| Description | Product DescriptionOur Glycan Sequencing Kit includes the enzymes and buffer required to sequence ten N-linked oligosaccharides.ContentsNeuraminidase from Arthrobacter ureafaciens – 80 µlBeta-Galactosidase from Streptococcus pneumoniae – 60 µlN-Acetylglucosaminidase from Product DescriptionOur Glycan Sequencing Kit includes the enzymes and buffer required to sequence ten N-linked oligosaccharides.ContentsNeuraminidase from Arthrobacter ureafaciens – 80 µlBeta-Galactosidase from Streptococcus pneumoniae – 60 µlN-Acetylglucosaminidase from Streptococcus pneumoniae) – 40 µlAlpha-Mannosidase from Jack Bean – 20 µlCore Alpha-Mannosidase from X. manihotis) – 10 µl5X Reaction buffer – 400 µlAnalysisMany methods of analysis are available, including HPLC, gel electrophoresis, HPAEC, capillary electrophoresis, and mass spectrometry. For more information on these methods, please contact us.StabilityThe Glycan Sequencing Kit is stable at least 12 months when stored properly. Several days exposure to ambient temperatures will not reduce activity.PurityAll Enzymes are tested for contaminating protease by incubating 10 µg of denatured BSA with 2 µl of enzyme at 37°C for 24 hours. SDS-PAGE analysis of the treated BSA shows no evidence of degradation.The production host strains for our recombinant enzymes have been extensively tested and do not produce any detectable glycosidases. Enzymes purified from native sources are tested for contaminating exoglycosidases The absence of exoglycosidase contaminants is confirmed by extended incubations with the corresponding pNP-glycosides... Read More | Product content N665859Component50 TStorageN665859ABuffer DS30 mLRTN665859BBuffer GTL15 mLRTN665859CBuffer GL15 mLRTN665859DBuffer GW1 (concentrate)13 mLRTN665859EBuffer GW2 (concentrate)15 mLRTN665859FBuffer TE10 mLRTN665859GProteinase K2×1.25 mLRTN665859HRNase A (100 mg/mL)0.4 Product content N665859Component50 TStorageN665859ABuffer DS30 mLRTN665859BBuffer GTL15 mLRTN665859CBuffer GL15 mLRTN665859DBuffer GW1 (concentrate)13 mLRTN665859EBuffer GW2 (concentrate)15 mLRTN665859FBuffer TE10 mLRTN665859GProteinase K2×1.25 mLRTN665859HRNase A (100 mg/mL)0.4 mLRTN665859ISpin Columns DF With Collection Tubes50 EA2-8℃N665859JCentrifuge Tubes (L-1.5 mL)50 EART Product IntroductionThis kit is suitable for the effective purification of genomic DNA from formalin-fixed, paraffin-embedded tissues.The product uses specially optimized dewaxing agent and lysis solution to release DNA from formalin-fixed or tissue sectioned samples, which does not involve the organic reagent xylene and does not need to be operated overnight; the digested samples are incubated at higher temperatures to remove formalin cross-linking of the free DNA, which can effectively improve the yield and purity of DNA; the optimized buffer system allows the inhibitors in the lysis solution to be specifically bound to the adsorbent membrane, which can be effectively removed by a two-step rinsing step. The optimized buffer system enables the DNA in the lysate to specifically bind to the adsorbent membrane, and the inhibitor is effectively removed by a two-step rinsing step, and finally eluted with low-salt buffer or water to obtain high-purity DNA.Meanwhile, configured with a high-efficiency microsorbent column, the elution volume can be as low as 20 µL.The purified DNA can be directly used for PCR, Real-time PCR, SNP Genotyping, STR genotyping, second-generation sequencing and pharmacogenomics research.The molecular weight of DNA isolated from formalin-fixed, paraffin-embedded samples is usually lower than that of DNA from fresh or frozen samples.The degree of DNA fragmentation depends on the type of sample, the duration of storage, and the conditions of fixation.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. After obtaining the sample, fix the sample in 4%-10% formalin as soon as possible, the fixation time should be 14-24 hours, too long a period of time will easily lead to genome breakage, affecting the downstream experiments. If the formaldehyde fixation time is too long or the sample has been stored for too long (> 1 year), it will easily lead to DNA integrity damage and unable to amplify long fragments.2. Ensure that the sample is thoroughly dehydrated before embedding; residual formalin will inhibit Proteinase K.3. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.4. Before use, please check Buffer GTL, Buffer GL and Buffer DS for any crystallization or precipitation. If there is any crystallization or precipitation, please re-dissolve Buffer GTL, Buffer GL and Buffer DS at 56℃ in a water bath.5. Preheat the water bath or thermostatic mixer to 56°C and keep the centrifuge at 25°C before starting the experiment.6. If downstream experiments are needed to reduce the low frequency of C>T:G>A transitions (artificial mutations) that occur to minimize the risk of false positives, 7 µL of UNG (1 U/uL) can be added after 1 hour of incubation at 90°C.Operation steps1. Sample processing:1a. Paraffin-embedded samples: Trim off excess paraffin from the tissue block with a scalpel to expose the tissue and then cut into 5-10µm slices. Take about 1×1cm2 slices (about 4-5 slices in total) and place them in a centrifuge tube (provided), add 160µL Buffer DS, vortex and shake for 10 seconds, then add 180µL Buffer GTL and 20µL Proteinase K, vortex and shake for 10 seconds. centrifuge the samples at 12,000rpm for 1 minute at 25℃.Note: 1) If the surface of the sample has been exposed to air, discard the 2-3 pieces that have been exposed to air and do not use them.2) DS will solidify below 18°C, and if it does it does not affect the following experiments.1b. Sample in formalin and other fixative: take about 20mg of sample, cut it into small pieces, place it in a centrifuge tube, add 500µL of 10mM PBS (PH7.4), vortex shaking, centrifuge at 12,000rpm for 1minute, discard the supernatant, and repeat 3 times. Add 180 µL Buffer GTL, 20 µL Proteinase K, vortex shaking to mix.2.56°C for 1 hour until the sample is completely dissolved. incubate at 90°C for 1 hour. centrifuge at 12,000 rpm, 25°C for 1 minute, and carefully pipette the lower aqueous phase (~180 µL) along the wall of the tube into a new centrifuge tube, trying to avoid aspirating the bottom precipitate and the upper layer of the wax solution.Note: 1) Samples can be left at room temperature after incubation at 56°C until the temperature of the water or dry bath reaches 90°C before placing the samples at 90°CIncubation.2) Optional step: add 7µL UNG (1U/µL), 50°C, 5min, no shaking. The purpose of this step is to minimize the risk of false positives by reducing the low-frequency occurrence of C>T:G>A transitions (artificial mutations) while effectively retaining the true occurrence of mutations.3. Optional step: If you need to remove RNA, you can lower the temperature of the sample to room temperature, then add 2µL of RNase A solution at a concentration of 100mg/mL, shake and mix well, and leave it at room temperature for 2 minutes.4. Add 20µL Proteinase K and incubate at 65℃, 450rpm for 15min.5. Add 200 µL of Buffer GL, mix well by vortexing and shaking, then add 200 µL of anhydrous ethanol and mix thoroughly by vortexing and shaking. Centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube.Note: 1) Mix well immediately after adding Buffer GL and anhydrous ethanol.2) The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.3) If more than one sample needs to be manipulated, the Buffer GL and anhydrous ethanol can be pre-mixed and spiked.6. Add all the solution obtained in step 5 to the adsorption columns (Spin Columns DF) that have been loaded into the collection tube, centrifuge at 25℃, 12000rpm for 2 minutes, pour out the waste liquid in the collection tube, and put the adsorption columns back into the collection tube.7. Add 500µL of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.8. Add 500µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12000rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 8 can be repeated if further DNA purity is required.9.12 Centrifuge at 2000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions.10. Place the adsorption column in a new 1.5 mL collection tube, add 20-100 µL of Buffer TE or sterilized water to the middle of the adsorption column overhanging the column, let it stand at room temperature for 2-5 minutes, centrifuge it at 12,000 rpm for 1 minute, and collect the DNA solution.-20°C to preserve DNA.Note: 1) The pH value of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH value is 7.0-8.5, the pH value is lower than 7.0 when the elution efficiency is not high.2) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 10 can be re-spiked onto the adsorbent membrane and left at room temperature for 2 minutes and centrifuged at 12,000 rpm for 1 minute... Read More | O665690 Component 50T Storage O665690A DNase I 1000 U -20℃.Avoid freeze/thaw cycle. O665690B 10×Reaction Buffer 1000 µL -20℃.Avoid freeze/thaw cycle. O665690C Buffer RLS 40 mL RT O665690D Buffer RW1 40 mL RT O665690E Buffer RW2 (concentrate) 11 mL RT O665690F RNase-Free Water O665690 Component 50T Storage O665690A DNase I 1000 U -20℃.Avoid freeze/thaw cycle. O665690B 10×Reaction Buffer 1000 µL -20℃.Avoid freeze/thaw cycle. O665690C Buffer RLS 40 mL RT O665690D Buffer RW1 40 mL RT O665690E Buffer RW2 (concentrate) 11 mL RT O665690F RNase-Free Water 10 mL RT O665690G Spin Columns FS with Collection Tubes 50 EA RT O665690H Spin Columns RM with Collection Tubes 50 EA RT O665690I RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTProduct IntroductionThis kit is suitable for extracting RNA from a wide range of plants, even from plants rich in polysaccharides and polyphenols, high quality RNA can be successfully extracted, such as rice leaves, wheat leaves, corn leaves, tobacco leaves, pine needles, ginkgo leaves, poplar leaves, pomegranate leaves, holly leaves, apples, peaches, pears, tomatoes, cherries, apricots, bananas, grapes, loquats, cinnamon rinds, cinnamon pulp, lychee fruit rinds, lychee pulp, soybean, peanut, corn, potato tuber, moonflower petal, pomegranate petal, shiitake mushroom, flat mushroom and other samples. The unique lysate formula can rapidly inactivate the RNA enzyme in the cell, effectively remove the effect of polysaccharide and polyphenol on RNA extraction, without the need for phenol, chloroform and other reagents, while using silicon matrix membrane adsorption of RNA for purification, the total RNA extracted is highly pure, without the contamination of genomes, proteins and other impurities, and can be used for Real Time RT-PCR, RT-PCR, It can be used for Real Time RT-PCR, RT-PCR, Northern Blot, Dot Blot, in vitro translation and other downstream experiments.RNA yieldSelf-contained reagents: β-mercaptoethanol, anhydrous ethanol (freshly opened or for RNA extraction)Pre-experiment Preparation and Important Notes1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips.(2) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.2. Avoid repeated freezing and thawing of the extracted samples, otherwise it will affect the rate and quality of RNA extraction.3. If Buffer RLS produces a precipitate, heat to dissolve it and leave at room temperature.4. Please add β-mercaptoethanol to Buffer RLS before use, add 20µl β-mercaptoethanol to 1ml Buffer RLS. Buffer RLS with β-mercaptoethanol can be stored for 1 month at room temperature.5. Anhydrous ethanol should be added according to the instructions on the reagent bottle label before using Buffer RW2 for the first time. Operation steps1. Homogenization: Take 50-100mg of plant tissue and quickly grind it into powder in liquid nitrogen, add 500µl of Buffer RLS (please check whether β-mercaptoethanol is added before use), and immediately mix it by vortexing with vigorous shaking.Note: For materials that are extremely rich in water content, such as watermelon pulp, tomato, pear pulp, etc., more material can be added appropriately, up to 200 mg; for starch-rich samples or mature leaves, the amount of Buffer RLS can be increased appropriately, up to 700 µl.2. Centrifuge at 12,000 rpm (~13,400 x g) for 2 min at 4°C.3. Transfer the supernatant into the filter columns (Spin Columns FS) that have been loaded into the collection tubes, centrifuge at 12,000 rpm at 4°C for 1 minute, carefully aspirate the supernatant in the collection tubes and transfer it to new RNase-Free centrifugation tubes (self-provided), avoiding the tip of the gun from touching the cell debris precipitation in the collection tubes as much as possible.4. Slowly add 0.5 times the volume of the supernatant in anhydrous ethanol, mix well (a precipitate may appear), and transfer the resulting solution together with the precipitate to a Spin Columns RM in a collection tube, or in two batches if you cannot add all of the solution at once. centrifuge the column for 1 minute at 12,000 rpm at 4°C. Dispose of the spent solution and place the column back into the collection tube. Centrifuge at 12,000 rpm for 1 minute at 4°C, discard the spent solution and return the column to the collection tube.5. Add 350 µl of Buffer RW1 to the adsorbent column RM, centrifuge at 12,000 rpm at 4°C for 1 min, discard the waste solution and put the adsorbent column back into the collection tube.6. Preparation of DNase I mixture: Take 52µl of RNase-Free Water, add 8µl of 10×Reaction Buffer and 20µl of DNase I (1U/µl) to it, mix well, and prepare a final volume of 80µl of reaction solution.7. Add 80µl of DNase I mixture directly to the adsorption column and incubate at 20-30°C for 15 minutes.8. Add 350 µl of Buffer RW1 to the adsorbent column RM, centrifuge at 12,000 rpm at 4°C for 1 min, discard the waste solution and put the adsorbent column back into the collection tube.9. Add 500 µl of Buffer RW2 to the adsorbent column RM (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 1 minute at 4°C, discard the waste solution and put the adsorbent column back into the collection tube.10. Repeat step 9.11. Centrifuge at 12,000 rpm for 2 minutes at 4°C.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (zymography, PCR, etc.).12. Load the adsorption column RM into new RNase-Free Centrifuge Tubes (1.5 ml), add 30-50 µl of RNase-Free Water dropwise to the middle part of the adsorption membrane overhang, leave it at room temperature for 2 min, and centrifuge at 12,000 rpm at 4°C for 1 min, and store the resulting RNA solution at -70°C to prevent degradation.Note: 1) The volume of RNase-Free Water should not be less than 30 µl, too small volume affects the recovery rate.2) If you want to increase the RNA yield, repeat step 12 with 30-50 µl of fresh RNase-Free Water.3) If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 12 repeated... Read More | RAFT Agent Kit for controlling polymerizations at the molecular level detailed list of products: Catalog Number Product Name Component Catalog Number Component Name Component CAS Specification&Purity R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C139356-500mg 4-RAFT Agent Kit for controlling polymerizations at the molecular level detailed list of products: Catalog Number Product Name Component Catalog Number Component Name Component CAS Specification&Purity R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C139356-500mg 4-Cyano-4-(dodecylsulfanylthiocarbonyl)sulfanylpentanoic acid 870196-80-8 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C396701-500mg Cyanomethyl dodecyl trithiocarbonate 796045-97-1 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C396703-500mg Cyanomethyl methyl(phenyl)carbamodithioate 76926-16-4 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C168358-500mg 2-Cyano-2-propyl benzodithioate 201611-85-0 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C396706-500mg 2-(2-Cyanoprop-2-yl)-S-dodecyltrithiocarbonate 870196-83-1 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C132316-500mg 4-Cyano-4-(phenylcarbonothioylthio)pentanoic Acid 201611-92-9 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level S396708-500mg S,S-Dibenzyl trithiocarbonate 26504-29-0 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level D396711-500mg 2-(Dodecylthiocarbonothioylthio)-2-methylpropionic acid 461642-78-4 See Component Catalog Number... Read More | Product Content R669990Component50 TStorageR669990ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669990B10×Reaction Buffer1 mL-20℃. Avoid freeze/thaw cycle.R669990CBuffer RL35 mLRTR669990DBuffer RW135 mLRTR669990EBuffer RW2 (concentrate)11 mLRTR669990FRNase-Free Water10 Product Content R669990Component50 TStorageR669990ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669990B10×Reaction Buffer1 mL-20℃. Avoid freeze/thaw cycle.R669990CBuffer RL35 mLRTR669990DBuffer RW135 mLRTR669990EBuffer RW2 (concentrate)11 mLRTR669990FRNase-Free Water10 mLRTR669990GSpin Columns RM with Collection Tubes50 setsRTR669990HRNase-Free Centrifuge Tubes (1.5 mL)50 EART ProductsThis kit combines highly efficient guanidine isothiocyanate cleavage technology with silica matrix membrane purification for the efficient extraction of total RNA from animal cells and tissues, typically up to 30 mg of tissue or 1x107 cells as a starting sample. The kit also allows recovery of incompletely purified RNA, in vitro transcription and RNA from enzymatic reactions. high quality RNA with molecular weights greater than 200 bases can be extracted and purified using the kit with virtually no DNA residue. If RNA experiments that are very sensitive to trace DNA are to be performed, residual DNA can be removed by on-column digestion using RNase-free DNase. The extracted RNA can be used in downstream experiments such as RT-PCR, Nothern Blot and Dot Blot. Self-contained reagents: β-mercaptoethanol, anhydrous ethanol (freshly opened or for RNA extraction).Pre-experiment Preparation and Important Notes1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.2) RNase-free water should be used to prepare the solution.(3) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.2. Avoid repeated freezing and thawing of the extracted samples, otherwise it will affect the amount and quality of RNA extraction.3. Please add β-mercaptoethanol to Buffer RL before use, add 10µl of β-mercaptoethanol to 1ml of Buffer RL. Buffer RL with β-mercaptoethanol can be stored for 1 month at room temperature.4. Anhydrous ethanol should be added to Buffer RW2 before first use according to the instructions on the reagent bottle label.5. Buffer RL may be heated at 56°C to dissolve if precipitation occurs and then left at room temperature.All centrifugation steps are performed at room temperature and all maneuvers are performed quickly.Procedure1. Sample handling1a Tissue: Grind tissue in liquid nitrogen. Add 600 µl Buffer RL for every 20-30 mg of tissue (check for addition of β-mercaptoethanol before use), and 350 µl Buffer RL for tissue samples of less than 20 mg. Sample volume is not to exceed one-tenth of the Buffer RL volume.1b Cells in monolayer culture: Lysed or processed into cell suspension directly in culture flask, centrifuged to obtain cell precipitate, discarded the supernatant, added 600µl Buffer RL for every 6-10 cm2 of culture area, 350µl Buffer RL for less than 6cm2, and blown several times repeatedly to make the cells lysed sufficiently.1c Cell suspension: centrifuge at 12,000 rpm (~13,400 × g) for 1 min and discard the supernatant to obtain the cell precipitate. Add 600 µl Buffer RL for every 5×106-1×107 cells, and 350 µl Buffer RL for less than 5×106 cells, and blow several times repeatedly to fully lysate.Note: 1) Try to get rid of the cell culture medium, which may inhibit cell lysis affecting RNA yield.2) Try to keep the cells well suspended and well lysed, otherwise RNA yield is affected.2. After the sample is fully lysed, leave it at room temperature for 5 minutes to allow complete separation of the protein-nucleic acid complex.3. Centrifuge at 12,000 rpm for 2-5 min and remove the supernatant for the following operations.4. Add 1x volume (600µl or 350µl) of 70% ethanol (prepared without RNase water) to the solution obtained in step 3 and mix well.Note: The addition of ethanol may produce a precipitate that will not affect subsequent experiments.5. Add all of the solution obtained in the previous step to the Spin Columns RM in the collection tube. If you cannot add all of the solution to the column at once, transfer it in two passes, centrifuge at 12,000 rpm for 1 minute, and discard the waste solution. Place the column back into the collection tube.Note: The maximum loading capacity of the adsorption column is 100µg, do not overload as this will affect the yield and purity of the RNA.6. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, discard the waste liquid and put the adsorbent column back into the collection tube.7. Preparation of DNase I mixture: Take 52 µl of RNase-Free Water, add 8 µl of 10×Reaction Buffer and 20 µl of DNase I (1 U/µl) to it, mix well, and prepare a final volume of 80 µl of reaction solution.8. Add 80µl of DNase I mixture directly to the adsorption column and incubate at 20-30°C for 15 minutes.9. Add 200 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, discard the waste liquid and put the adsorbent column back into the collection tube.10. Add 500µl Buffer RW2 to the column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the column back into the collection tube.11. Repeat step 10.12. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for a few minutes to thoroughly dry the anhydrous ethanol in the adsorption column.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).13. Transfer the adsorbent column into a new centrifuge tube, add 30-50 µl of RNase-Free Water to the middle of the adsorbent membrane, leave it at room temperature for 1 min, centrifuge at 12,000 rpm for 1 min, collect the RNA solution, and store the RNA at -70°C to prevent degradation.Note: 1) The volume of RNase-Free Wate should not be less than 30 µl, too small volume affects the recovery rate.2) If you want to increase the RNA yield, repeat step 13 with 30-50 µl of fresh RNase-Free Water.3) If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 13 repeated... Read More |