| Description | Product contentS665868Component50 TStorageS665868ABuffer GL25 mLRTS665868BBuffer GW1 (concentrate)13 mLRTS665868CBuffer GW2 (concentrate)15 mLRTS665868DBuffer GE15 mLRTS665868EProteinase K2×1.25 mLRTS665868FSpin Columns DM with Collection Tubes50 setsRTProduct IntroductionThis kit is suitable Product contentS665868Component50 TStorageS665868ABuffer GL25 mLRTS665868BBuffer GW1 (concentrate)13 mLRTS665868CBuffer GW2 (concentrate)15 mLRTS665868DBuffer GE15 mLRTS665868EProteinase K2×1.25 mLRTS665868FSpin Columns DM with Collection Tubes50 setsRTProduct IntroductionThis kit is suitable for the extraction of genomic DNA from fresh saliva or saliva/preservation solution mixture.The purification process of this product does not require the use of toxic solvents such as phenol or chloroform, and ethanol precipitation is not necessary. The optimized buffer system enables DNA to bind heterogeneously to the silica matrix centrifugal adsorption column, and the inhibitors of PCR and other enzymatic reactions can be effectively removed by a two-step washing step, and finally eluted with a low-salt buffer or water to obtain high-purity DNA.The purified obtained can be directly used for enzyme digestion, PCR, Real-Time PCR, library construction, Southern Blot, molecular labeling and other downstream experiments.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller fragments of extracted DNA and a decrease in the amount extracted.2. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.3. Before use, please check whether Buffer GL appears to be crystallized or precipitated.Redissolve in a 56°C water bath.4. If the downstream experiments are sensitive to RNA contamination, 4 µL DNase-Free RNase A can be added in step 3(100 mg/mL).5. For prolonged storage of salivary DNA at room temperature, our Salivary DNA Preservation Tubes are recommended.Operation steps1. Add 400 µL of saliva sample or saliva/preservation solution mixture.Note: 1) Saliva mixtures added to the preservation solution require a 50°C water bath for 1 hour or an empty 50°C temperature chamber for 2 hours prior to extraction.2) If an increase in sample volume is required, multiply the volumes of Proteinase K, Buffer GL, and anhydrous ethanol in Steps 2-4, and the liquid can be transferred in multiple times in Step 5.2. Add 40 µL of Proteinase K.3. Add 400µL Buffer GL, vortex and shake to mix thoroughly, and water bath at 56℃ for 15-30 minutes.Note: If RNA removal is required, add 4 µL of RNase A solution at a concentration of 100 mg/mL after the above steps are completed, vortex for 15 seconds, and leave at room temperature for 2 minutes.4. Centrifuge briefly to remove water droplets from the inside of the tube cap. Add 400 µL of anhydrous ethanol and mix well by vortexing and shaking. Centrifuge briefly.Note: 1) Vortex and shake to mix immediately after adding Buffer GL and anhydrous ethanol.The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.2) A sol-gel product may be formed after GL and anhydrous ethanol, in which case vigorous shaking or vortexing is recommended.3) The solution obtained in the previous step is added to the adsorption column in the Collection Tube.5. (Spin Column DM) in the collection tube, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge at 12,000 rpm (∼13,400 × g) for 1 min, pour off the waste solution in the collection tube, and put the adsorption column back into the collection tube.6. Add 500 µL of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new centrifuge tube (supplied), add 50-200 µL of Buffer GE or sterilized water to the middle of the adsorption column overhanging the column, let it stand at room temperature for 2-5 minutes, and centrifuge at 12,000 rpm for 1 minute to collect the DNA solution.-20°C to preserve DNA.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH is 7.0-8.5 (you can use NaOH to adjust the pH of the water to this range), and the elution efficiency is not high when the pH is lower than 7.0.2) Buffer GE preheated in a 65-70°C water bath and incubated at room temperature for 5 min before centrifugation can increase the yield.3) Because DNA preserved in water is subject to acidic hydrolysis, for long-term storage, elution with Buffer GE and storage at -20°C is recommended... Read More | DescriptionCobalt is a transition metal that serves as a trace dietary mineral for all multicellular organisms. Cobalt is an important cofactor for the Vitamin B12class of compounds where it occupies the center of the vitamin B12corrin ring. Cobalt can also be coordinated in the active site of the DescriptionCobalt is a transition metal that serves as a trace dietary mineral for all multicellular organisms. Cobalt is an important cofactor for the Vitamin B12class of compounds where it occupies the center of the vitamin B12corrin ring. Cobalt can also be coordinated in the active site of the non-corrin containing metalloenzyme methionine aminopeptidase.Suitability: Suitable for quantitating cobalt concentrations in a variety of samplesPrinciple: The Cobalt Assay kit provides a simple and direct procedure for measuring cobalt in a variety of samples. In this assay, cobalt reacts with 2-mercaptoethanol under basic conditions to form a complex with a strong absorbance at 475 nm. Interference from the metal ions Fe2+, Cu2+, Ni2+, Zn2+, and Mn2+is <10% at this wavelength. This assay gives a linear range of 10-50 nmoles of cobalt.}Preparation instructionsSuitable for quantitating cobalt concentrations in a variety of samplesPrincipleThe Cobalt Assay kit provides a simple and direct procedure for measuring cobalt in a variety of samples. In this assay, cobalt reacts with 2-mercaptoethanol under basic conditions to form a complex with a strong absorbance at 475 nm. Interference... Read More | Product introduction:Dualucif The firefly & Renilla assay kit (dual luciferase reporter assay kit) provides an effective means to detect the expression of genes. In DLR detection, the activities of firefly luciferase and Renilla luciferase can be detected in a single sample in turn. FirstProduct introduction:Dualucif The firefly & Renilla assay kit (dual luciferase reporter assay kit) provides an effective means to detect the expression of genes. In DLR detection, the activities of firefly luciferase and Renilla luciferase can be detected in a single sample in turn. First, luciferin was used as substrate to detect the activity of firefly luciferase, then substances inhibiting the catalysis of firefly luciferase were added, and coelenterazine was added to detect the activity of Renilla luciferase to achieve dual luciferase reporter gene detection. The bioluminescence system of luciferase and its substrate can detect gene expression very sensitively and efficiently. Usually, the transcriptional regulatory element or 5'promoter region of the gene of interest is cloned upstream of luciferase, or the 3'-utr region is cloned downstream of luciferase to construct a reporter gene plasmid, and then transfect the cells. After the cells are treated with appropriate drugs, the cells are lysed, and the transcriptional regulation effect of drug treatment on the target gene is judged by detecting the luciferase activity. Renilla luciferase is more often used as an internal reference for detecting transfection efficiency to eliminate the difference in cell number and transfection efficiency. Firefly luciferase is a protein with a molecular weight of about 61 kDa. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. Renilla luciferase is a protein with a molecular weight of about 36 kDa. In the presence of oxygen, it can catalyze the oxidation of coelenteramide to coelenteramide, and also produce light signals in the process of coelenteramide oxidation. The optical signal of this kit can be measured by chemiluminescence instrument, microplate reader or liquid scintillation tester. The kit has the characteristics of rapid detection, high sensitivity, wide detection range and no interference of cell endogenous activity.Instruction:1.Cell lysis ( 1 ) Remove the medium and gently wash twice with PBS ( adherent cells can be operated directly, suspension cells need to be centrifuged to collect cells ). Add 1 × Lysis Buffer ( diluted component A with sterile water at 4 : 1 ) according to the following scheme, and then place the culture plate on a micro-oscillator at room temperature for 15 min to fully lyse the cells. Note : The pyrolysis products can be stored at room temperature for 6 h, and can be stored at − 70 °C for a long time ( the pyrolysis products cannot be repeatedly frozen and thawed ). ( 2 ) The pyrolysis products were centrifuged at 10000-15000 rpm for 3-5 min. After centrifugation, the supernatant was transferred into a new EP tube for subsequent detection. Note : Cells can be detected immediately after lysis, or frozen, and re-detected when needed. The frozen samples need to be thawed to room temperature for detection. 2. Preparation of working fluid ( 1 ) Restore all components to room temperature. ( 2 ) Dilute component C with component B to 0.2 mg / mL firefly luciferase working solution. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the amount of a single experiment is small, it is recommended to be subpackaged into small specifications according to a single amount of use. ( 3 ) The E component was diluted into the renilla luciferase working solution with the D component, and the dilution method was 1 µL E component was added to the 49 µL D component. Note : Renilla luciferase working solution needs to be prepared now. 3.chemiluminescence value detection ( 1 ) According to the operation instructions of the instrument, the instrument with chemiluminescence detection function was opened, such as multifunctional microplate reader. The parameters were set, the determination time was 10 s, and the determination interval was 2 s. ( 2 ) each sample determination, take the sample 20-100 µL ( if the sample volume is enough, please add 100 µL ; if the sample amount is insufficient, the amount can be appropriately reduced, but the amount of detection holes needs to be consistent ). 1 × Lysis Buffer was blank control. ( 3 ) 100 µL firefly luciferase working solution was added to determine the RLU ( relative light unit ) value ( it is recommended that the microplate reader set up the Shaking mixing function ). Note : Since the luminescence is instantaneous, it is recommended to detect immediately after adding the firefly luciferase working solution. ( 4 ) 100 µL renilla luciferase working solution was added to determine the RLU ( relative light unit ) value ( Shaking mixing function is recommended for microplate reader ). ( 5 ) In the case of renilla luciferase as an internal reference, the RLU value measured by firefly luciferase was divided by the RLU value measured by renilla luciferase. According to the obtained ratio, the activation degree of the target reporter gene between different samples was compared. If firefly luciferase is used as an internal reference, similar calculations can also be performed.Component:Recommendation:It is recommended to use component B in advance to prepare 2 mg / mL storage solution, component B, component D and component C prepared as storage solution, and to carry out small batch packing according to the experimental requirements. All test working fluids are recommended to be used now to avoid repeated freezing and thawing.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. in order to obtain the best determination effect, when using a single tube chemiluminescence instrument for determination, the time from the mixing of sample and determination reagent to the pre determination should be controlled as much as possible; When using a multi-functional fluorescent microplate reader with chemiluminescence detection function, it is advisable to add all samples first, and then uniformly add firefly luciferase detection reagent. 3. the strongest wavelength of firefly luciferase catalyzed bioluminescence is 560 nm, and the strongest wavelength of Renilla luciferase catalyzed bioluminescence is 480 nm. 4. to prevent interference between holes, it is recommended to use white opaque orifice plate. 5. due to the influence of temperature on enzyme reaction, the sample and reagent should be measured after reaching room temperature. 6. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Study on gene expression regulation and promoter... Read More | Inquire | Vitamins Kit is a multivitamin mix comprising biotin, folic acid, vitamin B6, riboflavin, thiamine, D-pantothenic acid and niacinamide.Vitamins Kit has been used as a vitamin supplement in the minimal medium for conidia spores and vegetative cultures |