| Description | Product introduction:This kit uses an improved SDS alkaline lysis method combined with DNA preparation membrane to selectively adsorb DNA to achieve the purpose of rapid purification of plasmid DNA. It is suitable for extracting up to 500ug of high-purity plasmid DNA from 120-300ml bacterial Product introduction:This kit uses an improved SDS alkaline lysis method combined with DNA preparation membrane to selectively adsorb DNA to achieve the purpose of rapid purification of plasmid DNA. It is suitable for extracting up to 500ug of high-purity plasmid DNA from 120-300ml bacterial culture for sequencing, in vitro transcription and translation, restriction enzyme digestion, bacterial transformation and other molecular biology experiments.Scope of application:Nucleic acid extraction and purification... Read More | Inquire | Live & deadtm animal cell viability / toxicity detection kit (calcein am, ethd-i) is a kit that provides double fluorescent staining for the detection of animal cell death and survival. The two probes in the kit can respectively measure the activity of cellular lactonase and the integrity of Live & deadtm animal cell viability / toxicity detection kit (calcein am, ethd-i) is a kit that provides double fluorescent staining for the detection of animal cell death and survival. The two probes in the kit can respectively measure the activity of cellular lactonase and the integrity of plasma membrane to reflect cell viability. The kit can be used for fluorescence microscopy, flow cytometry, microplate reader and other fluorescence detection systems. This kit can be applied to most eukarYOtic mammalian cells, including some tissues with adherent nuclei, but it is not applicable to fungi and yeast. Compared with trypan blue, the kit is faster, safer and more sensitive.Component: Product parameters:Calcein am: ex/em = 494 / 517 nm; Ethd-i: ex/em = 528 / 617 nm (bound DNA)Usage:Fluorescence microscopy detection1. Prepare working fluidPreparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution: Remove the original solution of Calcein AM and EthD-I and restore them to room temperature. Add 20 µ L 2 mM EthD-I and 5 µ Mix 4 mM Calcein AM with 10 mL PBS or other serum-free buffer or culture medium, vortex well. The above working solution can be directly used for cell staining.Note: The aqueous solution of Calcein AM is easily hydrolyzed and should be used up every day. The concentration selection of Calcein AM and EthD-I varies depending on the type of cell used, with a recommended concentration range of 0.1-10 µ M.2. Prepare cells and conduct experiments(1) For adherent cells, they can be washed 2-3 times with 1 × PBS before staining. For suspended cells, centrifuge at room temperature of 250-1000 × g for 5 minutes and collect cells for staining.(2) Wash the cells thoroughly 2-3 times with 1 × PBS to remove residual esterase activity.(3) For adherent cells, add sufficient amount of Calcein AM/EthD-I staining solution. For suspended cells, add an appropriate amount of staining solution to control the cell density between 1-5 × 105/mL.(4) Incubate at room temperature in dark for 15-20 minutes (if the working solution concentration is high or the incubation temperature is high, the incubation time should be appropriately reduced).(5) Observe the labeled cells under a fluorescence microscope.Flow cytometry detection1. Remove the reagent and restore it to room temperature.2. Preparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution: Take out the original solution of Calcein AM and EthD-I, and restore to room temperature. Add 20 µ L 2 mMEthD-I and 5 µ Vortex mix 4 mM Calcein AM with 10 mL PBS or other serum-free buffer or culture medium. The working fluid can directly stain cells.3. Wash cells thoroughly 2-3 times with 1 × PBS.4. Suspend cells with 0.5 mL of staining solution and control the cell density to 1-5 × 105/mL.Note: It is recommended to prepare two additional cell samples, each containing only one dye (Calcein AM and EthD-I), for compensatory regulation of flow cytometry single staining; Prepare another cell sample containing only buffer solution (which should be consistent with the buffer used to prepare Calcein AM and EthD-I detection working solutions) as a negative control for flow cytometry analysis.5. Incubate at room temperature in dark for 15-20 minutes.6. Within 1-2 hours, cell activity was detected by flow cytometry. Calcein AM can be excited by a 488 nm laser, with fluorescence emission spectra detected at around 530 nm and EthD-I emission spectra at around 610 nm.Note: When using the cell circle gate, attention should be paid to excluding cell debris and using a single staining tube to regulate compensation. Double staining tube flow cytometry should obtain two relatively independent cell populations: a live cell population displaying green fluorescence and a dead cell population displaying red fluorescence.ELISA reader detection1. Cultivate an appropriate amount of adherent or suspended cells in a 96 well black ELISA plate.Note: Dead cells can be obtained by treating cells with 1% saponin or 0.1-0.5% digitalis saponin for 10 minutes.2. Preparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution:Remove the original solutions of Calcein AM and EthD-I and restore them to room temperature. Add 20 µ L 2 mM EthD-I and 5 µ Mix 4 mM Calcein AM 10 mL PBS or other serum-free buffer or culture medium, vortex well.Note: (1) 10 mL of staining solution is sufficient to stain a 96 well plate, and the volume of the staining solution can be adjusted according to experimental needs. The concentrations of Calcein AM and EthD-I can range from 0.1 to 10 µ Explore between M.(2) The aqueous solution of Calcein AM is easily hydrolyzed and should be used up every day. EthD-I working solution can be stored at -20 ℃ for at least one year.3. Wash the cells thoroughly with 1 × PBS to remove residual esterase activity. For adherent cells, add 100 to each well µ Wash cells with PBS. For suspended cells, add 100 µ Resuspend cells with L PBS and centrifuge to remove the supernatant. Repeat the above operation.4. Add 100 to each hole µ L PBS.5. Add 100 to each hole µ L staining solution, making the total volume of each well 200 µ L. The final concentration of Calcein AM is 1 µ M. The final concentration of EthD-I is 2 µ M. Gently shake the culture plate to evenly cover the cells with the liquid.Incubate at room temperature in dark for 30-45 minutes.Note: The optimal incubation time varies for different cells, with 30 minutes as the initial incubation time. Subsequently, the staining time can be adjusted and optimized according to the actual staining effect to obtain a more ideal staining effect.7. Enzyme reader detection. When the ELISA reader is set to fluorescein, it can detect Calcein AM; When the ELISA reader is set to rhodamine or Texas Red, EthD-I can be detected. Select the optimal emission and excitation wavelengths based on spectral characteristics.Note: By comparing the relative fluorescence values (RFU) measured between the sample group and the control group, the changes in the number of dead and live cells can be obtained. Another method of data analysis is also provided below.The following method can calculate the ratio of live cells to dead cells in a certain region. The required samples include dead cell control group, live cell control group, and the sample group to be tested. Dead cells can be obtained by treating cells with 1% saponin or 0.1-0.5% digitalis saponin for 10 minutes.1. Prepare staining solution and follow the above steps to stain cells. Additionally, prepare 1 mL and 2 mL separately µ M Calcein AM and 4 µ M EthD-I solution, stain the control group according to the following instructions. For the following groups of cells or cell-free groups, it is necessary to maintain complete consistency in cell count, detection of working solution concentration, incubation time, and incubation temperature.2. Measurement of sample group and control group:A. The measured values of the sample group at 645 nm are denoted as Calcein AM and EthD-I=F (645) sam.B. The measured values of the sample group at 530 nm are denoted as Calcein AM and EthD-I=F (530) sam.C. The measurement value of dead cell EthD-I single staining control group at 645 nm is denoted as EthD-I=F (645) maxD. The measurement value of dead cell Calcein AM single staining control group at 645 nm is recorded as Calcein AM=F (645) minE. The measurement value of live cell EthD-I single staining control group at 530 nm is recorded as EthD-I=F (530) min.F. The measurement value of live cell Calcein AM single staining control group at 530 nm is denoted as Calcein AM=F (530) max.G. A blank control well without cells (with or without dye), the detection value at 530 nm is recorded as F (530) 0.H. A blank control well without cells (with or without dye), the detection value at 645 nm is recorded as F (645) 0.3. Calculate the ratio of dead cells to live cells based on measurement data:%Live Cells=(B-E) ÷ (F-E)%Dead Cells=(A-D) ÷ (C-D)Determine the ratio of live cells to dead cells in a certain areaBy creating fluorescence spectral standard curves at 530 nm and 645 nm, the number of dead and live cells can be determined, and the fluorescence intensity of each dye is linearly related to the number of dead or live cells in the sample.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. phenol red or serum may interfere with the detection of this kit. 3. fluorescent dyes have quenching problems. Please try to avoid light during experimental operation to slow down fluorescence quenching. 4. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Dead and live cell staining (animal)... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Collection Tubes50 sets 200 setsRTS666146HCentrifuge Tubes (1.5 mL)50 EA200 EARTProductsThis kit provides a simple and rapid method for the isolation and purification of total DNA from buccal swab samples. The kit adopts a silica matrix membrane that can specifically bind DNA and a unique buffer system to adsorb DNA efficiently and specifically, and 0.5-3.5 µg of genomic DNA can be obtained from each swab, and the extracted DNA fragments are large, pure and of stable and reliable quality. It is suitable for enzyme digestion, PCR, library construction, Southern hybridization and other experiments.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.2. If precipitation is found in Buffer GL before use, dissolve Buffer GL in a 56°C water bath.3. All centrifugation steps can be performed at room temperature.4. Sampling: Use a buccal swab to wipe the inside of the mouth 6 times, dry for 2 hours and store. To ensure that the sample is not contaminated by food or drink, do not eat or drink for 30 minutes before sampling.Procedure1. The swab of the buccal swab was cut from the rod with scissors and placed in a 2mL centrifuge tube (supplied) and 400µL Buffer GR was added.Note: For genomic DNA without RNA contamination, add 4 µL of RNase A solution at a concentration of 100 mg/ml and shake to mix.2. Add 20 µL of Proteinase K and 400 µL of Buffer GL, immediately vortex and shake for 15 seconds and mix thoroughly.Note: Mix well immediately after adding Buffer GL; do not add Proteinase K directly to Buffer GL for use.3.56°C for 10 minutes and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.4. Add 400 µL of anhydrous ethanol, vortex and shake to mix thoroughly, and centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube.Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.5. Add the solution and precipitate obtained in the previous step to the Spin Columns DS in two batches of up to 700 µL at a time into the collection tube. centrifuge the column at 12,000 rpm (∼13,400 × g) for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.6. Add 500 µL of Buffer GW1 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.7. Add 500 µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge the column at 12,000 rpm for 3 minutes, pour off the waste liquid in the collection tube, and put the column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 1 minute and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new 1.5 mL centrifuge tube, add 50 µL of Buffer GE or sterilized water to the middle of the adsorption column overhanging the column, let stand at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store at -20℃.Attention:(1) If the downstream experiment is sensitive to pH or EDTA, it can be eluted with sterilized water. The pH value of the eluent has a great influence on the elution efficiency. If the eluent is made of water, the pH value should be 7.0-8.5 (the pH value of water can be adjusted to this range by using NaOH), and the elution efficiency is not high when the pH value is lower than 7.0.2) For long-term storage, it is recommended to elute with Buffer GE and store at -20°C... Read More |