| Description | B665530 Component 50 T 200 T Storage B665530A Buffer RCL 125 mL 2×260 mL 2-8℃ B665530B Buffer GR 15 mL 50 mL RT B665530C Buffer GL 15 mL 50 mL RT B665530D Buffer GW1 (concentrate) 13 mL 52 mL RT B665530E Buffer GW2 (concentrate) 15 mL 50 mL RT B665530F Buffer GE 15 mL 60 mL RT B665530G B665530 Component 50 T 200 T Storage B665530A Buffer RCL 125 mL 2×260 mL 2-8℃ B665530B Buffer GR 15 mL 50 mL RT B665530C Buffer GL 15 mL 50 mL RT B665530D Buffer GW1 (concentrate) 13 mL 52 mL RT B665530E Buffer GW2 (concentrate) 15 mL 50 mL RT B665530F Buffer GE 15 mL 60 mL RT B665530G Proteinase K 1.25 mL 4×1.25 mL RT B665530H Spin Columns DM with Collection Tubes 50 sets 200 sets RTProduct IntroductionThis reagent kit is suitable for extracting total DNA, including genomic DNA, mitochondrial DNA, and viral DNA, from fresh or frozen whole blood (blood samples treated with anticoagulants such as citrate, EDTA, or heparin), plasma, serum, erythrocyte sedimentation rate brown layer, lymphocytes, cell-free body fluids, and other samples. This product can process 0.1-1 mL of whole blood with a maximum yield of 30% µ g. It can purify DNA with sizes ranging from 100 bp to 50 kb. The purified DNA has high yield and good quality, and can remove protein, pigment, lipid, and other inhibitory impurities to the maximum extent. It can be directly used for PCR, fluorescence quantitative PCR, enzyme digestion, and Southern Blot experiments.Self prepared reagent: anhydrous ethanol.Preparation and important precautions before the experiment:1. The sample should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2. This reagent kit can extract up to 0.1-1 mL of whole blood samples or 1 × 107 white blood cells.3.Before the first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in the Buffer GL. If there is any crystallization or precipitation, please incubate the Buffer GL in a 56 ℃ water bath and dissolve it again.5. The Buffer RCL in the reagent kit cannot be used again after being turbid.Operation steps:1. Sample processing: 1a When extracting 200 uL of blood sample, add the sample to the centrifuge tube (provided) and proceed directly to the next step of the experiment. 1b When the blood sample size is less than 200 µ When L, add Buffer GR to make up for 200 µ L. Proceed to the next step of the experiment. 1c When the blood sample size exceeds 200 µ When L is reached, add 1-2 times the volume of Buffer RCL, gently vortex or invert and mix well. Centrifuge at 12000 rpm (~13400 × g) for 1 minute and carefully discard the supernatant. If there is still red in the sediment, repeat the above steps once. Then add 200 to the precipitate µ Shake the buffer GR until thoroughly mixed before proceeding to the next step of the experiment. 1d If the processed blood sample is anticoagulant from poultry, birds, amphibians, or lower level organisms, its red blood cells are nucleated cells, and the blood sample size is 5-20 µ L. Can be added to Buffer GR to make up to 200 µ Follow up experiments will be conducted afterwards. Note: If downstream experiments are sensitive to RNA, 4 can be added µ L RNase A (100mg/mL) solution, shake for 15 seconds, and leave at room temperature for 5 minutes. RNase A reagent kit is not provided. If needed, you can order it separately from our company, item number: CW0601S.2. Add 20 to the above solution µ L Protein K, mix well.3. Add 200 µ Shake with L Buffer GL until thoroughly mixed. Note: Do not pre mix Protein K and Buffer GL.4.Incubate at 4.56 ℃ for 10 minutes, invert and mix several times during this time. Attention: The DNA production has reached its maximum after 10 minutes of incubation, and further extension of incubation time has no effect on DNA production and purity.5. Add 200 µ L anhydrous ethanol, invert and mix several times. Short centrifugation causes the liquid on the tube wall and wall cover to concentrate at the bottom of the tube.6. Add all the solution obtained in step 5 to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. Note: If the extracted sample is the blood genome of species such as mice or monkeys that are difficult to remove heme, it is recommended to repeat step 7.8. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. Note: To further improve DNA purity, repeat step 8.9.Centrifuge at 9.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.)10. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃. Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high. 2) If the final concentration of DNA needs to be increased, the obtained DNA eluent can be added back to the adsorption membrane, left at room temperature for 2-5 minutes, and centrifuged at 12000 rpm for 1 minute. 3) Because DNA stored in water is affected by acidic hydrolysis, if long-term storage is required, it is recommended to elute with Buffer GE and store at -20 ℃... Read More | D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H Buffer EB 4 mL RT D665729I Buffer PS 10 mL RT D665729J Spin Columns DF 50 Pcs 2-8 ℃ D665729K Collection Tubes 50 Pcs RTProduct Introduction:The basic principle of this reagent kit is that after DNA is treated with sodium bisulfite, unmethylated cytosine can be transformed into uracil, while methylated cytosine remains unchanged. And adopting an innovative high-temperature treatment method, the transformation time is greatly shortened, the transformation efficiency is improved, and the transformation efficiency can reach over 99%. At the same time, using a silicon-based membrane purification column, DNA can be recovered and purified from the methylated solution through a simple binding washing elution step. The recovered DNA has high purity and good integrity, and can be directly used for sequencing, methylated PCR detection, chip analysis, connection and transformation, enzyme digestion, labeling, microinjection, PCR and in vitro transcription and other molecular biology experiments.Self prepared reagents: anhydrous ethanol, 75% ethanol.Preparation and important precautions before the experiment1. Product usage method:(1) 10 times packaging preparation method: CT Conversion Agent is a solid mixture that must be prepared before first use. Add 2 ml sterile water and 100 µ M-Dissolving Buffer and 300 µ Add M-Diffusion Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 10 DNA treatments. In order to achieve better results, the prepared CT Conversion Agent should be used immediately. If not used immediately, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.(2) 50 times packaging preparation method: CT Conversion Agent and M-Dissolving Buffer are solid mixtures that must be prepared before first use. Add 5 ml of sterile water to the M-Dissolving Buffer and shake to dissolve. After all the solids have dissolved, transfer all the solution from the M-Dissolving Buffer tube to the CT Conversion Agent tube and add 5.5 ml of sterile water. Add 1.5 ml of M-Dilution Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 50 DNA treatments. In order to achieve better results, the CT Conversion Agent should be used immediately after preparation. If not immediately used, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.2. Before the first use, anhydrous ethanol should be added to the M-Wash Buffer according to the instructions on the reagent bottle label.Operation stepsThe range of DNA prepared each time is 1 ng-4 µ Between g, the optimal amount is 500 ng-2 µ G.1. Take 20 µ Add DNA sample into centrifuge tube (self provided), and if the sample amount is insufficient, replenish with water up to 20 µ L.2. Add 2.2 to the DNA sample µ Mix the sample well with the M-Dilution Buffer of l.3.42 ℃ water bath for 30 minutes.4. Add 220 to the sample obtained from the previous step µ Prepare the CT Conversion Agent solution, mix well, and incubate in an 80 ℃ constant temperature water bath in a dark place for 60 minutes.5. Add 480 to the solution in the previous step µ M - Buffer PA, gently mix upside down.6. Column balance: Add 200 to the spin columns DS that have been loaded into the collection tube µ Centrifuge at 12000 rpm (~13400 × g) for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7.Add all the solution obtained from step 5 to the adsorption column (already loaded into the collection tube), let it stand at room temperature for 2 minutes, centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Attention: The maximum capacity of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.8. Add 500 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute using M-Buffer PA, discard the waste liquid from the collection tube, and place the adsorption column in the recovery tube.9. Add 650 to the adsorption column µ M-Wash Buffer (please check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.10.12000 rpm for 2 minutes, discard the waste liquid, and place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column into a new centrifuge tube (provided by oneself), and add 20 drops to the middle position of the adsorption membrane in the air µ M-Elution Buffer (pH 8.5), leave at room temperature for 2 minutes. Collect DNA solution by centrifugation at 12000 rpm for 1 minute.12. Collect 20 µ Add 2.2 to DNA µ M-Diffusion Buffer, let it stand at room temperature for 30 minutes.13. Add 500 to the solution µ After pre cooling anhydrous ethanol, invert and mix well, and place the solution at -20 ℃ to precipitate for 30 minutes (overnight precipitation is more effective).14.12000 rpm for 15 minutes and gently discard the supernatant.15. Add 75% ethanol, centrifuge at 12000 rpm for 1 minute, pour out the supernatant, wait for ethanol to evaporate at room temperature, then add 20 µ Dissolve the M-Elution buffer and store the DNA at -20 ℃. The DNA collected in this step can be used for subsequent related experiments... Read More | H665581 Component 100 T Storage H665581A gDNA Eraser 50 µL -20℃. Avoid freeze/thaw cycle. H665581B 10×gDNA Eraser Buffer 120 µL -20℃. Avoid freeze/thaw cycle. H665581C HiFiScript, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665581D 5×ScriptRT H665581 Component 100 T Storage H665581A gDNA Eraser 50 µL -20℃. Avoid freeze/thaw cycle. H665581B 10×gDNA Eraser Buffer 120 µL -20℃. Avoid freeze/thaw cycle. H665581C HiFiScript, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665581D 5×ScriptRT Buffer 500 µL -20℃. Avoid freeze/thaw cycle. H665581E Primer Mix 120 µL -20℃. Avoid freeze/thaw cycle. H665581F RNase-Free Water 2×1 mL -20℃. Avoid freeze/thaw cycle.Product IntroductionThis product is a kit for removing genomic DNA for reverse transcription. The kit removes genomic DNA in 2 minutes at 42°C. Since the reverse transcription reagent contains a component that inhibits gDNA Eraser, cDNA can be synthesized directly by reverse transcription of gDNA Eraser-treated samples.The kit is equipped with a new high-efficiency reverse transcription enzyme, HiFiScript, with novel mutation sites that dramatically increase the transcriptional activity of the enzyme, resulting in higher efficiency and yield of cDNA first-strand synthesis. The first strand of cDNA can be synthesized with higher efficiency and yield, and the first strand of cDNA can be synthesized from pg total RNA or mRNA. If the reverse transcription product cDNA is used for downstream fluorescence quantitative detection, the reverse transcription reaction can be completed at 42℃ in 15 minutes. This kit is suitable for the synthesis of first-strand cDNA and subsequent RT-PCR, RT-qPCR, and the construction of full-length cDNA libraries.Product Features1. Rapid genome removal: contains gDNA Eraser for genomic DNA removal, which removes genomic DNA in just 2 minutes.2. Rapid reverse transcription: 15 minutes to obtain fluorescent quantitative PCR template cDNA first strand synthesis.3. High sensitivity: cDNA first strand can be synthesized using pg-level total RNA or mRNA templates.4. Highly efficient reverse transcription: Novel mutation sites dramatically increase enzyme activity, resulting in higher yields of cDNA.matters needing attention1. During operation, RNase contamination should be avoided to prevent RNA degradation or cross-contamination in the experiment. It is recommended that operators wear masks and disposable gloves and change the gloves frequently, and use specialized instruments and consumables.2. The reverse transcription system is prepared and operated on ice to prevent degradation of RNA. Store the kit enzymes at -20ºC as soon as possible after use and try to avoid repeated freezing and thawing.3. The reaction system can be scaled up to a maximum of 1 µg of total RNA in 10 µl of reaction system.4. Primer Mix is prepared by Oligo(dT) and Random primer, and Oligo-dT Primer or Gene Specific Primer can also be used according to the experimental needs.5. If the amount of starting RNA is less than 50ng, it is recommended to add RNAase inhibitor (RNasin).6. For RNA templates with complex secondary structures, it is recommended to incubate the template RNA at 65°C for 5 minutes immediately on ice prior to the manipulation step and centrifuge briefly before proceeding to the next step.UsageThaw template RNA on ice; place kit components on ice immediately after thawing at room temperature. Each solution was mixed by vortexing and shaking before use and briefly centrifuged.I. Genomic DNA removal reactions1. Prepare the reaction system according to the following table on ice in a total volume of 10 µl. To ensure the accuracy of the reaction solution preparation, prepare the premixed system in the amount of reaction number + 2 before dispensing it into each reaction tube and finally adding the RNA sample.Note: 1) If the amount of total RNA is greater than 1µg, scale up the reaction system proportionally. If the amount of starting RNA is less than 50ng, it is recommended to add RNAase inhibitor (RNasin).2. Mix by vortex shaking and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.3. Incubate at 42°C for 2 minutes (this can be extended to 30 minutes for room temperature reactions).4.At the end of the reaction, centrifuge briefly and place on ice to cool.II. Reverse transcription reaction1. Prepare the reaction system on ice according to the following table. In order to ensure the accuracy of the reaction solution configuration, first prepare a premixed solution in the amount of number + 2, and then dispense 10 µl into each reaction tube, take 10 µl of the prepared premixed solution and add it to the reaction tube of step 1 where the de-etching of the genome has been completed.Note: 1) Oligo-dT Primer or Gene Specific Primer can be used according to the needs of the experiment, it is recommended to use 50 pmol of Oligo-dT Primer or 2 pmol of Gene Specific Primer for 20 µl reaction system.2. Mix well and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.3. cDNA synthesis reaction conditions:1) If fluorescent quantitative PCR assay is performed downstream, incubate at 42°C for 15 minutes and 85°C for 5 minutes.2) If downstream for normal PCR assay, incubate at 42°C for 30-50 minutes and 85°C for 5 minutes. Note: For templates with complex secondary structure or high GC content, the reverse transcription temperature can be increased to 50°C to enhance reverse transcription efficiency.4. At the end of the reaction, centrifuge briefly and place on ice before proceeding with subsequent PCR or fluorescence quantitative PCR, or place at -20°C if prolonged storage is required.Note: When performing Real-time PCR reactions, the amount of reverse transcription product added should not exceed 1/10 of the total volume of the PCR reaction... Read More | DescriptionThe Baran Late-Stage Toolkit is a convenient collection of 12 highly innovative reagents that are highly effective in the diversification of complex molecules. The contents in the box are 11 Baran Diversinates™and one vial of Palau′Chlor®in amounts of 100 mg each. For DescriptionThe Baran Late-Stage Toolkit is a convenient collection of 12 highly innovative reagents that are highly effective in the diversification of complex molecules. The contents in the box are 11 Baran Diversinates™and one vial of Palau′Chlor®in amounts of 100 mg each. For obtaining larger amounts of any desired kit component, see the kit component table at the bottom of the page.Useful Topics:Late Stage FunctionalizationBaran Group – Professor Product PortalPalau′ChlorDiversinates... Read More | Inquire |