| Description | Product content:E665636Component50 TStorageE665636ABuffer P115 mLRTE665636BBuffer P215 mLRTE665636CBuffer E315 mLRTE665636DBuffer PS15 mLRTE665636EBuffer PW (concentrate)10 mLRTE665636FEndo-Free Buffer EB10 mLRTE665636GRNase A (10 mg/mL)150 µLRTE665636HEndo-Remover FMwith Collection Tubes50 Product content:E665636Component50 TStorageE665636ABuffer P115 mLRTE665636BBuffer P215 mLRTE665636CBuffer E315 mLRTE665636DBuffer PS15 mLRTE665636EBuffer PW (concentrate)10 mLRTE665636FEndo-Free Buffer EB10 mLRTE665636GRNase A (10 mg/mL)150 µLRTE665636HEndo-Remover FMwith Collection Tubes50 EARTE665636ISpin Columns DMwith Collection Tubes50 EART Product Introduction:Endotoxins are a common pollutant in plasmid extraction. Due to the high sensitivity of eukaryotic cells to endotoxins, the presence of endotoxins in plasmids can greatly reduce the transfection efficiency of eukaryotic cells. This reagent kit provides a simple, fast, and efficient new method for extracting endotoxin free plasmids. The extracted plasmids remove endotoxins to the maximum extent possible and can effectively remove contamination of genomic DNA, RNA, proteins, etc. The operation is simple and convenient. This reagent kit is suitable for extracting 1-5mL of bacterial solution. On the basis of alkaline lysis of cells, it efficiently and specifically binds plasmid DNA through a new silicon-based membrane. Each adsorption column can adsorb up to 40% µ The plasmid DNA of g is effectively removed using a special buffer system and endotoxin removal filter column, effectively removing impurities such as endotoxins and proteins. The plasmid obtained from this kit has high purity and stable quality, making it particularly suitable for cell transfection. It can also be used for downstream experiments such as DNA sequencing, PCR, PCR based mutations, in vitro transcription, transformed bacteria, and endonuclease digestion.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1. All components can be stably stored for 1 year in a dry, room temperature (15-30 ℃) environment. The adsorption column can be stored for a longer time at 2-8 ℃. Buffer P1 with RNase A added can be stably stored for 6 months at 2-8 ℃. 2. Before the first use, add all RNase A solution to Buffer P1, mix well, and store at 2-8 ℃. Before use, let it sit at room temperature for a period of time. After returning to room temperature, use.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer P2 and Buffer E3. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. Be careful not to come into direct contact with Buffer P2 and Buffer E3, and immediately cover them tightly after use.6.The amount and purity of plasmid extraction are related to factors such as bacterial culture concentration, strain type, plasmid size, and plasmid copy number.Operation steps:1. Take 1-5 mL of overnight cultured bacterial solution and add it to a centrifuge tube (provided). Centrifuge at 13000 rpm (~16200 × g) for 30 seconds to collect bacteria, and try to discard all the supernatant as much as possible.2. Add 250 to the centrifuge tube containing bacterial sediment µ L Buffer P1 (please check if RNase A has been added first), mix thoroughly with a pipette or vortex oscillator, and suspend bacterial precipitation.Attention: If the bacterial blocks are not thoroughly mixed, it will affect the cracking effect, resulting in low extraction amount and purity.3. Add 250 to the centrifuge tube µ L Buffer P2, gently invert and mix 8-10 times, allowing the bacterial cells to fully lyse. Leave at room temperature for 3-5 minutes. At this point, the solution should become clear and viscous.Attention: Mix gently and do not shake vigorously to avoid interrupting genomic DNA and mixing genomic DNA fragments in the extracted plasmid. If the solution does not become clear, it indicates that the bacterial count may be too high and the lysis may not be complete. The bacterial count should be reduced.4. Add 250 to the centrifuge tube µ L Buffer E3, immediately invert and mix 8-10 times until white flocculent precipitates appear. Let it stand at room temperature for 5 minutes. Centrifuge at 13000 rpm for 5 minutes, extract the supernatant, and add it to a filter column (Endo Remove FM). Centrifuge at 13000 rpm for 1 minute to filter, and collect the filtrate in a centrifuge tube (self provided).Attention: After adding Buffer E3, it should be mixed evenly immediately to avoid local precipitation. 5. Add 225 to the filtrate µ Mix L isopropanol upside down.6. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ L Buffer PS, centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Transfer the mixed solution of filtrate and isopropanol from step 5 to an equilibrium adsorption column (already loaded into a collection tube).8.13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Attention: The maximum volume of the adsorption column is 750 µ L. If the sample volume is greater than 750 µ L can be added in batches. 9. Add 750 to the adsorption column µ L Buffer PW (please check if anhydrous ethanol has been added first), centrifuge at 13000 rpm for 1 minute, and discard the waste liquid in the collection tube.10. Place the adsorption column back into the recovery manifold and centrifuge at 13000 rpm for 1 minute. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new collection tube and add 50-100 to the middle of the adsorption membrane µ L Endo Free Buffer EB, let it stand at room temperature for 2-5 minutes, centrifuge at 13000 rpm for 2 minutes, and collect the plasmid solution into a centrifuge tube- Store the plasmid at 20 ℃.Note: 1) To increase the efficiency of plasmid recovery, the obtained solution can be added back to the adsorption column, left at room temperature for 2-5 minutes, centrifuged at 13000 rpm for 2 minutes, and collected into a centrifuge tube.2) When the plasmid copy number is low or>10 kb, preheating the Endo Free Buffer EB in a water bath at 65-70 ℃ can increase the extraction efficiency... Read More | Inquire | CFDASE cell proliferation and tracking detection kit is a kit for cell proliferation and tracking detection based on CFDA se. This kit is composed of CFDASE powder, solvent and staining buffer. CFDASE is a derivative of fluorescein diacetate (FDA), which has cell membrane permeability and CFDASE cell proliferation and tracking detection kit is a kit for cell proliferation and tracking detection based on CFDA se. This kit is composed of CFDASE powder, solvent and staining buffer. CFDASE is a derivative of fluorescein diacetate (FDA), which has cell membrane permeability and does not have fluorescence luminescence. When CFDASE penetrates the cell membrane into living cells, it can be catalysed by esterases in the cytosol to produce carboxyfluorescein succinimidyl ester (CFSE), which can emit strong green fluorescence, cannot penetrate the cell membrane, and can remain intact in the cell. CFSE can also spontaneously and irreversibly covalently bind to intracellular amino groups to couple to cellular proteins. Meanwhile, the excess and uncoupled CFDASE returned to the extracellular medium by passive diffusion and was cleared by subsequent washing steps. The fluorescence of non dividing cells labeled by CFDASE is very stable, and the stable labeling time can reach several months, so it is very suitable for cell community analysis. The fluorescence of CFDASE labeled cells is very homogeneous, which is superior to other cell tracking fluorescent probes used previously, such as PKH26, and the fluorescence distribution of the divided progeny cells is also very uniform. In the process of cell division and proliferation, CFSE labeled fluorescence can be evenly distributed to the two progeny cells, and the fluorescence intensity becomes half of the parental cells. According to the fluorescence intensity, flow cytometer (FL1 channel) can detect undivided cells, cells that divide once (1 / 2 of the fluorescence intensity), twice (1 / 4 of the fluorescence intensity), three times (1 / 8 of the fluorescence intensity), and cells that divide more times. CFDASE can detect up to eight or more cleavages. CFDASE labeled cells can be used for proliferation studies in vitro and in vivo, and have the function of not staining adjacent cells. CFDASE is most commonly used to detect the proliferation of lymphocytes, and can also be used to detect the proliferation of fibroblasts, NK cells and other cells. CFDASE labeled cells showed green fluorescence. In addition to flow cytometry to detect cell proliferation, fluorescence microscopy can also be used for homogeneous staining of cell tracking observation.Components:ComponentsC598182-20TC598182-500TA. CFDA SE1 tube1 tubex5B.CFDA SE solvent20 µL500 µLC.10x CFDA SE Buffer1 mL x250 mLMatters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. CFDA and Se are easily hydrolyzed and will deteriorate quickly in aqueous solution. Please avoid contact with water during use. Contact with water during the process of labeling cells is within the permitted range. 3. CFDA se solvent will solidify at lower temperatures such as 4 º C and ice bath and stick to the bottom, wall or cover of the centrifugal tube. It can be used after incubating in a 20-25 º C water bath for a while until it is completely dissolved. 4. this kit optimizes the CFDA se staining system, but users are advised to explore the optimal working concentration and staining time according to their own cell type, culture conditions and application direction. Different cells have different lactonase activities, so the staining effect is different. 5. fluorescent dyes have quenching problems. Please avoid light during operation to slow down fluorescence quenching. 6. for your safety and health, please wear experimental clothes and disposable gloves.Usage method:1. Preparation of reagents(1) Preparation of CFDA SE storage solution: Take one tube of CFDA SE provided in the reagent kit and restore it to room temperature. Instantly centrifuge to allow the powder to fully settle to the bottom of the tube. Add 100 µ L CFDA SE solvent (add 20 µ L CFDA SE solvent) to it and dissolve it thoroughly to prepare CFDA SE storage solution (1000 ×). Prepared CFDA SE storage solution, stored at -20 ℃ in the dark, with a shelf life of two months- Storing at 70 ℃ in the dark can extend the usage time appropriately.(2) Preparation of CFDA SE Buffer: Dilute 10 x CFDA SE Buffer to 1 x with sterile cell culture grade water as needed. The prepared 1 × CFDA SE Buffer can be stored at 4 ℃ and can be stored at -20 ℃ if not in use for a long time.2. Marking and detection(1) Centrifuge the collected cells, use 1 mL 1 × CFDA SE Buffer to re suspend the cells in a 15 mL centrifuge tube, and adjust the cell concentration to 1-5 × 106 cells/mL.(2) Preparation of CFDA SE working solution: Dilute the CFDA SE storage solution (1000 ×) with 1 × CFDA SE Buffer to 2 ×.(3) Staining: Add 1 mL of CFDA SE working solution (2 x) to 1 mL of cell suspension to be labeled, invert and mix well, and incubate at 37 ℃ for 10 minutes.(4) Immediately add 5 times the volume of preheated complete culture medium (including serum) to the centrifuge tube, invert and mix well to terminate the labeling reaction.(5) Centrifuge at 1000 rpm for 5 minutes at room temperature to remove the supernatant, then wash once with 5-10 mL of complete culture medium.(6) Add 5-10 mL of complete culture medium and incubate at 37 ℃ for 5 minutes to promote the residence of CFDA SE in the cells and the entry of unreacted CFDA SE into the complete cell culture medium. Centrifuge at 1000 rpm for 5 minutes at room temperature to remove the supernatant and complete the final wash.(7) Subsequently, the cells can be cultured using the normal cultivation method. The labeling effect can be directly observed under a fluorescence microscope, or cell proliferation can be detected by flow cytometry after appropriate cultivation time, showing green fluorescence. The labeled cells can also be used for transplantation in live animals and for fluorescence tracing.Note: a If cell fixation is required, use aldehyde fixatives such as 4% paraformaldehyde to fix at room temperature for 15 minutes; If additional labeling such as antibody labeling is required afterwards, please permeabilize the cells with ice acetone for 10 minutes. b. The optimal labeling concentration and incubation time for CFDA SE vary for different cells. The initial experiment can be conducted according to the experimental steps. If the effect is not satisfactory, it is recommended to adjust the staining concentration and incubation time to achieve the best labeling effect.Scope of application:Cell proliferation assay... Read More | EndoFree Plasmid Midi Kit Cat No. Component Size(50T) Storage E665631A Buffer P1 30 mL RT E665631B Buffer P2 30 mL RT E665631C Buffer E3 30 mL RT E665631D Buffer PS 15 mL RT E665631E Buffer PW (concentrate) 10 mL RT E665631F Endo-free Buffer EB 10 mL RTEndoFree Plasmid Midi Kit Cat No. Component Size(50T) Storage E665631A Buffer P1 30 mL RT E665631B Buffer P2 30 mL RT E665631C Buffer E3 30 mL RT E665631D Buffer PS 15 mL RT E665631E Buffer PW (concentrate) 10 mL RT E665631F Endo-free Buffer EB 10 mL RT E665631G RNase A (10 mg/mL) 600 µL RT E665631H Buffer ER 8 mL RT E665631I CWBlue 300 µL RT E665631J Spin Columns DL with Collection Tubes 50 EA RT E665631K Endo-Remover FM with Collection 50 EA RTProduct Introduction:Endotoxins are a common pollutant in plasmid extraction. Due to the high sensitivity of eukaryotic cells to endotoxins, the presence of endotoxins in plasmids can greatly reduce the transfection efficiency of eukaryotic cells. This reagent kit provides a simple, fast, and efficient new method for extracting endotoxin free plasmids. The extracted plasmids can remove endotoxins to the maximum extent possible and effectively remove contamination of genomic DNA, RNA, proteins, and other substances. This reagent kit is suitable for extracting 5-15mL of bacterial solution. On the basis of alkaline lysis of cells, it efficiently and specifically binds plasmid DNA through a new silicon-based membrane. Each adsorption column can adsorb up to 100 µ The plasmid DNA of g is effectively removed using a special buffer system and endotoxin removal filter column, effectively removing impurities such as endotoxins and proteins. The plasmid obtained from this kit has high purity and stable quality, making it particularly suitable for cell transfection. It can also be used for downstream experiments such as DNA sequencing, PCR, PCR based mutations, in vitro transcription, transformed bacteria, and endonuclease digestion.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1. All components can be stably stored in a dry, room temperature (15-30 ℃) environment for 1 year, and can be stored at 2-8 ℃ for longer periods of time. Buffer P1 with RNase A added can be stably stored at 2-8 ℃ for 6 months.2. Before the first use, add all RNase A solution to Buffer P1, mix well, and store at 2-8 ℃. Before use, let it sit at room temperature for a period of time. After returning to room temperature, use.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer P2 and Buffer E3. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. Be careful not to come into direct contact with Buffer P2 and Buffer E3, and immediately cover them tightly after use.6.The amount and purity of plasmid extraction are related to factors such as bacterial culture concentration, strain type, plasmid size, and plasmid copy number.Operation steps:1. Take 5-15 mL of overnight cultured bacterial solution and add it to a centrifuge tube (self provided). Centrifuge at 13000 rpm (~16200 × g) for 1 minute to collect bacteria, and try to discard all the supernatant as much as possible.2. Add 500 to the centrifuge tube containing bacterial sediment µ L Buffer P1 (please check if RNase A has been added first), mix thoroughly with a pipette or vortex oscillator, and suspend bacterial precipitation. Attention: If the bacterial blocks are not thoroughly mixed, it will affect the cracking effect, resulting in low extraction amount and purity.3. Add 500 to the centrifuge tube µ L Buffer P2, gently invert and mix 8-10 times, allowing the bacterial cells to fully lyse. Leave at room temperature for 3-5 minutes. At this point, the solution should become clear and viscous. Attention: Mix gently and do not shake vigorously to avoid interrupting genomic DNA and mixing genomic DNA fragments in the extracted plasmid. If the solution does not become clear, it indicates that the bacterial count may be too high and the lysis may not be complete. The bacterial count should be reduced.4. Add 500 to the centrifuge tube µ L Buffer E3, immediately invert and mix 8-10 times until white flocculent precipitates appear. Let it stand at room temperature for 5 minutes. Centrifuge at 13000 rpm for 5 minutes, extract the supernatant, and add it to the filter column (Endo Remove FM) (already loaded into the collection tube). Centrifuge at 13000 rpm for 1 minute to filter, then transfer the filtrate from the collection tube to the centrifuge tube (self provided). Attention: 1) After adding Buffer E3, it should be immediately mixed to avoid local precipitation. 2) The maximum volume of the adsorption column is 750 µ L. So please filter the supernatant twice and mix it in the same self provided centrifuge tube.5. Add 450 to the filtrate µ Mix L isopropanol upside down.6. Column balance: Add 200 to the spin columns DL that have been loaded into the collection tube µ L Buffer PS, centrifuge at 13000 rpm for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Transfer the mixed solution of filtrate and isopropanol from step 5 to an equilibrium adsorption column (already loaded into a collection tube). 8.13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. Attention: The maximum volume of the adsorption column is 750 µ L. So the solution obtained in step 5 is divided multiple times and passed through the column. 9. Add 750 to the adsorption column µ L Buffer PW (please check if anhydrous ethanol has been added first), centrifuge at 13000 rpm for 1 minute, and discard the waste liquid in the collection tube.10. Place the adsorption column back into the recovery manifold and centrifuge at 13000 rpm for 1 minute.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self provided)... Read More | DescriptionTakasago (R)-Ru Cymene Kit I comprises of ruthenium-based biphenyl phosphine cymene catalysts containing either BINAP and SEGPHOS®ligands. These highly reactive and selective catalysts are useful in a variety of asymmetric reactions, mainly asymmetric hydrogenation |