| Description | Products contentN665737Component24 T96 TStorageN665737ATPS V50 168 µL672 µL-20℃. Avoid freeze/thaw cycle.N665737B5×FA Reaction Buffer96 µL384 µL-20℃. Avoid freeze/thaw cycle.N665737CTS Buffer72 µL288 µL-20℃. Avoid freeze/thaw cycle.N665737D2×Products contentN665737Component24 T96 TStorageN665737ATPS V50 168 µL672 µL-20℃. Avoid freeze/thaw cycle.N665737B5×FA Reaction Buffer96 µL384 µL-20℃. Avoid freeze/thaw cycle.N665737CTS Buffer72 µL288 µL-20℃. Avoid freeze/thaw cycle.N665737D2×PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw cycle. * This kit is suitable for human genomic DNA library construction, the starting template DNA input is 5 ng. We also have transposase library construction kits for 50 ng and 1 ng of human genomic DNA starting, in order to get a higher quality library, it is recommended to use different kits for different starting amount of DNA. Products IntroductionThis kit is developed for Illumina's high-throughput sequencing platform and provides the enzyme premix system and reaction buffer for genomic DNA library construction, including all components except PCR primers. Compared with the traditional library construction kits, this kit adopts the new transposase method for library construction, which can complete DNA fragmentation, end repair and junction reaction in one simple enzymatic reaction, significantly reducing the amount of template, reducing the number of experimental steps, and shortening the time of library construction; it adopts the high-fidelity DNA polymerase for library enrichment, and the preference-free PCR amplification can expand the coverage area of the sequence, which can be used for efficient and effective sequencing. The use of high-fidelity DNA polymerase for library enrichment and preference-free PCR amplification broadens the coverage area of the sequence and enables efficient preparation of DNA libraries for Illumina's second-generation sequencing platform. The kit is suitable for use with a starting template DNA input of 5 ng, and all reagents in the kit have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. Product Features● DNA fragmentation and junction ligation in one step.● Ultra-fidelity amplification minimizes amplification preference.Provide your own instruments, kits and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use DNA purification and recovery kit by magnetic bead method.3. Library PCR primer kit: It is recommended to use transposase method for second generation sequencing multi-sample primer kit.4. Anhydrous ethanol, deionized water (pH between 7.0 and 8.0).5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes. Tips: It is recommended to use high quality filter tips to prevent contamination of kits and library samples. Pre-experiment Preparation and Important Notes1. Avoid repeated freezing and thawing of reagents.2. PCR products are easily contaminated due to improper operation, resulting in inaccurate results. It is recommended to isolate the PCR reaction system preparation area from the PCR product purification area, and to use special pipettes to clean the experimental areas at regular intervals.3. Bead purification: the beads should be equilibrated to room temperature before use, all operations on the beads should be carried out at room temperature, 80% ethanol should be dispensed freshly, the beads should be rinsed and dried until the surface is free of liquid reflections and has a frosted appearance, insufficient drying of the beads will cause ethanol residue that will affect the subsequent experiments, and over-drying of the beads will affect the efficiency of DNA recovery.4. The kit is suitable for human genomic DNA library construction, if the DNA sample is a PCR product, it should be ensured that its length>.500 bp, since transposases do not work on DNA ends, it is recommended to extend the PCR product by 50-100 bp at each end of the PCR product to avoid low coverage of the ends for sequencing. Sample PreparationDNA purity requirements: A260/A280 = 1.8-2.0. Sample DNA: dissolve in ultrapure water. DNA Quantification: Too much or too little DNA will affect the quality of the library. It is recommended to use Nano to test the purity of the genomic DNA and then use Qubit to test the concentration of the genome (do not use any absorbance-based assay for template quantification). Schematic diagram of DNA banking processprocedureDNA fragmentation, junction reaction 1. Add the following reagents to a 200 µl PCR tube: 2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows: inactivation reactionAfter the DNA is fragmented, the enzyme is still in a high active state, so it should be removed from the PCR instrument immediately and terminated by adding the Reaction Termination Buffer, in order to prevent the DNA from being fragmented too much and resulting in smaller library fragments.1. Add 3 µl of TS Buffer to the PCR tube containing the fragmentation product.2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Incubate at room temperature for 5 min, or if the room temperature is too low, place the reaction on a PCR instrument at 25°C with the thermal cover closed.1. Add the following reagents to a 200 µl PCR tube.2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows Selective recovery of library DNA fragmentsIt is recommended to use CombiVision Magnetic Beads DNA Purification and Recovery Kit for selective recovery of DNA fragments. When different sizes of DNA fragments are required, the amount of magnetic beads used is different, please refer to the attached table for the specific amount of magnetic beads used.(If using other brands of magnetic beads, you need to figure out the optimal amount of magnetic beads by yourself).Note: Amplification products can also be fragment length sorted and purified using the Gum Recovery Kit. If there is no special requirement for library length distribution, amplification products can also be purified directly from DNA fragments without selective recovery of DNA fragments as described on page 4 of the manual.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Transfer the PCR products to a 1.5 ml centrifuge tube, rehydrate to 100 µl, add several volumes of magnetic beads equilibrated to room temperature, vortex for 5 seconds, and let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, and carefully aspirate the supernatant and transfer it to a new 1.5 ml centrifuge tube.Note: Do not discard the top clear.4. Add several volumes of magnetic beads to the supernatant, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.5. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA.Note: Do not discard the beads.6. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.7. Repeat step 6 once.8. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 20 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.9. Remove the centrifuge tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new centrifuge tube. Table: Suggested amount of magnetic beads for different segment selection recovery Library DNA fragment purificationWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. 50 µl of magnetic beads equilibrated to room temperature were added to the PCR product, vortexed and shaken for 5 seconds, and then left to stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 25 µl of ddH O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube. Library quality controlDetermination of library concentrationIn order to obtain high-quality sequencing results, accurate quantification of DNA libraries is required, and the first recommendation is to use Real-timePCR methods are used for absolute quantification of DNA libraries. Additionally, fluorescent dye methods such as the Qubit method or the fluorescent dye picogreen method can be used; do not use quantification methods based on absorbance measurements here. The following approximate formula can be used to convert the molar concentration of the DNA library. Library fragment distributionThe prepared DNA libraries can be detected by agarose gel electrophoresis or Agilent 2100 Bioanalyzer.Range of segment length distributions... Read More | Product introduction:Dualucif The firefly & Renilla assay kit (dual luciferase reporter assay kit) provides an effective means to detect the expression of genes. In DLR detection, the activities of firefly luciferase and Renilla luciferase can be detected in a single sample in turn. FirstProduct introduction:Dualucif The firefly & Renilla assay kit (dual luciferase reporter assay kit) provides an effective means to detect the expression of genes. In DLR detection, the activities of firefly luciferase and Renilla luciferase can be detected in a single sample in turn. First, luciferin was used as substrate to detect the activity of firefly luciferase, then substances inhibiting the catalysis of firefly luciferase were added, and coelenterazine was added to detect the activity of Renilla luciferase to achieve dual luciferase reporter gene detection. The bioluminescence system of luciferase and its substrate can detect gene expression very sensitively and efficiently. Usually, the transcriptional regulatory element or 5'promoter region of the gene of interest is cloned upstream of luciferase, or the 3'-utr region is cloned downstream of luciferase to construct a reporter gene plasmid, and then transfect the cells. After the cells are treated with appropriate drugs, the cells are lysed, and the transcriptional regulation effect of drug treatment on the target gene is judged by detecting the luciferase activity. Renilla luciferase is more often used as an internal reference for detecting transfection efficiency to eliminate the difference in cell number and transfection efficiency. Firefly luciferase is a protein with a molecular weight of about 61 kDa. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. Renilla luciferase is a protein with a molecular weight of about 36 kDa. In the presence of oxygen, it can catalyze the oxidation of coelenteramide to coelenteramide, and also produce light signals in the process of coelenteramide oxidation. The optical signal of this kit can be measured by chemiluminescence instrument, microplate reader or liquid scintillation tester. The kit has the characteristics of rapid detection, high sensitivity, wide detection range and no interference of cell endogenous activity.Instruction:1.Cell lysis ( 1 ) Remove the medium and gently wash twice with PBS ( adherent cells can be operated directly, suspension cells need to be centrifuged to collect cells ). Add 1 × Lysis Buffer ( diluted component A with sterile water at 4 : 1 ) according to the following scheme, and then place the culture plate on a micro-oscillator at room temperature for 15 min to fully lyse the cells. Note : The pyrolysis products can be stored at room temperature for 6 h, and can be stored at − 70 °C for a long time ( the pyrolysis products cannot be repeatedly frozen and thawed ). ( 2 ) The pyrolysis products were centrifuged at 10000-15000 rpm for 3-5 min. After centrifugation, the supernatant was transferred into a new EP tube for subsequent detection. Note : Cells can be detected immediately after lysis, or frozen, and re-detected when needed. The frozen samples need to be thawed to room temperature for detection. 2. Preparation of working fluid ( 1 ) Restore all components to room temperature. ( 2 ) Dilute component C with component B to 0.2 mg / mL firefly luciferase working solution. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the amount of a single experiment is small, it is recommended to be subpackaged into small specifications according to a single amount of use. ( 3 ) The E component was diluted into the renilla luciferase working solution with the D component, and the dilution method was 1 µL E component was added to the 49 µL D component. Note : Renilla luciferase working solution needs to be prepared now. 3.chemiluminescence value detection ( 1 ) According to the operation instructions of the instrument, the instrument with chemiluminescence detection function was opened, such as multifunctional microplate reader. The parameters were set, the determination time was 10 s, and the determination interval was 2 s. ( 2 ) each sample determination, take the sample 20-100 µL ( if the sample volume is enough, please add 100 µL ; if the sample amount is insufficient, the amount can be appropriately reduced, but the amount of detection holes needs to be consistent ). 1 × Lysis Buffer was blank control. ( 3 ) 100 µL firefly luciferase working solution was added to determine the RLU ( relative light unit ) value ( it is recommended that the microplate reader set up the Shaking mixing function ). Note : Since the luminescence is instantaneous, it is recommended to detect immediately after adding the firefly luciferase working solution. ( 4 ) 100 µL renilla luciferase working solution was added to determine the RLU ( relative light unit ) value ( Shaking mixing function is recommended for microplate reader ). ( 5 ) In the case of renilla luciferase as an internal reference, the RLU value measured by firefly luciferase was divided by the RLU value measured by renilla luciferase. According to the obtained ratio, the activation degree of the target reporter gene between different samples was compared. If firefly luciferase is used as an internal reference, similar calculations can also be performed.Component:Recommendation:It is recommended to use component B in advance to prepare 2 mg / mL storage solution, component B, component D and component C prepared as storage solution, and to carry out small batch packing according to the experimental requirements. All test working fluids are recommended to be used now to avoid repeated freezing and thawing.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. in order to obtain the best determination effect, when using a single tube chemiluminescence instrument for determination, the time from the mixing of sample and determination reagent to the pre determination should be controlled as much as possible; When using a multi-functional fluorescent microplate reader with chemiluminescence detection function, it is advisable to add all samples first, and then uniformly add firefly luciferase detection reagent. 3. the strongest wavelength of firefly luciferase catalyzed bioluminescence is 560 nm, and the strongest wavelength of Renilla luciferase catalyzed bioluminescence is 480 nm. 4. to prevent interference between holes, it is recommended to use white opaque orifice plate. 5. due to the influence of temperature on enzyme reaction, the sample and reagent should be measured after reaching room temperature. 6. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Study on gene expression regulation and promoter... Read More | Inquire | Product introduction:This kit uses an improved SDS alkaline lysis method combined with DNA preparation membrane to selectively adsorb DNA to achieve the purpose of rapid purification of plasmid DNA. It is suitable for extracting up to 100u of high-purity plasmid DNA from 30-100 ml of Product introduction:This kit uses an improved SDS alkaline lysis method combined with DNA preparation membrane to selectively adsorb DNA to achieve the purpose of rapid purification of plasmid DNA. It is suitable for extracting up to 100u of high-purity plasmid DNA from 30-100 ml of bacterial culture for sequencing, in vitro transcription and translation, restriction enzyme digestion, bacterial transformation and other molecular biology experiments.Scope of application:Nucleic acid extraction and purification... Read More | The commonly used method of eukarYOtic gene expression regulation research is the detection of reporter genes, and bioluminescence is the most commonly used and effective means of reporter gene detection. Luciferase can catalyze the conversion of the substrate luciferin and emit photons. This The commonly used method of eukarYOtic gene expression regulation research is the detection of reporter genes, and bioluminescence is the most commonly used and effective means of reporter gene detection. Luciferase can catalyze the conversion of the substrate luciferin and emit photons. This product provides a rapid, sensitive and stable detection method for the expression of Renilla luciferase reporter gene in mammalian cells. Product characteristic:1.Rapid : Cell lysis was completed within 10-15 min ;2.Convenience : The reagent is easy to prepare, and the sample detection steps are simple;Instruction:1. Cell lysis ( 1 ) Remove the culture medium and gently wash with PBS ( adherent cells can be directly performed this operation, suspension cells should be centrifuged to collect cells ). Add 1 × Lysis Buffer ( diluted component A with sterile water at 4 : 1 ) according to the following scheme, and then place the culture plate on a micro-oscillator at room temperature for 15 min to fully lyse the cells. Note : The pyrolysis products can be stored at room temperature for 6 h, and can be stored at − 70 °C for a long time ( the pyrolysis products cannot be repeatedly frozen and thawed ). ( 2 ) The pyrolysis products after full pyrolysis were centrifuged at 10000-15000 rpm for 3-5 min. After centrifugation, the supernatant was moved into a new EP tube for subsequent detection. 2. Preparation of working fluid ( 1 ) Restore all components to room temperature. ( 2 ) Dilute component C into renilla luciferase working solution with component B, and the dilution method is to add 1 µL C component to 49 µL B component. 3.chemiluminescence value detection ( 1 ) According to the operation instructions of the instrument, the instrument with chemiluminescence detection function was opened, such as multifunctional microplate reader. The parameters were set, the determination time was 10 s, and the determination interval was 2 s. ( 2 ) The cell lysis products were added to the measuring tube according to the volume of 20 ~ 100 µL ( keep the same amount of samples each time ). 1 × Lysis Buffer was blank control. ( 3 ) 100 µL renilla luciferase working solution was added to determine the RLU ( Relative light unit ) value ( Shaking mixing function is recommended for microplate reader ). Note : The renilla luciferase working solution cannot be stored for a long time. It is now ready for use and is used once. Component:RenillaLuciferase Lysis Buffer;RenillaLuciferase Assay Buffer;CoelenterazineMatters needing attention:Scope of application: Matters needing attention:1.Please instantaneously centrifuge the product to the bottom of the tube before use, and then carry out subsequent experiments ; 2.Due to the influence of temperature on the enzyme reaction, the sample and reagent should be measured after reaching room temperature. 3.The strongest wavelength of bioluminescence catalyzed by renilla luciferase is 480 nm, in order to prevent interference between holes, it is recommended to use white opaque orifice plate ;4. B component is recommended to carry out small batch packing according to the experimental requirements ; 5.It is recommended to use it now to avoid repeated freezing and thawing ; 6.For your safety and health, please wear experimental clothes and wear disposable gloves. Scope of application:Study on gene expression regulation and promoter... Read More |