apoptosis or necrosis. On the other hand, the serum in the cell culture medium can effectively inhibit or neutralize residual trypsin. The residual trypsin will digest and degrade the subsequently added Annexin V-PE, leading to staining failure.c. Take 5 × 104-1 × 105 resuspended cells, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and add 100 µ L of 1 × Annexin V binding buffer to gently resuspend the cells. d. Add 5 µ L Annexin V-PE and mix gently.e. Add 5 µ L of RedNucleus II staining solution and mix gently.f. Incubate at room temperature (20-25 º C) in the dark for 15 minutes. Aluminum foil can be used to avoid light. During the incubation process, cells can be resuspended 2-3 times to improve staining efficiency.3. Result analysis:(1) Flow cytometry detection:a. After incubation, 400 µ L of 1 × Annexin V binding buffer can be directly added to resuspend the cells, and immediately detected on the machine. Annexin V-PE is excited by 488 nm/566 nm laser, and the fluorescence emission spectrum is detected at 578 nm (BL2 (FL2)/YL1 channel), while the RedNucleus II channel emission spectrum is approximately at 695 nm (RL1 (FL4) channel).b. On the scatter plot of the bivariate flow cytometer, live cells are shown in the lower left quadrant, which is (Annexin V-PE -/RedNucleus II -); The lower right quadrant represents early apoptotic cells, which are (Annexin V-PE+/RedNucleus II -); The upper right quadrant represents necrotic and late stage apoptotic cells, which are (Annexin V-PE+/RedNucleus II+); The upper left quadrant displays naked nuclear cells, which are (Annexin V-PE -/RedNucleus II+).(2) Fluorescence microscopy detection:a. Centrifuge at 1000 rpm for 5 minutes, collect cells, and gently resuspend them in 400 µ L of 1 × Annexin V binding buffer. Transfer the cells to a 96 well plate and settle for a moment or perform cell smear, then observe under a fluorescence microscope.b. Annexin V-PE is compatible with PE filters. RedNucleus II can use a far red long pass filter.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. to reduce the process of apoptosis, the incubation process can be operated on ice, but the incubation time should be extended to at least 30 min. 3. as apoptosis is a rapid process, it is recommended that samples be analyzed within 1 h after staining. 4. for adherent cells, digestion is a key step. If there are floating cells when adherent cells induce apoptosis, the floating cells and adherent cells should be collected and stained. Handle adherent cells with care to avoid artificial damage to cells. The trypsin digestion time is too short, and the cells need to be blown hard to fall off, which is easy to cause damage to the cell membrane and excessive intake of rednucleus II; If the digestion time is too long, the cell membrane is also prone to damage, and even affect the binding of phosphatidylserine and annexin v-pe on the cell membrane. When digesting, spread pancreatin on the bottom of the well plate, fully contact the pancreatin with the cells when shaking gently, then pour out most of the pancreatin, use the remaining small amount of pancreatin to digest for a period of time, and terminate when the gap between cells increases and the bottom of the bottle is spotted. Try not to use EDTA in the digestive juice, which will affect the binding of annexin V to PS. 5. after the adherent cells are digested with trypsin, it is recommended to stain after recovering in the optimal culture conditions and medium for about 30 min to avoid false positives. 6. in order to avoid losing cells when washing cells, you can use a large tip over a small tip to aspirate. 7. the optimal concentration of dye is determined by the specific experimental requirements. 8. fluorescent dyes have quenching problems. Please try to avoid light during storage and use to slow down fluorescence quenching. 9. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Early apoptosis detection, annexin V Kit... Read More | Products B669892Component50 TStorageB669892ABuffer RCL3×260 mL2-8℃B669892BBuffer GR25 mLRTB669892CBuffer GL25 mLRTB669892DBuffer GW1 (concentrate)13 mLRTB669892EBuffer GW2 (concentrate)15 mLRTB669892FBuffer GE15 mLRTB669892GProteinase K50 mgRTB669892HProteinase K Storage Buffer5 Products B669892Component50 TStorageB669892ABuffer RCL3×260 mL2-8℃B669892BBuffer GR25 mLRTB669892CBuffer GL25 mLRTB669892DBuffer GW1 (concentrate)13 mLRTB669892EBuffer GW2 (concentrate)15 mLRTB669892FBuffer GE15 mLRTB669892GProteinase K50 mgRTB669892HProteinase K Storage Buffer5 mLRTB669892ISpin Columns DL with Collection Tubes50 setsRTProductsThis kit is suitable for the extraction of total DNA, including genomic DNA, mitochondrial DNA and viral DNA, from fresh or frozen whole blood (blood samplestreated with anticoagulants such as citrate, EDTA or heparin), plasma, serum, haematocrit brown and yellow layers, bone marrow, cell-free body fluids, etc. Theproduct can process 1-5 ml of whole blood, and can be purified to obtain sizes rangingfrom 100bp to 50kb. The purified DNA is of high yield and good quality, with maximumremoval of proteins, pigments, lipids and other inhibitory impurities, and can bedirectly used in PCR, fluorescence quantitative PCR, enzyme digestion and SouthernBlot.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. Add 5ml Proteinase K Storage Buffer to Proteinase K to dissolve it, and storeit at -20℃. Do not leave the prepared Proteinase K at room temperature for a longtime, and avoid repeated freezing and thawing to avoid affecting its activity.2. Repeated freezing and thawing of the sample should be avoided, as this may resultin smaller DNA fragments and a decrease in the amount of extracted DNA. 3.This kit can extract up to 1-5 ml of whole blood samples, if you need to extracta large number of blood samples, please use the blood genome non-column extractionkit. 4. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to theinstructions on the label of the reagent bottle before first use.5. Please check Buffer GL for crystallization or precipitation before use, if thereis any crystallization or precipitation, please put it in 56℃water bath to re-dissolve.6. If the downstream experiments are sensitive to RNA contamination, 4µl of DNaseFree RNase A (100mg/ml) can be added, RNase A is not provided in the kit, and canbe ordered separately from our company if needed.7. The Buffer RCL in the kit cannot be used further after turbidity.procedure1. Add 1-5 ml of blood sample to a centrifuge tube (supplied) and add 3 times thevolume of Buffer RCL and gently vortex or invert to mix.2. Centrifuge at 3000 rpm (~900 x g) for 10 minutes and carefully aspirate thesupernatant.3. Add 400 µl Buffer GR to the precipitate and resuspend the precipitate. Note: If the downstream assay is sensitive to RNA, add 4 µl of RNase A (100 mg/ml)solution, shake for 15 seconds, and leave at room temperature for 5 minutes.4. For 1-2 ml blood sample extraction, add 40µl Proteinase K to the above solutionand mix well; for 2-5 ml blood sample extraction, add 100µl Proteinase K to theabove solution and mix well.5. Add 400 µl of Buffer GL, mix upside down 15 times, and vigorously vortex andshake for at least 1 minute. Note: Do not add Proteinase K directly to Buffer GL.6. Incubate at 70°C for 10 minutes, during which time mixing was inverted severaltimes.Note: 1) If the solution is not completely clear, add appropriate amount of Proteinase K and incubate. Extend the incubation time until the solution is completely clear. 2) The yield of DNA has been maximized by 10 minutes of incubation, and continuedprolongation of the incubation time has no effect on DNA yield or purity.7. Add 400 µl of anhydrous ethanol and mix upside down 10 times. Centrifuge brieflyto concentrate the liquid on the walls and cap to the bottom of the tube.8. Add all of the solution obtained in the previous step to the Spin Columns DL inthe collection tube. If the solution cannot be added all at once, transfer it severaltimes. centrifuge at 12,000 rpm (~13,400 x g) for 1 minute, pour off the waste liquidfrom the collection tube, and put the column back into the collection tube.9. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanolis added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquidin the collection tube, and put the adsorption column back into the collection tube.Note: It is recommended that step 9 be repeated if the sample being extracted isthe blood genome of a species such as mice or monkeys from which hemoglobin isdifficult to remove.10. Add 500 µl Buffer GW2 to the adsorption column (check that anhydrous ethanolis added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquidin the collection tube, and put the adsorption column back into the collection tube.Note: Step 10 can be repeated if further DNA purity is required.11. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in thecollection tube. Leave the adsorption column at room temperature for several minutesto dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorptioncolumn, which can interfere with subsequent enzymatic reactions (digestion, PCR,etc.)12. Place the adsorption column in a new centrifuge tube, add 50-200 µl of BufferGE or sterilized water to the middle of the adsorption column overhanging the column,leave it at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute,collect the DNA solution, and store the DNA at -20℃.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on theelution efficiency, if water is used as the eluent should ensure that its pH is7.0-8.5 (you can use NaOH to adjust the pH of the water to this range), and the elutionefficiency is not high when the pH is lower than 7.0.2) Incubation at room temperature for 5 minutes prior to centrifugation increasesyield.3) Re-elution with an additional 50-200 µl Buffer GE or sterilized water can increase the yield.4) If the final concentration of DNA is to be increased, the DNA eluate obtainedin step 12 can be re-spiked onto the adsorbent membrane and centrifuged at 12,000rpm. 1min; if the elution volume is less than 200µl, the final concentration of DNA canbe increased, but the total yield may be reduced. If the amount of DNA is less than1 µg, elution with 50 µl Buffer GE or sterilized water is recommended.5) Because DNA preserved in water is subject to acidic hydrolysis, for long-termstorage, it is recommended that it be eluted with Buffer GE and stored at -20℃... Read More | This kit is suitable for extracting total RNA from fresh whole blood (blood samples treated with anticoagulants such as citrate, EDTA, or heparin). It can process up to 1.5 ml of whole blood and elute to obtain high-purity RNA with a molecular weight greater than 200 bp. Multiple samples can be This kit is suitable for extracting total RNA from fresh whole blood (blood samples treated with anticoagulants such as citrate, EDTA, or heparin). It can process up to 1.5 ml of whole blood and elute to obtain high-purity RNA with a molecular weight greater than 200 bp. Multiple samples can be completed simultaneously within 1 hour. This product does not require the ultra centrifugation step of CsCl purification and LiCl or ethanol precipitation. It does not contain toxic solvents such as phenol or chloroform. The purified RNA effectively removes enzyme inhibitors and pollutants such as heme and heparin. It can be directly used in various molecular biology routine experiments, such as RT-PCR, Northern Blot, Dot Blot, in vitro translation, and so on.Self prepared reagents: β- Mercaptoethanol, 70% ethanol (prepared with water without RNase), anhydrous ethanol. R666034 Component 50 T Storage R666034A Buffer RBL (10×) 60 mL RT R666034B Buffer RL 35 mL RT R666034C Buffer RW1 40 mL RT R666034D Buffer RW2 (concentrate) 11 mL RT R666034E RNase-Free Water 10 mL RT R666034F Spin Columns FL with Collection Tubes 50 sets RT R666034G Spin Columns RM with Collection Tubes 50 sets RT R666034H RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RT Preparation and important precautions before the experimentTo prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The sample should avoid repeated freezing and thawing, otherwise it will affect the yield and quality of RNA extraction. The sample can be stored in Buffer RL at -70 ℃ for one month.3. Before use, please check if there is any crystallization or precipitation in the Buffer RL. It can be dissolved again in a 56 ℃ water bath. Please add Buffer RL before use β- Mercaptoethanol, with a final concentration of 1%. Add 10 to 1 ml Buffer RL µ L β- Mercaptoethanol. join β- The buffer RL room temperature of mercaptoethanol can be stored for one month.4. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. This reagent kit cannot be used for RNA extraction from frozen blood samples with anticoagulants added.6.10 × Buffer RBL needs to be diluted 10 times with water without RNase before use, and then stored at 2-8 ℃ after dilution.7. If downstream experiments are highly sensitive to DNA, it is recommended to treat RNA with DNase I that does not contain RNase.8. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps1. Add 5 times the volume of 1 x Buffer RBL to fresh anticoagulant whole blood samples of 0.5-1.5 ml (please dilute 10 x Buffer RBL with RNase free water before use), gently vortex or invert and mix well. Incubate on ice for 10-15 minutes, mix twice during the incubation process.Attention: During the incubation process, the cloudy suspension will become transparent, indicating that red blood cells have been lysed. If necessary, the incubation time can be extended to 20 minutes. 2. Centrifuge at 4 ℃, 2100 rpm (~400 × g) for 10 minutes, and carefully discard the supernatant.3. Add 2 times the volume of the blood sample to the above precipitate with 1 x Buffer RBL (please dilute 10 x Buffer RBL with RNase free water before use), gently vortex, and resuspend the precipitate thoroughly. 4. Centrifuge at 4 ℃ and 2100 rpm for 10 minutes, carefully and thoroughly remove the supernatant.Note: This step must completely remove the supernatant, otherwise it will affect the lysis and lead to a decrease in RNA production.5. Add Buffer RL to the precipitate (check if it has been added before use β- Mercaptoethanol, 0.5-1.5 ml of blood sample added to 600 µ L Buffer RL, or less than 0.5 ml of blood sample added to 350 µ L Buffer RL, mix well.6. Transfer the obtained liquid to the spin columns FL that have been loaded into the collection tube, centrifuge at 12000 rpm (~13400 × g) for 2 minutes, collect the filtrate, and discard the filter column.7. Add 1 volume (600) to the obtained filtrate µ L or 350 µ l) Mix 70% ethanol (prepared without RNase water) well.Attention: Adding ethanol may cause precipitation and will not affect subsequent experiments.8. Add all the solution obtained in the previous step to the spin columns RM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred in multiple batches. Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.9. Add 700 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.Optional steps: If conducting RNA experiments that are highly sensitive to trace amounts of DNA, replace step 9 with the following steps.1) Add 350 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.2) Preparation of DNase I mixture: Take 70 µ Reaction Buffer and 10 µ L DNase I storage solution, gently mix and prepare to a final volume of 80 µ The reaction solution of L.Attention: The above system is configured according to our company's DNase I (D665537) reaction system. Please refer to the corresponding manual for other company products.1) Add 350 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.2) Preparation of DNase I mixture: Take 70 µ Reaction Buffer and 10 µ L DNase I storage solution, gently mix and prepare to a final volume of 80 µ The reaction solution of L.Attention: The above system is configured according to our company's DNase I (D665537) reaction system. Please refer to the corresponding manual for other company products.3) Add 80 µ l of the prepared DNase I reaction solution directly to the adsorption column and incubate at 20-30 ℃ for 15 minutes.4) Add 350 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.10. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 15 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.11. Repeat step 10. 12. Centrifuge at 12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).13. Place the adsorption column in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 13 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 13... Read More | Products contentProducts IntroductionThis kit is suitable for simple, rapid and efficient isolation and purification of DNA/RNA from whole blood, tissue homogenates, swabs, serum, plasma and other cell-free body fluids, etc. The unique buffer system enables the viral nucleic acids in the lysate to Products contentProducts IntroductionThis kit is suitable for simple, rapid and efficient isolation and purification of DNA/RNA from whole blood, tissue homogenates, swabs, serum, plasma and other cell-free body fluids, etc. The unique buffer system enables the viral nucleic acids in the lysate to bind to the silica gel centrifugal adsorbent columns in a highly efficient manner, and the viral nucleic acids obtained are of high purity and stable quality, free of protein, nuclease and other impurities, and can be used in a variety of routine operations, including PCR, fluorescence quantitative PCR and other experiments. It can be used for a variety of routine operations, including PCR, fluorescence quantitative PCR and other experiments.Bring your own instrumentsThermostatic mixer.Pre-experiment Preparation and Important Notes1. Read these instructions carefully before experimenting.2. If Proteinase K is to be stored for a long period of time, please keep it at -20℃.3. Check Buffer RLC for crystallization or precipitation prior to use, and if crystallization or precipitation occurs, redissolve Buffer RLC in a 56°C water bath.4. Pre-treatment of tissue samples: Take 20 mg of tissue samples into 1.5 mL centrifuge tubes (self-provided), add 500 µL of Buffer RLC, and after the tissue homogenizer breaks up, centrifuge the samples for 1 minute at 12,000 rpm (~13,400×g), and take 200 µL of supernatant as samples. procedure1. Take a 1.5 mL centrifuge tube (provided), add 500 µL of Buffer RLC, 200 µL of sample, 20 µL of Proteinase K, vortex for 5 s, and then place it in a thermostatic mixer at 1200 rpm for 10 min at room temperature. Note: For wet swab samples, 200 µL of sample was taken after sufficiently shaking and mixing. Note: For wet swabs, 200 µL was taken from the sample after it was soaked in 400 µL of saline, shaken and mixed thoroughly for 5 minutes, and then centrifuged at 12,000 rpm for 1 minute, and 200 µL was taken for extraction.2. Instantly remove the centrifuge tube and add the solution from step 1 to the Spin Columns DM in the collection tube. centrifuge at 12,000 rpm (~13,400 x g) for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.3. Add 500 µL of Buffer PGWT to the adsorbent column, centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.4. Add 500 µL of Buffer GWT2 to the adsorbent column, centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.5. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Place the adsorption column at room temperature for 2 minutes and allow to dry.6. Place the column in a new collection tube (RNase-Free Centrifuge Tube), add 40-100 µL of RNase-Free Water to the center of the column membrane, let it stand at room temperature for 2 minutes, and then centrifuge at 12,000 rpm for 1 minute to collect the nucleic acid solution. Store at -80℃ for a long time... Read More |