| Description | Product content: Component O66550510 preps O665505 50 preps Blocking Buffer 100 ml 500 ml Antibody Pretreat Solution( HRP/Mouse ) 1 ml 5 × 1 ml Dilution Buffer 100 ml 500 ml Wash Buffer( 10× ) 100 ml 500 mlProduct Introduction:The one-step rapid WB assay kit (Product content: Component O66550510 preps O665505 50 preps Blocking Buffer 100 ml 500 ml Antibody Pretreat Solution( HRP/Mouse ) 1 ml 5 × 1 ml Dilution Buffer 100 ml 500 ml Wash Buffer( 10× ) 100 ml 500 mlProduct Introduction:The one-step rapid WB assay kit (mouse) is the latest Western Blot detection kit developed by Kangwei Century, which can obtain high-quality Western Blot results in about 1 hour. It is easy to operate, has high detection sensitivity, low background, does not require the addition of secondary antibodies, and has strong system stability. The conventional Western Blot indirect detection process (blocking, primary antibody binding, and secondary antibody binding) requires a long time, a complex experimental process, and requires multi-step condition optimization. After transferring the protein on the gel to the carrier membrane, incubate it with the blocking solution in the reagent kit for 5 minutes, and then incubate the carrier membrane with the primary antibody treated with antibody reaction solution. After washing three times (5 minutes each time), luminescence or colorimetric detection can be performed. This reagent kit is designed for use in experimental systems where the target protein primary antibody is derived from mice.Notes:1. The customer prepares their own mouse source primary antibody.2. Before using Blocking Buffer blocking solution, Antibody Pretreat Solution (HRP/Mouse) antibody reaction solution (mouse), and Wash Buffer (10 x) rinse solution, please mix thoroughly.3. If there is precipitation in the rinsing solution when stored at 2-8 ℃, please restore it to room temperature, dissolve the precipitation, and use it normally. The 1x rinsing solution can be stored at room temperature for one month.4. It is recommended to stain the membrane with reagents such as spring red after the transfer is completed, and cut off any excess parts on the membrane to increase the efficiency of the reagents.5. The optimal dilution amount for primary antibody and antibody reaction solution HRP (mouse) needs to be determined through preliminary experiments.6. The antibody reaction solution HRP (mouse), antibody dilution solution, and antibody dosage can be increased or decreased proportionally according to the size of the membrane.7. The antibody dilution solution containing the first antibody can be recycled and reused once. It is recommended not to reuse antibodies with poor specificity and affinity. If the recovered antibody is used within 1-2 days and stored at 2-8 ℃ for long-term storage, please freeze it at -20 ℃ to avoid repeated freeze-thaw cycles.8. If there is a high background, please adjust the amount of antibodies and increase the number of times the film is washed.9. All reagents in the reagent kit should be stored at 2-8 ℃ to avoid freezing and thawing.Operation steps:This product is suitable for the sealing and antibody incubation steps after membrane transfer, taking a 5 cm x 8 cm membrane as an example:1. Preparation of rinsing solution: Dilute 10 ml of Wash Buffer (10 x) with distilled water to 100 ml, which is 1 x Wash Buffer. Set aside. Use 8-10 ml for each film wash.2. Sealing: After the membrane transfer is completed, immerse the membrane in 10 ml Blocking Buffer and seal at room temperature for 5 minutes.3. Rinse: Pour off the sealing solution, add 8-10 ml of 1 x Wash Buffer, and rinse at a high speed on a shaker for 1 minute.4. Prepare antibody incubation solution while washing the membrane: Take Antibody Pretreat Solution (HRP/Mouse) 100 µ Add mouse derived primary antibody 3-10 into the centrifuge tube µ g. Suck and beat the gun head until thoroughly mixed, and incubate at room temperature for 5 minutes. Add to 10 ml Dilution Buffer and mix well. Note: 1) The dosage of primary antibody can also be adjusted according to the dilution of the antibody. Taking the final dilution of antibodies at 1:1000 as an example, take 100 µ Add HRP (mouse) antibody reaction solution into the EP tube and add 10 µ Add the first antibody to 10 ml of antibody diluent, mix well, and incubate at room temperature for 5 minutes. 2) If the membrane area is small, the amount of antibodies, reaction solution, and diluent can be reduced proportionally.5. After completing step 3, pour out the rinsing solution and add the antibody incubation solution mixed with primary antibody, Antibody Pretreat Solution (HRP/Mouse), and Dilution Buffer to the membrane (ensuring that the incubation solution completely submerges the surface of the membrane). Incubate at room temperature on a shaker at around 60 rpm for 40 minutes.6. Discard (recover) the antibody incubation solution and rinse 3-5 times with the prepared 1 x Wash Buffer, each time for 3 minutes. 7. Conduct subsequent testing. It is recommended to use ECL or DAB methods for testing.Application examples:Example 1 Antigen is 293T cell lysateA: Normal WB control: beta actin mouse monoclonal antibody (CW0096) 5 µ Incubate at room temperature for 40 minutes, wash the film and dilute the secondary antibody sheep anti mouse HRP (CW0102) 1:10000. Incubate at room temperature for 40 minutes and expose ECL (CW0049).B: One step method WB: beta actin mouse monoclonal antibody (CW0096) 5 µ Incubate at room temperature for 40 minutes and expose ECL (CW0049).Example 2 Antigen is E. coli multi label protein lysateC: Normal WB control: GST mouse monoclonal antibody (CW0084) 2.5 µ Incubate at room temperature for 40 minutes, wash the film and dilute the secondary antibody sheep anti mouse HRP (CW0102) 1:10000. Incubate at room temperature for 40 minutes and expose ECL (CW0049).D: One step method WB: GST mouse monoclonal antibody (CW0084) was incubated at room temperature with 2.5ug for 40 minutes, and ECL (CW0049) was exposed... Read More | Format:2-ComponentEnzyme:Horseradish peroxidase | Products R669890Component50 TStorageR669890ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669890B10×Reaction Buffer1mL-20℃. Avoid freeze/thaw cycle.R669890CBuffer RL35 mLRTR669890DBuffer RW140 mLRTR669890EBuffer RW2 (concentrate)11 mLRTR669890FRNase-Free Water10 mLRTR669890GSpin Products R669890Component50 TStorageR669890ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669890B10×Reaction Buffer1mL-20℃. Avoid freeze/thaw cycle.R669890CBuffer RL35 mLRTR669890DBuffer RW140 mLRTR669890EBuffer RW2 (concentrate)11 mLRTR669890FRNase-Free Water10 mLRTR669890GSpin Columns FL with Collection Tubes50 setsRTR669890HSpin Columns RM with Collection Tubes50 setsRTR669890IRNase-Free Centrifuge Tubes (1.5 mL)100 EART ProductsThis kit adopts centrifugal adsorption columns with high efficiency and specificbinding of nucleic acids and unique buffer system, which can rapidly extract totalRNA from bacteria or cultured animal cells.The reaction can be completed in 30-40minutes, and the extracted total RNA is extremely pure and free of protein and othercontaminants, which is suitable for RT-PCR, Real-Time RT-PCR, microarray analysis,in vitro translation and other experiments. Self-contained reagents: Lysozyme, β-mercaptoethanol, anhydrous ethanol (freshlyopened or for RNA extraction). Pre-experiment Preparation and Important Notes 1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination. 2) RNase-free water should be used to prepare the solution. 3) Operators wear disposable masks and gloves, and change gloves diligently duringthe experiment. 2. Add β-mercaptoethanol to Buffer RL before use to reach a final concentrationof 1%, e.g., add 10 µl of β-mercaptoethanol to 1 ml of Buffer RL. Buffer RL withβ-mercaptoethanol can be stored at 4℃ for 1 month, if precipitation occurs, pleaseheat to dissolve and use.3. Anhydrous ethanol should be added to Buffer RW2 before first use according tothe instructions on the reagent bottle label. 4. All centrifugation steps are carried out at room temperature if not otherwisespecified, and all steps should be performed quickly. Procedure 1. Centrifuge at 12,000 rpm (~13,400 x g) at 4°C for 2 minutes to collect theorganisms (maximum volume of organisms should not exceed 1 x 109) and carefullyremove all supernatants. Note: Supernatants that leave residues can interfere with the subsequent digestionprocess. 2. Thoroughly resuspend the organisms with 100 µl of TE buffer containing Lysozymeand incubate at room temperature. The specific formulation and incubation time areas follows:/The final concentration of Lysozyme in TE bufferincubation timeG-germ400µg/ml3-5minG+germ3mg/ml5-10min 3. Add 350 µl of Buffer RL (check that β-mercaptoethanol has been added beforeuse), vortex and shake to mix (insoluble precipitate may appear in this step), addall of the solution and the precipitate to the filter columns (Spin Columns FL) thathave been loaded into the collection tubes, and centrifuge at 12,000 rpm for 2minutes. 4. Add 250 µl of anhydrous ethanol to the filtrate obtained in the previous stepand mix well (a precipitate may appear at this point). Transfer the resulting solution together with the precipitate to a Spin Columns RM packed in a collectiontube, centrifuge at 12,000 rpm for 1 min, discard the waste solution and put thecolumn back into the collection tube.5. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for1min, discard the waste liquid and put the adsorbent column back into the collectiontube.6. Preparation of DNase I mixture: Take 52µl of RNase-Free Water, add 8µl of 10×Reaction Buffer and 20µl of DNase I (1U/µl) to it, mix well, and make a finalvolume of 80µl of reaction solution.7. Add 80µl of DNase I mixture directly to the adsorption column and incubate at20-30°C for 15 minutes.8. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for1min, discard the waste liquid and put the adsorbent column back into the collectiontube.9. Add 500 µl of Buffer RW2 to the column (check that anhydrous ethanol is addedbefore use), centrifuge at 12,000 rpm for 1 min, and discard the waste solution.10. Repeat step 9.11. Place the adsorbent column back into the collection tube and centrifuge at 12,000rpm for 2 minutes. Note: The purpose of this step is to remove residual ethanol from the adsorptioncolumn; ethanol residue can interfere with subsequent enzymatic reactions (zymography, PCR, etc.).12. Load the adsorption column into a new RNase-Free collection tube, add 30-50 µl of RNase-Free Water to the middle of the adsorption membrane, leave it at roomtemperature for 1 minute, centrifuge at 12,000 rpm for 1 minute, collect the RNAsolution, and store the RNA at -70°C to prevent degradation. Note: 1) The volume of RNase-Free Water should not be less than 30 µl, too smallvolume affects the recovery rate. 2) If you want to increase the RNA yield, repeat step 12 with 30-50 µl of freshRNase-Free Water. If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 12 repeated... Read More | This reagent kit uses an adsorption column that can specifically bind to viral RNA and a unique buffer system, suitable for isolating viral RNA from cell-free body fluids such as serum, plasma, urine, cerebrospinal fluid, and cell culture supernatants. The viral RNA specifically binds to the siliconThis reagent kit uses an adsorption column that can specifically bind to viral RNA and a unique buffer system, suitable for isolating viral RNA from cell-free body fluids such as serum, plasma, urine, cerebrospinal fluid, and cell culture supernatants. The viral RNA specifically binds to the silicon substrate membrane, and pollutants flow through the membrane. Completely remove impurities such as proteins through two efficient washes, and then wash high-purity viral RNA with RNase free water or RNase Free Water provided by the reagent kit. The virus RNA extracted by this kit can be directly used for experiments such as RT-PCR, Real time RT-PCR, and Western blot analysis. R666005Component50 TStorageR666005ABuffer GL15 mLRTR666005BBuffer RW140 mLRTR666005CBuffer RW2(concentrate)11 mLRTR666005DProteinase K12.5 mgRTR666005EProteinase K Storage Buffer1.25 mLRTR666005FRNase-Free Water10 mLRTR666005GSpin Columns RS with Collection Tubes50 setsRTR666005HRNase-Free Centrifuge Tubes(1.5 mL)50 EART Self prepared reagent: anhydrous ethanol, 0.9% NaCl.Preparation and important precautions before the experiment1. Add 1.25 ml of Protein K Storage Buffer to Protein K to dissolve it and store at -20 ℃. The prepared Protein K should not be left at room temperature for a long time to avoid repeated freeze-thaw cycles, which may affect its activity.2. To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.3. Serum or plasma should avoid repeated freeze-thaw cycles that may cause protein denaturation or precipitation, reduce viral titers, and thus affect the yield of extracted viral nucleic acids.4. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. If buffer GL precipitates, it can be heated at 56 ℃ to dissolve and then placed at room temperature.6. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps1. Take 200 at room temperature µ Add serum or plasma to a 1.5 ml centrifuge tube (self provided). Attention: Less than 200 µ 0.9% NaCl (provided by the customer) can be added to make up for it.2. Add 20 to the solution in the previous step µ Protein K, mix well.3. Add 200 µ L Buffer GL, vortex oscillation for 15 seconds. Note: Do not directly add Protein K to Buffer GL. 4. Incubate at 56 ℃ for 15 minutes, briefly centrifuge, and collect the solution on the tube wall to the bottom of the tube.5. Add 250 µ Anhydrous ethanol, vortex for 15 seconds, incubate at room temperature for 5 minutes, briefly centrifuge, and collect the solution from the tube wall to the bottom of the tube.6. Add all the solution obtained in step 5 to the Spin Columns RS that have been loaded into the collection tube. If it is not possible to add all the solution to the adsorption column at once, please transfer it in two batches, centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.8. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.9. Add 500 to the adsorption column µ Centrifuge anhydrous ethanol at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube. 10. Centrifuge at 12000 rpm for 3 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Attention:1) The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).2) Recommended steps: Place the adsorption column into a new 1.5 ml centrifuge tube (provided), open the tube cover, and incubate in a 56 ℃ oven for 3 minutes to thoroughly dry the membrane of the adsorption column.11. Place the adsorption column in a new RNase free centrifuge tube and add 20-50 to the middle of the adsorption column in the air µ Place RNase Free Water at room temperature for 5 minutes, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 20 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 20-50 µ Repeat step 11 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 11... Read More | Product contentY666144Component50 TStorageY666144ABuffer P115 mLRTY666144BBuffer P215 mLRTY666144CBuffer N320 mLRTY666144DBuffer PS15 mLRTY666144EBuffer PB10 mLRTY666144FBuffer PW (concentrate)10 mLRTY666144GBuffer EB10 mLRTY666144HGlass Beads2 gRTY666144IRNase A (10mg/mL)150 µLRTY666144JSpin Product contentY666144Component50 TStorageY666144ABuffer P115 mLRTY666144BBuffer P215 mLRTY666144CBuffer N320 mLRTY666144DBuffer PS15 mLRTY666144EBuffer PB10 mLRTY666144FBuffer PW (concentrate)10 mLRTY666144GBuffer EB10 mLRTY666144HGlass Beads2 gRTY666144IRNase A (10mg/mL)150 µLRTY666144JSpin Columns DM with Collection Tubes50 setsRTProductsThis kit is improved on the basis of common alkaline lysis method, the glass beads can effectively break the yeast cell wall, the new silica matrix membrane and buffer system can efficiently and specifically bind the plasmid DNA, and at the same time can maximize the removal of proteins and other impurities, the whole process is convenient and fast, no need to use toxic and harmful reagents, and can be processed at the same time for multiple samples. In addition to yeast cells, it can also be used in E. coli. Plasmid DNA extracted with this kit can be used in various molecular biology experiments, such as ligation, transformation, sequencing and library screening.Self-contained reagents: β-mercaptoethanol, anhydrous ethanol.Pre-experiment Preparation and Important Notes1. All components can be stably stored in dry, room temperature (15-30℃) environment for 1 year, the adsorption column can be stored at 2-8℃ for a longer period of time, and Buffer P1 with RNase A can be stably stored at 2-8℃ for 6 months.2. Before the first use, add all the RNase A solution to Buffer P1, mix well, and store at 2-8℃.3. Anhydrous ethanol should be added to Buffer PW before first use according to the instructions on the reagent bottle label.4. Before use, please check whether Buffer P2 and Buffer N3 are crystallized or precipitated. If there is any crystallization or precipitation phenomenon, it can be clarified by taking a water bath at 37℃ for a few minutes to restore the clarity.5. Be careful not to touch Buffer P2 and Buffer N3 directly, and tighten the lid immediately after use.6. The amount of plasmid extracted is related to the yeast strain, plasmid copy number, culture conditions, etc. Usually, yeast plasmid copy number is very low, which is difficult to be detected by electrophoresis or spectrophotometer method.Procedure1. Take 1-5 ml of yeast culture (maximum 5×107 yeast cells, generally for Saccharomyces cerevisiae OD = 1.0, equivalent to 1-2×107 cells/ml) and add it to a centrifuge tube (self-provided), centrifuge for 30 seconds at 12,000 rpm (~13,400×g), collect the bacterial precipitate, and aspirate as much as possible to discard the supernatant.2. Add 250µl Buffer P1 to the bacterium (please check if RNase A has been added first) and resuspend the precipitate.3. Add 40mg of Glass Beads to the above mixture and vortex and shake for 10 minutes.4. Add 250 µl of Buffer P2 to the centrifuge tube, mix gently by turning up and down 6-8 times, and let stand at room temperature for 5-10 minutes, at which time the bacterial solution should become clear and viscous.Note: Mix gently, do not shake violently, so as not to interrupt the genomic DNA, resulting in genomic DNA fragments mixed in the extracted plasmid. If the solution does not become clear, it suggests that the amount of bacteria may be too large and the lysis is not complete, and the amount of bacteria should be reduced.5. Add 350 µl of Buffer N3 to the centrifuge tube and immediately mix gently up and down 6-8 times, at which point a white flocculent precipitate appears, and centrifuge at 12,000 rpm for 20 minutes.Note: Buffer N3 should be mixed immediately after addition to avoid localized precipitation.6. Column Equilibration: Add 200 µl of Buffer PS to the Spin Columns DM in the collection tube, centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and place the column back into the collection tube.7. Add the supernatant from step 5 to the adsorbent column that has been loaded into the collection tube, taking care not to aspirate the precipitate.Note: The maximum volume of the adsorption column is 750 µl, and the solution is passed through the column in 2 times.8. Centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube and place the adsorption column back into the collection tube.9. Add 150 µl Buffer PB to the adsorbent column, centrifuge at 12,000 rpm for 1 min, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.10. Add 750 µl Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first), centrifuge at 12,000 rpm for 1 minute, and pour off the waste liquid in the collection tube.11. Place the column back into the recovery collection tube and centrifuge at 12,000 rpm for 2 minutes, pouring off the waste liquid. Leave the column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).12. Place the adsorbent column in a new centrifuge tube, add 50-100 µl of Buffer EB to the center of the adsorbent membrane dropwise, let it stand at room temperature for a few minutes, centrifuge at 13,000 rpm for 1 minute, and collect the plasmid solution into the centrifuge tube. Store the plasmid at -20°C.Attention:1) To increase the recovery efficiency of the plasmid, the resulting solution can be reintroduced into the adsorbent column, left at room temperature for a few minutes, centrifuged at 13,000 rpm for 1 minute, and the plasmid solution collected into a centrifuge tube.2) When the plasmid copy number is low or >10 kb, Buffer EB is preheated at 65-70°C in a water bath, which can increase the extraction efficiency.3) Usually yeast plasmids have very low copy number and are difficult to detect by electrophoresis or spectrophotometry. If the extracted plasmid is to be used in the next step of the experiment, it is usually recommended to use 1-5µl of the plasmid as PCR template, and 5-10µl of the plasmid for transformation of E. coli.4) Commercial high transformation efficiency receptor cells should be used for transformation of E. coli... Read More |