| Description | EndoFree Plasmid Midi Kit Cat No. Component Size(50T) Storage E665631A Buffer P1 30 mL RT E665631B Buffer P2 30 mL RT E665631C Buffer E3 30 mL RT E665631D Buffer PS 15 mL RT E665631E Buffer PW (concentrate) 10 mL RT E665631F Endo-free Buffer EB 10 mL RTEndoFree Plasmid Midi Kit Cat No. Component Size(50T) Storage E665631A Buffer P1 30 mL RT E665631B Buffer P2 30 mL RT E665631C Buffer E3 30 mL RT E665631D Buffer PS 15 mL RT E665631E Buffer PW (concentrate) 10 mL RT E665631F Endo-free Buffer EB 10 mL RT E665631G RNase A (10 mg/mL) 600 µL RT E665631H Buffer ER 8 mL RT E665631I CWBlue 300 µL RT E665631J Spin Columns DL with Collection Tubes 50 EA RT E665631K Endo-Remover FM with Collection 50 EA RTProduct Introduction:Endotoxins are a common pollutant in plasmid extraction. Due to the high sensitivity of eukaryotic cells to endotoxins, the presence of endotoxins in plasmids can greatly reduce the transfection efficiency of eukaryotic cells. This reagent kit provides a simple, fast, and efficient new method for extracting endotoxin free plasmids. The extracted plasmids can remove endotoxins to the maximum extent possible and effectively remove contamination of genomic DNA, RNA, proteins, and other substances. This reagent kit is suitable for extracting 5-15mL of bacterial solution. On the basis of alkaline lysis of cells, it efficiently and specifically binds plasmid DNA through a new silicon-based membrane. Each adsorption column can adsorb up to 100 µ The plasmid DNA of g is effectively removed using a special buffer system and endotoxin removal filter column, effectively removing impurities such as endotoxins and proteins. The plasmid obtained from this kit has high purity and stable quality, making it particularly suitable for cell transfection. It can also be used for downstream experiments such as DNA sequencing, PCR, PCR based mutations, in vitro transcription, transformed bacteria, and endonuclease digestion.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1. All components can be stably stored in a dry, room temperature (15-30 ℃) environment for 1 year, and can be stored at 2-8 ℃ for longer periods of time. Buffer P1 with RNase A added can be stably stored at 2-8 ℃ for 6 months.2. Before the first use, add all RNase A solution to Buffer P1, mix well, and store at 2-8 ℃. Before use, let it sit at room temperature for a period of time. After returning to room temperature, use.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer P2 and Buffer E3. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. Be careful not to come into direct contact with Buffer P2 and Buffer E3, and immediately cover them tightly after use.6.The amount and purity of plasmid extraction are related to factors such as bacterial culture concentration, strain type, plasmid size, and plasmid copy number.Operation steps:1. Take 5-15 mL of overnight cultured bacterial solution and add it to a centrifuge tube (self provided). Centrifuge at 13000 rpm (~16200 × g) for 1 minute to collect bacteria, and try to discard all the supernatant as much as possible.2. Add 500 to the centrifuge tube containing bacterial sediment µ L Buffer P1 (please check if RNase A has been added first), mix thoroughly with a pipette or vortex oscillator, and suspend bacterial precipitation. Attention: If the bacterial blocks are not thoroughly mixed, it will affect the cracking effect, resulting in low extraction amount and purity.3. Add 500 to the centrifuge tube µ L Buffer P2, gently invert and mix 8-10 times, allowing the bacterial cells to fully lyse. Leave at room temperature for 3-5 minutes. At this point, the solution should become clear and viscous. Attention: Mix gently and do not shake vigorously to avoid interrupting genomic DNA and mixing genomic DNA fragments in the extracted plasmid. If the solution does not become clear, it indicates that the bacterial count may be too high and the lysis may not be complete. The bacterial count should be reduced.4. Add 500 to the centrifuge tube µ L Buffer E3, immediately invert and mix 8-10 times until white flocculent precipitates appear. Let it stand at room temperature for 5 minutes. Centrifuge at 13000 rpm for 5 minutes, extract the supernatant, and add it to the filter column (Endo Remove FM) (already loaded into the collection tube). Centrifuge at 13000 rpm for 1 minute to filter, then transfer the filtrate from the collection tube to the centrifuge tube (self provided). Attention: 1) After adding Buffer E3, it should be immediately mixed to avoid local precipitation. 2) The maximum volume of the adsorption column is 750 µ L. So please filter the supernatant twice and mix it in the same self provided centrifuge tube.5. Add 450 to the filtrate µ Mix L isopropanol upside down.6. Column balance: Add 200 to the spin columns DL that have been loaded into the collection tube µ L Buffer PS, centrifuge at 13000 rpm for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Transfer the mixed solution of filtrate and isopropanol from step 5 to an equilibrium adsorption column (already loaded into a collection tube). 8.13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. Attention: The maximum volume of the adsorption column is 750 µ L. So the solution obtained in step 5 is divided multiple times and passed through the column. 9. Add 750 to the adsorption column µ L Buffer PW (please check if anhydrous ethanol has been added first), centrifuge at 13000 rpm for 1 minute, and discard the waste liquid in the collection tube.10. Place the adsorption column back into the recovery manifold and centrifuge at 13000 rpm for 1 minute.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self provided)... Read More | Inquire | The miRNA extraction kit is specifically designed to isolate and purify miRNAs from various animal tissues, plant tissues, cells, serum, plasma and other samples. It can also extract small molecule RNAs such as siRNA and snRNA that are less than 200 nt, and can also be used for the extraction of The miRNA extraction kit is specifically designed to isolate and purify miRNAs from various animal tissues, plant tissues, cells, serum, plasma and other samples. It can also extract small molecule RNAs such as siRNA and snRNA that are less than 200 nt, and can also be used for the extraction of total RNA. This product combines phenol/guanidine lysis technology and silicon matrix membrane purification technology. The unique lysis solution can effectively inhibit RNases while removing most of DNA and proteins from cell or tissue samples through organic extraction. For some sensitive downstream experiments, if miRNA enrichment is required, this kit can be used to enrich miRNA separately. This product is suitable for a wide range of samples, with high purity of prepared RNA, and can be directly used for sensitive downstream applications, such as Northern Blot analysis, Real Time PCR, Microarray Analysis, etc. M665531Component50 TStorageM665531ATRIzon Reagent60 mL2-8℃. Protect from ligt.M665531BBuffer RWT (concentrate)15 mLRTM665531CBuffer RW2 (concentrate)11 mLRTM665531DRNase-Free Water10 mLRTM665531ESpin Columns RM with Collection Tubes50 setsRTM665531FSpin Columns RS with Collection Tubes50 setsRTM665531GRNase-Free Centrifuge Tubes (1.5 mL)50 EART Self prepared reagents: chloroform, anhydrous ethanol (newly opened or dedicated for RNA extraction).Preparation and important precautions before the experiment:To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The extracted samples should avoid repeated freeze-thaw cycles, otherwise it will affect the quantity and quality of miRNA extraction.Before the first use, anhydrous ethanol should be added to Buffer RWT and Buffer RW2 according to the instructions on the reagent bottle label.4. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps:Protocol A: miRNA enrichment (can be directly used for sensitive downstream experiments)1. Sample processing1a Organization: Grind the organization in liquid nitrogen. Add 1 ml of TRIzon Reagent to every 30-50 mg of tissue, shake and mix well. The sample volume shall not exceed one tenth of the volume of TRIzon Reagent.1b Single layer culture of cells: Remove the culture medium, add TRIzon Reagent, and add 1 ml of TRIzon Reagent every 10 cm2 (the amount of lysis solution depends on the area of the culture bottle).1c Cell suspension: Centrifuge to obtain cell precipitate, discard supernatant. Add 1 ml of TRIzon Reagent to every 5 x 106-1 x 107 cells (cells do not require washing).1d Plasma or serum: Take 200 µ Add 5 times the volume of TRIzon Reagent to plasma or serum samples, shake and mix well for 30 seconds.2. After adding TRIzon Reagent to the sample, blow it repeatedly several times to fully crack it. Leave at room temperature for 5 minutes to completely separate the protein nucleic acid complex.3. Optional steps: Centrifuge at 4 ℃ 12000 rpm (~13400 × g) for 5 minutes, take the supernatant, and transfer it to a new centrifuge tube (provided by oneself) (if the sample contains more proteins, fats, polysaccharides, etc., this step can be performed).4. Add chloroform to the supernatant and add 200 to every 1 ml of TRIzon Reagent used µ Chloroform, cover the tube, vigorously shake for 15 seconds, and let it sit at room temperature for 5 minutes.Centrifuge at 5.4 ℃ and 12000 rpm for 15 minutes. The sample is divided into three layers: red organic phase, middle layer, and colorless aqueous phase. Transfer the upper colorless aqueous phase to a new centrifuge tube (self prepared).6. Add 1/3 volume of anhydrous ethanol to the solution obtained in step 5, mix well, and transfer the obtained solution and precipitate together into the adsorption column RM (Spin Columns RM) that has been loaded into the collection tube. If you cannot add all the solution to the adsorption column at once, please transfer it multiple times. Centrifuge at 12000 rpm for 30 seconds, discard the adsorption column RM after centrifugation, and retain the effluent.7. Add 2/3 times the volume of anhydrous ethanol to the solution obtained in step 6 and mix well.8. Transfer the solution and precipitate obtained from the previous step into the adsorption column RS (Spin Columns RS) that has been loaded into the collection tube. If you cannot add all the solution to the adsorption column at once, please transfer it multiple times. Centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RS back into the collection tube.9. Add 700 to the adsorption column RS µ L Buffer RWT (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RS back into the collection tube.10. Add 500 to the adsorption column RS µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RS back into the collection tube.11. Repeat step 10.12. Centrifuge at 12000 rpm for 1 minute and discard the waste liquid from the collection tube. Place the adsorption column RS at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column RS, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).13. Place the adsorption column RS in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store the obtained RNA solution at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 13 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column RS and repeat step 13Protocol B: Extraction of total RNA (including miRNA and other small molecule RNAs<200 nt), steps 1-5 are the same as protocol A.6. Add 1.25 times the volume of anhydrous ethanol to the solution obtained in step 5 and mix well.7. Transfer the solution and precipitate obtained from the previous step into the spin columns RM that have been loaded into the collection tube. If you cannot add all the solution to the adsorption column RM at once, please transfer it multiple times. Centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the collection tube.8. Add 700 to the adsorption column RM µ L Buffer RWT (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the collection tube.9. Add 500 to the adsorption column RM µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the collection tube.10. Repeat step 9.11. Centrifuge at 12000 rpm for 1 minute and discard the waste liquid from the collection tube. Place the adsorption column RM at room temperature for a few minutes to thoroughly air dry. Attention: The purpose of this step is to remove residual ethanol from the adsorption column RM, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).12. Transfer the adsorption column RM into a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store the obtained RNA solution at -70 ℃ to prevent degradation. Attention: 1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 12 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column RM and repeat step 12... Read More | S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948D DNA Standard 2 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948E DNA Standard 3 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948F DNA Standard 4 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948G DNA Standard 5 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis product is used for real-time fluorescence quantitative PCR (qPCR) using the product after NGS library construction by dye method (SYBR Green I). The kit provides the reaction mixture, DNA primer mixture, and standards required for the qPCR process, and the reagent system is complete, easy and convenient to operate. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, and able to quickly and accurately quantify the concentration of the constructed library. It is suitable for fluorescent quantitative PCR instruments that do not require ROX as a calibration dye, such as Roche LightCycler 480, Roche LightCyler 96, Bio-radiCyleriQ, iQ5, CFX96.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Use 2.Scope of applicationThis product is designed for absolute quantification of the concentration of Illumina platform second-generation sequencing libraries. The end of the library contains Illumin P5 and P7 chip binding sequences, the length of which does not exceed 1kb, and the concentration of which is not less than 0.002pM can be used to perform quantitative experiments with this product. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-20 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR Master Mix10 µlqPCR Primer Mix 10.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: add 1 µl High Rox per 50 µl of reaction system;Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.qPCR reaction programThe annealing temperature should be 60-64°C as a reference for the setting range, and the annealing temperature can be increased when a non-specific reaction occurs.If the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.data analysisStandard curve productionThe standard curve was plotted using Ct values in the valid range. The standard curve correlation coefficient R2 should not be less than 0.99 and the slope should lie between -3.1 and -3.6. If the standard curve parameters are not reasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard 120 pMDNA Standard 22 pMDNA Standard 30.2 pMDNA Standard 40.02 pMDNA Standard 50.002 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More | Product contentY666144Component50 TStorageY666144ABuffer P115 mLRTY666144BBuffer P215 mLRTY666144CBuffer N320 mLRTY666144DBuffer PS15 mLRTY666144EBuffer PB10 mLRTY666144FBuffer PW (concentrate)10 mLRTY666144GBuffer EB10 mLRTY666144HGlass Beads2 gRTY666144IRNase A (10mg/mL)150 µLRTY666144JSpin Product contentY666144Component50 TStorageY666144ABuffer P115 mLRTY666144BBuffer P215 mLRTY666144CBuffer N320 mLRTY666144DBuffer PS15 mLRTY666144EBuffer PB10 mLRTY666144FBuffer PW (concentrate)10 mLRTY666144GBuffer EB10 mLRTY666144HGlass Beads2 gRTY666144IRNase A (10mg/mL)150 µLRTY666144JSpin Columns DM with Collection Tubes50 setsRTProductsThis kit is improved on the basis of common alkaline lysis method, the glass beads can effectively break the yeast cell wall, the new silica matrix membrane and buffer system can efficiently and specifically bind the plasmid DNA, and at the same time can maximize the removal of proteins and other impurities, the whole process is convenient and fast, no need to use toxic and harmful reagents, and can be processed at the same time for multiple samples. In addition to yeast cells, it can also be used in E. coli. Plasmid DNA extracted with this kit can be used in various molecular biology experiments, such as ligation, transformation, sequencing and library screening.Self-contained reagents: β-mercaptoethanol, anhydrous ethanol.Pre-experiment Preparation and Important Notes1. All components can be stably stored in dry, room temperature (15-30℃) environment for 1 year, the adsorption column can be stored at 2-8℃ for a longer period of time, and Buffer P1 with RNase A can be stably stored at 2-8℃ for 6 months.2. Before the first use, add all the RNase A solution to Buffer P1, mix well, and store at 2-8℃.3. Anhydrous ethanol should be added to Buffer PW before first use according to the instructions on the reagent bottle label.4. Before use, please check whether Buffer P2 and Buffer N3 are crystallized or precipitated. If there is any crystallization or precipitation phenomenon, it can be clarified by taking a water bath at 37℃ for a few minutes to restore the clarity.5. Be careful not to touch Buffer P2 and Buffer N3 directly, and tighten the lid immediately after use.6. The amount of plasmid extracted is related to the yeast strain, plasmid copy number, culture conditions, etc. Usually, yeast plasmid copy number is very low, which is difficult to be detected by electrophoresis or spectrophotometer method.Procedure1. Take 1-5 ml of yeast culture (maximum 5×107 yeast cells, generally for Saccharomyces cerevisiae OD = 1.0, equivalent to 1-2×107 cells/ml) and add it to a centrifuge tube (self-provided), centrifuge for 30 seconds at 12,000 rpm (~13,400×g), collect the bacterial precipitate, and aspirate as much as possible to discard the supernatant.2. Add 250µl Buffer P1 to the bacterium (please check if RNase A has been added first) and resuspend the precipitate.3. Add 40mg of Glass Beads to the above mixture and vortex and shake for 10 minutes.4. Add 250 µl of Buffer P2 to the centrifuge tube, mix gently by turning up and down 6-8 times, and let stand at room temperature for 5-10 minutes, at which time the bacterial solution should become clear and viscous.Note: Mix gently, do not shake violently, so as not to interrupt the genomic DNA, resulting in genomic DNA fragments mixed in the extracted plasmid. If the solution does not become clear, it suggests that the amount of bacteria may be too large and the lysis is not complete, and the amount of bacteria should be reduced.5. Add 350 µl of Buffer N3 to the centrifuge tube and immediately mix gently up and down 6-8 times, at which point a white flocculent precipitate appears, and centrifuge at 12,000 rpm for 20 minutes.Note: Buffer N3 should be mixed immediately after addition to avoid localized precipitation.6. Column Equilibration: Add 200 µl of Buffer PS to the Spin Columns DM in the collection tube, centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and place the column back into the collection tube.7. Add the supernatant from step 5 to the adsorbent column that has been loaded into the collection tube, taking care not to aspirate the precipitate.Note: The maximum volume of the adsorption column is 750 µl, and the solution is passed through the column in 2 times.8. Centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube and place the adsorption column back into the collection tube.9. Add 150 µl Buffer PB to the adsorbent column, centrifuge at 12,000 rpm for 1 min, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.10. Add 750 µl Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first), centrifuge at 12,000 rpm for 1 minute, and pour off the waste liquid in the collection tube.11. Place the column back into the recovery collection tube and centrifuge at 12,000 rpm for 2 minutes, pouring off the waste liquid. Leave the column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).12. Place the adsorbent column in a new centrifuge tube, add 50-100 µl of Buffer EB to the center of the adsorbent membrane dropwise, let it stand at room temperature for a few minutes, centrifuge at 13,000 rpm for 1 minute, and collect the plasmid solution into the centrifuge tube. Store the plasmid at -20°C.Attention:1) To increase the recovery efficiency of the plasmid, the resulting solution can be reintroduced into the adsorbent column, left at room temperature for a few minutes, centrifuged at 13,000 rpm for 1 minute, and the plasmid solution collected into a centrifuge tube.2) When the plasmid copy number is low or >10 kb, Buffer EB is preheated at 65-70°C in a water bath, which can increase the extraction efficiency.3) Usually yeast plasmids have very low copy number and are difficult to detect by electrophoresis or spectrophotometry. If the extracted plasmid is to be used in the next step of the experiment, it is usually recommended to use 1-5µl of the plasmid as PCR template, and 5-10µl of the plasmid for transformation of E. coli.4) Commercial high transformation efficiency receptor cells should be used for transformation of E. coli... Read More |