| Description | Products content S666097Component200 TStorageS666097A5×SuperFast One Step RT-qPCR U+ Buffer1 mL-20℃. Avoid freeze/thaw cycle.S666097BSuperFast One Step U+ Enzyme200 µL-20℃. Avoid freeze/thaw cycle.S666097CRNase-Free Water2×1.5 mL-20℃. Avoid freeze/thaw cycle. Products content S666097Component200 TStorageS666097A5×SuperFast One Step RT-qPCR U+ Buffer1 mL-20℃. Avoid freeze/thaw cycle.S666097BSuperFast One Step U+ Enzyme200 µL-20℃. Avoid freeze/thaw cycle.S666097CRNase-Free Water2×1.5 mL-20℃. Avoid freeze/thaw cycle. Products IntroductionThe SuperFast Probe One Step RT-qPCR U+ Kit is designed for quantitative PCR assays using RNA as a template (e.g., RNA viruses). Using gene-specific primers (GSP), reverse transcription and qPCR reactions are completed in a single tube, eliminating the need for additional tube-opening/pipetting operations, greatly increasing throughput and reducing the risk of contamination. The dUTP/UNG anti-contamination system is introduced in this kit. The heat-sensitive UNG rapidly degrades U-containing contaminants at room temperature; it is rapidly inactivated by reverse transcription at 55°C, without affecting the efficiency and sensitivity of qRT-PCR. Combined with optimized buffer systems and antibody-modified Taq enzymes and mutated M-MLV, the SuperFast Probe One Step RT-qPCR U+ Kit provides sensitivity up to 0.1 pg of total RNA or <10 copies of RNA template and enhanced thermal stability. 5× SuperFast One Step RT-qPCR U+ Buffer contains the following components The 5× SuperFast One Step RT-qPCR U+ Buffer contains an optimized buffer system and dNTP/dUTP Mix, which is particularly suitable for high specificity, low template concentration and multiplexed rapid detection of fluorescently labeled probes such as TaqMan. caveatBefore use, please mix the product gently by turning it up and down after it is completely melted to avoid foaming, and use it after brief centrifugation. Avoid repeated freezing and thawing of the product.ROX dye is used to correct the fluorescence signal error between the quantitative PCR wells, this product does not contain ROX dye, if you need to match the ROX dye with the instrument you are using, please contact your local business or call CombiSense customer service at 4006-222-360. PCR reaction system Attention: (1) Usually, the final primer concentration of 0.2 µM can get better results, and 0.1-1.0 µM can be used as a reference for setting the range. If the amplification efficiency is not high, the concentration of primer can be increased; if non-specific reaction occurs, the concentration of primer can be decreased to optimize the reaction system.(2) The final concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe to adjust the concentration.3) Because templates from different species contain different numbers of copies of the target gene, the template can be diluted in a gradient to determine the optimal amount of template to usePCR reaction conditionsmovetemptimingcirculatereverse transcription55°C1 min1premutability95°C10s1)1denaturation95°C1 s40-45Annealing/Extension55-60°C2)10-15s3)40-45Attention: (1) The enzyme used in this product is activated under the condition of pre-denaturation at 95℃ for 30s. Under this condition, most of the templates can be well unchained. For templates with high GC content and complex secondary structure, the pre-denaturation time can be extended to 1min, so as to make the starting template fully unchained, and if the high temperature treatment time is too long, it will affect the activity of the enzyme; for simple templates, pre-denaturation time of 1-10s can also be used, and the optimal pre-denaturation time can be determined according to the template situation.(2) It is recommended to use two-step PCR reaction program, the annealing temperature should be 55-60℃ as the reference range, and the annealing temperature can be increased when non-specific reaction occurs. If you can't get good results due to the use of primers with low Tm values or long amplification products, you can try three-step PCR amplification.3) Whether the actual Real Time PCR instrument used supports rapid amplification cycles, please perform a pre-experiment to verify this for the first attempt... Read More | B665530 Component 50 T 200 T Storage B665530A Buffer RCL 125 mL 2×260 mL 2-8℃ B665530B Buffer GR 15 mL 50 mL RT B665530C Buffer GL 15 mL 50 mL RT B665530D Buffer GW1 (concentrate) 13 mL 52 mL RT B665530E Buffer GW2 (concentrate) 15 mL 50 mL RT B665530F Buffer GE 15 mL 60 mL RT B665530G B665530 Component 50 T 200 T Storage B665530A Buffer RCL 125 mL 2×260 mL 2-8℃ B665530B Buffer GR 15 mL 50 mL RT B665530C Buffer GL 15 mL 50 mL RT B665530D Buffer GW1 (concentrate) 13 mL 52 mL RT B665530E Buffer GW2 (concentrate) 15 mL 50 mL RT B665530F Buffer GE 15 mL 60 mL RT B665530G Proteinase K 1.25 mL 4×1.25 mL RT B665530H Spin Columns DM with Collection Tubes 50 sets 200 sets RTProduct IntroductionThis reagent kit is suitable for extracting total DNA, including genomic DNA, mitochondrial DNA, and viral DNA, from fresh or frozen whole blood (blood samples treated with anticoagulants such as citrate, EDTA, or heparin), plasma, serum, erythrocyte sedimentation rate brown layer, lymphocytes, cell-free body fluids, and other samples. This product can process 0.1-1 mL of whole blood with a maximum yield of 30% µ g. It can purify DNA with sizes ranging from 100 bp to 50 kb. The purified DNA has high yield and good quality, and can remove protein, pigment, lipid, and other inhibitory impurities to the maximum extent. It can be directly used for PCR, fluorescence quantitative PCR, enzyme digestion, and Southern Blot experiments.Self prepared reagent: anhydrous ethanol.Preparation and important precautions before the experiment:1. The sample should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2. This reagent kit can extract up to 0.1-1 mL of whole blood samples or 1 × 107 white blood cells.3.Before the first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in the Buffer GL. If there is any crystallization or precipitation, please incubate the Buffer GL in a 56 ℃ water bath and dissolve it again.5. The Buffer RCL in the reagent kit cannot be used again after being turbid.Operation steps:1. Sample processing: 1a When extracting 200 uL of blood sample, add the sample to the centrifuge tube (provided) and proceed directly to the next step of the experiment. 1b When the blood sample size is less than 200 µ When L, add Buffer GR to make up for 200 µ L. Proceed to the next step of the experiment. 1c When the blood sample size exceeds 200 µ When L is reached, add 1-2 times the volume of Buffer RCL, gently vortex or invert and mix well. Centrifuge at 12000 rpm (~13400 × g) for 1 minute and carefully discard the supernatant. If there is still red in the sediment, repeat the above steps once. Then add 200 to the precipitate µ Shake the buffer GR until thoroughly mixed before proceeding to the next step of the experiment. 1d If the processed blood sample is anticoagulant from poultry, birds, amphibians, or lower level organisms, its red blood cells are nucleated cells, and the blood sample size is 5-20 µ L. Can be added to Buffer GR to make up to 200 µ Follow up experiments will be conducted afterwards. Note: If downstream experiments are sensitive to RNA, 4 can be added µ L RNase A (100mg/mL) solution, shake for 15 seconds, and leave at room temperature for 5 minutes. RNase A reagent kit is not provided. If needed, you can order it separately from our company, item number: CW0601S.2. Add 20 to the above solution µ L Protein K, mix well.3. Add 200 µ Shake with L Buffer GL until thoroughly mixed. Note: Do not pre mix Protein K and Buffer GL.4.Incubate at 4.56 ℃ for 10 minutes, invert and mix several times during this time. Attention: The DNA production has reached its maximum after 10 minutes of incubation, and further extension of incubation time has no effect on DNA production and purity.5. Add 200 µ L anhydrous ethanol, invert and mix several times. Short centrifugation causes the liquid on the tube wall and wall cover to concentrate at the bottom of the tube.6. Add all the solution obtained in step 5 to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. Note: If the extracted sample is the blood genome of species such as mice or monkeys that are difficult to remove heme, it is recommended to repeat step 7.8. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. Note: To further improve DNA purity, repeat step 8.9.Centrifuge at 9.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.)10. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃. Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high. 2) If the final concentration of DNA needs to be increased, the obtained DNA eluent can be added back to the adsorption membrane, left at room temperature for 2-5 minutes, and centrifuged at 12000 rpm for 1 minute. 3) Because DNA stored in water is affected by acidic hydrolysis, if long-term storage is required, it is recommended to elute with Buffer GE and store at -20 ℃... Read More | Product content:E665636Component50 TStorageE665636ABuffer P115 mLRTE665636BBuffer P215 mLRTE665636CBuffer E315 mLRTE665636DBuffer PS15 mLRTE665636EBuffer PW (concentrate)10 mLRTE665636FEndo-Free Buffer EB10 mLRTE665636GRNase A (10 mg/mL)150 µLRTE665636HEndo-Remover FMwith Collection Tubes50 Product content:E665636Component50 TStorageE665636ABuffer P115 mLRTE665636BBuffer P215 mLRTE665636CBuffer E315 mLRTE665636DBuffer PS15 mLRTE665636EBuffer PW (concentrate)10 mLRTE665636FEndo-Free Buffer EB10 mLRTE665636GRNase A (10 mg/mL)150 µLRTE665636HEndo-Remover FMwith Collection Tubes50 EARTE665636ISpin Columns DMwith Collection Tubes50 EART Product Introduction:Endotoxins are a common pollutant in plasmid extraction. Due to the high sensitivity of eukaryotic cells to endotoxins, the presence of endotoxins in plasmids can greatly reduce the transfection efficiency of eukaryotic cells. This reagent kit provides a simple, fast, and efficient new method for extracting endotoxin free plasmids. The extracted plasmids remove endotoxins to the maximum extent possible and can effectively remove contamination of genomic DNA, RNA, proteins, etc. The operation is simple and convenient. This reagent kit is suitable for extracting 1-5mL of bacterial solution. On the basis of alkaline lysis of cells, it efficiently and specifically binds plasmid DNA through a new silicon-based membrane. Each adsorption column can adsorb up to 40% µ The plasmid DNA of g is effectively removed using a special buffer system and endotoxin removal filter column, effectively removing impurities such as endotoxins and proteins. The plasmid obtained from this kit has high purity and stable quality, making it particularly suitable for cell transfection. It can also be used for downstream experiments such as DNA sequencing, PCR, PCR based mutations, in vitro transcription, transformed bacteria, and endonuclease digestion.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1. All components can be stably stored for 1 year in a dry, room temperature (15-30 ℃) environment. The adsorption column can be stored for a longer time at 2-8 ℃. Buffer P1 with RNase A added can be stably stored for 6 months at 2-8 ℃. 2. Before the first use, add all RNase A solution to Buffer P1, mix well, and store at 2-8 ℃. Before use, let it sit at room temperature for a period of time. After returning to room temperature, use.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer P2 and Buffer E3. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. Be careful not to come into direct contact with Buffer P2 and Buffer E3, and immediately cover them tightly after use.6.The amount and purity of plasmid extraction are related to factors such as bacterial culture concentration, strain type, plasmid size, and plasmid copy number.Operation steps:1. Take 1-5 mL of overnight cultured bacterial solution and add it to a centrifuge tube (provided). Centrifuge at 13000 rpm (~16200 × g) for 30 seconds to collect bacteria, and try to discard all the supernatant as much as possible.2. Add 250 to the centrifuge tube containing bacterial sediment µ L Buffer P1 (please check if RNase A has been added first), mix thoroughly with a pipette or vortex oscillator, and suspend bacterial precipitation.Attention: If the bacterial blocks are not thoroughly mixed, it will affect the cracking effect, resulting in low extraction amount and purity.3. Add 250 to the centrifuge tube µ L Buffer P2, gently invert and mix 8-10 times, allowing the bacterial cells to fully lyse. Leave at room temperature for 3-5 minutes. At this point, the solution should become clear and viscous.Attention: Mix gently and do not shake vigorously to avoid interrupting genomic DNA and mixing genomic DNA fragments in the extracted plasmid. If the solution does not become clear, it indicates that the bacterial count may be too high and the lysis may not be complete. The bacterial count should be reduced.4. Add 250 to the centrifuge tube µ L Buffer E3, immediately invert and mix 8-10 times until white flocculent precipitates appear. Let it stand at room temperature for 5 minutes. Centrifuge at 13000 rpm for 5 minutes, extract the supernatant, and add it to a filter column (Endo Remove FM). Centrifuge at 13000 rpm for 1 minute to filter, and collect the filtrate in a centrifuge tube (self provided).Attention: After adding Buffer E3, it should be mixed evenly immediately to avoid local precipitation. 5. Add 225 to the filtrate µ Mix L isopropanol upside down.6. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ L Buffer PS, centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Transfer the mixed solution of filtrate and isopropanol from step 5 to an equilibrium adsorption column (already loaded into a collection tube).8.13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Attention: The maximum volume of the adsorption column is 750 µ L. If the sample volume is greater than 750 µ L can be added in batches. 9. Add 750 to the adsorption column µ L Buffer PW (please check if anhydrous ethanol has been added first), centrifuge at 13000 rpm for 1 minute, and discard the waste liquid in the collection tube.10. Place the adsorption column back into the recovery manifold and centrifuge at 13000 rpm for 1 minute. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new collection tube and add 50-100 to the middle of the adsorption membrane µ L Endo Free Buffer EB, let it stand at room temperature for 2-5 minutes, centrifuge at 13000 rpm for 2 minutes, and collect the plasmid solution into a centrifuge tube- Store the plasmid at 20 ℃.Note: 1) To increase the efficiency of plasmid recovery, the obtained solution can be added back to the adsorption column, left at room temperature for 2-5 minutes, centrifuged at 13000 rpm for 2 minutes, and collected into a centrifuge tube.2) When the plasmid copy number is low or>10 kb, preheating the Endo Free Buffer EB in a water bath at 65-70 ℃ can increase the extraction efficiency... Read More | Inquire | Inquire |