| Description | Inquire | Product contentG665801Component100 TStorageG665801A2×GoldStar Probe One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801BGoldStar Probe One Step EnzymeMix100 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801C50×High ROX50 µL-20Product contentG665801Component100 TStorageG665801A2×GoldStar Probe One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801BGoldStar Probe One Step EnzymeMix100 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801C50×High ROX50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801DRNase-Free Water1.5 mL-20℃. Avoid freeze/ Thaw cycle. Product Introduction This product is a specialized kit for one-step Real-Time RT-qPCR using the probe method (TaqMan, Molecular Beacon, etc.). When using this product for Real Time RT-qPCR reaction, reverse transcription and quantitative PCR are carried out in the same reaction system, and there is no need to add reagents or open the cap of the tube during the reaction process, which avoids contamination and improves the experimental efficiency at the same time. With high detection sensitivity, strong fluorescence signal and high signal-to-noise ratio, this product is very suitable for the detection of RNA viruses and other trace RNA. The special buffer system contained in this product can maximize the effectiveness of reverse transcriptase and DNA polymerase at the same time and improve the efficiency of the reaction. A wider linear range can be obtained with this product, more accurate quantification of the target gene, good reproducibility and high confidence.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument. Instruments that do not require ROX calibration (G665836) Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others. Instruments that require High ROX calibration (G665801) ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1.Before using the reagents in this kit, please mix them gently by turning them up and down to avoid foaming as much as possible, and use them after brief centrifugation.2.This product uses RNA as the template for one-step RT-PCR experiment, RNase contamination should be avoided during operation, it is recommended to operate RNA in a special area, use special instruments and consumables, the operator with a mask and disposable gloves and often change the gloves, the experiment-related consumables should be processed with 0.1% DEPC (diethyl ether pyrocarbonate) aqueous solution for 12 hours at 37℃, and autoclaved for 30 minutes before use. The consumables should be treated with 0.1% DEPC (diethylpyrocarbonate) aqueous solution at 37℃ for 12 hours and autoclaved for 30 minutes.3.Repeated freezing and thawing of each reagent in this kit should be avoided as much as possible; repeated freezing and thawing may degrade the product performance.4.This kit must use specific primers, the choice of primers can be selected according to specific experiments, the good or bad primer design directly affects the results of RT-qPCR reaction, the design of primers need to consider the GC content, primer length, primer position, the secondary structure of the PCR product and other factors, it is recommended to use a professional primer design software for design.5.This kit is recommended to use specific probes, and it is recommended to use professional design software for designing.UsageThe following examples are conventional reaction systems and conditions, which should be improved and optimized according to the different templates, primer structures and target fragment sizes in actual operation. (Please prepare the reaction solution on ice.)1. Dissolve RNA template, primers, 2× GoldStar Probe One Step Buffer, GoldStar Probe One Step EnzymeMix and RNase-Free Water and set aside on ice.2. PCR reaction system:reagents25µl reaction systemfinal concentration2×GoldStar Probe One Step Buffer12.5µl1×Forward Primer, 10µM0.5µl0.2µM¹⁾Reverse Primer, 10µM0.5µl0.2µM¹⁾Probe, 10µM0.5µl0.2µM²⁾GoldStar Probe One Step EnzymeMix1.0µl RNA TemplateXµl10pg-100ng³⁾50 x Low ROX or High ROX (optional)⁴⁾0.5µl1×RNase-Free WaterUp to 25µlNote: 1) Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.(2) The concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of RNA template is 10pg-100ng as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be diluted in gradient to determine the optimal amount of template to use.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.3. Mix well, centrifuge briefly, and collect the solution at the bottom of the tube.4.RT-PCR reaction conditions:Note: 1) The hot start enzyme used in this product must be activated under the condition of pre-denaturation 95℃, 5-10min. 2) It is recommended to use the two-step PCR reaction program, if you can not get good experimental results due to the use of primers with lower Tm value, etc., you can try to carry out the three-step PCR amplification, and the annealing temperature should be set in the range of 56℃-64℃ as a reference... Read More | DescriptionThe plasma protein lecithin:cholesterol acyltransferase (LCAT) catalyzes the transfer of an acyl group from the sn2 position of phosphatidylcholine to the 3-hydroxyl group of cholesterol forming cholesteryl ester. This activity occurs on the surface of high density lipoprotein (HDL) and DescriptionThe plasma protein lecithin:cholesterol acyltransferase (LCAT) catalyzes the transfer of an acyl group from the sn2 position of phosphatidylcholine to the 3-hydroxyl group of cholesterol forming cholesteryl ester. This activity occurs on the surface of high density lipoprotein (HDL) and the cholesteryl esters formed by LCAT are incorporated into the core of HDL.Preparation instructionsSuitable for high-throughput screening, mechanism of action studies and structureactivity relationship (SAR) work of LCAT in plasma and serumPrincipleThe LCFC-LCAT Acyltransferase Activity Assay is a fluorometric assay useful for measuring the acyltransferase activity of LCAT in serum or plasma. The method detects changes in LCAT free cholesterol (LCFC) levels in the sample without the use of c... Read More | N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917D DNA Standard B 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917E DNA Standard C 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917F DNA Standard D 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917G DNA Standard E 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis is a dye-based (SYBR Green I) qPCR NGS library quantification kit for cfDNA, which provides the reaction mixture, DNA primer mixture, standards, and sample dilutions required for the qPCR process, making it a complete reagent system that is easy and convenient to use. The fluorescent dye SYBR Green I contained in the reaction mixture binds to all double-stranded DNA. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, the length of the standard in the kit (about 270bp) is comparable to the average length of the cfDNA NGS libraries (250-300bp), which is able to quickly and accurately quantitate the concentration of the constructed cfDNA libraries. quantification.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.NOTE: High Rox and Low Rox are formulated as described in Method of Use 2.Applicable scopeThis product is designed for the absolute quantification of the concentration of Illumina platform second generation sequencing libraries. The end of the library contains Illumina P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.02pM can be used for quantitative experiments. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-60 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix0.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: 1 µl High Rox per 50 µl of reaction system; Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3.qPCR reaction programIf the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.Refer to the specific instrument setup program for dissolution curves.data analysisStandard curve productionThe standard curve was plotted according to the data processing Excel sheet. The correlation coefficient R2 of the standard curve should be not less than 0.99, and the slope should be located between -3.1 and -3.6 when the Ct value is the longitudinal coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard A60 pMDNA Standard B6 pMDNA Standard C0.6 pMDNA Standard D0.06 pMDNA Standard E0.006 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More | The fluorescent dye PKH67 is suitable for conventional cell membrane labeling. It is a green fluorescent dye that can track cells in vitro and in vivo. It labels cells by binding to the lipid components of the membrane structure. PKH67 has low cytotoxicity, low fluorescence background, high fat The fluorescent dye PKH67 is suitable for conventional cell membrane labeling. It is a green fluorescent dye that can track cells in vitro and in vivo. It labels cells by binding to the lipid components of the membrane structure. PKH67 has low cytotoxicity, low fluorescence background, high fat solubility, can easily penetrate cell membranes, and has strong and stable green fluorescence. PKH67-labeled cells can be used for in vitro and in vivo proliferation studies, and have the function of not staining neighboring cells. In the process of cell division and proliferation, the fluorescence intensity of PKH67 will gradually decrease as the cells divide. The labeled fluorescence can be evenly distributed to the two sub-generation cells, so its fluorescence intensity is half that of the parent cell. According to this feature, It can be used to detect cell proliferation, cell cycle estimation and cell division, etc. The fluorescence of PKH67-labeled cells is very uniform, and the fluorescence distribution of sub-generation cells after division is also more uniform. In the process of cell division and proliferation, PKH67-labeled fluorescence can be evenly distributed between the two sub-generation cells, and the fluorescence intensity becomes half of that of the parent cell. According to the difference in fluorescence intensity, the undivided cells can be detected by flow cytometry. One time (1/2 the fluorescence intensity), the second time (1/4 the fluorescence intensity), three times (1/8 the fluorescence intensity), and more divisions of cells. PKH67 can detect splits up to six times or even more. In addition to the detection of cell proliferation, PKH67 can also be used for in vitro tracking of cells. After labeling, the fluorescence expression is stable in the cell, and the positive labeling rate is over 98%. The labeled cells have good morphology, which can effectively observe the cells in vitro. Induce differentiation; or inject labeled cells into the body, it can effectively show the migration and differentiation of transplanted cells in living tissues. PKH67-labeled cells can be used for in vivo observation for as long as several weeks. It is often used for in vivo cell detection experiments and experiments to observe long-term cell activity using fluorescence electron microscope. PKH67 is less toxic and does not affect cell proliferation. This method is simple to operate, does not use radioactive isotopes, and poses no safety hazards. You can get the desired experimental data faster, more accurately and more safely.Due to the longer length of the charcoal tail, internal studies have shown that PKH67 is less transferred between cells than PKH2. In in vivo studies using PKH1 and PKH2, the fluorescence intensity will slowly lose. Since this is a behavioral characteristic of green cell linker dye rather than red cell linker dye, PKH67 will have similar properties. The correlation between the in vitro cell membrane retention of non-dividing cells and the in vivo fluorescence half-life reveals that the in vivo fluorescence half-life of PKH67 is 10-12 days. Other green cell linker dyes with similar half-lives have been used to monitor the transport of lymphocytes and macrophages in the body within one to two months. The results indicate that PKH67 can also be used for medium-term in vivo tracking studies.The dye can stably bind to the lipid region of the cell membrane and emit fluorescence, and is mainly used for cell labeling in vitro, cell proliferation research in vitro, and cell tracing research in vivo and in vitro. The fluorescence half-life of PKH67 in vivo is 10-12 days. Compared with PKH-67, PKH-26 has a longer half-life, and the half-life of PKH26 labeled on rabbit red blood cells is more than 100 days. Especially suitable for in vitro proliferation research and long-term in vivo cell tracking research. After PKH67 labels the cells, flow cytometry is usually used for cell proliferation detection.Kit components0.1ml kits: P266290A-0.1ml P266290B-10ml1ml kits: P266290A-1ml P266290B-60mlDyes with A suffix and diluents with B suffix are used togetherPKH67 labeled cells show green fluorescence, the fluorescence wavelength: λex=490 nm, λem=502 nm.Storage conditions: -20℃ protected from light, valid for 1 yearPrecautions●Staining concentration varies according to the type of cell and the number of cells in each well.● The prepared PKH67 mother liquor is very easy to dissolve. It is recommended to store in aliquots and freeze-dry at ≦-20℃.● PKH67 working solution should be prepared for immediate use, and cannot be prepared in advance, because PKH67 will decompose due to the absorption of water and affect the dyeing effect.● PKH67 is easily decomposed and will deteriorate quickly in the water solution. Please avoid contact with water during use of mother liquor. The working fluid is in contact with the water during the process of labeling the cells within the permitted time range.● PKH67 fluorescent dye is a DMSO solution. It will solidify and stick to the bottom, wall or cap of the tube at a lower temperature such as 4℃ and ice bath. After being taken out of the refrigerator, it will return to room temperature and become After the liquid is in the state, remove the cap from the bottom of the tube. It can be used after it has completely melted in a 37°C water bath.● The number of generations or time that can be traced after different cell types are marked is quite different. Please make a test based on the actual situation or reference documents.Instructions1. Staining solution preparation:(1) Take out the PKH67 reagent from the refrigerator, let it stand for a few minutes to room temperature, or after a 37°C water bath, leave the tube containing PKH67, and be sure to leave the tube for a few minutes before opening the lid to allow the reagent to fully fall into the tube The lid can only be opened after the bottom.(2) According to the number of cell samples to be tested, dilute the probe 10 times with the diluent, and then use a suitable solution (such as non-clear medium, HBSS or PBS) to dilute the PKH67 mother liquor 25 times to prepare a stain Work fluid. The best working solution concentration should be adjusted according to different cells and your own experimental system. Generally, the cells can be diluted 250 times according to the final concentration of the mother liquor in the kit. Some cells may need to increase the concentration appropriately.2. Cell staining(1) Resuspend the prepared cells to be tested in 100µl of staining solution to a cell concentration of about 107/ml. You can also perform in-situ staining, as long as the staining solution is enough to cover the cells.(2) Culture the cells at 2~8℃ for 15~30 minutes. The best culture time is different for different cells.It is recommended to incubate the labeled cells in the staining solution at 37°C for 5 minutes, and then at 4°C for 15 minutes.Low-temperature incubation can reduce the endocytosis of the dye by the cells, help the dye to label the plasma membrane, and reduce the possibility of the dye localizing to cytoplasmic vesicles.(3) After separation, remove the supernatant, collect the cells, wash the cells 1-2 times with PBS or non-clear medium, and finally add PBS or non-clear medium to resuspend the cells.(4) Take 500µl of cell suspension and test with flow cytometer. Ex/Em=490/502nm.(5) Subsequently, the cells can be cultured according to the normal culture method.(6) The labeling effect can be directly observed under a fluorescence microscope, or the cell proliferation can be detected by a flow cytometer after an appropriate period of culture, or used for cell fluorescence traces for other specific experimental purposes... Read More |