| Description | Product contentcomponent50T200TBuffer LP125mL100mLBuffer LP210mL40mLBuffer LP3 (concentrate)21ml84mlBuffer GW2 (concentrate)15mL75mlBuffer GE15mL60mLRNase A(10 mg/ml)300µl1.25mLSpin Columns DM with Collection Tubes50200ProductsThis kit uses centrifugal adsorption columns with highProduct contentcomponent50T200TBuffer LP125mL100mLBuffer LP210mL40mLBuffer LP3 (concentrate)21ml84mlBuffer GW2 (concentrate)15mL75mlBuffer GE15mL60mLRNase A(10 mg/ml)300µl1.25mLSpin Columns DM with Collection Tubes50200ProductsThis kit uses centrifugal adsorption columns with high efficiency and specific binding of nucleic acids and a unique buffer system, which is suitable for extracting genomic DNA from a wide variety of different fresh or frozen plant tissues with maximum removal of impurities from the plant tissues. The kit eliminates the need for phenol/chloroform extraction and is safe to handle. The extracted genomic DNA fragments are large, high purity, stable and reliable quality, suitable for PCR, fluorescence quantitative PCR, molecular labeling, library construction and other experiments.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller fragments of extracted DNA and a decrease in the amount extracted.2. Anhydrous ethanol should be added to Buffer LP3 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use. Check Buffer LP1 and Buffer LP2 for crystallization or precipitation before use. If crystallization or precipitation occurs, re-dissolve Buffer LP1 and Buffer LP2 in a 56°C water bath. Procedure1. Take about 100mg of fresh plant tissue or about 20mg of dry weight tissue and add liquid nitrogen to grind it fully.2. Collect the ground powder into a centrifuge tube (self-provided), add 400 µl Buffer LP1 and 6 µl RNase A (10 mg/ml), vortex and oscillate for 1 minute, and leave it at room temperature for 10 minutes to allow for full cleavage.Note: 1) Use vortex shaking or pipette blowing to fully lyses the tissue, incomplete tissue lysis will affect the final DNA yield. 2) Do not mix Buffer LP1 with RNase A prior to use.3. Add 130 µl Buffer LP2, mix well and vortex for 1 minute.4. Centrifuge at 12,000 rpm (~13,400 x g) for 5 minutes and transfer the supernatant to a new centrifuge tube (supplied).5. Add 1.5 times the volume of Buffer LP3 (check that anhydrous ethanol has been added before use) and mix thoroughly (e.g., 500 µl filtrate to 750 µl Buffer LP3).Note: Buffer LP3 should be mixed immediately after addition; precipitation may occur but will not affect subsequent experiments.6. Add all of the solution and precipitate obtained in the previous step to the adsorption columns (Spin Columns DM) that have been loaded into the collection tubes, if the solution cannot be added all at once, it can be transferred in several times. centrifuge the columns at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tubes, and put the columns back into the collection tubes.7. Add 500 µl of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: If the adsorbent membrane appears green, add 500 µl of anhydrous ethanol to the adsorbent column, centrifuge the column at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.8. Repeat step 7.9. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).10. Place the adsorption column in a new centrifuge tube (supplied), add 50-100 µl of Buffer GE or sterilized water dropwise to the middle of the adsorbent membrane, leave it at room temperature for 2-5 minutes, and centrifuge it at 12,000 rpm for 1 minute to collect the DNA solution. -The DNA solution was collected by centrifugation at 12,000 rpm for 1 min.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH value of the eluent has a great influence on the elution efficiency, if you use water as the eluent, you should ensure that the pH value is 7.0-8.5 (you can use NaOH to adjust the pH value of the water to this range), and when the pH value is lower than 7.0, the elution efficiency is not high.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.(3) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 10 can be re-added to the adsorbent membrane and repeat step 10; if the elution volume is less than 100µl, the final concentration of DNA can be increased, but it may reduce the total DNA yield. If the amount of DNA obtained is less than 1µg, 50µl Buffer GE is recommended for elution.4) Because DNA stored in water is subject to acidic hydrolysis, for long-term storage, elution with Buffer GE and storage at -20°C are recommended... Read More | Inquire | Product Content D669986Component50 TStorageD669986ABuffer SA15 mLRTD669986B2×PCR MasterMix1 mL-20℃. Avoid freeze/thaw cycle.D669986CProteinase K12.5 mgRTD669986DProteinase K Storage Buffer1.25 mLRTProductsThis kit adopts a unique buffer system containing all the reagents for rapid Product Content D669986Component50 TStorageD669986ABuffer SA15 mLRTD669986B2×PCR MasterMix1 mL-20℃. Avoid freeze/thaw cycle.D669986CProteinase K12.5 mgRTD669986DProteinase K Storage Buffer1.25 mLRTProductsThis kit adopts a unique buffer system containing all the reagents for rapid preparation of genomic DNA and PCR amplification, and is suitable for one-step extraction of genomic DNA from various plant and animal tissues and bacteria and for PCR amplification. The whole extraction process does not require liquid nitrogen grinding, organic solvent extraction, anhydrous ethanol precipitation, and the quality of extracted DNA is stable. The 2×PCR MasterMix provided in this kit is a highly compatible PCR reagent that can amplify DNA samples efficiently and specifically, which includes DNA polymerase, dNTPs, MgCl2, reaction buffer, PCR reaction enhancer and so on. It is characterized by fast and easy, high sensitivity, high specificity, good stability, etc. It is especially suitable for high throughput screening.Pre-experiment Preparation and Important Notes1. Add the specified amount of Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity.2. Repeated freezing and thawing of the samples should be avoided, as this will result in smaller DNA fragments and a decrease in the amount of extracted DNA.3. Before use, please check Buffer SA for crystallization or precipitation. If crystallization or precipitation occurs, please re-dissolve Buffer SA in a 56℃ water bath.4. The PCR MasterMix provided with this product is 2×, when using it, you need to add template and primer, and add RNase-Free Water to make up the volume, so that its concentration is 1× to carry out the reaction.Procedure1. Fetch:Plant material: take about 10 mg of sample in a centrifuge tube (provided); Animal material: take about 10 mg of sample in a centrifuge tube (provided);Bacteria: Take 200-800 µL of bacteria in good growth condition in a centrifuge tube (self-provided) and collect the bacteria.2. Add 200 µL of Buffer SA and vortex to mix.Note: In the case of plant leaves and animal tissues, they should be ground with a pestle and mortar as much as possible: in the case of plant seeds, they should be crushed and finely ground beforehand; bacterial and 1-3 mm rat-tail samples can be directly vortex lysed.3. Add 10µL of Proteinase K, mix well, incubate at 56℃ for 10 minutes, and treat at 95℃ for 5 minutes.Note: 1) In the case of animal tissue samples, the incubation time at 56°C may be extended to 30 minutes as appropriate; if there is any incompletely digested tissue, it should be removed as thoroughly as possible after centrifugation in the next step.2) Be careful not to exceed 5 minutes when treating at 95°C.4. 13,000 rpm (~17,900 x g), centrifugation for 5 minutes.5. Transfer the supernatant to a new centrifuge tube (self-prepared) and use it directly for PCR amplification, or store the solution at 4℃ or -20℃.6. PCR amplification:1) PCR reaction system:The following examples are conventional PCR reaction systems and reaction conditions, which should be improved and optimized according to the template, primer structure and target fragment size in actual operation.reagents20 µL systemfinal concentration2×PCR MasterMix10 µL1×Forward Primer, 10 µM1 µL0.4 µMReverse Primer, 10 µM1 µL0.4 µMTemplate DNA1-2 µL RNase-free Waterup to 20 µLNote: Please use the final concentration of 0.2-0.6µM as a reference for setting the range of primer concentration. If the amplification efficiency is not high, the concentration of primer can be increased; if a non-specific reaction occurs, the concentration of primer can be decreased, thus optimizing the reaction system.2)PCR reaction conditions:movetemptimingpremutability94°C2mindenaturation94°C30sannealing (metallurgy)55-65°C30s30-40 cyclesreach72°C60sultimate extension72°C5minNote: 1) In general, the annealing temperature is 5℃ lower than the melting temperature of the amplification primer Tm, and the annealing time is generally 30-60 seconds. When the desired amplification efficiency cannot be obtained, the annealing temperature should be lowered appropriately; when a non-specific reaction occurs, the annealing temperature should be raised, thus optimizing the reaction conditions.(2) The extension time is set according to the size of the fragment to be amplified, and the amplification efficiency of Taq DNA Polymerase included in this product is 1kb/30s. 3) The number of cycles can be set according to the downstream application of the amplification product. If the number of cycles is too low, the amplification is insufficient; if the number of cycles is high, the chance of mismatch will increase and the non-specific background will be serious. Therefore, the number of cycles should be minimized under the premise of ensuring the product yield.(3) Result detection: 5 µL of reaction product was taken at the end of the reaction and directly detected by agarose gel electrophoresis... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Inquire |