| Description | EndoFree Plasmid Midi Kit Cat No. Component Size(50T) Storage E665631A Buffer P1 30 mL RT E665631B Buffer P2 30 mL RT E665631C Buffer E3 30 mL RT E665631D Buffer PS 15 mL RT E665631E Buffer PW (concentrate) 10 mL RT E665631F Endo-free Buffer EB 10 mL RTEndoFree Plasmid Midi Kit Cat No. Component Size(50T) Storage E665631A Buffer P1 30 mL RT E665631B Buffer P2 30 mL RT E665631C Buffer E3 30 mL RT E665631D Buffer PS 15 mL RT E665631E Buffer PW (concentrate) 10 mL RT E665631F Endo-free Buffer EB 10 mL RT E665631G RNase A (10 mg/mL) 600 µL RT E665631H Buffer ER 8 mL RT E665631I CWBlue 300 µL RT E665631J Spin Columns DL with Collection Tubes 50 EA RT E665631K Endo-Remover FM with Collection 50 EA RTProduct Introduction:Endotoxins are a common pollutant in plasmid extraction. Due to the high sensitivity of eukaryotic cells to endotoxins, the presence of endotoxins in plasmids can greatly reduce the transfection efficiency of eukaryotic cells. This reagent kit provides a simple, fast, and efficient new method for extracting endotoxin free plasmids. The extracted plasmids can remove endotoxins to the maximum extent possible and effectively remove contamination of genomic DNA, RNA, proteins, and other substances. This reagent kit is suitable for extracting 5-15mL of bacterial solution. On the basis of alkaline lysis of cells, it efficiently and specifically binds plasmid DNA through a new silicon-based membrane. Each adsorption column can adsorb up to 100 µ The plasmid DNA of g is effectively removed using a special buffer system and endotoxin removal filter column, effectively removing impurities such as endotoxins and proteins. The plasmid obtained from this kit has high purity and stable quality, making it particularly suitable for cell transfection. It can also be used for downstream experiments such as DNA sequencing, PCR, PCR based mutations, in vitro transcription, transformed bacteria, and endonuclease digestion.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1. All components can be stably stored in a dry, room temperature (15-30 ℃) environment for 1 year, and can be stored at 2-8 ℃ for longer periods of time. Buffer P1 with RNase A added can be stably stored at 2-8 ℃ for 6 months.2. Before the first use, add all RNase A solution to Buffer P1, mix well, and store at 2-8 ℃. Before use, let it sit at room temperature for a period of time. After returning to room temperature, use.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer P2 and Buffer E3. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. Be careful not to come into direct contact with Buffer P2 and Buffer E3, and immediately cover them tightly after use.6.The amount and purity of plasmid extraction are related to factors such as bacterial culture concentration, strain type, plasmid size, and plasmid copy number.Operation steps:1. Take 5-15 mL of overnight cultured bacterial solution and add it to a centrifuge tube (self provided). Centrifuge at 13000 rpm (~16200 × g) for 1 minute to collect bacteria, and try to discard all the supernatant as much as possible.2. Add 500 to the centrifuge tube containing bacterial sediment µ L Buffer P1 (please check if RNase A has been added first), mix thoroughly with a pipette or vortex oscillator, and suspend bacterial precipitation. Attention: If the bacterial blocks are not thoroughly mixed, it will affect the cracking effect, resulting in low extraction amount and purity.3. Add 500 to the centrifuge tube µ L Buffer P2, gently invert and mix 8-10 times, allowing the bacterial cells to fully lyse. Leave at room temperature for 3-5 minutes. At this point, the solution should become clear and viscous. Attention: Mix gently and do not shake vigorously to avoid interrupting genomic DNA and mixing genomic DNA fragments in the extracted plasmid. If the solution does not become clear, it indicates that the bacterial count may be too high and the lysis may not be complete. The bacterial count should be reduced.4. Add 500 to the centrifuge tube µ L Buffer E3, immediately invert and mix 8-10 times until white flocculent precipitates appear. Let it stand at room temperature for 5 minutes. Centrifuge at 13000 rpm for 5 minutes, extract the supernatant, and add it to the filter column (Endo Remove FM) (already loaded into the collection tube). Centrifuge at 13000 rpm for 1 minute to filter, then transfer the filtrate from the collection tube to the centrifuge tube (self provided). Attention: 1) After adding Buffer E3, it should be immediately mixed to avoid local precipitation. 2) The maximum volume of the adsorption column is 750 µ L. So please filter the supernatant twice and mix it in the same self provided centrifuge tube.5. Add 450 to the filtrate µ Mix L isopropanol upside down.6. Column balance: Add 200 to the spin columns DL that have been loaded into the collection tube µ L Buffer PS, centrifuge at 13000 rpm for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Transfer the mixed solution of filtrate and isopropanol from step 5 to an equilibrium adsorption column (already loaded into a collection tube). 8.13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. Attention: The maximum volume of the adsorption column is 750 µ L. So the solution obtained in step 5 is divided multiple times and passed through the column. 9. Add 750 to the adsorption column µ L Buffer PW (please check if anhydrous ethanol has been added first), centrifuge at 13000 rpm for 1 minute, and discard the waste liquid in the collection tube.10. Place the adsorption column back into the recovery manifold and centrifuge at 13000 rpm for 1 minute.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self provided)... Read More | Inquire | Product content:D665967Component200 TStorageD665967ABuffer PB120 mLRTD665967BBuffer PS60 mLRTD665967CBuffer PW (concentrate)25 mLRTD665967DBuffer EB30 mLRTD665967ESpin Columns DM with Collection Tubes200 EART Product Introduction: This reagent kit adopts a new silicon-based membrane technology and Product content:D665967Component200 TStorageD665967ABuffer PB120 mLRTD665967BBuffer PS60 mLRTD665967CBuffer PW (concentrate)25 mLRTD665967DBuffer EB30 mLRTD665967ESpin Columns DM with Collection Tubes200 EART Product Introduction: This reagent kit adopts a new silicon-based membrane technology and reagent formula. Through a rapid and simple three-step process of binding, washing, and elution, 100 bp-10 kb DNA fragments can be purified and recovered from PCR products or enzyme reaction solutions (enzyme cutting, linking, probe labeling, etc.). Each adsorption column can adsorb up to 10 kb of DNA fragments µ G DNA, while minimizing impurities such as primers, oligonucleotides, enzymes, etc. The purified and recovered DNA has high purity and concentration, good integrity, and high recovery rate, and can be directly used for molecular biology experiments such as sequencing, linking and transformation, labeling, and in vitro transcription.Self prepared reagent: anhydrous ethanol.Preparation and important precautions before the experiment:1. All components can be stably stored in a dry, room temperature (15-30 ℃) environment for 1 year, and can be stored at 2-8 ℃ for longer periods of time. When the solution is stored at low temperature, it should be left at room temperature for a period of time before use, and then restored to room temperature before use.2. This reagent kit can selectively recover all DNA fragments from the solution. If you need to selectively recover specific fragments while removing other fragments of different sizes, please choose our company's gel recovery reagent kit.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in the Buffer PB. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. The recovery efficiency is related to the initial amount of DNA and the elution volume. The smaller the initial amount, the smaller the elution volume, and the lower the recovery rate.6. All centrifugation steps can be performed at room temperature.Operation steps:1. Estimate the volume of DNA reaction solution, add 5 times the volume of Buffer PB, and mix thoroughly (without removing paraffin or mineral oil).Note: 1) If the DNA reaction system is 50 µ l (excluding paraffin oil volume), add 250 µ l Buffer PB.2) After adding Buffer PB, check the pH value of the solution. If the pH value is greater than 7.5, add 10-30 to it µ 3 M sodium acetate (pH 5.0) was used to adjust the pH value to 5-7.2. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ Centrifuge at 13000 rpm (~16200 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.3. Add the solution obtained in step 1 to the adsorption column that has been loaded into the collection tube, let it stand at room temperature for 1 minute, centrifuge at 13000 rpm for 30-60 seconds, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Attention: The volume of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ l, it can be added in batches.4. Add 500 µ l of Buffer PW to the adsorption column (please check if anhydrous ethanol has been added before use), centrifuge at 13000 rpm for 30-60 seconds, discard the waste liquid in the collection tube, and place the adsorption column in the recovery tube.Note: If purified DNA is used for salt sensitivity experiments (such as flat end ligation experiments or direct sequencing), it is recommended to add Buffer PW and let it stand for 2-5 minutes before centrifugation.5.13000 rpm for 1 minute and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.). To ensure that downstream experiments are not affected by residual ethanol, it is recommended to open the cover of the adsorption column and place it at room temperature for a few minutes to thoroughly dry the residual ethanol in the adsorbent material at the bottom.6. Place the adsorption column into a new centrifuge tube (provided by oneself), add 30-50 µ l Buffer EB to the middle position of the adsorption membrane by hanging droplets, and let it stand at room temperature for 1 minute. Centrifuge at 13000 rpm for 1 minute and collect DNA solution- Store DNA at 20 ℃.Attention:1) The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (the pH value of water can be adjusted to this range using NaOH).2) To improve the recovery of DNA, the solution obtained by centrifugation can be added back to the adsorption column, left at room temperature for 2 minutes, and centrifuged at 13000 rpm for 1 minute.3) The elution volume should not be less than 30 µ l. A small volume will affect the recovery efficiency... Read More | The perfect KitAlysis Labware starter kit that combines the KitAlysis Inertion Box (Z742064) with the KitAlysis 24-Well Reaction Block and Screwdriver Set (Z742107).Provides an inert environment to run oxygen sensitive cross-coupling reactions in a laboratory fume hood.Designed to be used with The perfect KitAlysis Labware starter kit that combines the KitAlysis Inertion Box (Z742064) with the KitAlysis 24-Well Reaction Block and Screwdriver Set (Z742107).Provides an inert environment to run oxygen sensitive cross-coupling reactions in a laboratory fume hood.Designed to be used with KitAlysis High-Throughput Screening Kits.Components:Ιnertion Box24-Well Reaction BlockTorque Screwdriver set with bitReaction Block Replacement Screws (10ea)... Read More | Product contentU665751Component100 TStorageU665751A2×UltraSYBR One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751BUltraSYBR One Step EnzymeMix50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751C50×High ROX50 µL-20℃. AvoidProduct contentU665751Component100 TStorageU665751A2×UltraSYBR One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751BUltraSYBR One Step EnzymeMix50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751C50×High ROX50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751DRNase-Free Water1.5 mL-20℃. Avoid freeze/ Thaw cycle. Product Introduction This product is a specialized kit for one-step Real-Time RT-qPCR. The SYBR Green I fluorescent dye contained can bind to all double-stranded DNA, allowing this product to be used for the detection of many different target sequences without the need to synthesize specific labeling probes. Real Time RT-qPCR reaction using this product, reverse transcription and quantitative PCR are carried out in the same reaction system, there is no need to add reagents during the reaction, no need to open the cap of the tube, avoiding contamination while improving the efficiency of the experiment. The new high-efficiency reverse transcriptase RNase H is activity-deficient, which reduces the degradation of RNA in the reverse transcription reaction. The enzyme has high reverse transcription efficiency and can perform a good reverse transcription reaction on a small amount of RNA template. It has high affinity to RNA and can read through RNA templates with high GC content and complex secondary structure. New efficient hot start enzyme, the enzyme activity is closed at room temperature, thus effectively avoiding non-specific amplification caused by non-specific binding of primers and templates or primer dimerization at room temperature, which greatly improves the accuracy of fluorescence quantitative PCR reaction. The included buffer system maximizes the efficacy of both enzymes at the same time and improves efficiency. This product has high sensitivity, high specificity, wide linear range, and more accurate quantification of target genes.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used with Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument. Instruments that do not require ROX calibration (U665567) Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others. Instruments that require High ROX calibration (U665751) ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1. Before using the reagents in this kit, please mix them gently by turning them up and down to avoid foaming as much as possible, and use them after brief centrifugation.2. This product uses RNA as the template for one-step RT-PCR experiment, RNase contamination should be avoided during operation, it is recommended to operate RNA in a special area, use special instruments and consumables, the operator with a mask and disposable gloves and often change the gloves, the experiment-related consumables should be processed with 0.1% DEPC (diethyl ether of pyrocarbonate) aqueous solution at 37℃ for 12 hours and autoclaved for 30 minutes before use. Sterilize for 30 minutes before use.3. UltraSYBR One Step RT-qPCR Buffer contains SYBR Green I fluorescent dye. Avoid bright light when storing this product or preparing PCR reaction solutions.4. Repeated freezing and thawing of each reagent in this kit should be avoided; repeated freezing and thawing may degrade the product performance. This product can be stored for a long time at -20℃, protected from light. If frequent use is required in the short term, it can be stored at 2-8℃.5. This kit must use specific primers, the choice of primers can be selected according to specific experiments, the good or bad primer design directly affects the results of RT-PCR reaction, the design of primers need to consider the GC content, primer length, primer position, the secondary structure of the PCR product and other factors, it is recommended to use a professional primer design software for design.6. This product cannot be used for fluorescent quantitative PCR by the probe method.Usage1. Dissolve RNA template, primers, 2× UltraSYBR One Step Buffer, UltraSYBR One Step EnzymeMix and RNase-Free Water and set aside on ice.2. PCR reaction system:Reagents25 µl Reaction systemFinal concentration2×UltraSYBR One Step Buffer12.5 µl1×Forward Primer,10 µM0.5 µl0.2 µM¹⁾Reverse Primer,10 µM0.5 µl0.2 µM¹⁾UltraSYBR One Step EnzymeMix0.5 µl RNA TemplateX µl10 pg – 100 ng50×Low ROX or High ROX(optional)2)0.5 µl1×RNase-Free Waterup to 25 µlNote: 1) Usually, the primer concentration of 0.2µM can get better results, and the final concentration of 0.1-0.5µM can be used as a reference for setting the range. If the amplification efficiency is not high, the concentration of primer can be increased; when non-specific reaction occurs, the concentration of primer can be decreased, thus optimizing the reaction system.(2) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.3. Vortex and shake to mix, centrifuge briefly, and collect the solution at the bottom of the tube.4. RT-qPCR reaction conditions (fluorescence quantitative PCR is a two-step method), this program is based on the ABI 7500 fluorescence quantitative PCR instrument as an exampleNote: 1) It is recommended to use two-step PCR reaction program, if you improve the reaction specificity, you can increase the annealing temperature to 60-64 ℃ as a reference for the setting range; if you do not get good experimental results due to the use of primers with lower Tm values, etc., you can try to carry out three-step PCR amplification.(2) For melting curve analysis, please set up the program recommended by the fluorescence quantitative PCR instrument used, and this program is set up with the ABI 7500 fluorescence quantitative PCR instrument as a reference.RT-qPCR reaction conditions (fluorescence quantitative PCR was a three-step method):Note: 1) For three-step PCR amplification, please use the range of 56℃-64℃ as the setting reference for the annealing temperature.(2) For melting curve analysis, please set up the program recommended by the fluorescence quantitative PCR instrument you are using, this program is ABI750 fluorescent quantitative PCR instrument as a reference setting... Read More |