| Description | FFPE DNA/RNA KitFixed Tissue DNA/RNA Extraction Kit Catalog number: F666120 (50 preps)Storage conditions: DNase I and 10×Reaction Buffer -20℃, Spin Columns DF and Spin Columns RS can be stored at room temperature for 2 months, 2-8℃ for 1 year, the rest of the components are stored FFPE DNA/RNA KitFixed Tissue DNA/RNA Extraction Kit Catalog number: F666120 (50 preps)Storage conditions: DNase I and 10×Reaction Buffer -20℃, Spin Columns DF and Spin Columns RS can be stored at room temperature for 2 months, 2-8℃ for 1 year, the rest of the components are stored at room temperature (15-30℃).Products Content:Products IntroductionThis kit is suitable for the effective purification of genomic DNA and total RNA from paraffin-embedded tissues, using specially optimized deparaffinizing agents and lysates to release DNA and RNA from tissue section samples, without the use of the organic reagent xylene, and without the need for overnight operation; the digested samples are incubated at higher temperatures to remove inhibitors caused by cross-linking, which can effectively improve nucleic acid yields and purity; and an optimized buffer system allows nucleic acids in the lysate to bind specifically to the adsorbent membrane, and inhibitors are effectively removed by a two-step rinsing procedure. The optimized buffer system enables the nucleic acids in the lysate to bind specifically to the adsorbent membrane, and the inhibitors are effectively removed by a two-step rinsing step, and finally eluted with low-salt buffer or water to obtain high purity DNA and RNA, and at the same time, equipped with a high-efficiency microsorbent column, the volume of the elution can be as low as 20 µl. The purified DNA and RNA can be directly used for PCR, Real-time PCR, SNP genotyping, STR genotyping, and so on. The purified DNA and RNA can be directly used for PCR, Real-time PCR, SNP genotyping, STR genotyping, second-generation sequencing, pharmacogenomics research and blot analysis.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes 1. After obtaining the sample, fix the sample as soon as possible, the fixation time of 14-24 hours is appropriate, too long a period of time will easily lead toDNA and RNA breaks, affecting downstream experiments. If the formaldehyde fixation time is too long or the sample is stored for too long(>1 year) is prone to compromise DNA integrity and failure to amplify long fragments.2. Ensure that samples are thoroughly dehydrated prior to embedding; residual formalin will inhibit Proteinase K action.3. Add 1.25 ml of Proteinase K Storage Buffer to Proteinase K to dissolve it, and store at -20℃. Do not leave the prepared Proteinase K at room temperature for a long period of time to avoid affecting its activity.4. Anhydrous ethanol should be added to Buffer RW2, Buffer GW1 and Buffer GW2 according to the label instructions on the vials before first use.5. Check Buffer GTL, Buffer GL and Buffer DS for crystallization or precipitation prior to use; if crystallization or precipitation occurs, redissolve Buffer GTL, Buffer GL and Buffer DS in a 37°C water bath.6. Preheat the water bath or thermostatic mixer to 56°C before starting the experiment.7. Use an ambient temperature centrifuge or set the centrifuge temperature to 25°C. Temperatures below 15°C may result in clogging of the adsorption column.8. To prevent RNase contamination, the following should be observed:1) Use RNase-free plastics and tips to avoid cross-contamination.(2) Glassware should be dry baked at 180°C for 4 hours before use, plasticware can be soaked in 0.5 M NaOH for 10 minutes, rinsed thoroughly with water and autoclaved.3) RNase-free water should be used to prepare the solution.(4) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.procedureParaffin-embedded samples1. Trim off excess paraffin from the tissue block to expose the tissue and cut into 5-10 µm slices.2. Place approximately 1 x 1 cm2 slices (1-5 slices in total) in a centrifuge tube (supplied), add 500 µl of Buffer DS and vortex for 10 s. Briefly centrifuge the sample to the bottom of the tube. Centrifuge briefly to collect the sample at the bottom of the tube, incubate at 56°C for 3 minutes, remove from the water bath and allow to cool to room temperature before proceeding.Note: If the surface of the sample is exposed to air, discard the initial 2-3 slices without using them.3. Centrifuge at 12,000 rpm for 2 minutes and carefully discard the supernatant thoroughly without aspirating the precipitate. The residual dewaxing solution can be carefully removed with a small tip (10 µl).4. Add 180 µl of Buffer GTL and 20 µl of Proteinase K to the above tube and mix well with vortexing.5. Incubate at 56°C for 15 minutes, then place on ice for 3 minutes. Centrifuge at 12,000 rpm for 15 minutes at room temperature.6. Transfer the supernatant to a new 1.5 ml centrifuge tube for RNA extraction, taking care not to aspirate undigested tissue. Use the precipitate for DNA extraction. RNA extraction7. Take the supernatant obtained in step 6 and incubate at 80°C for 15 minutes.8. Add 320 µl of Buffer GL, mix by vortexing and shaking, then add 720 µl of anhydrous ethanol and mix immediately by vortexing and shaking.9. Add all of the resulting solution to the Spin Columns RS in the collection tube; if the solution cannot be added all at once, it may be transferred in several passes. centrifuge the column at 12,000 rpm for 1 minute, pour off the waste solution from the collection tube, and place the column back into the collection tube. Note: If the columns are clogged, the sample size may be too large and consideration should be given to reducing the number of starting sections to 1-2.Optional step: If genomic DNA is to be removed, the following steps can be followeda. Add 350 µl of Buffer RW1 to the column, centrifuge at 12,000 rpm for 1 minute, discard the waste solution, and place the column back into the collection tube.b. Preparation of DNase I mixture: Take 52 µl of RNase-Free Water and add 8 µl of 10×Reaction to it.Buffer and 20 µl DNase I (1 U/µl), mix well, and prepare a final volume of 80 µl of reaction solution.c. Add 80 µl of DNase I Mix directly to the adsorption column and incubate at 20-30°C for 15 minutes.d. Add 350 µl of Buffer RW1 to the column, centrifuge at 12,000 rpm for 1 minute, discard the waste solution, and return the column to the collection tube.Add 500 µl of Buffer RW2 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.11. Repeat step 10. centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Place the column at room temperature for 5 minutes.minutes to dry thoroughly.12. Place the column in a new RNase-free centrifuge tube and add 20-50 µl to the center of the column.RNase-Free Water, left at room temperature for 5 minutes, centrifuged at 12,000 rpm for 1 minute, and collected RNA solution, the-80°C for storage.DNA extraction7. Take the precipitate obtained in step 6 and add 180 µl Buffer GTL and 20 µl Proteinase K to the precipitate. VortexResuspend the precipitate for 15 seconds.8. Incubate at 56°C for 1 hour until the sample is completely dissolved. 90°C for 1 hour.Add 200 µl Buffer GL, vortex and shake to mix and then add 200 µl anhydrous ethanol, vortex and shake to mix thoroughly. Centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube. Add all of the solution from step 9 to the Spin Columns DF in the collection tube, or transfer the solution in several passes. centrifuge at 12,000 rpm for 1 minute, pour off the waste solution from the collection tube, and return the column to the 10. collection tube.Note: If the adsorption column is clogged, the sample size may be too large and consideration should be given to reducing the number of starting sections to 1-2.11. Add 500 µl of Buffer GW1 to the adsorbent column and centrifuge at 12,000 rpm for 1 minute. Pour off the waste liquid from the collection tube and put the column back into the collection tube.12. Add 500 µl of Buffer GW2 to the adsorbent column and centrifuge at 12,000 rpm for 1 minute. Pour off the waste liquid from the collection tube and place the column back into the collection tube.Note: Step 12 may be repeated if further purity is required.13. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for 5 minutes to dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorbent column; ethanol residue will affect the subsequent enzymatic reaction. 14. Place the column in a new 1.5 ml centrifuge tube, add 20-50 µl Buffer EB to the center of the column, leave at room temperature for 5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store at -20℃... Read More | Product content C665709Component50 TStorageC665709ABuffer CL45 mLRTC665709BBuffer CB (concentrate)60 mLRTC665709CBuffer GW1 (concentrate)13 mLRTC665709DBuffer GW2 (concentrate)15 mLRTC665709EBuffer EBL10 mLRTC665709FProteinase K100 mgRTC665709GProteinase K Storage Buffer5 mLRTC665709HSpin Columns DFProduct content C665709Component50 TStorageC665709ABuffer CL45 mLRTC665709BBuffer CB (concentrate)60 mLRTC665709CBuffer GW1 (concentrate)13 mLRTC665709DBuffer GW2 (concentrate)15 mLRTC665709EBuffer EBL10 mLRTC665709FProteinase K100 mgRTC665709GProteinase K Storage Buffer5 mLRTC665709HSpin Columns DF with Collection Tubes50 EA2-8℃C665709ICentrifuge Tubes (L-1.5 mL)50 EART Product IntroductionThis kit is suitable for the extraction of free DNA from fresh or frozen serum, plasma, lymph fluid and other cell-free body fluids.This kit adopts centrifugal adsorption columns that can specifically bind nucleic acids and a unique buffer system.After the sample is lysed, the free DNA binds to the silica gel membrane under high salt conditions, and the free DNA elutes from the silica gel membrane at low salt and high pH. The product can handle liquid samples of 0.1-1 ml, and the elution volume of the configured high-efficiency micro adsorption column can be as low as 20 µl. The purified DNA is of high yield and quality, with maximum removal of proteins, pigments, lipids, and other inhibitors, and the rate of free DNA yield is highly dependent on the type of samples, storage conditions, time, and inter-individual variations. The quality of free DNA obtained from purification is stable and reliable, and can be directly used in molecular biology experiments such as PCR, fluorescence quantitative PCR and second generation sequencing.Self-contained reagents: anhydrous ethanol, isopropanol.Pre-experiment Preparation and Important NotesAdd 5 ml of Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time.Repeated freezing and thawing of the sample should be avoided, as this can lead to a decrease in extraction.This kit can extract 0.1-1 ml of liquid samples.Before use, please check Buffer CL, Buffer CB for crystallization or precipitation, if there is any crystallization or precipitation, please re-dissolve Buffer CL, Buffer CB by incubation at 56℃ in a water bath.Before first use isopropyl alcohol should be added to Buffer CB according to the instructions on the reagent bottle label, mixed well, and labeled on the reagent bottle label.Before the first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle, mixed well, and labeled on the label of the reagent bottle.Preheat the water bath to 60°C before starting the experiment.The elution buffer Buffer EBL can be preheated to 60°C and used.Operation stepsAdd 20 µl of Proteinase K to the centrifuge tube (supplied).Add 200 µl of serum/plasma sample.Note: When the sample volume exceeds 200 µl, please increase the amount of Proteinase K, Buffer CL and Buffer CB reagents in equal proportions, and the specific amount of reagents added can be referred to the attached table.3. Add 160 µl Buffer CL, mix upside down and shake vigorously for at least 30 seconds.4. Incubate at 60°C for 30 minutes, during which time mixing was inverted several times.Note: Incubation of 200µl serum/plasma samples at 60°C for 10-15 minutes is sufficient.Add 360 µl of Buffer CB (check for addition of isopropanol before use) and shake until thoroughly mixed.Ice bath for 5 minutes and centrifuge briefly to concentrate the liquid on the walls and wall caps to the bottom of the tube.Add all of the solution obtained in step 6 to the adsorption columns (Spin Columns DF) that have been loaded into the collection tubes, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge the columns at 12,000 rpm for 1 minute, pour off the waste solution from the collection tubes, and put the columns back into the collection tubes.Add 500µl of Buffer GW1 to the adsorbent column (check that anhydrous ethanol is added before use),centrifuge the column at 12,000rpm for 30 seconds, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.Add 750 µl Buffer GW2 to the adsorbent column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 30 seconds, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.10. Add 750 µl of anhydrous ethanol to the adsorbent column and centrifuge at 12,000 rpm for 30 s. Pour off the waste liquid in the collection tube and put the adsorbent column back into the collection tube.11. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with the subsequent enzymatic reaction.12. Place the adsorption column in a new centrifuge tube, add 20-100 µl Buffer EBL or sterilized water to the middle part of the adsorption column overhanging the column, leave it at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20℃.Note: 1) If the downstream experiment is sensitive to pH, you can use sterilized water for elution. The pH value of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH value is 7.0-8.5 (you can use NaOH to adjust the pH value of water to this range), and the elution efficiency is not high when the pH value is lower than 7.0.2) Preheat the elution buffer BufferEBL to 60℃ and use it, and incubate it at room temperature for 5 minutes before centrifugation to increase the yield.3) If the final concentration of DNA is to be increased, the resulting solution can be reintroduced into the adsorption column and left at room temperature for 2-5 minutes and centrifuged at 12,000 rpm for 1 minute.4) Because DNA preserved in water will be affected by acidic hydrolysis, for long-term storage, it is recommended to elute it with Buffer EBL and store it at -20℃.Table: Recommended reagent additions for different sample sizes... Read More | Product contentG665801Component100 TStorageG665801A2×GoldStar Probe One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801BGoldStar Probe One Step EnzymeMix100 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801C50×High ROX50 µL-20Product contentG665801Component100 TStorageG665801A2×GoldStar Probe One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801BGoldStar Probe One Step EnzymeMix100 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801C50×High ROX50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801DRNase-Free Water1.5 mL-20℃. Avoid freeze/ Thaw cycle. Product Introduction This product is a specialized kit for one-step Real-Time RT-qPCR using the probe method (TaqMan, Molecular Beacon, etc.). When using this product for Real Time RT-qPCR reaction, reverse transcription and quantitative PCR are carried out in the same reaction system, and there is no need to add reagents or open the cap of the tube during the reaction process, which avoids contamination and improves the experimental efficiency at the same time. With high detection sensitivity, strong fluorescence signal and high signal-to-noise ratio, this product is very suitable for the detection of RNA viruses and other trace RNA. The special buffer system contained in this product can maximize the effectiveness of reverse transcriptase and DNA polymerase at the same time and improve the efficiency of the reaction. A wider linear range can be obtained with this product, more accurate quantification of the target gene, good reproducibility and high confidence.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument. Instruments that do not require ROX calibration (G665836) Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others. Instruments that require High ROX calibration (G665801) ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1.Before using the reagents in this kit, please mix them gently by turning them up and down to avoid foaming as much as possible, and use them after brief centrifugation.2.This product uses RNA as the template for one-step RT-PCR experiment, RNase contamination should be avoided during operation, it is recommended to operate RNA in a special area, use special instruments and consumables, the operator with a mask and disposable gloves and often change the gloves, the experiment-related consumables should be processed with 0.1% DEPC (diethyl ether pyrocarbonate) aqueous solution for 12 hours at 37℃, and autoclaved for 30 minutes before use. The consumables should be treated with 0.1% DEPC (diethylpyrocarbonate) aqueous solution at 37℃ for 12 hours and autoclaved for 30 minutes.3.Repeated freezing and thawing of each reagent in this kit should be avoided as much as possible; repeated freezing and thawing may degrade the product performance.4.This kit must use specific primers, the choice of primers can be selected according to specific experiments, the good or bad primer design directly affects the results of RT-qPCR reaction, the design of primers need to consider the GC content, primer length, primer position, the secondary structure of the PCR product and other factors, it is recommended to use a professional primer design software for design.5.This kit is recommended to use specific probes, and it is recommended to use professional design software for designing.UsageThe following examples are conventional reaction systems and conditions, which should be improved and optimized according to the different templates, primer structures and target fragment sizes in actual operation. (Please prepare the reaction solution on ice.)1. Dissolve RNA template, primers, 2× GoldStar Probe One Step Buffer, GoldStar Probe One Step EnzymeMix and RNase-Free Water and set aside on ice.2. PCR reaction system:reagents25µl reaction systemfinal concentration2×GoldStar Probe One Step Buffer12.5µl1×Forward Primer, 10µM0.5µl0.2µM¹⁾Reverse Primer, 10µM0.5µl0.2µM¹⁾Probe, 10µM0.5µl0.2µM²⁾GoldStar Probe One Step EnzymeMix1.0µl RNA TemplateXµl10pg-100ng³⁾50 x Low ROX or High ROX (optional)⁴⁾0.5µl1×RNase-Free WaterUp to 25µlNote: 1) Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.(2) The concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of RNA template is 10pg-100ng as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be diluted in gradient to determine the optimal amount of template to use.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.3. Mix well, centrifuge briefly, and collect the solution at the bottom of the tube.4.RT-PCR reaction conditions:Note: 1) The hot start enzyme used in this product must be activated under the condition of pre-denaturation 95℃, 5-10min. 2) It is recommended to use the two-step PCR reaction program, if you can not get good experimental results due to the use of primers with lower Tm value, etc., you can try to carry out the three-step PCR amplification, and the annealing temperature should be set in the range of 56℃-64℃ as a reference... Read More | The perfect KitAlysis Labware starter kit that combines the KitAlysis Inertion Box (Z742064) with the KitAlysis 24-Well Reaction Block and Screwdriver Set (Z742107).Provides an inert environment to run oxygen sensitive cross-coupling reactions in a laboratory fume hood.Designed to be used with The perfect KitAlysis Labware starter kit that combines the KitAlysis Inertion Box (Z742064) with the KitAlysis 24-Well Reaction Block and Screwdriver Set (Z742107).Provides an inert environment to run oxygen sensitive cross-coupling reactions in a laboratory fume hood.Designed to be used with KitAlysis High-Throughput Screening Kits.Components:Ιnertion Box24-Well Reaction BlockTorque Screwdriver set with bitReaction Block Replacement Screws (10ea)... Read More | DescriptionThe Universal Coupling Kit makes particle-based immunoassays, lateral flow tests and biomolecule separation applications more flexible than ever before. It is the only kit that allows users to select and couple their choice of carboxylated particle with their chosen protein.Employing a DescriptionThe Universal Coupling Kit makes particle-based immunoassays, lateral flow tests and biomolecule separation applications more flexible than ever before. It is the only kit that allows users to select and couple their choice of carboxylated particle with their chosen protein.Employing a unique mechanism to immobilise proteins, Anteo′s advantages outweigh those of conventional covalent chemistries such as NHS/EDC or passive binding. This facilitates coupling of antibodies with ease, improved functionality and reproducibility, leading to better uniformity between experiments.Anteo′s Activation Reagent is water-based and replaces the dry chemicals you would use with the traditional NHS/EDC method. Our One-Step-Activation only takes one hour, and improves efficiency in terms of both time and cost. It also provides the ability to either store activated particles up to 12 months for later use, or to immediately couple proteins.Particle-Based Immunoassays, Lateral Flow, Bioseparations and Immunoprecipitation... Read More |