| Description | Inquire | Alanine Aminotransferase (ALT), also known as serum glutamic-pyruvic transaminase (SGPT), is a pyridoxal-phosphate-dependent enzyme that catalyzes the reversible transfer of an amino group from alanine to α-ketoglutarate, generating pyruvate and glutamate. ALT is found primarily in liver and Alanine Aminotransferase (ALT), also known as serum glutamic-pyruvic transaminase (SGPT), is a pyridoxal-phosphate-dependent enzyme that catalyzes the reversible transfer of an amino group from alanine to α-ketoglutarate, generating pyruvate and glutamate. ALT is found primarily in liver and serum, but occurs in other tissues as well. Hepatocellular injury often results in an increase of serum ALT levels and serum ALT levels can be used as a marker for liver injury.ALT Activity Assay kit has been used to determine the activity of alanine aminotransferase (ALT) in serum samples... Read More | Product contentG665801Component100 TStorageG665801A2×GoldStar Probe One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801BGoldStar Probe One Step EnzymeMix100 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801C50×High ROX50 µL-20Product contentG665801Component100 TStorageG665801A2×GoldStar Probe One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801BGoldStar Probe One Step EnzymeMix100 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801C50×High ROX50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801DRNase-Free Water1.5 mL-20℃. Avoid freeze/ Thaw cycle. Product Introduction This product is a specialized kit for one-step Real-Time RT-qPCR using the probe method (TaqMan, Molecular Beacon, etc.). When using this product for Real Time RT-qPCR reaction, reverse transcription and quantitative PCR are carried out in the same reaction system, and there is no need to add reagents or open the cap of the tube during the reaction process, which avoids contamination and improves the experimental efficiency at the same time. With high detection sensitivity, strong fluorescence signal and high signal-to-noise ratio, this product is very suitable for the detection of RNA viruses and other trace RNA. The special buffer system contained in this product can maximize the effectiveness of reverse transcriptase and DNA polymerase at the same time and improve the efficiency of the reaction. A wider linear range can be obtained with this product, more accurate quantification of the target gene, good reproducibility and high confidence.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument. Instruments that do not require ROX calibration (G665836) Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others. Instruments that require High ROX calibration (G665801) ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1.Before using the reagents in this kit, please mix them gently by turning them up and down to avoid foaming as much as possible, and use them after brief centrifugation.2.This product uses RNA as the template for one-step RT-PCR experiment, RNase contamination should be avoided during operation, it is recommended to operate RNA in a special area, use special instruments and consumables, the operator with a mask and disposable gloves and often change the gloves, the experiment-related consumables should be processed with 0.1% DEPC (diethyl ether pyrocarbonate) aqueous solution for 12 hours at 37℃, and autoclaved for 30 minutes before use. The consumables should be treated with 0.1% DEPC (diethylpyrocarbonate) aqueous solution at 37℃ for 12 hours and autoclaved for 30 minutes.3.Repeated freezing and thawing of each reagent in this kit should be avoided as much as possible; repeated freezing and thawing may degrade the product performance.4.This kit must use specific primers, the choice of primers can be selected according to specific experiments, the good or bad primer design directly affects the results of RT-qPCR reaction, the design of primers need to consider the GC content, primer length, primer position, the secondary structure of the PCR product and other factors, it is recommended to use a professional primer design software for design.5.This kit is recommended to use specific probes, and it is recommended to use professional design software for designing.UsageThe following examples are conventional reaction systems and conditions, which should be improved and optimized according to the different templates, primer structures and target fragment sizes in actual operation. (Please prepare the reaction solution on ice.)1. Dissolve RNA template, primers, 2× GoldStar Probe One Step Buffer, GoldStar Probe One Step EnzymeMix and RNase-Free Water and set aside on ice.2. PCR reaction system:reagents25µl reaction systemfinal concentration2×GoldStar Probe One Step Buffer12.5µl1×Forward Primer, 10µM0.5µl0.2µM¹⁾Reverse Primer, 10µM0.5µl0.2µM¹⁾Probe, 10µM0.5µl0.2µM²⁾GoldStar Probe One Step EnzymeMix1.0µl RNA TemplateXµl10pg-100ng³⁾50 x Low ROX or High ROX (optional)⁴⁾0.5µl1×RNase-Free WaterUp to 25µlNote: 1) Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.(2) The concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of RNA template is 10pg-100ng as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be diluted in gradient to determine the optimal amount of template to use.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.3. Mix well, centrifuge briefly, and collect the solution at the bottom of the tube.4.RT-PCR reaction conditions:Note: 1) The hot start enzyme used in this product must be activated under the condition of pre-denaturation 95℃, 5-10min. 2) It is recommended to use the two-step PCR reaction program, if you can not get good experimental results due to the use of primers with lower Tm value, etc., you can try to carry out the three-step PCR amplification, and the annealing temperature should be set in the range of 56℃-64℃ as a reference... Read More | This reagent kit uses highly sensitive silver dye, which can be applied to protein staining of denatured and non denatured gels. It has the advantages of clear target bands, low background, and flexible control of operation time. In addition, this reagent kit has added a short-term sensitization This reagent kit uses highly sensitive silver dye, which can be applied to protein staining of denatured and non denatured gels. It has the advantages of clear target bands, low background, and flexible control of operation time. In addition, this reagent kit has added a short-term sensitization step, which can significantly reduce the background and enhance the brightness of the target band. P665901Component20 TStorageP665901ASilver Stain Sensitizer (500×)2×1 mLRTP665901BSilver Stain Enhancer3 mLRTP665901CSilver Stain2×250 mLRTP665901DSilver Stain Developer4×125 mLRT Matters needing attention1. Please prepare 50 ml of fixed solution (ultrapure water: ethanol: acetic acid=6:3:1), 50 ml of eluent (10% ethanol), and 50 ml of termination solution (5% acetic acid) in advance.2. Please use deionized water and clean glass or plastic containers during operation, and wear disposable gloves for operation.The entire silver dyeing process needs to be carried out on a shaker, with a rotation speed of about 60 rpm.4. Self prepared ethanol and glacial acetic acid are required.Instructions for useThe dosage of each solution in the following operation steps takes the gel with a size of 8.5 × 5.5 cm and a thickness of 1.0 mm as an example. The gel is immersed in the solution completely, and is operated on a shaker, with a general dosage of 25 ml. For large gel, the dosage of each solution should be scaled up according to the gel volume. Please prepare 50 ml of fixed solution (ultrapure water: ethanol: glacial acetic acid=6:3:1), 50 ml of eluent (10% ethanol), and 50 ml of termination solution (5% glacial acetic acid) in advance.1. Water washing: After electrophoresis is completed, wash the gel twice with ultrapure water for 5 minutes each time.2. Fixation: Fix the gel twice with 25 ml of fixative solution for 15 minutes each time.3. Elution: Wash the adhesive twice with eluent, each time for 5 minutes.4. Water washing: Wash the glue twice with ultrapure water, each time for 5 minutes.5. Sensitization: put the gel washed in the previous step into the silver dye sensitization working solution, incubate it accurately for 1 minute at room temperature, and then wash it with ultrapure water for three times, each time for 20 seconds. Preparation of silver staining sensitization working solution: Take 50 µ l Silver Stain Sensitivity (500 x) and add it to 25 ml of ultrapure water, mix well.6. Silver staining: discard ultrapure water and incubate gel in silver staining working solution for 30 minutes. Preparation of silver staining working solution: Take 25ml Silver Stain and add 50 µ l Silver Stain Enhanced to mix well.7. Water washing: Quickly wash the glue twice with ultrapure water, with each washing accurately controlled for 20 seconds.8. Development: Immerse the washed gel in the developer immediately and incubate it at room temperature for 2-3 minutes until the protein strip is clear. Preparation of developer: Take 25ml Silver Stain Developer and add 30 µ l Silver Stain Enhanced to mix well. Attention: Within 30 seconds of development, protein bands begin to appear and continue to develop for 2-3 minutes. If the protein band appears lighter, the development time can be appropriately extended to 5 minutes or more.9. Termination: After washing the developer on the gel with the termination solution, soak the gel in a new termination solution to react for 10 minutes.Experimental imagesSilver staining results of BSA protein samples after 10% SDS-PAGE gel electrophoresisThe molecular weight of BSA protein is about 66 kD, and the loading amounts from left to right are 50 ng, 10 ng, and 5 ng, respectively... Read More | DescriptionTakasago (R)-Ru Cymene Kit I comprises of ruthenium-based biphenyl phosphine cymene catalysts containing either BINAP and SEGPHOS®ligands. These highly reactive and selective catalysts are useful in a variety of asymmetric reactions, mainly asymmetric hydrogenation |