| Description | FFPE DNA/RNA KitFixed Tissue DNA/RNA Extraction Kit Catalog number: F666120 (50 preps)Storage conditions: DNase I and 10×Reaction Buffer -20℃, Spin Columns DF and Spin Columns RS can be stored at room temperature for 2 months, 2-8℃ for 1 year, the rest of the components are stored FFPE DNA/RNA KitFixed Tissue DNA/RNA Extraction Kit Catalog number: F666120 (50 preps)Storage conditions: DNase I and 10×Reaction Buffer -20℃, Spin Columns DF and Spin Columns RS can be stored at room temperature for 2 months, 2-8℃ for 1 year, the rest of the components are stored at room temperature (15-30℃).Products Content:Products IntroductionThis kit is suitable for the effective purification of genomic DNA and total RNA from paraffin-embedded tissues, using specially optimized deparaffinizing agents and lysates to release DNA and RNA from tissue section samples, without the use of the organic reagent xylene, and without the need for overnight operation; the digested samples are incubated at higher temperatures to remove inhibitors caused by cross-linking, which can effectively improve nucleic acid yields and purity; and an optimized buffer system allows nucleic acids in the lysate to bind specifically to the adsorbent membrane, and inhibitors are effectively removed by a two-step rinsing procedure. The optimized buffer system enables the nucleic acids in the lysate to bind specifically to the adsorbent membrane, and the inhibitors are effectively removed by a two-step rinsing step, and finally eluted with low-salt buffer or water to obtain high purity DNA and RNA, and at the same time, equipped with a high-efficiency microsorbent column, the volume of the elution can be as low as 20 µl. The purified DNA and RNA can be directly used for PCR, Real-time PCR, SNP genotyping, STR genotyping, and so on. The purified DNA and RNA can be directly used for PCR, Real-time PCR, SNP genotyping, STR genotyping, second-generation sequencing, pharmacogenomics research and blot analysis.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes 1. After obtaining the sample, fix the sample as soon as possible, the fixation time of 14-24 hours is appropriate, too long a period of time will easily lead toDNA and RNA breaks, affecting downstream experiments. If the formaldehyde fixation time is too long or the sample is stored for too long(>1 year) is prone to compromise DNA integrity and failure to amplify long fragments.2. Ensure that samples are thoroughly dehydrated prior to embedding; residual formalin will inhibit Proteinase K action.3. Add 1.25 ml of Proteinase K Storage Buffer to Proteinase K to dissolve it, and store at -20℃. Do not leave the prepared Proteinase K at room temperature for a long period of time to avoid affecting its activity.4. Anhydrous ethanol should be added to Buffer RW2, Buffer GW1 and Buffer GW2 according to the label instructions on the vials before first use.5. Check Buffer GTL, Buffer GL and Buffer DS for crystallization or precipitation prior to use; if crystallization or precipitation occurs, redissolve Buffer GTL, Buffer GL and Buffer DS in a 37°C water bath.6. Preheat the water bath or thermostatic mixer to 56°C before starting the experiment.7. Use an ambient temperature centrifuge or set the centrifuge temperature to 25°C. Temperatures below 15°C may result in clogging of the adsorption column.8. To prevent RNase contamination, the following should be observed:1) Use RNase-free plastics and tips to avoid cross-contamination.(2) Glassware should be dry baked at 180°C for 4 hours before use, plasticware can be soaked in 0.5 M NaOH for 10 minutes, rinsed thoroughly with water and autoclaved.3) RNase-free water should be used to prepare the solution.(4) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.procedureParaffin-embedded samples1. Trim off excess paraffin from the tissue block to expose the tissue and cut into 5-10 µm slices.2. Place approximately 1 x 1 cm2 slices (1-5 slices in total) in a centrifuge tube (supplied), add 500 µl of Buffer DS and vortex for 10 s. Briefly centrifuge the sample to the bottom of the tube. Centrifuge briefly to collect the sample at the bottom of the tube, incubate at 56°C for 3 minutes, remove from the water bath and allow to cool to room temperature before proceeding.Note: If the surface of the sample is exposed to air, discard the initial 2-3 slices without using them.3. Centrifuge at 12,000 rpm for 2 minutes and carefully discard the supernatant thoroughly without aspirating the precipitate. The residual dewaxing solution can be carefully removed with a small tip (10 µl).4. Add 180 µl of Buffer GTL and 20 µl of Proteinase K to the above tube and mix well with vortexing.5. Incubate at 56°C for 15 minutes, then place on ice for 3 minutes. Centrifuge at 12,000 rpm for 15 minutes at room temperature.6. Transfer the supernatant to a new 1.5 ml centrifuge tube for RNA extraction, taking care not to aspirate undigested tissue. Use the precipitate for DNA extraction. RNA extraction7. Take the supernatant obtained in step 6 and incubate at 80°C for 15 minutes.8. Add 320 µl of Buffer GL, mix by vortexing and shaking, then add 720 µl of anhydrous ethanol and mix immediately by vortexing and shaking.9. Add all of the resulting solution to the Spin Columns RS in the collection tube; if the solution cannot be added all at once, it may be transferred in several passes. centrifuge the column at 12,000 rpm for 1 minute, pour off the waste solution from the collection tube, and place the column back into the collection tube. Note: If the columns are clogged, the sample size may be too large and consideration should be given to reducing the number of starting sections to 1-2.Optional step: If genomic DNA is to be removed, the following steps can be followeda. Add 350 µl of Buffer RW1 to the column, centrifuge at 12,000 rpm for 1 minute, discard the waste solution, and place the column back into the collection tube.b. Preparation of DNase I mixture: Take 52 µl of RNase-Free Water and add 8 µl of 10×Reaction to it.Buffer and 20 µl DNase I (1 U/µl), mix well, and prepare a final volume of 80 µl of reaction solution.c. Add 80 µl of DNase I Mix directly to the adsorption column and incubate at 20-30°C for 15 minutes.d. Add 350 µl of Buffer RW1 to the column, centrifuge at 12,000 rpm for 1 minute, discard the waste solution, and return the column to the collection tube.Add 500 µl of Buffer RW2 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.11. Repeat step 10. centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Place the column at room temperature for 5 minutes.minutes to dry thoroughly.12. Place the column in a new RNase-free centrifuge tube and add 20-50 µl to the center of the column.RNase-Free Water, left at room temperature for 5 minutes, centrifuged at 12,000 rpm for 1 minute, and collected RNA solution, the-80°C for storage.DNA extraction7. Take the precipitate obtained in step 6 and add 180 µl Buffer GTL and 20 µl Proteinase K to the precipitate. VortexResuspend the precipitate for 15 seconds.8. Incubate at 56°C for 1 hour until the sample is completely dissolved. 90°C for 1 hour.Add 200 µl Buffer GL, vortex and shake to mix and then add 200 µl anhydrous ethanol, vortex and shake to mix thoroughly. Centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube. Add all of the solution from step 9 to the Spin Columns DF in the collection tube, or transfer the solution in several passes. centrifuge at 12,000 rpm for 1 minute, pour off the waste solution from the collection tube, and return the column to the 10. collection tube.Note: If the adsorption column is clogged, the sample size may be too large and consideration should be given to reducing the number of starting sections to 1-2.11. Add 500 µl of Buffer GW1 to the adsorbent column and centrifuge at 12,000 rpm for 1 minute. Pour off the waste liquid from the collection tube and put the column back into the collection tube.12. Add 500 µl of Buffer GW2 to the adsorbent column and centrifuge at 12,000 rpm for 1 minute. Pour off the waste liquid from the collection tube and place the column back into the collection tube.Note: Step 12 may be repeated if further purity is required.13. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for 5 minutes to dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorbent column; ethanol residue will affect the subsequent enzymatic reaction. 14. Place the column in a new 1.5 ml centrifuge tube, add 20-50 µl Buffer EB to the center of the column, leave at room temperature for 5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store at -20℃... Read More | Glycogen and starch generate glucose-1-phosphate (1PG/G1P) during the process of phosphohydrolysis. This reagent kit provides a simple, sensitive, and rapid determination method: Glucose-1-phosphate (1PG/G1P) is reduced from NADP+to NADPH by the sequential action of phosphoglucose mutase and Glycogen and starch generate glucose-1-phosphate (1PG/G1P) during the process of phosphohydrolysis. This reagent kit provides a simple, sensitive, and rapid determination method: Glucose-1-phosphate (1PG/G1P) is reduced from NADP+to NADPH by the sequential action of phosphoglucose mutase and phosphoglucose dehydrogenase. The content of glucose-1-phosphate (1PG/G1P) in the sample can be calculated by detecting the increase in NADPH at 340nm.Composition and preparation of reagent kit: Reagent name Specifications Save requirements Remarks Extraction solution Liquid 100mL x 1 bottle 4 ℃ storage / Reagent 1 Powder mg x 1 tube 4 ℃ storage Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then dissolve it in 1.2mL of distilled water for later use. Reagent 2 Powder mg x 1 tube Store at -20 ℃ Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then dissolve it in 1.2mL of distilled water for later use. Reagent 3 Liquid 16mL x 1 bottle 4 ℃ storage / Reagent 4 Powder mg x 1 tube Store at -20 ℃ Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then add 1 Dissolve 1mL of distilled water for later use. TRC 1 powder 4 ℃ storage Only used to identify whether the reagents in the kit are normal (not involved in result calculation). Usage: Use a pre standard tube (GIP) to shake the powder a few times until it falls to the bottom, then add 0.5mL of distilled water and mix well to dissolveDilute GIP with a concentration of 4mg/mL and then dilute it four times to 1mg/mL for later use: follow the instructions in the sample addition table for the measuring tube operationRequired instruments and supplies:ELISA reader, 96 well plate, desktop centrifuge, adjustable pipette, mortar, ice and distilled water.Determination of glucose-1-phosphate (1PG/G1P) content:1. Sample preparation① Organizational sample:Suggest weighing around 0 1g of tissue, add 1mL of extraction solution, and homogenize in an ice bath. Centrifuge at 12000rpm, 4 ℃ for 10 minutes, take the supernatant, and place it on ice for testing.[Note]: If the sample size is increased, it can be extracted in a ratio of tissue mass (g) to extraction solution volume (mL) of 1:5-10.② Bacterial/cellular samples:Collect bacteria or cells into a centrifuge tube first, centrifuge and discard the supernatant; Take about 5 million bacteria or cells and add them to 1mLExtract solution, sonicate bacteria or cells (ice bath, power 200W, sonication for 3s, interval 10s, repeated 30 times); Centrifuge at 12000rpm at 4 ℃ for 10 minutes, take the supernatant, and place it on ice for testing.[Note]: If the sample size is increased, extraction can be carried out in a ratio of 500-1000:1 of bacteria/cell quantity (104) to extraction solution (mL).③ Liquid sample: direct detection.2. Machine testing:① Preheat the enzyme-linked immunosorbent assay (ELISA) reader for at least 30 minutes and adjust the wavelength to 340nm.② Thaw the reagent to room temperature (25 ℃);③ Add reagents to the 96 well plate in the following order according to the table:② Thaw the reagent to room temperature (25 ℃);③ Add reagents to the 96 well plate in the following order according to the table: Reagent name (µL) Measurement tube Blank tube (only done once) Reagent 1 10 10 Reagent 2 10 10 Reagent 3 150 170 Sample 20 / Mix well, incubate at room temperature (25 ℃) for 20 minutes, and then read A1 at 340nm (if the A value continues to increase, the incubation time needs to be extended until the absorbance value remains unchanged within 2 minutes). Reagent 4 10 10 Mix well, incubate at room temperature (25 ℃) for 20 minutes, and then read A2 at 340nm (if the A value continues to increase, the incubation time needs to be extended until the absorbance value remains unchanged within 2 minutes). Δ A=(A2-A1) measurement - (A2-A1) blank.[Note] 1 If the difference in Δ A is hovering around zero, the sample size V1 can be increased (such as increasing to 50 µ L, the three phases of the reagent should be reduced while keeping the total volume unchanged), or the sample sampling mass W can be increased. The changed V1 and W need to be substituted into the formula for recalculation.If the A2 value exceeds 1.2, the amount of sample added V1 can be reduced (such as to 10 µ L, the three-phase reagent should be increased while keeping the total volume unchanged), or the sample can be diluted with distilled water (keeping the sample addition system unchanged), and the changed V1 and D need to be substituted into the formula for recalculation.Result calculation:1. Calculated by sample weight:1PG/G1P content (µ g/g fresh weight)=[(Δ A ÷ (ε× d) × V2 × 106 × MR] ÷ (W × V1 ÷ V) × D=836 × Δ A ÷ W × D2. Calculated by the number of cells:1PG/G1P content (µ g/104 cell)=[(Δ A ÷ (ε× d) × V2 × 106 × MR] ÷ (500 × V1 ÷ V) × D=1.7 × Δ A × D. 3. Calculated by liquid volume:1PG/G1P content (µ g/mL)=[(Δ A ÷ (ε× d) × V2 × 106 × Mr] ÷ V1=836 × Δ A ε---NADPH Molar extinction coefficient,6.22×103 L/mol/cm; d---96 Orifice plate optical diameter,0.5cm; V---Add volume of extraction solution,1 mL; V1---Add sample volume,0.02mL V2---Total reaction volume;0.2mL=2×10-4L; W---Sample quality,g; Mr---Glucose-1-phosphate(1PG/G1P)Molecular weight;260; 500---Number of cells, in millions; D---Dilution ratio,Undiluted is 1。 /... Read More | This product is a cDNA first strand synthesis kit specially prepared for the first step experiment of two-step RT-PCR. This product contains all the reagents required for reverse transcription from RNA templates to cDNA first strand, including HiFi MMLV reverse transcriptase, reaction buffer, This product is a cDNA first strand synthesis kit specially prepared for the first step experiment of two-step RT-PCR. This product contains all the reagents required for reverse transcription from RNA templates to cDNA first strand, including HiFi MMLV reverse transcriptase, reaction buffer, primers, dNTP, etc. The mutated HiFi MMLV reverse transcriptase RNase H activity is deficient, reducing RNA degradation in reverse transcription reactions and making it easier to obtain full-length cDNA. HiFi MMLV reverse transcriptase has strong thermal stability and can yield high yields of cDNA, making it simple and convenient to use. This system has high compatibility with subsequent PCR and quantitative PCR experiments, and is suitable for various DNA polymerase reactions. H665693 Component 100 T Storage H665693A HiFi-MMLV, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665693B 5×RT Buffer 500 µL -20℃. Avoid freeze/thaw cycle. H665693C Primer Mix 240 µL -20℃. Avoid freeze/thaw cycle. H665693D dNTP Mix, 2.5 mM Each 500 µL -20℃. Avoid freeze/thaw cycle. H665693E DTT, 0.1 M 240 µL -20℃. Avoid freeze/thaw cycle. H665693F RNase-Free Water 1 mL -20℃. Avoid freeze/thaw cycle. Product features:·RNase H -: Mutated HiFi MMLv reverse transcriptase with reduced RNase H activity, making it easier to obtain full-length cDNA.·Easy to use: The reagent kit contains all the reagents required for reverse transcription, except for RNA templates.Notes:1. During the operation process, RNase contamination should be avoided to prevent RNA degradation or cross contamination during experiments. It is recommended to perform RNA operations in specialized areas, use specialized instruments and consumables, and have operators wear masks and disposable gloves, and frequently change gloves.2. Disposable plastic containers should be used as much as possible for experiments. If glass containers are used, they should be treated with a 0.1% DEPC (diethyl pyrocarbonate) aqueous solution at 37 ℃ for 12 hours, and sterilized under high pressure at 120 ℃ for 30 minutes before use. Alternatively, glass containers should be sterilized under dry heat at 180 ℃ for 60 minutes before use. The sterile water used in the experiment should be treated with 0.1% DEPC and then subjected to high-pressure sterilization.3. All reagents in this reagent kit should be gently mixed upside down before use, avoiding foaming as much as possible, and used after brief centrifugation. The enzymes involved should be returned to -20 ℃ as soon as possible after use to avoid repeated freeze-thaw cycles.If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.Usage:Attention: 10 ng-5 µ G Total RNA can establish 20 µ Reaction system, if the total RNA content is greater than 5 µ g. Please expand the reaction system proportionallyi Steps for reverse transcription:1. Dissolve RNA templates, primers, dNTP Mix, DTT, RT Buffer, HiFi MMLV, and RNase Free Water and place on ice for later use.2. Prepare a reaction system according to the following table, with a total volume of 20 µ L. Reagent 20 µlReaction system Final concentration dNTP Mix,2.5 mM Each 4 µl 500 µM Each Primer Mix 2 µl / RNA Template X µl 1 ng-5 µg 5×RT Buffer 4 µl 1× DTT,0.1 M 2 µl 10 mM HiFi-MMLV,200 U/µl 1 µl / RNase-Free Water up to 20 µl / Attention:1) If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.2) Primer Mix is formulated from Oligo (dT) and Random Primer3. Vortex shake and mix well, briefly centrifuge to collect the solution on the pipe wall to the bottom of the pipe. 4. Incubate at 42 ℃ for 30-50 minutes and 85 ℃ for 5 minutes. After the reaction is complete, centrifuge briefly and cool on ice.5. Reverse transcripts can be directly used for PCR reactions and fluorescence quantitative PCR reactions, or stored at -20 ℃ for a long time.ii If the reverse transcription efficiency is low, or the RNA template secondary structure is complex and the GC content is high, the following steps are recommended:1. Dissolve RNA templates, primers, dNTP Mix, DTT, RT Buffer, HiFi MMLV, and RNase Free Water and place on ice for later use.2. Prepare the reaction system according to the following table, with a total volume of 13 µ L. Reagent 20 µlReaction system Final concentration dNTP Mix,2.5 mM Each 4 µl 500 µM Each Primer Mix 2 µl / RNA Template X µl 1 ng-5 µg RNase-Free Water up to 13 µl / 3. Incubate at 70 ℃ for 10 minutes and quickly ice bath for 2 minutes.4. Centrifuge briefly to collect the solution on the tube wall to the bottom of the tube.5. Continue to add the following reagents to the above reaction solution: Reagent 20 µlReaction system Final concentration 5×RT Buffer 4 µl 1× DTT,0.1 M 2 µl 10 mM HiFi-MMLV,200 U/µl 1 µl / Attention:1) If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.2) Primer Mix is formulated from Oligo (dT) and Random primer.6. Gently blow and mix well, incubate at 42 ℃ for 50 minutes, and incubate at 85 ℃ for 5 minutes.7. After the reaction is complete, centrifuge briefly and cool on ice.8. Reverse transcripts can be directly used for PCR reactions and fluorescence quantitative PCR reactions, or stored at -20 ℃ for a long time... Read More | N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917D DNA Standard B 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917E DNA Standard C 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917F DNA Standard D 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917G DNA Standard E 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis is a dye-based (SYBR Green I) qPCR NGS library quantification kit for cfDNA, which provides the reaction mixture, DNA primer mixture, standards, and sample dilutions required for the qPCR process, making it a complete reagent system that is easy and convenient to use. The fluorescent dye SYBR Green I contained in the reaction mixture binds to all double-stranded DNA. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, the length of the standard in the kit (about 270bp) is comparable to the average length of the cfDNA NGS libraries (250-300bp), which is able to quickly and accurately quantitate the concentration of the constructed cfDNA libraries. quantification.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.NOTE: High Rox and Low Rox are formulated as described in Method of Use 2.Applicable scopeThis product is designed for the absolute quantification of the concentration of Illumina platform second generation sequencing libraries. The end of the library contains Illumina P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.02pM can be used for quantitative experiments. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-60 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix0.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: 1 µl High Rox per 50 µl of reaction system; Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3.qPCR reaction programIf the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.Refer to the specific instrument setup program for dissolution curves.data analysisStandard curve productionThe standard curve was plotted according to the data processing Excel sheet. The correlation coefficient R2 of the standard curve should be not less than 0.99, and the slope should be located between -3.1 and -3.6 when the Ct value is the longitudinal coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard A60 pMDNA Standard B6 pMDNA Standard C0.6 pMDNA Standard D0.06 pMDNA Standard E0.006 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More | S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948D DNA Standard 2 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948E DNA Standard 3 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948F DNA Standard 4 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948G DNA Standard 5 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis product is used for real-time fluorescence quantitative PCR (qPCR) using the product after NGS library construction by dye method (SYBR Green I). The kit provides the reaction mixture, DNA primer mixture, and standards required for the qPCR process, and the reagent system is complete, easy and convenient to operate. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, and able to quickly and accurately quantify the concentration of the constructed library. It is suitable for fluorescent quantitative PCR instruments that do not require ROX as a calibration dye, such as Roche LightCycler 480, Roche LightCyler 96, Bio-radiCyleriQ, iQ5, CFX96.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Use 2.Scope of applicationThis product is designed for absolute quantification of the concentration of Illumina platform second-generation sequencing libraries. The end of the library contains Illumin P5 and P7 chip binding sequences, the length of which does not exceed 1kb, and the concentration of which is not less than 0.002pM can be used to perform quantitative experiments with this product. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-20 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR Master Mix10 µlqPCR Primer Mix 10.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: add 1 µl High Rox per 50 µl of reaction system;Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.qPCR reaction programThe annealing temperature should be 60-64°C as a reference for the setting range, and the annealing temperature can be increased when a non-specific reaction occurs.If the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.data analysisStandard curve productionThe standard curve was plotted using Ct values in the valid range. The standard curve correlation coefficient R2 should not be less than 0.99 and the slope should lie between -3.1 and -3.6. If the standard curve parameters are not reasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard 120 pMDNA Standard 22 pMDNA Standard 30.2 pMDNA Standard 40.02 pMDNA Standard 50.002 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More |