| Description | Products contentProducts IntroductionThe Single Cell Whole Genome Amplification Kit can be used as a template for whole genome amplification of single cells or micro samples. The total time for single-cell amplification is about 3 hours, and 2-5 µg of genomic DNA, with a size of 200-1500 bp, Products contentProducts IntroductionThe Single Cell Whole Genome Amplification Kit can be used as a template for whole genome amplification of single cells or micro samples. The total time for single-cell amplification is about 3 hours, and 2-5 µg of genomic DNA, with a size of 200-1500 bp, can be obtained after lysis, pre-amplification and amplification. The amplified product can be widely used in second-generation sequencing, large fragment copy number variation analysis, SNP typing, qPCR analysis and gene chip analysis.Bring your own instruments and reagentsPCR instrument Reaction tubes: low adsorption tubes recommended Gun Heads: High quality filtered gun heads are recommended Microcentrifuge, vortex mixercaveat The sensitivity of this product is very high, the experimental operation should be completed in a positive pressure ultra-clean bench or clean environment, the concentration of the amplification reaction products is high, should be well isolated to avoid aerosol contamination caused by amplification products.Operation flow diagramprocedurePre-experiment preparationSingle cells were obtained by flow cytometry sorting, buffer dilution, micromanipulation and laser microdissection. It is recommended that the cells be washed prior to the experiments with a 1× PBS solution free of Mg2+ and Ca2+, taking care to ensure that the volume of PBS solution in subsequent experiments does not exceed 2 µl. take note of Since the whole experiment is carried out in the same PCR tube and the reaction volume is small, the pipette tip should not touch the liquid in the tube when adding liquid, so as to avoid taking single cells or DNA out of the reaction system; when pipetting, please add the liquid along the wall of the tube carefully and do not blow the liquid in the PCR tube; before the reaction, please centrifuge briefly to make sure that the liquid in the reaction system is mixed evenly. Thaw the cell lysate, pre-amplifier and amplifier on ice before use.cell lysis 1)Mix Cell Lysis Buffer and Cell Lysis Enzyme according to the number of reactions N, shake to mix, centrifuge briefly and set aside.2)Mix single cells with the cell lysis mix in a PCR tube and run the following program.2. Pre-amplification reaction1)Mix Cell Lysis Buffer and Cell Lysis Enzyme according to the number of reactions N, shake to mix, centrifuge briefly and set aside.2)Add 5 µl of pre-amplification mix to 10 µl of lysis reaction product from the previous step and run the following program. 3. Amplification reaction1)Mix Amplification Buffer and Amp Enzyme Mix according to the number of reactions N, mix with shaking, centrifuge briefly and set aside.2)Add 60 µl of amplification mix to 15 µl of pre-amplification reaction product from the previous step and run the following program.Note: The number of cycles can be adjusted as needed, 14 cycles are recommended for single cells obtained by flow sorting, etc.Amplification product detection 1. Agarose gel electrophoresis 5 µl of the amplified product was subjected to agarose gel electrophoresis (1% agarose gel, 110 V, 25-35 min), and the amplified product was 200-1500 bp in size. 2. Quantitative Amplification products were subjected to magnetic bead or column purification, and purified products were quantified using Qubit with a final yield of 2-5 µg... Read More | Inquire | Product content:D665967Component200 TStorageD665967ABuffer PB120 mLRTD665967BBuffer PS60 mLRTD665967CBuffer PW (concentrate)25 mLRTD665967DBuffer EB30 mLRTD665967ESpin Columns DM with Collection Tubes200 EART Product Introduction: This reagent kit adopts a new silicon-based membrane technology and Product content:D665967Component200 TStorageD665967ABuffer PB120 mLRTD665967BBuffer PS60 mLRTD665967CBuffer PW (concentrate)25 mLRTD665967DBuffer EB30 mLRTD665967ESpin Columns DM with Collection Tubes200 EART Product Introduction: This reagent kit adopts a new silicon-based membrane technology and reagent formula. Through a rapid and simple three-step process of binding, washing, and elution, 100 bp-10 kb DNA fragments can be purified and recovered from PCR products or enzyme reaction solutions (enzyme cutting, linking, probe labeling, etc.). Each adsorption column can adsorb up to 10 kb of DNA fragments µ G DNA, while minimizing impurities such as primers, oligonucleotides, enzymes, etc. The purified and recovered DNA has high purity and concentration, good integrity, and high recovery rate, and can be directly used for molecular biology experiments such as sequencing, linking and transformation, labeling, and in vitro transcription.Self prepared reagent: anhydrous ethanol.Preparation and important precautions before the experiment:1. All components can be stably stored in a dry, room temperature (15-30 ℃) environment for 1 year, and can be stored at 2-8 ℃ for longer periods of time. When the solution is stored at low temperature, it should be left at room temperature for a period of time before use, and then restored to room temperature before use.2. This reagent kit can selectively recover all DNA fragments from the solution. If you need to selectively recover specific fragments while removing other fragments of different sizes, please choose our company's gel recovery reagent kit.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in the Buffer PB. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. The recovery efficiency is related to the initial amount of DNA and the elution volume. The smaller the initial amount, the smaller the elution volume, and the lower the recovery rate.6. All centrifugation steps can be performed at room temperature.Operation steps:1. Estimate the volume of DNA reaction solution, add 5 times the volume of Buffer PB, and mix thoroughly (without removing paraffin or mineral oil).Note: 1) If the DNA reaction system is 50 µ l (excluding paraffin oil volume), add 250 µ l Buffer PB.2) After adding Buffer PB, check the pH value of the solution. If the pH value is greater than 7.5, add 10-30 to it µ 3 M sodium acetate (pH 5.0) was used to adjust the pH value to 5-7.2. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ Centrifuge at 13000 rpm (~16200 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.3. Add the solution obtained in step 1 to the adsorption column that has been loaded into the collection tube, let it stand at room temperature for 1 minute, centrifuge at 13000 rpm for 30-60 seconds, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Attention: The volume of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ l, it can be added in batches.4. Add 500 µ l of Buffer PW to the adsorption column (please check if anhydrous ethanol has been added before use), centrifuge at 13000 rpm for 30-60 seconds, discard the waste liquid in the collection tube, and place the adsorption column in the recovery tube.Note: If purified DNA is used for salt sensitivity experiments (such as flat end ligation experiments or direct sequencing), it is recommended to add Buffer PW and let it stand for 2-5 minutes before centrifugation.5.13000 rpm for 1 minute and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.). To ensure that downstream experiments are not affected by residual ethanol, it is recommended to open the cover of the adsorption column and place it at room temperature for a few minutes to thoroughly dry the residual ethanol in the adsorbent material at the bottom.6. Place the adsorption column into a new centrifuge tube (provided by oneself), add 30-50 µ l Buffer EB to the middle position of the adsorption membrane by hanging droplets, and let it stand at room temperature for 1 minute. Centrifuge at 13000 rpm for 1 minute and collect DNA solution- Store DNA at 20 ℃.Attention:1) The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (the pH value of water can be adjusted to this range using NaOH).2) To improve the recovery of DNA, the solution obtained by centrifugation can be added back to the adsorption column, left at room temperature for 2 minutes, and centrifuged at 13000 rpm for 1 minute.3) The elution volume should not be less than 30 µ l. A small volume will affect the recovery efficiency... Read More | Inquire | This reagent kit is specially developed for one-step RT-PCR experiments. Reverse transcription and PCR are carried out in the same reaction system, without the need to add reagents or open the tube cap during the reaction process, which improves detection sensitivity and experimental efficiency This reagent kit is specially developed for one-step RT-PCR experiments. Reverse transcription and PCR are carried out in the same reaction system, without the need to add reagents or open the tube cap during the reaction process, which improves detection sensitivity and experimental efficiency while avoiding contamination. This kit includes a brand new high-efficiency reverse transcriptase, a fast hot start DNA polymerase, as well as reaction buffer suitable for reverse transcription and PCR amplification, and other components necessary for the experiment. The loss of activity of SuperRT reverse transcriptase RNase H reduces RNA degradation in reverse transcription reactions. This reverse enzyme has high reverse transcription efficiency and can perform good reverse transcription reactions on a small amount of RNA templates. The rapid hot start DNA polymerase used in PCR reaction has excellent performance of high amplification efficiency, strong specificity, and fast extension speed. The unique buffering system maximizes the efficiency of both reverse transcriptase and polymerase. The target product amplified using this reagent kit has an A base attached to the 3 'end, which can be directly used for T/A cloning.S665660Component100 TStorageS665660ASuperRT OneStep EnzymeMix50 µL-20℃. Avoid freeze/thaw cycle.S665660B2×SuperRT OneStep Buffer1.4 mL-20℃. Avoid freeze/thaw cycle.S665660CRNase-Free Water1.5 mL-20℃. Avoid freeze/thaw cycle. Notes:1. During the operation process, RNase contamination should be avoided to prevent RNA degradation or cross contamination during experiments. It is recommended to perform RNA operations in specialized areas, use specialized instruments and consumables, and have operators wear masks and disposable gloves, and frequently change gloves.2. Disposable plastic containers should be used as much as possible for experiments. If glass containers are used, they should be treated with a 0.1% DEPC (diethyl pyrocarbonate) aqueous solution at 37 ℃ for 12 hours, and sterilized under high pressure at 120 ℃ for 30 minutes before use. Alternatively, glass containers should be sterilized under dry heat at 180 ℃ for 60 minutes before use. The sterile water used in the experiment should be treated with 0.1% DEPC and then subjected to high-pressure sterilization.3. All reagents in this reagent kit should be gently mixed upside down before use, avoiding foaming as much as possible, and used after brief centrifugation. The enzymes involved should be returned to -20 ℃ as soon as possible after use to avoid repeated freeze-thaw cycles.4. This reagent kit must use specific primers, and the selection of primers can be based on specific experiments. The quality of primer design directly affects the results of RT-PCR reactions. When designing primers, factors such as GC content, primer length, primer position, and the secondary structure of PCR products need to be considered. It is recommended to use professional primer design software.Usage:1. Dissolve the RNA template, primers, OneStep RT-PCR Buffer, SuperRT OneStep RT-PCR EnzymeMix, and RNase Free Water and place them on ice for later use.2. Prepare the reaction system according to the following table: Reagent 25 µlReaction system Final concentration 2×SuperRT OneStep Buffer 12.5 µl 1× Forward Primer,10 µM 1 µl 0.4 µM Reverse Primer,10 µM 1 µl 0.4 µM SuperRT OneStep EnzymeMix 0.5 µl / RNA Template X µl 1 pg – 1 µg RNase-Free Water up to 25 µl / Attention: The primer concentration should be between 0.1 and 1.0 as the final concentration µ M serves as a reference for setting the range. In the case of low amplification efficiency, the concentration of primers can be increased; When non-specific reactions occur, the primer concentration can be reduced to optimize the reaction system.3. Vortex and shake well, centrifuge briefly, and collect the solution to the bottom of the tube.4. Preheat the thermal cycler to 45 ℃, place the PCR tube in the thermal cycler, and perform RT-PCR reaction.Reaction conditions: Step Temperature Time / Reverse transcription 45℃ 30 min / PCR pre denaturation 95℃ 2 min Denaturation 94℃ 30 s 30-40 cycles Anneal 55-65℃ 30 s 30-40 cycles Extend 72℃ 30 s 30-40 cycles Finally extended 72℃ 5 min /Attention:1) In general PCR experiments, the annealing temperature is 5 ℃ lower than the melting temperature Tm of the amplification primer, and the annealing time is generally 20-30 seconds. If the ideal amplification efficiency cannot be achieved, the annealing temperature should be appropriately reduced; When non-specific reactions occur, increase the annealing temperature to optimize the reaction conditions.2) The extension time is set based on the size of the amplified fragments, and the DNA Polymerase amplification efficiency contained in this product is 1 kb/30s.3) The number of cycles can be set based on the downstream application of the amplification product. Too few cycles, insufficient amplification; Multiple cycles increase the probability of mismatches and result in severe non-specific backgrounds. Therefore, while ensuring product yield, the number of cycles should be minimized as much as possible.5. After the reaction is complete, take 5 µ l of the reaction product, add an appropriate amount of loading buffer, and perform electrophoresis detection results... Read More |