| Description | DescriptionIt contains a set of six different heterogeneous palladium catalysts, useful for rapid screening of catalysis conditions. It is in sampler format with individual components packaged for multiple experiments and mini scale-up. The cost of the kit is less than the total cost of individual DescriptionIt contains a set of six different heterogeneous palladium catalysts, useful for rapid screening of catalysis conditions. It is in sampler format with individual components packaged for multiple experiments and mini scale-up. The cost of the kit is less than the total cost of individual components.Catalysis Screening Kits... Read More | Product introduction:Product introduction:Cell Cycle Assay Kit Plus ( Cell Cycle Assay Kit Plus ) has certain applicability for live cells and fixed cell cycle detection. For different types of cells, whether it is applicable or not needs to be determined after testing. Cell Cycle Product introduction:Product introduction:Cell Cycle Assay Kit Plus ( Cell Cycle Assay Kit Plus ) has certain applicability for live cells and fixed cell cycle detection. For different types of cells, whether it is applicable or not needs to be determined after testing. Cell Cycle Assay Kit Plus ( Cell Cycle Assay Kit Plus ) uses RedNucleus I staining to detect cell cycle. RedNucleus I is a far-infrared nucleic acid dye with cell membrane permeability, which can quickly enter living cells, specifically bind to DNA, and perform cell cycle detection on living cells without RNase digestion. Compared with the traditional PI staining method, the cells do not need to be broken or fixed, and the operation is simpler. RedNucleus I is a fluorescent dye of double-stranded DNA, and the fluorescence intensity after binding to double-stranded DNA is proportional to the content of double-stranded DNA. The intracellular DNA content can be measured by flow cytometry, and then the cell cycle analysis can be carried out according to the distribution of DNA content. After RedNucleus I staining, assuming that the fluorescence intensity of G0 / G1 phase cells is 1, the theoretical value of the fluorescence intensity of G2 / M phase cells containing two copies of genomic DNA is 2, and the fluorescence intensity of S phase cells undergoing DNA replication is between 1-2. In addition, RedNucleus I is compatible with dyes such as Horizon BV / BUV, FITC and R-PE, and can be periodically detected after sample staining.The kit is usually used to detect the cell cycle of cultured adherent or suspended cells. If it is used for cell cycle detection of tissues, the tissues must be digested into a single cell state.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. this product is applicable to the detection of living cells and fixed cell cycle with certain limitations. Whether it is applicable to different types of cells needs to be determined after testing. If fixation is needed, it is recommended to use ice bath pre cooling 75-80% ethanol -20 ℃ to fix cells overnight. 3. fluorescent dyes have quenching problems. Please try to avoid light during storage and use to slow down fluorescence quenching. 4. for your safety and health, please wear experimental clothes and disposable gloves.Instruction: Experimental materials ( self-provided ):①cell lines or other cell samples ( self-prepared ) ;②This kit ; ③ trypsin ( self-prepared ) ;④ Cell culture medium containing FBS ( self-prepared ) ; Experimental procedure: 1.Preparation of cell samples : ( 1 ) ( This step is for adherent cells, if suspended cells, can be carried out directly step ( 2 ) ) Digest cells with trypsin, add cell culture medium, gently blow away cells, collected into the centrifuge tube. Note : The number of cells on the machine needs to reach 50,000 and above, so the initial number of cells collected needs to be sufficient. ( 2 ) Centrifuged about 1000 g for 3-5 min to precipitate cells. Carefully remove the supernatant, add about 1 mL of ice bath pre-cooled 1 × staining buffer ( 10 × staining buffer diluted with diH2O at 1 : 10 ), re-suspend the cells. Repeat once. ( 3 ) Centrifuged about 1000 g for 3-5 min to precipitate cells. After the supernatant was discarded, 1 mL of culture medium was added to re-suspend the cells ( for fixed cells, 1 × PBS can also be used to re-suspend ). Gently flick the bottom of the centrifuge tube to properly disperse the cells to avoid cell aggregation. 2.Staining : 4 µL of RedNucleus I staining solution was added to each tube of cell samples, slowly and fully mixed, and incubated at room temperature in dark for 20 min ( or incubated at 37 ° C in dark for 5-10 min ). The optimal incubation time of different cells is different, and the staining time can be adjusted and optimized according to the actual staining effect to obtain a more ideal staining effect. 3.Flow cytometry detection and analysis : Excited at 638 nm by flow cytometry, it is recommended to detect in RL3 or FL4 channels, or use RL1 and RL2 channels. Cell DNA content analysis and light scattering analysis were performed using appropriate analysis software.Scope of application:Cell cycle detection... Read More | DescriptionWhite LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatableDescriptionWhite LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatable milliamp selection for photon intensity (sold seperately)0-30 mA variable LED outputNon-magnetic LED baseChemically resistant LED coverPTFE coated cablingPhoto Kitalysis Starter Kitrequired for operation (sold separately). Best when used withKitAlysis Benchtop Inertion Box(sold separately)... Read More | R669988 Component 50T Storage R669988A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. R669988B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. R669988C Buffer RL 35 mL RT R669988D Buffer RLC 35 mL RT R669988E Buffer RW1 40 mL RT R669988F Buffer RW2 (concentrate) 11 mL R669988 Component 50T Storage R669988A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. R669988B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. R669988C Buffer RL 35 mL RT R669988D Buffer RLC 35 mL RT R669988E Buffer RW1 40 mL RT R669988F Buffer RW2 (concentrate) 11 mL RT R669988G RNase-Free Water 10 mL RT R669988H Spin Columns FL with Collection Tubes 50 sets RT R669988I Spin Columns RM with Collection Tubes 50 sets RT R669988J RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTProductsThis kit is used for the extraction and purification of high-quality total RNA from a variety of plants, and is also suitable for the extraction of fungal mycelial RNA. The unique separation column is used for homogenization and filtration of high viscosity plant or fungal lysates, while the silicon matrix membrane is used to adsorb the RNA for purification, so that various contaminants, such as polysaccharides, are effectively removed by washing, and the eluted RNA can be directly used in various downstream experiments. The molecular weight of RNA extracted by this kit is more than 200 bases, with high purity and almost no DNA residue. For RNA experiments that are very sensitive to trace DNA, the residual DNA can be removed by digestion on a column using RNase-free DNase. The extracted RNA can be used in Northern Blot, Dot Blot, RT-PCR and in vitro translation experiments.Self-contained reagents: β-mercaptoethanol, anhydrous ethanol (freshly opened or for RNA extraction).Pre-experiment Preparation and Important Notes1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.2) RNase-free water should be used to prepare the solution.(3) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.2. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.(2) Glassware should be dry-roasted at 180°C for 4 hours before use, and plasticware can be soaked in 0.5M NaOH for 10 minutes, rinsed thoroughly with water and autoclaved.3) RNase-free water should be used to prepare the solution.(4) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.3. Avoid repeated freezing and thawing of the extracted samples, otherwise it will affect the amount and quality of RNA extraction.4. Please add β-mercaptoethanol to Buffer RL before use, add 10µl of β-mercaptoethanol to 1ml of Buffer RL, it can be stored for 1 month at room temperature. Buffer RL with β-mercaptoethanol can be stored at room temperature for 1 month. β-mercaptoethanol is not required for use of Buffer RLC.5. Anhydrous ethanol should be added to Buffer RW2 before first use according to the instructions on the reagent bottle label.6. If precipitation occurs in Buffer RL and Buffer RLC, heat to dissolve and leave at room temperature.7. All centrifugation steps are carried out at room temperature and all steps are performed quickly. Procedure1. 50-100 mg of plant tissue is quickly ground to a powder in liquid nitrogen and added to 600 µl of Buffer RL (check for addition of β-mercaptoethanol before use) or Buffer RLC. vortexing and oscillating to allow for adequate lysis.Note: 1) The main component of Buffer RL is guanidine isothiocyanate, which is suitable for lysis of most plant tissues. However, in some plant tissues (e.g. endosperm of corn), due to the special secondary metabolites, guanidine isothiocyanate causes precipitation of the sample, resulting in poor RNA extraction, in this case, Buffer RLC can be added instead of Buffer RL.2) Incubation at 56°C for 1-3 minutes helps tissue lysis, but do not incubate at high temperatures for plants with high starch content.2. Transfer all the liquid obtained in step 1 to an adsorption column (Spin Columns FL) that has been loaded into a collection tube, centrifuge at 12,000 rpm (~13,400 x g) for 2 minutes, and transfer the supernatant from the collection tube to a new centrifuge tube (supplied).Note: 1) The tip of the tip of the gun can be cut off when aspirating liquids to facilitate sampling.2) Spin Columns FL removes most of the debris, but a small portion will still flow out and a precipitate will form in the collection tube after centrifugation, so be careful to avoid aspirating the precipitate when proceeding to the next step.3. Add 0.5 times the volume of anhydrous ethanol to the clean lysate obtained in step 2 and mix rapidly.Note: Precipitation may occur upon addition of ethanol, but does not affect subsequent tests.4. Transfer the solution obtained in the previous step to the Spin Columns RM in the collection tube. If it is not possible to add all of the solution to the column at one time, centrifuge the column at 12,000 rpm for 15 seconds in two batches, discard the waste solution and put the column back into the collection tube.5. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, discard the waste liquid and put the adsorbent column back into the collection tube.6. Preparation of DNase I mixture: Take 52µl of RNase-Free Water, add 8µl of 10×Reaction Buffer and 20µl of DNase I (1U/µl) to it, mix well, and make a final volume of 80µl of reaction solution.7. Add 80µl of DNase I mixture directly to the adsorption column and incubate at 20-30°C for 15 minutes.8. Add 350 µl of Buffer RW1 to the adsorption column, centrifuge at 12,000 rpm for 1 minute, discard the waste liquid and put the column back into the collection tube.9. Add 500 µl of Buffer RW2 to the column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 15 seconds, and discard the waste solution.10. Repeat step 9.11. Place the adsorbent column back into the collection tube, centrifuge at 12,000 rpm for 1 minute, and allow the column to come to room temperature for a few minutes to thoroughly dry out the anhydrous ethanol in the adsorbent column.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (zymography, PCR, etc.).12. Load the adsorption column into a new centrifuge tube, add 30-50 µl of RNase-Free Water to the middle of the adsorbent membrane, leave it at room temperature for 1 minute, centrifuge at 12,000 rpm for 1 minute, and store the resulting RNA solution at -70°C to prevent degradation.Note: 1) The volume of RNase-Free Water should not be less than 30 µl, too small volume affects the recovery rate.2) If you want to increase the RNA yield, repeat step 12 with 30-50 µl of fresh RNase-Free Water.3) If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 12 repeated... Read More | DescriptionTakasago (R)-Ru Cymene Kit I comprises of ruthenium-based biphenyl phosphine cymene catalysts containing either BINAP and SEGPHOS®ligands. These highly reactive and selective catalysts are useful in a variety of asymmetric reactions, mainly asymmetric hydrogenation |