| Description | Products content S666097Component200 TStorageS666097A5×SuperFast One Step RT-qPCR U+ Buffer1 mL-20℃. Avoid freeze/thaw cycle.S666097BSuperFast One Step U+ Enzyme200 µL-20℃. Avoid freeze/thaw cycle.S666097CRNase-Free Water2×1.5 mL-20℃. Avoid freeze/thaw cycle. Products content S666097Component200 TStorageS666097A5×SuperFast One Step RT-qPCR U+ Buffer1 mL-20℃. Avoid freeze/thaw cycle.S666097BSuperFast One Step U+ Enzyme200 µL-20℃. Avoid freeze/thaw cycle.S666097CRNase-Free Water2×1.5 mL-20℃. Avoid freeze/thaw cycle. Products IntroductionThe SuperFast Probe One Step RT-qPCR U+ Kit is designed for quantitative PCR assays using RNA as a template (e.g., RNA viruses). Using gene-specific primers (GSP), reverse transcription and qPCR reactions are completed in a single tube, eliminating the need for additional tube-opening/pipetting operations, greatly increasing throughput and reducing the risk of contamination. The dUTP/UNG anti-contamination system is introduced in this kit. The heat-sensitive UNG rapidly degrades U-containing contaminants at room temperature; it is rapidly inactivated by reverse transcription at 55°C, without affecting the efficiency and sensitivity of qRT-PCR. Combined with optimized buffer systems and antibody-modified Taq enzymes and mutated M-MLV, the SuperFast Probe One Step RT-qPCR U+ Kit provides sensitivity up to 0.1 pg of total RNA or <10 copies of RNA template and enhanced thermal stability. 5× SuperFast One Step RT-qPCR U+ Buffer contains the following components The 5× SuperFast One Step RT-qPCR U+ Buffer contains an optimized buffer system and dNTP/dUTP Mix, which is particularly suitable for high specificity, low template concentration and multiplexed rapid detection of fluorescently labeled probes such as TaqMan. caveatBefore use, please mix the product gently by turning it up and down after it is completely melted to avoid foaming, and use it after brief centrifugation. Avoid repeated freezing and thawing of the product.ROX dye is used to correct the fluorescence signal error between the quantitative PCR wells, this product does not contain ROX dye, if you need to match the ROX dye with the instrument you are using, please contact your local business or call CombiSense customer service at 4006-222-360. PCR reaction system Attention: (1) Usually, the final primer concentration of 0.2 µM can get better results, and 0.1-1.0 µM can be used as a reference for setting the range. If the amplification efficiency is not high, the concentration of primer can be increased; if non-specific reaction occurs, the concentration of primer can be decreased to optimize the reaction system.(2) The final concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe to adjust the concentration.3) Because templates from different species contain different numbers of copies of the target gene, the template can be diluted in a gradient to determine the optimal amount of template to usePCR reaction conditionsmovetemptimingcirculatereverse transcription55°C1 min1premutability95°C10s1)1denaturation95°C1 s40-45Annealing/Extension55-60°C2)10-15s3)40-45Attention: (1) The enzyme used in this product is activated under the condition of pre-denaturation at 95℃ for 30s. Under this condition, most of the templates can be well unchained. For templates with high GC content and complex secondary structure, the pre-denaturation time can be extended to 1min, so as to make the starting template fully unchained, and if the high temperature treatment time is too long, it will affect the activity of the enzyme; for simple templates, pre-denaturation time of 1-10s can also be used, and the optimal pre-denaturation time can be determined according to the template situation.(2) It is recommended to use two-step PCR reaction program, the annealing temperature should be 55-60℃ as the reference range, and the annealing temperature can be increased when non-specific reaction occurs. If you can't get good results due to the use of primers with low Tm values or long amplification products, you can try three-step PCR amplification.3) Whether the actual Real Time PCR instrument used supports rapid amplification cycles, please perform a pre-experiment to verify this for the first attempt... Read More | Inquire | Inquire | Products contentN665993Component240 TStorageN665993AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/ Thaw cycle.N665993BIndex N925-N948 Primers for Illumina24×10 µL-20℃. Avoid freeze/ Thaw cycle. Products Introduction This kit is a companion kit to the transposase-Products contentN665993Component240 TStorageN665993AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/ Thaw cycle.N665993BIndex N925-N948 Primers for Illumina24×10 µL-20℃. Avoid freeze/ Thaw cycle. Products Introduction This kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Illumina platform library construction. Each kit contains one N5 primer and 24 N7 primers, which can be used to prepare 24 different single-ended Index libraries. All reagents provided in the kits have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes;Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers. ProcedureFor the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol.Index N501 Primer for IlluminaIndex N901-N996 Primer for Illumina... Read More | Product contentU665751Component100 TStorageU665751A2×UltraSYBR One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751BUltraSYBR One Step EnzymeMix50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751C50×High ROX50 µL-20℃. AvoidProduct contentU665751Component100 TStorageU665751A2×UltraSYBR One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751BUltraSYBR One Step EnzymeMix50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751C50×High ROX50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751DRNase-Free Water1.5 mL-20℃. Avoid freeze/ Thaw cycle. Product Introduction This product is a specialized kit for one-step Real-Time RT-qPCR. The SYBR Green I fluorescent dye contained can bind to all double-stranded DNA, allowing this product to be used for the detection of many different target sequences without the need to synthesize specific labeling probes. Real Time RT-qPCR reaction using this product, reverse transcription and quantitative PCR are carried out in the same reaction system, there is no need to add reagents during the reaction, no need to open the cap of the tube, avoiding contamination while improving the efficiency of the experiment. The new high-efficiency reverse transcriptase RNase H is activity-deficient, which reduces the degradation of RNA in the reverse transcription reaction. The enzyme has high reverse transcription efficiency and can perform a good reverse transcription reaction on a small amount of RNA template. It has high affinity to RNA and can read through RNA templates with high GC content and complex secondary structure. New efficient hot start enzyme, the enzyme activity is closed at room temperature, thus effectively avoiding non-specific amplification caused by non-specific binding of primers and templates or primer dimerization at room temperature, which greatly improves the accuracy of fluorescence quantitative PCR reaction. The included buffer system maximizes the efficacy of both enzymes at the same time and improves efficiency. This product has high sensitivity, high specificity, wide linear range, and more accurate quantification of target genes.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used with Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument. Instruments that do not require ROX calibration (U665567) Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others. Instruments that require High ROX calibration (U665751) ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1. Before using the reagents in this kit, please mix them gently by turning them up and down to avoid foaming as much as possible, and use them after brief centrifugation.2. This product uses RNA as the template for one-step RT-PCR experiment, RNase contamination should be avoided during operation, it is recommended to operate RNA in a special area, use special instruments and consumables, the operator with a mask and disposable gloves and often change the gloves, the experiment-related consumables should be processed with 0.1% DEPC (diethyl ether of pyrocarbonate) aqueous solution at 37℃ for 12 hours and autoclaved for 30 minutes before use. Sterilize for 30 minutes before use.3. UltraSYBR One Step RT-qPCR Buffer contains SYBR Green I fluorescent dye. Avoid bright light when storing this product or preparing PCR reaction solutions.4. Repeated freezing and thawing of each reagent in this kit should be avoided; repeated freezing and thawing may degrade the product performance. This product can be stored for a long time at -20℃, protected from light. If frequent use is required in the short term, it can be stored at 2-8℃.5. This kit must use specific primers, the choice of primers can be selected according to specific experiments, the good or bad primer design directly affects the results of RT-PCR reaction, the design of primers need to consider the GC content, primer length, primer position, the secondary structure of the PCR product and other factors, it is recommended to use a professional primer design software for design.6. This product cannot be used for fluorescent quantitative PCR by the probe method.Usage1. Dissolve RNA template, primers, 2× UltraSYBR One Step Buffer, UltraSYBR One Step EnzymeMix and RNase-Free Water and set aside on ice.2. PCR reaction system:Reagents25 µl Reaction systemFinal concentration2×UltraSYBR One Step Buffer12.5 µl1×Forward Primer,10 µM0.5 µl0.2 µM¹⁾Reverse Primer,10 µM0.5 µl0.2 µM¹⁾UltraSYBR One Step EnzymeMix0.5 µl RNA TemplateX µl10 pg – 100 ng50×Low ROX or High ROX(optional)2)0.5 µl1×RNase-Free Waterup to 25 µlNote: 1) Usually, the primer concentration of 0.2µM can get better results, and the final concentration of 0.1-0.5µM can be used as a reference for setting the range. If the amplification efficiency is not high, the concentration of primer can be increased; when non-specific reaction occurs, the concentration of primer can be decreased, thus optimizing the reaction system.(2) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.3. Vortex and shake to mix, centrifuge briefly, and collect the solution at the bottom of the tube.4. RT-qPCR reaction conditions (fluorescence quantitative PCR is a two-step method), this program is based on the ABI 7500 fluorescence quantitative PCR instrument as an exampleNote: 1) It is recommended to use two-step PCR reaction program, if you improve the reaction specificity, you can increase the annealing temperature to 60-64 ℃ as a reference for the setting range; if you do not get good experimental results due to the use of primers with lower Tm values, etc., you can try to carry out three-step PCR amplification.(2) For melting curve analysis, please set up the program recommended by the fluorescence quantitative PCR instrument used, and this program is set up with the ABI 7500 fluorescence quantitative PCR instrument as a reference.RT-qPCR reaction conditions (fluorescence quantitative PCR was a three-step method):Note: 1) For three-step PCR amplification, please use the range of 56℃-64℃ as the setting reference for the annealing temperature.(2) For melting curve analysis, please set up the program recommended by the fluorescence quantitative PCR instrument you are using, this program is ABI750 fluorescent quantitative PCR instrument as a reference setting... Read More |